SKD62UA Series Electronic Valve Actuator, Advanced Features

Similar documents
SKD U Electronic Valve Actuator

SKD U Electronic Valve Actuator

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

SAX Electronic Valve Actuator

SAX Electronic Valve Actuator

Flowrite EA 599 Series SQX Electronic Valve Actuator 24 Vac, 3-Position Control

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Proportional Control

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac 3-Position (Floating) Control

599 Series Zone Valves

Flowrite EA 599 Series SKB/C Electronic Valve Actuator 24 Vac, 3-Position (Floating) Control

Technical Data 1 /2 3 / /4 1 1 /2 2. Cv TABLE

Flowrite 599 Series SKB/C Electronic Valve Actuator 24 Vac, 3-Position (Floating) Control

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

Packing Replacement Kit for Flowrite VF 599 Series Valves

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Floating Control

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

Rebuild/Repack Kits for Flowrite VF 599 Series 2-1/2 to 6-inch Valves

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position)

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Flowrite TM AP 599 Series 8-inch Pneumatic Valve Actuator

Flowrite AP 599 Series

Pressure Independent Control Series

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

SAV Electronic Valve Actuator

Pressure Independent Control Series

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

Powers Controls 656 Powermite Valve with 3-inch Top Rebuilding

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

Powers TM Controls EA 338 Electronic Actuator

TEC Actuator Package. Product and Part Numbers. Product Description. Installation Instructions Document No October 27, 2010 CAUTION:

Master/Slave Actuators Spring Return Rotary 24 Vac - Modulating Control

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Powers TM Controls SW 134 Pressure Electric Switch (Adjustable Differential)

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

SED2-BT300-XX-C09 Migration Kits. Product Numbers

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

MVF461H Series Modulating Control Valves with Magnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

VE VVG Series Electronic Two-way Valves Normally Closed

MF Series MS Series

Laboratory Exhaust Air Terminal

Flowrite 599 Series High Pressure Close-Off 2-Way Valves, 2-1/2 to 6-Inch, Flanged Iron Body, ANSI Classes 125 & 250

OpenAir GCA Series Spring Return 142 lb-in Electronic Damper Actuators

Technical Instructions Document No P25 EA GMA January 19, OpenAir. GMA Series Spring Return Rotary Electronic Damper Actuators

Technical Instructions Document No P25 EA GMA May 19, OpenAir. GMA Series, Spring Return, 62 lb-in, Rotary, Electronic Damper Actuators

Powers Controls RL 147 Positioning Relay

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

SED2 Variable Frequency Drives

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Electro-hydraulic actuators for valves

SmartX MF and MS

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Flowrite 599 Series. Technical Bulletin. 1/2 to 2-Inch Valve (2-Way & 3-Way) and Actuator Assembly Selection. Document No.

Electrohydraulic actuators for valves

599 Series Ball Valve and Actuator Assemblies Selection

Ball Valve Bracket Kit

599 Series Ball Valve and Actuator Assemblies Selection

VVP45 and VXP45 Series Two-port and Three-port Seat Valves ANSI Class 250 Short-stroke Valves

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Flowrite VF 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

Accessories/Kits Ball Valve Bracket Kit (includes bracket, mounting screws, shaft and handle)

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

599 Series 6-Way Ball Valves

Pressure Independent Control Series 2-Way Valves and Electronic Valve Actuators

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

599 Series 2-Way Ball Valves

Powermite 599 MT Series Terminal Unit Valve and Actuator Assembly Selection

Powers Controls Powertop Two-Way Valves Normally Open

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

Electro-hydraulic actuators for valves

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

MXF461 U Series Modulating Control Valves with Magnetic Actuators

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) EN44 and EN88 Non-Spring Return Electronic Actuators

OpenAir. Technical Instructions. GCA Series Spring Return 160 lb-in Electronic Damper Actuators. Document No P25 EA GCA-1.

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

Powermite 599 Series MT Series Terminal Unit Three-way Valves

Flowrite 599 Series Two-Way Valves 1/2 to 2-inch Bronze Body

Powermite 599 MT Series Terminal Unit Valve and Actuator Assembly Selection

Powers TM Controls SW 141 Differential Static Airflow Switches

RDG160TU Commercial Thermostat

Electrohydraulic actuators for valves

Electro-hydraulic actuators for valves

POWERS TM CONTROLS LC Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator

Ball Valve Bracket Kit

Flowrite Globe. Pneumatic 4-inch Valve Actuator. Valves. Description. Applications. Features D-141.

Powers TM Controls RL 243 SW Switching Relay

Transcription:

Document No. 29-69 October 6, 22 SKD62UA Series Electronic Valve Actuator, Advanced Features Product Description The SKD62UA electronic valve actuator requires a 24 Vac supply and receives a to Vdc or 4 to 2 ma control signal to proportionally control a valve. These actuators are designed to work with the Flowrite VF599 series valves, or other manufacturer's valves with fitted with the appropriate Universal Valve Retrofit Kit. Product Numbers SKD62UA Warning/Caution Notations WARNING: Required Tools 5 mm hex wrench Personal injury or loss of life may occur if you do not follow a procedure as specified. Equipment damage, or loss of data may occur if you do not follow a procedure as specified. Small and medium flat-blade screwdrivers Expected Installation Time 2 minutes for factory installed actuator 45 minutes for field replacement of actuator Prerequisites WARNING: If mounting the actuator to a valve already in line, either close the shut-off valves in the piping (upstream first, then downstream) or switch off the pump to allow the differential and static pressure in the valve to drop. Mounting Positions EA92R Not allowed with the Weather Shield Not allowed in any circumstance Figure. Acceptable Mounting Positions. Using the Weather Shield The SKD62UA must be in the vertical position. Complete instructions for the mounting of the weather shield are included with that product. NOTE: Use the top knockout position when installing the Weather Shield. See Figure. EA857R VENTILATION OPENINGS VENTILATION OPENINGS Figure 2. Weather Shield Installation Position. Item Code: 29-69, Rev. Page of 6

Document Number: 29-69 September, 22 «Installation If you are mounting an actuator on a new valve, begin with the instructions in Figure. 4 Removing the Actuator from the Valve. Remove the actuator cover. 2. Disconnect the wires and conduit, if installed. EA82R Figure 5.. Loosen the valve stem retainer using a 5 mm hex wrench and lower the valve stem into the valve. 4. Loosen the yoke nuts in the actuator yoke using a 5 mm hex wrench. 5. Remove the actuator from the valve, use care not to damage the valve stem. Continue with Mounting an Actuator to a Valve. EA84R 5 mm 5 Figure 6. NOTE: Hold the stem retainer in place as you tighten it around the valve stem. See Figure 6. EA4R Figure. Preparing a new Valve. Mounting an Actuator to a Valve. NOTE: Install the packing heating element, (P/N 599-47), if used, before proceeding. EA8R2 5 mm MAX. TORQUE 4 lb-in (4.5 Nm) 6 Figure 7. x6 «MAN «NOTE: Position the actuator to accommodate the wiring. Hold the actuator in place while tightening the yoke nuts. See Figure 7. EA8R 2 7 5 x 6 >x6 «AUTO 5 mm Figure 4. NOTE: Make sure the yoke nuts are loose enough to allow the actuator to slip over the bonnet. See Figure 5. Page 2 of 6 EA8R Figure 8. Siemens Building Technologies, Inc.

Document Number: 29-69 September, 22 Wiring Use care when removing the knockout. Do not damage the circuit board. Do not use autotransformers. Use earth ground isolating step-down Class 2 transformers. Wiring Diagrams Determine supply transformer rating by summing total VA of all actuators used. The maximum rating for a Class 2 power supply circuit is VA. Actuator Power Consumption Actuators per Class 2 supply circuit* (8% of transformer VA) SKD62UA 7 VA 4 * Operating more actuators requires additional transformers or separate VA power supplies. Connection Terminals Calib. Stroke Calibration G G Y M U Z AC 24V G 5/6Hz... V G 4... 2mA Chm Status Green OK Calib. Rotary Switches LO and UP Calib. Status Red Error Valve Jam LED Status Indication EA77R 2 4 Figure 9. DIP Switches. 2 4 DIP Switches Sequence Control Selection of Selection of Select Direction (From Left to Right) or Control Flow of Operation Stroke Limit Control Signal Characteristic ON Reverse-acting Sequence control 4 to 2 ma Modified* OFF Direct-acting Stroke limit control to Vdc Default (Factory Settings) *Changing the default setting will modify an equal percentage valve to a linear flow characteristic. When set to default, the flow characteristic is determined by the valve body. Siemens Building Technologies, Inc. Page of 6

AC 24 V Document Number: 29-69 September, 22 EA74R G B M G B Y G Y M U Z G M M B N Y Figure. Connecting Terminals 2 F G (SP) G (SN) 24 Vac G System Potential (SP) G System Neutral (SN) Y Control Input: to Vdc or 4 to 2 ma Z (DIP switch selectable) Override Control (See Technical Instructions 55-77) M Measuring Neutral U Output for to Vdc or 4 to 2 ma measuring voltage. It will match the input signal type. The position output signal U will switch from to Vdc to 4 to 2 ma when a 4 to 2 ma input signal is selected and used on the terminal. Start Up Check the wiring for proper connections. B Sensor F Temperature Limiter N Controller Y Actuator Consult the Technical Instructions 55-77 for detailed commissioning instructions. Stroke Calibration To determine the stroke positions and % in the valve, calibration is required when the valve/actuator are commissioned for the first time. The actuator must be mechanically connected to a valve and must have a supply voltage of 24 Vac. The calibration procedure can be repeated as often as necessary. To initiate the calibration procedure, short circuit the contacts inside the slot located on the printed circuit board (with a screwdriver). EA65R Automatic calibration proceeds as follows: Actuator runs to the stroke position () the green LED flashes. Actuator then runs to the % stroke position (2) the green LED flashes. Measured values are stored in the EPROM. EA66R % % Stroke The actuator now moves to the position defined by control signal Y or Z (), and the green LED now glows steady (normal operation) Throughout this procedure, output U is inactive, meaning the values only represent actual positions when the green LED stops flashing and remains on continually. Table. LED Status. LED Display Function Action ON Normal Operation Automatic operation Green Red Flashing ON Stroke calibration In Progress Faulty stroke calibration 2 Wait for calibration to be completed (LED stops flashing) - Check mounting - Restart stroke calibration (by shortcircuiting calibration slot) Internal Error - Replace electronics Flashing Inner valve jammed Check the valve No power OFF supply -Check mains Faulty -Replace electronics electronics Before starting calibration, be sure that the manual adjuster is set to Automatic to register the actuator values. y Page 4 of 6 Siemens Building Technologies, Inc.

Document Number: 29-69 September, 22 Normally Closed Valve Actuator pressure cylinder moves: Outward ( to ): Valve opens. Inward ( to ): Valve closes. Normally Open Valve Actuator pressure cylinder moves: Outward ( to ): Valve closes. Inward ( to ): Valve opens. Three-Way Valve Actuator pressure cylinder moves: Outward: Valve opens between port NC and C. Inward: Valve opens between ports NO and C. NOTE: The valve body assembly determines the complete assembly action. Manual Operation EA87R /4 in. (2mm) Figure 2. Valve Stem Travel Indication. Dimensions -/4 (285) >x6 << AUTO >> 8-/6 (224) EA8R << MAN >> << AUTO >> Figure. Manual Override in Manual and Automatic Position. Each complete revolution (6 ) is equal to /2-inch (2.5 mm) stroke. Reference Technical Instruction EA599-8 Flowrite 599 Series SKB/C/D 62UA Series Electronic Valve Actuator, 24 Vac Proportional Control Advanced Features Document Number 55-77 2-7/8 (27) EA854R 9-/8 (22) 4-/2 (4) 4-/6 (22) 4-/6 (22) 2-9/6 (65) 5 (26) /4 (9) -5/6 (49) Figure. 599-7 Weather Shield Dimensions in Inches (Millimeters). Siemens Building Technologies, Inc. Page 5 of 6

Document Number: 29-69 September, 22 Dimensions, Continued Use care when removing the knockout. Do not damage the circuit board. NOTE: Use the top knockout position when installing the Weather Shield. SERVICE ENVELOPE 2-/2 (64) 4-/8 (5) KNOCKOUT FOR STANDARD /2" CONDUIT CONNECTOR 4-/4 (2) Ø5 (27) MINIMUM ACCESS SPACE RECOMMENDED 4 inch ( mm) 5-5/8 (4) -/6 () 4-7/8 (2) 8 inch (2 mm) EA85R 2-5/8 (66) Ø-/4 (44) Ø2-9/6 (65) Figure 4. SKD62UA Dimensions in Inches (Millimeters). Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Flowrite is a trademark of Siemens Building Technologies, Inc. Other product or company names mentioned herein may be the trademarks of their respective owners. 22 Siemens Building Technologies, Inc. Siemens Building Technologies, Inc. Deerfield Parkway Buffalo Grove, IL 689-45 U.S.A. Your feedback is important to us. If you have comments about this document, please send Document No. 29-69. Printed in the U.S.A. them to technical.editor@sbt.siemens.com Page 6 of 6