LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

Similar documents
AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

Item Code Description Unit Qty Total

Key features. DESIGNS: - Conservator type - Hermetically sealed

Max value Max life Range from. ($000) (Years) Pole Type

URD Mini Pillar Installation Guide. UDS Universal Pillar Installation Guide. Cable to LV Isolators, Crossarm and Cable Detail

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

ANNEXURE-I : LIST OF ITEMS H.O. PURCHASE ITEM LIST:

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

LV MV HV SPECIALISTS. Cable Installation, Jointing, Substation & Electrical Equipment TOTAL SUPPLY ELECTRICAL POWER PRODUCTS

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

Outdoor Power Transmission & Distribution

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Schedules 1 to 4, Lot B: Extension of the Lessos Substation

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip

PRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE)

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

NS Feeder pillar up to 3200A

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Transmission & Distribution Glossary of Electrical Terms

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Pretest Module 29 High Voltage Unit 1

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Benefits, typical uses

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

PRE-AMBLE TO THE STANDARD SPECIFICATION FOR MEDIUM AND LOW VOLTAGE ELECTRICITY DISTRIBUTION WORKS

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test)

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

NXPLUS C Single busbar. Maintenance-free for lifetime

GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

ELECTRICAL MATERIAL SUPPLY

SOUTH AFRICAN NATIONAL STANDARD

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Metal Clad Switchgears

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Substation Committee K2 TF1 of the GIS Subcommittee GIS/GIL/SF 6 -Tutorials

NATIONAL POWER INDUSTRIES

with Vacuum Circuit Breaker HAF

2013 JEAN MÜLLER Products

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet

Estimate of Under Ground Electrification Work

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Set /

Distribution transformers Efficiency over life-cycle

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AMENDMENT ELECTRIC SERVICE MANUAL 2014

COMPACT SUBSTATION GUIDE

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Extensible Unit - VCE2a

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

N2XSERY 3 x (25-300) mm² 3.6/6 kv

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

List of materials for 1Km. Of L.T line 1-Ph., 2-Wire AB cable (1 X 25+1X16) sq.mm using 8M X 200 KG. PSC Pole

SWITCHBOARDS (LV and MV)

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

31-SDMS-01 REV. 03 SPECIFICATIONS FOR

EDS SUBSTATION LVAC SUPPLIES

ECS CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

Modular integrated transportable substation (MITS)

TENDER DOCUMENT. (TENDER No: NRO/CON/696/660) FOR

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

32-SDMS-01 REV. 02 SPECIFICATIONS FOR

Gas Insulated Switchgear

Underground Distribution Construction Manual

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH

MEDIUM VOLTAGE SWITCHGEAR

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

Collection of standards in electronic format (PDF) 1. Copyright

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

Cable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples.

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Technical Specification of GECOL. Packaged Transformers

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

STROM SICHER SCHALTEN

Wisconsin Public Utility Institute. June 28, Minimum Distribution Charges. Larry Vogt. Director, Rates Mississippi Power

Gas Insulated Metal-clad Switchgear, HMGS!

Product Specification

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

NEXT STEP B) SAFETY :

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

SWITCHGEAR DIVISION PRODUCT PROFILES

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

Transcription:

No Description/ Specification Amendment 1 EDD 1 :2008 11/0.415 kv Distribution Transformer, Oil Filled - 2 ED 2 :1987 The Galvanization of Iron and Steel, Articles Other Than Steel Wire - 3 ED 3 :1979 11 kv/ LV Unite Substation - 4 ED 4 :1978 Lightning Arresters For Application On The 11 kv System - 5 ED 5 :1982 Power Cable for Electric Supply 11 kv and 1 kv Specification - 6 ED 6 :1985 11 kv Ring Main Switchgear for the Distribution System 1 & 2 7 ED 7 :1989 6.35 / 11kV XLPE Insulated Cables 1 8 EDD 8:2011 Version 1.9 0.6/1kV XLPE Insulated Cables - 9 ED 10 :1982 Low Voltage Cast Resin Joints for Distribution Cables - 10 ED 11 :1982 Mechanical Cable Gland for Low Voltage armoured XLPE Insulated Power Cable - 11 ED 12 :1982 LV all Insulated Weatherproof Wall Mounted Fused Cut-out - 12 ED 13 :1984 Glass Reinforced Plastic Housing for Unit Sub-station - 13 ED 14 :1984 11 kv Pole-mounted Air Breaker Switch-disconnector - 14 ED 15 :1991 11 kv & LV Bare Copper Conductor for Overhead Line - 15 ED 18 :1987 Alternating Current Watt-Hour Meter 1, 2, & 3 16 ED 20 :1989 6.35/ 11 kv Heat-Shrink Termination And Accessories 2, 3 & 4 17 ED 21 :1989 6.35/ 11 kv Heat-shrink Joints and End Seals 2 & 4 18 ED 22 :1988 0.6 /1 kv Heat-shrink Termination and Accessories - 19 ED 23 :1989 0.6 /1 kv Heat-shrink Joints and End Seals - 20 ED 26 :1991 Pole-mounted Distribution Transformer (Mineral Oil) 1 21 ED 31 :1989 11 kv and LV PVC Covered Overhead Conductor 1 22 ED 1002-1184 (S-4036 A) C.I.LV Underground Straight Through Joint Box 240 SQ.MM. 4 Core 1 23 ED 2001-1284 Enclosed Distribution Panel for Streetlighting 1, 2, & 3 24 25 ED 2002-85 (S-4139 A) ED/SL/C/10 (S-4039 A) Pre-wired Control Gear on Trays - Street Lighting Column and Brackets - 26 EDD 1001-1184 :2006 PVC Insulated and Sheathed Flat Twin 2 35 SQ.MM Copper Cable - 27 EDD 721-0-0 :1997 Classification of Service Condition for Supply of Equipment / Materials 2 PAGE 1 OF 6

1 S-3013 D Cutout for Street Lighting - 2 S-3014 E Distribution Transformers - 3 S-3015 C Metal Enclosed 1 kv ACB/ MCCB 3 4 S-3016 D PECU (Photoelectric for Control Unit) Assembly for Street Lighting - 5 S-4003 C Line Tap - 6 S-4004 A Electricians Rubber Gloves - 7 S-4008 A Heat Shrinkable Tubing - 8 S-4017 B Weak-back Ferrule - 9 S-4019 C House Service Dumb-Bell Assembly - 10 S-4021 F Caution/ Warning tape 1 11 S-4022 E 6.35/ 11 kv Pole Mounting Heat-shrink Termination - 12 S-4023 C 0.6/1 kv Pole Mounting Heat shrink Termination - 13 S-4024 A Breakout, Heat Shrink, LV - 14 S-4025 H Lightning Arresters for Application on the 11 kv Overhead Line System 1 15 S-4026 A Power Cable - 16 S-4027 A 11 kv Ring Main Units (Oil) - 17 S-4031 H Low Voltage Cast Resin Joints for Distribution Cables - 18 S-4032 D Metallic Mechanical Cable Glands for 0.6/1 kv Armoured XLPE Insulated Cable 1 19 S-4033 A LV Cut-outs (All Insulated Weather Proof Wall Mounted) - 20 S-4034 E Glass Reinforced Plastic Housing for Kiosk Substation - 21 S-4035 K 11 kv Sulphur Hexafluoride (SF6) Ring Main Switchgear 5 22 S-4036 C Cast Iron LV Straight Through Joint Box - 23 S-4037 B Cast Iron 11 kv Straight Through Joint Box - 24 S-4038 A Foundation Bolt (Street Lighting) - 25 S-4039 ED/SL/C/10 Octagonal Tapered Street Lighting Columns - 26 S-4040 A Wire, Copper Conductor - 27 S-4044 B Innards for Cut-out - PAGE 2 OF 6

28 S-4045 A 11 KV Air Break Switch Disconnector - 29 S-4046 B Street Lighting Luminaires for use in Residential Areas of High Vandalism - 30 S-4047 A Street Lighting Luminaires for Major Traffic Routes - 31 S-4048 A Street Lighting Luminaires (for use in Minor Traffic Routes) - 32 S-4049 A Street Lighting Luminaires (for Use in Group B Residential Areas) 1 & 2 33 S-4050 A Street Lighting Luminaires for use in Group B Residential Areas - Post Top Opal Spherical Type - 34 S-4051 G Cut-out, Insulated Domestic Service 1 & 2 35 S-4052 D 11/ 0.4 kv Distribution Transformer Silicone Liquid Filled 2 36 S-4053 A Fire Resistance (Cast Resin Type) Distribution Transformer 1 & 3 37 S-4054 C Overhead Lines Insulated (H.V.) - 38 S-4055 F 11 kv Kiosk Substation (Mineral Oil) 6 39 S-4056 D Socket Cable - 40 S-4057 E Heat Shrink, Termination 11 kv Indoor - 41 S-4063 A 11 KV Fault Passage Indicator 1 42 S-4069 C 11 KV Pin Insulator - 43 S-4073 C Wire, Overhead Service Lines - 44 S-4075 A Incandescent Lamps - 45 S-4076 A Stirrup Binding-In - 46 S-4081 A Fluorescent Lamp - 47 S-4082 B Insulator Coach Screw - 48 S-4083 E LV (1 kv) Distribution Fuse Board & Cabinet 1 49 S-4084 F Distribution Fuse - 50 S-4085 A Bracket With Control Gear - 51 S-4086 B Stay Rod - 52 S-4089 D PVC Pipe (Duct), Unplasticised - 53 S-4095 B 6.35/11kV Beam Insulator - 54 S-4097 F Copper Clad Earth Rod and Accessories - 55 S-4101 B 0.6/1 KV, PVC/ PVC Cable - PAGE 3 OF 6

56 S-4102 D Ring Type Current Transformer for Metering 1 57 S-4103 D Current Limiting Fuse-Link (Domestic) 1 58 S-4104 D Fuse Carrier - 59 S-4122 E Cut-out Cast Iron Indoor/outdoor - 60 S-4123 A Heat Shrink Wrap Around Repair Kit - 62 S-4124 D 11 kv Oil Switch - 63 S-4125 B 0.6/1kV PVC/PVC Insulated Single Core cable - 64 S-4126 B 11kV Oil Fuse Switch - 65 S-4127 A Heat Shrink Joint kit - 66 S-4128 B 6.35/11kV Heat Shrink Joints - 67 S-4129 C 6.35/11kV XLPE Insulated Cables - 68 S-4130 C Pot End, Heat Shrink Kit - 69 S-4131C Silica Gel, Cobalt Chloride Impregnated - 70 S-4132 C Low Voltage Pole Mounted Fuses - 71 S-4133 B Coupling, Bus-bar, Assembly - 72 S-4134 B End Cap, Busbar, Assembly - 73 S-4135 E 11 kv (SF6)/ Vacuum Circuit Breaker Uint 2, 3 & 4 74 S-4136 C Channel, Cable Protection P.M. Type - 75 S-4139 A ED 2002 :85 Pre-wired Controlgear on Trays - 76 S-4140 B 0.6/1 kv XLPE Insulated Cables - 77 S-4141 C Fuse-Link HRC 12 kv Oil Tight Type II - 78 S-4142 E Indoor / Outdoor Cut-out for XLPE Cable 2 & 3 79 S-4143 A 11 kv Current Limiting Fuse Link for SF6 RMU 80 S-4144 C Gland Kit for Indoor / Outdoor Terminations Of 11 kv XLPE Insulated Cable 1 81 S-4145 B Covers for Underground Distribution Cable - 82 S-4146 E Compression Connectors and Compression Cable Sockets 5 83 S-4147 A Electrical Insulation Tape - PAGE 4 OF 6

84 S-4148 A 400V, Three Phase MCCB for Service Connections - 85 S-4149 C Ladder, Linesman s Wooden - 86 S-4135 E 11 kv (SF6) / Vacuum Circuit Breaker Unit 2, 3 & 4 87 S-4150 C 6.35/11 kv XLPE/EPR Insulated Submarine Cable and Accessories - 88 S-4201 A Earthing Equipment Temporary 11 kv - 89 S-4203 A Disc Insulator 11 kv for O/H Lines - 90 S-4205 A Pole Mounting Bracket for Lighting Arrester - 91 S-4206 B Gasket Material for Transformer and Switchgear - 92 S-4207 A Wood Battens - 93 S-4210 B 6.35/11 kv XLPE INSULATED SINGLE CORE CABLES 1 & 2 94 S-4211 C 6.35/1 1kV Heat-Shrink Terminations And Accessories For Single Core Cables 1 95 S-4212 A Silicone Liquid FOR Distribution Transformers - 96 S-4213 A Mechanical Connector and Cable Socket - 97 S-4214 A 6.35/11 kv Heat-Shrink Joints & End Seals For Single Core Cables - 98 S-4216 D Temperature Control Equipment for FB Sub-station - 99 S-4217 A 0.6 / 1 kv XLPE Insulated Single Core Cables - 100 S-4218 A ACB, 0.44 kv, Withdrawable - 101 S-4219 A ED 26 Pole Mounted Transformer 1 102 S-4220 A 11 kv Fault Current Indicator (For Overhead Lines) - 103 S-4221 A 11000/415V Distribution Transformer, Dry Type - 104 S-4222 C Cable and Fault Search Set for 11 kv and LV Cable Network - 105 S-4223 A Digital A.C. Clamp Meter and Clamp Adaptor - 106 S-4226 B Concrete Cover for Underground Distribution Cable - 107 S-4227 A 0.4 kv Portable Temporary Earthing Equipment - 108 S-4228 E Fire Rated Steel Door For Free Building / Precast Building Substation 1, 2 & 3 109 S-4230 A Dry Type, 11 kv Metering Unit - 110 S-4231 A Oil Type HV Metering Unit - 111 S-4232 B Grip, Guy, Dead End - PAGE 5 OF 6

112 S-4233 B Feeder Pillar Steel Enclosure 1 113 S-4235 C Louvered Steel Vent for Distribution Substation - 114 S-4236 C Precast Concrete Housing for Kiosk Substation - 115 S-4237 A Electronic Meter - 116 S-4239 A Cold-Shrink, 11 kv Cable Joint and Termination Kits (Indoor/Outdoor) 1 117 S-4243 C Electronic Electricity Meters for Tariff and Billing Purposes 1 118 S-4244 A Street Lighting High Mast - 119 S-4245 A Earth Leakage Circuit Breaker - 120 S-4246 A Demotic Meter Cabinet - 121 S-4248 B Moulded Case Circuit Breaker in Enclosure for Service Connections - 122 S-5002 A GRP Housing for Streetlighting Feeder Pillar - 123 S-6000 A Mini Distribution Pillar - 124 S-6002 A 11kV Kiosk Substation (Mineral Oil 1500 kva) 2 & 3 125 S-6003 A LV (1 kv) Distribution Fuse Board & Cabinet with Safety Shield. - PAGE 6 OF 6