SKD U Electronic Valve Actuator

Similar documents
SKD U Electronic Valve Actuator

SKD62UA Series Electronic Valve Actuator, Advanced Features

SAX Electronic Valve Actuator

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac 3-Position (Floating) Control

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control

Flowrite EA 599 Series SQX Electronic Valve Actuator 24 Vac, 3-Position Control

Flowrite 599 Series SKB/C Electronic Valve Actuator 24 Vac, 3-Position (Floating) Control

Flowrite EA 599 Series SKB/C Electronic Valve Actuator 24 Vac, 3-Position (Floating) Control

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

599 Series Zone Valves

SAX Electronic Valve Actuator

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Rebuild/Repack Kits for Flowrite VF 599 Series 2-1/2 to 6-inch Valves

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Proportional Control

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Floating Control

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Packing Replacement Kit for Flowrite VF 599 Series Valves

SAV Electronic Valve Actuator

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

Pressure Independent Control Series

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position)

Flowrite AP 599 Series

Pressure Independent Control Series

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Flowrite TM AP 599 Series 8-inch Pneumatic Valve Actuator

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

Flowrite 599 Series. Technical Bulletin. 1/2 to 2-Inch Valve (2-Way & 3-Way) and Actuator Assembly Selection. Document No.

Powers TM Controls SW 134 Pressure Electric Switch (Adjustable Differential)

Powers Controls 656 Powermite Valve with 3-inch Top Rebuilding

Flowrite 599 Series High Pressure Close-Off 2-Way Valves, 2-1/2 to 6-Inch, Flanged Iron Body, ANSI Classes 125 & 250

VE VVG Series Electronic Two-way Valves Normally Closed

Laboratory Exhaust Air Terminal

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Powers TM Controls EA 338 Electronic Actuator

TEC Actuator Package. Product and Part Numbers. Product Description. Installation Instructions Document No October 27, 2010 CAUTION:

599 Series Ball Valve and Actuator Assemblies Selection

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

SED2-BT300-XX-C09 Migration Kits. Product Numbers

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

Technical Data 1 /2 3 / /4 1 1 /2 2. Cv TABLE

Powers Controls Powertop Two-Way Valves Normally Open

Technical Instructions Document No P25 EA GMA May 19, OpenAir. GMA Series, Spring Return, 62 lb-in, Rotary, Electronic Damper Actuators

Pressure Independent Control Series 2-Way Valves and Electronic Valve Actuators

MF Series MS Series

599 Series Ball Valve and Actuator Assemblies Selection

Powermite 599 MT Series Terminal Unit Valve and Actuator Assembly Selection

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

Flowrite VF 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

Technical Instructions Document No P25 EA GMA January 19, OpenAir. GMA Series Spring Return Rotary Electronic Damper Actuators

OpenAir GCA Series Spring Return 142 lb-in Electronic Damper Actuators

Flowrite 599 Series Two-Way Valves 1/2 to 2-inch Bronze Body

Powers TM Controls RL 243 SW Switching Relay

Accessories/Kits Ball Valve Bracket Kit (includes bracket, mounting screws, shaft and handle)

Powermite 599 MT Series Terminal Unit Valve and Actuator Assembly Selection

599 Series 2-Way Ball Valves

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

SED2 Variable Frequency Drives

Master/Slave Actuators Spring Return Rotary 24 Vac - Modulating Control

Ball Valve Bracket Kit

599 Series Zone Valve Bodies:

Powermite 599 Series MT Series Terminal Unit Three-way Valves

SmartX MF and MS

Powers Controls Maximum Thrust Ratings of Pneumatic Damper Actuators

SCC Inc. VA Series. Technical Instructions. Document No. VA-3000 March 15, VA VKF Valve Actuator Assemblies with VKF Butterfly Valves

599 Series 6-Way Ball Valves

SQM5 Reversing Actuator with Analog Input Signal

OpenAir. Technical Instructions. GCA Series Spring Return 160 lb-in Electronic Damper Actuators. Document No P25 EA GCA-1.

MVF461H Series Modulating Control Valves with Magnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam

Series 1000 Room Temperature Sensors, 1K Ω Platinum (375α) RTD (MBC/RBC/MEC/UC)

Powermite 599 Series MT Series Terminal Unit Two-way Valves

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2

Powers TM Controls SW 141 Differential Static Airflow Switches

Ball Valve Bracket Kit

Room Temperature Sensors Series to 20 ma

POWERS TM CONTROLS LC Pneumatic Damper Actuator

SKP Series SKP15 U.. Gas Valve Actuator with Safety Shutoff Function

Powers Controls RL 147 Positioning Relay

Powers Controls No. 6 Damper Actuators Tandem Mounting

VVP45 and VXP45 Series Two-port and Three-port Seat Valves ANSI Class 250 Short-stroke Valves

RDG160TU Commercial Thermostat

599 Series 2-Way Ball Valves

Transcription:

Document No. 129-217 SKD U Electronic Valve Actuator Product Description The SKD U actuator requires a 24 Vac supply signal to control a Flowrite 599 Series valve with a 3/4-inch (20 mm) stroke. Mounting Positions Product Numbers Non-Spring Return Spring Return SKD60U SKD62U SKD82.50U SKD82.51U Warning/Caution Notations WARNING: Required Tools 5 mm Allen wrench Personal injury or loss of life may occur if you do not follow a procedure as specified. Equipment damage or loss of data may occur if you do not follow a procedure as specified. Small and medium flat-blade screwdrivers Expected Installation Time 20 minutes for factory-installed actuator 45 minutes for field replacement of actuator Prerequisites WARNING: If mounting the actuator to a valve already in line, either close the shut-off valves in the piping (upstream first, then downstream) or switch off the pump to allow the differential and static pressure in the valve to drop. Do not use in low pressure steam applications. Figure 1. Acceptable Mounting Positions. Using the Weather Shield The SKD must be in the vertical position. Complete instructions for the mounting of the Weather Shield are included with that product. NOTE: Use the top knockout position when installing the Weather Shield. See Figure 16. Figure 2. Weather Shield Installation Position. Installation If you are mounting an actuator on a new valve, begin with the instructions in Figure 3. Item Number: 129-217-04, Rev. CA Page 1 of 6

Document No. 129-217 Removing the Actuator from the Valve 1. Remove the actuator cover. 2. Disconnect the wires and conduit, if installed. 3. Loosen the valve stem retainer using a 5 mm Allen wrench and lower the valve stem into the valve. 4. Loosen the yoke nuts using a 5 mm Allen wrench in the actuator yoke. 5. Remove the actuator from the valve, being careful not to damage the valve stem. Continue with Mounting an Actuator to a Valve. Figure 6. NOTE: Hold the stem retainer in place as you tighten it around the valve stem. See Figure 6. 5 Figure 3. Preparing a new Valve. Mounting an Actuator to a Valve. 6 NOTE: Install the packing heating element, (P/N 599-00417), if used, before proceeding. 1 Figure 7. NOTE: Position the actuator to accommodate the wiring. Hold the actuator in place while tightening the yoke nuts. See Figure 7. Figure 4. 2 7 NOTE: Make sure the yoke nuts are loose enough to allow the actuator to slip over the bonnet. See Figure 5. 4 Figure 8. 3 Figure 5. Page 2 of 6 Siemens Industry, Inc.

Document Number: 129-217 Wiring Use care when removing the knockout. Do not damage the circuit board. Do not use autotransformers. Use earth ground isolating step-down Class 2 transformers. Determine supply transformer rating by summing total VA of all actuators used. The maximum rating for a Class 2 power supply circuit is 100 VA. Actuator Power Consumption Actuators Per Class 2 Supply Circuit* (80% of Transformer VA) SKD6 U 17 VA 4 SKD82.50U 13 VA 8 SKD82.51U 18 VA 5 * Operating more actuators requires additional transformers or separate 100 VA power supplies. Wiring Diagrams SKD60U/SKD62U Figures 9 and 10 SKD82.50U/51U Figures 11 through 13 SKD6 U Figure 10. Connecting Terminals G G0 Y Z M U 24 Vac System Potential (SP) System Neutral (SN) Control Input: 0 to 10 Vdc or 4 to 20 ma (DIP switch selectable) Override Control (See Technical Instructions 155-180P25) Measuring Neutral Output for 0 to 10 Vdc or 4 to 20 ma measuring voltage. It will match the input signal type. The position output signal U will switch from 0 to 10 Vdc to 4 to 20 ma when a 4 to 20 ma input signal is selected and used on the terminal Wiring for SKD82 U 1 2 Figure 9. SKD6 U. DIP Switches 1 Selection of Control Signal 2 Selection of Flow Characteristic ON 4 to 20 ma Modified* OFF (Factory Setting) 0 to 10 Vdc Default *Changing the default setting will modify an equal percentage valve to a linear flow characteristic. When set to default, the flow characteristic is determined by the valve body. Figure 11. Location of Terminals. Siemens Industry, Inc. Page 3 of 6

Document No. 129-217 Page 4 of 6 Figure 12. Non-Spring Return SKD82.50U. Connecting Terminals G System Potential 24 Vac (+) Y1 Outward movement of coupling piece (0 to 1) Y2 Inward movement of coupling piece (1 to 0) Cm1 Limit switch for 100% stroke c1 ASC9.3DU double auxiliary switch c2 ASC9.3DU double auxiliary switch 1000 W ASZ7.3 potentiometer The diagram shows all possible connections. How many and which are used depend on the application. Figure 13. Spring Return SKD82.51U. Connecting Terminals G System Potential 24 Vac (+) 21 System Neutral (SN) Y1 Outward movement of coupling piece (0 to 1) Y2 Inward movement of coupling piece (1 to 0) Cm1 Limit switch for 100% stroke c1 ASC9.3DU double auxiliary switch c2 ASC9.3DU double auxiliary switch 1000 W ASZ7.3 potentiometer The diagram shows all possible connections. How many and which are used depend on the application. Start-Up Check the wiring for proper connections. Consult Technical Instructions 155-180P25 for detailed commissioning information. Normally Closed Valve Actuator pressure cylinder moves: Outward (0 to 1): Valve opens. Inward (1 to 0): Valve closes. Normally Open Valve Actuator pressure cylinder moves: Outward (0 to 1): Valve closes. Inward (1 to 0): Valve opens. Three-Way Valve Actuator pressure cylinder moves: Outward: Valve opens between port NC and C. Inward: Valve opens between ports NO and C. NOTE: The valve body assembly determines the complete assembly action. Siemens Industry, Inc.

Document Number: 129-217 Manual Operation Dimensions Figure 14. Manual Override in Manual and Automatic Position. Each complete revolution (360 ) is equal to 3/32-inch (2.5 mm) stroke. Reference Technical Instruction Document Number Flowrite EA599 Series SKD Electronic Valve Actuator Proportional Control 155-180P25 Flowrite EA599 Series SKD Electronic Valve Actuator 3-position(Floating) Control 155-181P25 Figure 16. Dimensions of the 599-10071 Weather Shield in inches (mm). Figure 15. Valve Stem Travel Indication. Siemens Industry, Inc. Page 5 of 6

Document No. 129-217 Dimensions, Continued Be careful when removing the knockout. Do not damage the circuit board. NOTE: Use the top knockout position when installing the Weather Shield. SERVICE ENVELOPE MINIMUM ACCESS SPACE RECOMMENDED 4 inch (100 mm) 8 inch (200 mm) Figure 17. SKD U Dimensions in Inches (mm). Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Flowrite is a trademark of Siemens Industry, Inc. Other product or company names mentioned herein may be the trademarks of their respective owners. 2018 Siemens Industry, Inc. Siemens Industry, Inc. Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 USA Tel. +1 847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to sbt_technical.editor.us.sbt@siemens.com Document No. 129-217 Printed in the USA Page 6 of 6