Owners Manual. Features

Similar documents
Owners Manual. Features

Owner s Manual. Features

Installation and Operating Instructions

Installation and Operating Instructions

MODEL 235P INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 08/2009 II_235P_B1

MODEL 233P/111P/233P-1.5

MODEL 422 Submersible Pump Controller

INSTALLATION INSTRUCTIONS FOR SYMCOM MODEL 231-P-INSIDER

HP Volts Stages Discharge Head Length Brand S10P4HS /2 6 S10P4HS / " Sta-Rite S10P4HS Stainless Steel

SINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F

Electronic Products ELECTRONIC MAINTENANCE

CONSTANT PRESSURE CONTROLLERS

Application Engineering

ADVANCED PID TROUBLESHOOTING

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Application Engineering

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Pump Station. Models ADW2W31, ADW2W51, ADW2W71, ADW2W73

SOLAR SUBMERSIBLE PUMP CONTROLLER. SubDrive Solar. Installation Manual

REVISION HISTORY REVISION HISTORY

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Commander Pro Variable Speed Controller System Instructions

4" Motors and Controls

3 Phase Smart Controller

Centrifugal Constant Pressure Control

Submersible Pumps. 5'' CS Series Pumps

Centrifugal Constant Pressure Control

4" SUBMERSIBLE PUMP 4" SUBMERSIBLE PUMP. "GS" series. "ST" series. "SL" series. ST Series (stainless steel) SL Series (thermoplastic)

FHOTON Drive. Installation Guide

franklinwater.com 50 Hz 6" STS SERIES Submersible Turbine Pumps

Commander Pro Variable Speed Controller System Instructions

CONSTANT PRESSURE CONTROLLERS

INSTRUCTION MANUAL IM260 AQUAVAR SOLO 2 CONSTANT PRESSURE CONTROLLER INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Flow-Thru Expansion Tanks

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

CBC-9130 / V 30A / 24V 15A Pro. Charger. Operation manual

Service Manual. For the SCV2832E, SCV2426, Automatic Scrubbers For: Training Troubleshooting

Easy touch Pump Control

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Franklin Electric Submersible Motors SUBMERSIBLE MOTORS. Motors Accessories. Product Information and Service

SOLAR SUBMERSIBLE PUMP CONTROLLER. SubDrive Solar. Installation Manual

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

PowerOhm Installation Manual for BM R Series Braking Modules

Pump controller and protection for one pump Multicontrol. +info: INSTALLATION AND OPERATION. Mod. Vigilec mini (V1N)

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

R & D SPECIALTIES ROTROL I USER'S MANUAL

Centrifuge Operator / Service Manual

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

KD LV Motor Protection Relay

E Series CE Approved Intermittent Pilot Ignition Control

Product Guide: Series III Pump Control Board Set (RoHS)

TRIPS AND FAULT FINDING

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

PPC3 & PPC5. State-of-the-art pump protection and controllers

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

P445 Series Electronic Lube Oil Control

FHC-1D user manual. Features

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER SOLAR REGULATOR!

TDX - Taco Duplex Starter with

ACCESSORY KIT INSTALLATION INSTRUCTIONS

PHOENIX Amp Brushless Sensorless Speed Control. 1.0 Features of the Phoenix-25 : 2.3 Connecting the Motor. 2.4 Reversing Rotation

OUTDOOR UNIT CONTROLLER (OUC)

AL-KO ESC USER MANUAL

SubDrive Inline Constant pressure controller Additional information for Australia, NZ TOLL FREE HELP 1300 FRANKLIN

GRD502-B Flow Chart 02/05/09

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

PowerOhm Installation Manual for LG ATV Series Braking Modules

316 Stainless Steel Submersible Pumps 8" 10" 12"

Application Engineering Europe

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

SubDrive75/100/150/300 MonoDrive, MonoDriveXT

The POWER. In PRESENTATION PRODUCTS. Instruction Book for BOARDROOM ELECTROL DA-LITE SCREEN COMPANY, INC.

Boston Gear Ratiotrol

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

Trouble Shooting Guide EWA, 3-phase (D2422)

Installation & Operating Manual

Table of Contents. 4 Submersible Pumps

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

PHOENIX HV Features of the Phoenix HV-45 : 2.3 Connecting the Motor. 2.4 Reversing Rotation. 2.5 Connecting the Receiver

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

GLM SERIES CONTROL Users Manual Rev:

PHOENIX Features of the Phoenix-25 : 2.3 Connecting the Motor. 2.4 Reversing Rotation. 2.5 Connecting the Receiver

User s Manual. Automatic Switch-Mode Battery Charger

SERVICES INDUSTRIELS SAVARIA INC. OWNER S MANUAL BATTERY OPERATED B.07 G

C.E. Niehoff & Co. C840D Alternator Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

franklinwater.com 50 Hz 4 SUBMERSIBLE PUMPS

PHOENIX Features of the Phoenix-10 : 2.3 Connecting the Motor. 2.4 Reversing Rotation. 2.5 Connecting the Receiver

AeroVironment Universal Solar Pump Controllers

SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS

CONTROLLER DIAGNOSTIC GUIDE

BrAC Audit Lock-1 Instruction User Manual

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Transcription:

Owners Manual Pumptec is a microcomputer based pump protection device that continuously monitors motor load and power line conditions to provide protection against dry well conditions, waterlogged tanks, and abnormal line voltage conditions. Indicator lights provide complete system status, which can be easily viewed without removing the cover. Pumptec interrupts power to the motor whenever the motor load drops below a preset level or the load drops quickly. Pumptec is optimized optimised to work only with with Franklin 2 and & 3-wire 3 wire single phase motors submersible from 1/3 to 1-1/2 motors HP. from An underload 0.37 to 1.1 (dry kw. An well) underload adjustment (dry is well) provided adjustment to address is provided unusual situations. to address unusual situations. Features Protection Features Dry Well (Underload) Over & Under Voltage Rapid Cycle Bound Pump Indicator Lights Load Voltage Status Remote Control Features Over & Under Load Settings Over & Under Voltage Settings Reset Time Settings Fault History (Last 15 Faults) System Status Monitor Other Features Heavy Duty Relay 115V/230V 50/60Hz Operation Alarm Circuit Contacts

Technical Specifications: Model Number 5800020600 kw Horsepower Rating Rating 0.37 1/3 to to 1.5 1.1 (1/3 to 1.5hp) Voltage Rating 115V/230V Frequency 50/60Hz Power Consumption 4W Response Time 3 Seconds Reset Time 2 to 120. (240. w/remote) Type Single Phase Induction Run Alarm Contact Rating 1 Amp 115V/230V Over/Under Voltage Time-out 2 utes Operating Temperature Range -26ºC -15ºF to 130ºF 54ºC (-15ºF to 130ºF) Note: Pumptec is not designed for use on permanent split capacitor (PSC) motors. Dry well protection occurs when pump suction is broken. Deadhead conditions may not always be detected due to variation in pump load characteristics Installation Instructions 1. Remove the cover from the Pumptec. 2. If you will be running a 1.5HP 1.1kW motor, move the circuit board jumper to the 1.1kW 1.5HP position as shown in Figure 1. More 70% Sensitive 80% 60% 90% 40% Underload Trip %SFL 30 60 15 120 2 Timeout 1/3HP 1HP 1 HP (0.37 Setting - 1.1kW) Setting (Factory (Factory default) default) 1.5HP HP(1.1kW) Setting Figure 1: Circuit board jumper for 1.5HP motors (1.1kW) motors 2

3. Mount the unit in a location convenient for wiring. 4. Turn off power at the AC source. 5. Pumptec may be wired upstream or downstream of the control switch for 2-wire and 3-wire motors. Select an installation option from figures 2A and 2B. Pumptec to Control Switch Pump Control Switch to Pumptec Pump Figure 2A: 2-Wire Installation Options to to Pumptec to Control Switch to Control Box Pump Control Switch to Pumptec to Control Box Pump Figure 2B: 3-Wire Installation Options 3 3

6. Connect wires to the Pumptec as shown in Figure 3. Power is connected the same way regardless of the line voltage. Alarm Contacts Fault Contact Alarm Alarm (1 A Max.) 115V or 230V From power source or control switch Figure 3: Wiring Connections To 2-wire or 3-wire control box 7. Set the time-out adjustment to the desired position. The factory setting is 30 utes, see Figure 4*. More 60% 40% Sensitive 70% 80% 90% Underload Trip %SFL Underload sensitivity (Full clockwise for remote) Factory setting = 70% 15 2 30 Timeout 60 120 Reset time adjustment (Full clockwise for remote) Factory setting = 30 utes Figure 4: Timeout and Trip Sensitivity Settings 8. The factory underload setting of 70% should not require any adjustment. 4

9. Wire in alarm circuit, if desired. 10. Replace cover and secure cover screw. 11. Turn AC power back on. *Note: If you will be using IR remote control to set the underload and the time-out settings, set the appropriate adjustment knobs to the Remote position (fully clockwise position). See Figure 4. The initial remote settings are the same as the factory presets - 70% for underload and 30 utes for the underload timeout. The underload adjustment is preset at the factory to detect underload (dry well) conditions on most systems. In general, there is no need to adjust this setting. Operation Pumptec has three indicator lights labeled POWER, LOAD and VOLTAGE. If the Pumptec is connected upstream of the pressure switch, the system status can be detered from these indicator lights at any time. When wired down stream of the control switch, no status will be displayed when the control switch is open. Power Indicator Light If solid, the Pumptec has power and the system is idle. In this state, the motor is not running and the Pumptec is waiting for the control device (i.e. pressure switch) to close and turn on the motor. When flashing, the system is pumping water and running normally. Load Indicator Light When the load light is solid, a dry well (underload) condition has occurred. The Pumptec will wait the duration of the reset time-out period before attempting to restart the motor. A The flashing yellow load load light light indicates an one overload of the condition three conditions: has occurred. 1. A solid yellow light with no flicker indicates a dry well (underload). This is caused by the load of the motor going below the underload adjustment knob. (If you have a Pumptec remote control, this wil be indicated by underload in the Pumptec Fault History.) 2. A solid yellow light with a slight flicker indicates an underload caused by a rapid decrease in load (approximately 25% over a twenty second period). (If you have a Pumptec remote control, this will be indicated by underload* in the Pumptec Fault History). Note: In both conditions above, the Pumptec will wait until the reset time-out period has ended before attempting to restart the motor. 5

3. A flashing yellow light (on for 1/2 second, off for 1/2 second) indicates an overload caused by the motor current being excessively high. The unit must be manually reset by removing power for 10 seconds. (If you have a Pumptec remote control, this wil be indicated by underload in the Pumptec Fault History.) A flashing load light t* indicates an an overload condition has occurred. The unit must be manually reset by by removing power for 10 10 seconds. An overload condition occurs when the motor current has become excessively high. Voltage Indicator Light When the voltage light is solid, an under voltage condition has been detected. The under voltage trip is factory preset to 203 volts. The remote control feature may be used to alter the under voltage trip point. When the voltage light is flashing, an over voltage fault has been detected. The over voltage trip is factory preset to 253 volts. The remote control feature may be used to alter the over voltage trip point. After a voltage fault has occurred, Pumptec will check the line voltage every two utes and will reset when the line voltage returns to the normal range. Load & Voltage Indicator Lights Flashing When both the load and voltage indicator lights are flashing together together, a Rapid Cycle condition has occured. The Pumptec will wait the duration of the reset time-out period (either the factory preset time (30 utes) or the time set using the underload time-out adjustment knob by the user) before attempting to restart the motor. *Note: The Rapid Cycle trip criteria is 4 starts per ute. The Pumptec must be wired before the pressure switch to activate the Rapid Cycle feature. 6

Troubleshooting Remote Control A Pocket PC with an infrared port may be used to monitor the motor/ pump system performance and adjust the Pumptec trip points. When dealing with unusual installations, the system monitor and underload adjustment remote control features allow quick diagnosis of system problems. No Lights No power is applied to the Pumptec. Check for voltage at the and connections. If Pumptec is wired downstream of the control switch, the control switch may be open. Solid Load Light Pumptec has detected a dry well or underload condition. A. Make sure the pump and motor are matched correctly. B. Check for a blocked pump intake or stuck check valve. C. The coupling between the motor & pump may be stripped. D. Blocked plumbing or stuck check valve may be causing a deadhead condition. E. The underload sensitivity knob may be adjusted in cases where the unit is too sensitive. After adjustment, check to ensure insure the unit still is able to detect a dry well condition. Flashing Load Light The system is drawing excessive current. A. The motor is stalled or there is a ground fault. Solid or Flashing Voltage Light The line voltage is too high or too low. A. An unloaded generator can cause a high line condition. B. Low line conditions can be caused by loose connections. C. Report persistent high or low line voltages to the power company. Flashing Voltage & Load Lights Rapid Cycle condition has occurred. A. Check for a waterlogged pressure tank. B. A bobbing float switch may cause rapid cycling. 7

Franklin Electric (Aust) Pty Ltd 106-110 Micro Circuit Dandenong South, Vic 3175 Tel: +61 3 9799 5000 Toll Free: 1300 FRANKLIN 1300 372 655 franklin-electric.com.au TOLL FREE HELP FROM A FRIEND Phone Franklin s toll-free Submersible SERVICE HOTLINE for answers to your installation questions. When you call, a Franklin expert will offer assistance in troubleshooting your pump protection system and provide immediate answers to your motor application questions. FE735 1/12 M1502 09/08