Selection Selection Information General The Racor Marine Diesel Spin--on Series feature a variety of compact sizes to fit most installations and cramped engine compartments. Mounting Heads: These units feature multiple fuel ports and many have more than one inlet or outlet. All have a unitized mounting bracket. The and Series heads feature a built--in, hand operated fuel priming pump to simplify servicing procedures. Filters: All units feature spin--on replaceable filters and contaminant collection bowls except for the high--pressure A. All units may be specified with an in--bowl water probe when used with diesel or kerosene applications. High--capacity Aquabloc t filter elements stop water and remove solid contamination. A micron filter (or secondary and even final) is used to filter fuel which is known to be of good quality. A micron filter, used with the R model, (or final filter) is the finest filtration available and is the last filter used prior to engine ingestion. A simple rule to remember is the finer the filtration, the more frequent the filter change. (Carry extra filters on board). Reusable Collection Bowls: The metal bowls used with these models feature an NPT tapered thread plug for removing contaminants. An optional UL. Listed shut--off drain valve may be ordered to simplify servicing. Options --Available for Diesel fuel systems only. Water Probe RK9. When used with a Racor Water Detection Module, the operator can be alerted of a high--water condition, even while the equipment is operating. The bowl is then drained of water at the earliest convenience. Note: A Racor Water Detection Module is needed to work with this probe. See Accessories. Water Probe RK. Same features as above, except the or vdc electronic detection module is built--in the probe housing. Includes a detachable connector. See Accessories. Danger! Do not use water probes with gasoline applications. This could cause an explosion. SELECTION. Along with the information you obtained in SECTION, SELECTION (page 9), consider the following: Are there any space limitations in the available location? The location should provide adequate space for removing the element, draining off contaminants from the bowl (and operating the primer pump on and Series models).. What filtration rating is needed?, or micron?. What options are needed? Water probe and/or a bowl shut--off drain valve? Using this information, select a unit from the next page, or check the models which follow to find the right unit for your application. For additional information, call your Racor dealer or call Racor customer service at (9) --7 or () --, : AM to : PM, Pacific Time, or e--mail us from our website, www.parker.com/racor.
Introduction Model Illustrations A RMAM RMAM Series Special Notes MAM Series. Above units feature metal bowls and are approved for diesel service and are UL Listed, USCG Accepted.. Model A may be used in pressure applications (up to PSI) and gasoline service. UL Listed.. The RMAM and MAM Series units include the head mounted hand priming pump as standard.. The MAM model features large / UNF ports for high--flow, low--restriction applications.. Allow at least inches ( mm) clearance under the units for element replacement and water collection.. For additional information and availability, contact customer service: () --, AM to PM, Pacific Time. Specifications BASIC MODELS A RMAM RMAM RMAM RMAM MAM MAM 9MAM MAM Maximum GPH / 9 Flow Rate LPH 7 / 7 7 7 7 7 Port Size / NPT / NPT / NPT / NPT / NPT / NPT / NPT / NPT / UNF Number of Ports Filter Element RT RSUL RTUL RTUL RTUL STUL STUL STUL STUL Center threads N/A M X. -- -- -- -- -- -- -- Height in./mm /.7/./ 9./9./7 9./9./././ Width in./mm././ / / /././././ Depth in./mm././ / / /././././ Weight Lbs./kgs../.9./.9./. /.9./.9/../../../. Clean PSI......7... Press.Drop kpa.......7.. Max.Allowable PSI 7 Pressure kpa 9 7 7 7 Bowl Water Capacity ml Operating Temperature -- _ / +_ F / -- _ / +_ C Flow rate for gasoline applications.
Models A A Basic Model GPH Diesel / GPH Gasoline Two piece die--cast aluminum construction. Mounting Hole Pattern Replacement Service Element SERVICE ELEMENT INCLUDES LID SEAL. RT Micron -Recommended for Primary or Secondary* Filtration *Consult engine manufacturer or Racor Distributor. --Refer to Diesel Spin--on Series introduction page for filter dimensions.. ( mm) Head Top View. Fuel ports are: / -- NPT (SAEJ7).. ( mm) / ( mm) diameter clearance for fasteners. (Not to scale) A SAE J9 Water Separation..... 9 SAE J9 Fuel Flow Restriction *PSI X. = inhg. / PSI X.9 = kpa SAE J9 Solids Capacity (using SOFTC--A; RT Element) Parts List The circled number corresponds to the item number shown in the parts list below. RK A Head, / NPT Ports RK Metal Vent Plug, / -- UNF RK A Housing RT Replacement Element RK Metal Plug, / -- UNF RK A Gasket/O--ring Kit Installation Instructions
Model RMAM RMAM Basic Model GPH Head and bowl are die--cast aluminum. Mounting Hole Pattern Replacement Service Element SERVICE ELEMENT INCLUDES SEALS. RSUL Micron -Recommended for Secondary (Final) Filtration *Consult engine manufacturer or Racor Distributor. --Refer to Diesel Spin--on Series introduction page for filter dimensions. Head top view. Fuel ports are: / -- NPT (SAEJ7).. ( mm). ( mm) / ( mm) diameter clearance for fasteners. (Not to scale) RMAM.... SAE J9 Water Separation. 9 SAE J9 Fuel Flow Restriction *PSI X. = inhg. / PSI X.9 = kpa SAE J9 Solids Capacity (using SOFTC--A; RT Element) Parts List 7 The circled number corresponds to the item number shown in the parts list below. RK7 Head, / NPT Ports RK Head Bolt Assembly RK Metal Vent Plug, / -- UNF RSUL Replacement Element Micron, UL Recognized RK Bowl O--ring RK9 Metal Bowl 7 RK Metal Plug, / -- UNF 9--N Steel Drain Plug, / NPT RK Metal Plug, / NPT RK Gasket/O--ring Kit Installation Instructions, RMAM 7
Model,, RMAM RMAM RMAM: GPH RMAM: GPH RMAM: GPH Includes primer pump and metal bowl. Mounting Hole Pattern (Not to scale) RMAM shown All models Replacement Service Element SERVICE ELEMENT INCLUDES SEALS. use RTUL ( Micron) /case use RTUL ( Micron) /case use RTUL ( Micron) /case (mm). (mm) (mm) SAE J9 Water Separation --Refer to Diesel Spin--on Series introduction page for filter dimensions. / ( mm) diameter clearance for fasteners.. ( mm) Head top view. Fuel ports are: / -- NPT (SAEJ7). RMAM shown..... SAE J9 Fuel Flow Restriction *PSI X. = inhg. / PSI X.9 = kpa SAE J9 Solids Capacity (using: SOFTC--A; mic.elements) Parts List R. (mm) R. mm) R. mm) The circled number corresponds to the item number shown in the parts list below. 7 9 RK Head, / NPT Ports RK Primer Pump Assembly RK Check Ball and Plastic Cap RK7 Metal Check Ball Cap RK Metal Vent Plug, / -- UNF RK Metal Plug, / NPT See Replacement Service Element box above 7 RK Bowl O--ring RK Beige Metal Bowl (with / NPT drain and / -- probe ports) 9 RK Metal Plug, / -- UNF 9--N Steel Plug, / NPT RK Complete Gasket/O--ring Kit Installation Instructions, Series
Models,, 9, MAM How to Order -The example below illustrates how the part numbers are constructed. MAM MAM: GPH MAM: GPH 9MAM: 9 GPH MAM: GPH The powder coated head includes a hand primer pump with inlets & outlets. The metal bowl is standard. P Water Probe: Specify P for an in--bowl water probe. (Racor part number RK9). Omit P if not desired. Element Filtration Rating: These units are standard with a micron element. Add to the part number. Order a water detection module separately from the Marine Accessories Section. Replacement Service Elements -Service elements include seals. MAM use STUL ( Micron) per case MAM use STUL ( Micron) per case 9MAM use STUL ( Micron) per case MAM use STUL ( Micron) per case 9MAM SAE J9 Water Separation Mounting Hole Pattern / Parts List / ( mm) diameter clearance for fasteners.. (7 mm) Head top view. All models.7 ( mm). /9 / 9/ / 9..... 9 SAE J9 Fuel Flow Restriction *PSI X. = inhg. / PSI X.9 = kpa 7 9 9/ The circled number corresponds to the item number shown. 9 SAE J9 Solids Capacity (using: SOFTC--A; mic.elements) RK Mounting Head, / NPT RK7 Mounting Head, / UNF RK Vent Plug (metal) SP--S Metal Plug, / NPT STUL Service Element, micron STUL Service Element, micron STUL 9/ Service Element, mic. RK7 Bowl O--ring RK9 Beige Metal Bowl, / NPT & / UNF Ports 7 RK Metal Plug, / -- UNF RK9 Water Probe, / -- UNF 9 RK Water Probe with Electronics 9--N Steel Plug, / NPT RK99 UL Listed Marine Shut--off Valve 9 Installation Instructions, Series Use with water detection module. See Accessories Section.