DIVISION 14 CONVEYING EQUIPMENT

Similar documents
Overhead Crane Specification prepared by SVEDA CRANES SPECIFICATION. * (Top/Under) running * (single/double) girder crane

.1 The following is a list of standards which may be referenced in this Section: .2 B30.11, Monorails and Underhung Cranes.

ELECTRONIC OVERHEAD TRAVELLING CRANE DIMENSIONS & LOAD DATA

CEILING MOUNTED WORK STATION STEEL BRIDGE CRANE

Provides the convenience of pre-fabricated bracing and bridge beam accessories.

Ontario ENGINEERING STANDARD SPECIFICATION 1.0 PURPOSE 2.0 OVERHEAD CRANES

WORK STATION BRIDGE CRANES & MONORAILS FREE STANDING & CEILING MOUNTED CAPACITIES FROM 250 TO 4000 LBS

CITY OF TAMPA ADDENDUM NO. 2. DATE: June 27, Contract 15-C-00021; Howard F. Curren AWTP HPO Gearbox/Mixer Upgrades and Piping Replacement

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT

Harrington Beam Accessory Kits. Options and Accessories: Consult Factory. Compliance

Options and Technical Data

BUSWAY Low Voltage (Pow-R-Flex)

FREE STANDING WORK STATION JIB CRANE

SPECIFICATIONS Top-Running Cranes With serial built Wire Rope Hoists

AREVA Federal Services LLC. Title: KW Annex Crane Procurement Specification. Document No: SPEC-M-001 Rev. No: D Page 2 of 12 REVISION HISTORY

P R O D U C T S PRODUCTS OUR PRODUCT LINE RANGES FROM:

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

Street A Division of Masco Steel Industries Ltd. Overhead Cranes. Jib Cranes. Gantry Cranes.

Product Line Glossary Terms

SPACEMASTER WIRE ROPE HOISTS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

SPACEMASTER WIRE ROPE HOISTS

& SK ELECTRIC WIRE ROPE HOISTS. COLUMBUS McKINNON CORPORATION

ACI Hoist & Crane. Festoon System. 689 S.W. 7th Terrace Dania, FL (954) Fax (954) Toll Free A-HOIST ( )

Design standards used : CMAA, CSA, AIST, AISE, OSHA, FEM, HMI, CWB, AWS, ANSI, ASME, ASTM, AGMA, NEC, NEMA, IEEE, UL, ISO

NRCT NATIONAL RIGGING & CRANE TRAINING LLC. Contact : CONSTRUCTION-INDUSTRIAL-SAFETY SERVICES

COLUMBUS McKINNON CORPORATION

GLOBAL KINGTM &WORLD SERIESTM

Owner s Manual. END TRUCKS Top Running & Underhung SERIES 3

ETA-5 RAIL SYSTEMS. , Unified Industries, Inc. All Rights Reserved.

INSTRUCTIONS AND PARTS LIST CRANE BRIDGE KITS CATALOG NUMBERS , & PUSH, HAND GEARED AND MOTOR DRIVEN

Guidelines for Safety Training of Overhead Crane Operators and Supervisors

PAGE 1 OF 5 HEALTH, SAFETY & ENVIRONMENTAL MANUAL PROCEDURE: S360 Overhead Cranes & Lifts Procedure REV 4.0 8/14/2012

Old Yale Hoist Manuals

City of Storm Lake Fire Department Heavy Rescue Specifications

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

Australian Standard. Cranes, hoists and winches. Part 18: Crane runways and monorails. AS (Incorporating Amendment Nos 1 and 2)

Toll-free:

PURPOSE... 1 II. SCOPE... 2 III. REFERENCES... 2 IV. RESPONSIBILITIES...

END TRUCKS Top Running & Underhung SERIES 3

Hoists Polipastos Hebezeuge Palans

Capital Projects Group Inverter, Rectifier and Charger Specification

Worker Crushed by Vessel Date of Incident: August 3, 2007 Type of Incident: Fatal

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

The new Yale Shaw-Box Crane Kit, the industry s most complete crane kit,

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

CRANE AND HOIST ST. PAUL, MINNESOTA HIBBING, MINNESOTA SUPERIOR, WISCONSIN WAUSAU, WISCONSIN

SHOP RIGGING & OVERHEAD HOIST SAFETY PROGRAM

INSTRUCTIONS AND PARTS LIST CRANE BRIDGE KITS 1/4 THRU 5 TON PUSH, HAND GEARED AND MOTOR DRIVEN TO BUILD UNDERHUNG CRANE BRIDGES

EASY CONNECT CRANE KIT Festoon Conductor Systems

Installation and Parts Manual for SPANCO PF Series Gantry Cranes

REVISIONS. App Thom. App Sud. App PC T.C. 2013/10/01

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

SUGGESTED SPECIFICATIONS

Interlocks 200 Series

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

BID SPECIFICATIONS FOR 16 STEEL DUMP BODY OPTION C (AUTOMATIC TRANSMISSION) WARREN WXL-16 $17, (INCLUDING OPTIONS)

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

SPECIFICATIONS OF SINGLE GIRDER UNDER SLUNG E.O.T. CRANE CAPACITY: 5 MT

Interlocks 325 Series

SECTION FIRE HYDRANTS WITH HYDRANT LOCKS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

*************************************************************************** SECTION D10 CONVEYING 02/18

BUILT WITH INTEGRITY

British Columbia - Colombie-Britannique. Aerial Lift - Appareil de Levage

University of Houston Master Construction Specifications Insert Project Name

SECTION METAL ATHLETIC SPORT LOCKERS

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

PIP ELEMT01 Guidelines for Selecting IEEE and API Standards for AC Motors 250 HP (185 kw) and Larger

INSTRUCTIONS AND PARTS LIST

World Series Monorail Hoists

Crane. Bridge. Crane Control. Crane. Force, breakaway. hook device. hook device. Friction-type pressure gripping lifters. Below. hook device.

ADDENDUM NO. 2 DATE: March 3, BID TITLE: Replacement of Two (2) Twenty Ton Overhead Crane Hoists, Trolley Packages, and Associated Equipment

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY AND HEALTH STANDARD. Filed with the secretary of state on

34-SDMS-02 SPECIFICATIONS FOR

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

General Instructions and Inspection Instructions for Crane

Cranes and Derricks. Objectives. Construction Safety Lecture 18

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Global King. Monorail Hoists

Owner s Manual. ELECTRIC WIRE ROPE HOIST and TROLLEY RH SERIES

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

Specifications for Enclosed Track Underhung Cranes and Monorail Systems

CITY OF DIXON, CALIFORNIA CITY ENGINEER / PUBLIC WORKS DEPARTMENT, WASTEWATER DIVISION SOLANO COUNTY, CALIFORNIA BID SPECIFICATIONS

ELECTRIC WIRE ROPE HOISTS

Under Running, Single Girder Overhead Cranes

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION

HPC500 Series Top Running and Underhung End Trucks

Certified to ISO 9001:2000 Standards. Standard Wire Rope Hoists

Inspection. Prepared for SAMPLE MAIN ST ANYTOWN NY

is integral to manufacturing produc vity. We will develop the right material handling system for your applica on.

2. Runway & Crane System

SOUND-RETARDANT- VERTICAL LIFT DOORS

12.- Rails. Crane, by Ternium, A 100 rail. 2 ( 239 and 240 ) Speed ( m / min. ) 15 ( at 50 Hertz )/1.5 ( at 5 Hertz )

Installation and Parts Manual for SPANCO A Series Steel Gantry Cranes

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Transcription:

DIVISION 14 CONVEYING EQUIPMENT

Page 1 of 4 Part 1 General 1.1 SCOPE OF WORK.1 Supply and install one (1) complete overhead (push trolley electric chain hoist) under running monorail crane systems as mentioned below. Any other requirements not set forth in these specifications, but necessary for the safe and reliable operation of the equipment, shall be included..1 CRN1: one (1) 2000Kg capacity over Dry Well in the proposed superstructure to lift the pumps including motors..2 Contractor shall furnish on this order:.1 All material necessary for complete installation of the above-mentioned cranes including runway beams, hangers and clamps..2 Complete controls..3 Equipment operating instructions.4 Drawings and parts lists as specified.5 The complete system, including the installation, must conform to the applicable requirements of the latest edition of the following:.1 Occupational Safety and Health Act (OSHA).2 American Gear Manufacturers Standards (AGMA).3 American National Standards Institute (ANSI).4 B30.10. Hooks.5 B30.16. Overhead Hoists (underhung).6 B30.17. Overhead and Gantry Cranes (top running bridge, single girder, underhung hoist).6 Contractor shall furnish the materials and labour for the following:.1 Complete erection..2 Steel runway beams..3 Steel runway beam support systems as per contract drawings..4 Electric power service as required. 1.2 RELATED SECTIONS.1 Section 05 50 00 Metal Fabrications 1.3 REFERENCES.1 The following is a list of standards which may be referenced in this Section:.1 American National Standards Institute (ANSI):.1 B30.10, Hooks..2 B30.11, Monorails and Underhung Cranes..3 HST 1M, Performance Standard for Electric Chain Hoists.4 HST 2M, Performance Standard for Hand Chain Manually Operated Chain Hoists..5 MH27.1, Underhung Cranes and Monorail Systems..2 Canadian Standards Association:.1 CSA C22.1, Canadian Electrical Code, Part I (20th Edition). 146300.doc Stantec

Page 2 of 4.2 CSA C22.2 No. 33-M1984 (R2004), Construction and Test of Electric Cranes and Hoists..3 National Electrical Manufacturer s Association (NEMA):.1 MG 1, Motors and Generators..2 250, Enclosures for Electrical Equipment (1,000 volts maximum)..4 Electrical Equipment Manufacturers Advisory Council (EEMAC):.1 M1-7, Motors and Generators..5 National Fire Protection Association (NFPA): 2005 National Electrical Code (NEC) (NFPA 70):.1 Article 610, Cranes and Hoists. 1.4 DESIGN REQUIREMENTS.1 Monorail System: Specifications for Underhung Cranes and Monorail Systems, ANSI MH27.1 and ANSI B30.11..2 Hoist: ANSI B30.11, Hoist Manufacturers Institute..3 Trolley: ANSI MH27.1..4 Chain Hoist Service Class: ANSI HST 1M..5 Hook: ANSI 30.10. Stress and Safety Factors: ANSI MH27.1 and ANSI B30.11. Properly select materials of construction for stresses to which subjected..6 Safety of Operation, Accessibility, Interchangeability, and Durability of Parts: ANSI B30.11 and OSHA requirements. 1.5 SUBMITTALS.1 Submit certified Shop Drawings in accordance with Section 01 33 00 Submittal Procedures..2 Submit the following:.1 Manufacturer s name and catalogue number of any equipment to be furnished not manufactured by vendor..2 Any exception or difference of any equipment to be furnished from that specified and reason for the substitution..3 Name and address of manufacturer s representative nearest the St. Boniface Industrial Park Phase 2 Pumping Station site maintaining 24-hour service facilities and complete stock of spare parts..4 Supply spare parts as required for one year's maintenance..5 Installation, operation, maintenance and lubrication manuals..6 Shop drawing for the crane beam support systems sealed and signed by a professional Engineer registered in the Province of Manitoba. Part 2 Products 2.1 DESIGN CONDITIONS.1 The equipment will be operated in ambient temperatures ranging from 5 C to 40 C. 146300.doc Stantec

Page 3 of 4.2 All bearings in trolley and hoist shall be lifetime lubricated..3 Each hoist and chain shall be load tested to 125% capacity and test certificates shall be submitted to Contract Administrator..4 Size of crane beams and connection to roof framing shall be as per the contract drawings..5 Other design conditions: Parameter Crane # Crane Type Value CRN#1 Capacity rating (kg) 2000 Type of Trolley Monorail length(m) Beam Size Beam Flange Total lift (m) 15 Hoist Design Standard Chain Acceptable Manufacturers 2.2 ELECTRICAL REQUIREMENTS Underhung monorail cranes Push Trolley As shown on structural drawings S381x64 140 mm Motorized Columbus McKinnon Co. AM Army type Stainless Steel Columbus McKinnon Co., Kito, Harrington or approved equal in accordance with B7..1 All power supply shall be 120 V single phase or 208 V, 3 Phase, 60 Hz alternating current..2 Supply and install all necessary wiring to connect all parts to the equipment to the junction boxes installed by the electrical trade. All wiring shall be installed in accordance with the Canadian Electrical Code..3 All controls from hoists, trolleys etc., where electrified shall be of the pendent pushbutton type and shall operate on 110V, single phase, 60 Hz power alternating current. 146300.doc Stantec

Page 4 of 4 Part 3 Execution 3.1 EQUIPMENT DESIGN SAFETY.1 All equipment furnished to vendor s standard design, which incorporates weld elements, is to be welded in accordance with the appropriate codes and standards of the Canadian Welding Bureau and Canadian Standards Association..2 All equipment non-standard design to fulfill special requirements shall, in addition, meet the following:.1 All critical welds, the failure of which would cause potential accidents or injuries to personnel, are to be executed with special attention as outlined in this section..2 An audit is to be made by the vendor to determine those welds to be in the critical category. Such welds are to be given special attention by the vendor to insure adequate quality control. 3.2 INSTALLATION.1 Before leaving the factory the crane and hoist shall be tested under all motions..2 Install the equipment described above in accordance with the drawings and with strict adherence to the manufacturer s instructions..3 Ensure that the crane rails are perfectly horizontal, correctly aligned, and properly fastened to the supporting structures. Install the travel limits stops on each end of rails..4 Lubricate all necessary points on the as per manufacturer s recommended lubricates. 3.3 PAINTING AND FINISHING.1 The crane assembly shall receive one shop coat of high visibility yellow epoxy paint..2 All exposed surfaces of crane to be painted after installation..3 The capacity of crane systems shall be clearly painted on the side of the crane beam. 3.4 INSPECTION AND TESTS.1 Do performances test on each hoist and monorail systems..2 Load tests in compliances with OSHA, ANSI B30.11, and ANSI MH27.1..3 Final acceptance will be made after the entire installation and testing has been completed. All tests required to prove the ability of the crane shall be made by the Contractor. A vendor s representative is invited to attend. 3.5 GUARANTEE.1 Vendor shall guarantee all materials and workmanship of equipment installed under these specifications for a period of one (1) years after installation. END OF SECTION 146300.doc Stantec