ew Series PS6R 4W Switching Power Supply Reduced size and high efficiency cuts operating costs. Energy-saving 93% Efficiency Space-saving 85mm wide Efficiency (%) 96 94 92 88 86 84 82 Competitor A Competitor B 5 15 2 25 3 Input Voltage (V AC) Wide Operating Termperature Range 7 Operates without derating at to 6ºC 6 5 4 3 Operates at to 7ºC 2 2 3 4 5 6 7 Easily Expandable Only 85mm Operating Temperature ( C) Easy Maintenance - ED Indicator Status ormal Overload or Input Voltage ow* short-circuit OFF In addition to the single output, an additional W output can be added. (See ote 1 on page 2.) Two terminals can be added. o wiring is required, reducing installation space. DC O (green ED) DC ow (amber ED) *The EDs turn on when the input voltage drops.
PS6R Switching Power Supplies High-power and space-saving switching power supplies. 93% efficiency reduces operation costs. Input voltage: to 24V AC (voltage range: 85 to 264V AC/1 to 35V DC) The terminals are captive spring-up screws. Ring or fork terminals can be used. Finger-safe prevents electric shocks. Panel mounting bracket and side-mounting panel mounting bracket. Can be attached to a DI rail or directly to a panel surface. CE marking (VD, EMCD) U58, c-u (CSA C22.2 o.7.1), TÜV (E695-1, E5178). E6124-3 (Electromagnetic compatibility Class B) Applicable Standards Mark File o. or Organization U58 CSA C22.2 o. 7.1 C ISTED US U/c-U isted File o. E177168 E695-1 E5178 E6124-3 TÜV SÜD EU ow Voltage Directive EMCD Part umbers PS5R Package Quantity: 1 Capacity* Part o. Input Voltage Voltage Current 4W to 24V AC 21.6 to 26.4V 2A * voltage output current output capacity Accessories Package Quantity: 1 Item Part o. ote 1 PS9Z-6RM2 : +12V, 1A, 12W PS9Z-6RM1 : +5V, 2A, W PS9Z-6RM5 : +5V, 1A/+12V,.5A, 11W 2 PS9Z-6RS1 Additional screw terminals for wiring: 2 + terminals / 2 - terminals Panel Mounting Bracket PS9Z-6R1F Side-mount Panel Mounting Bracket PS9Z-6R2F Supplied with M3 6 countersunk mounting screws DI Rail BD 1,mm DI Rail End Clip B5 1. When using a DC-DC converter unit, reduce 1A from the output current of PS6R. 2. When using a branch terminal unit, the total voltage/current of PS6R and the branch terminal unit should not exceed the rated current/voltage of PS6R. Reference Value Expected ife 8 years (7, hours) minimum (at the rated input, duty ratio 5%, operating temperature +4 C, standard mounting direction) Calculation of the expected life is based on the life of the aluminum electrolytic capacitor. The expected life is subject to operating conditions. 2
PS6R Switching Power Supplies Specifications PS6R Part o. to 24V AC Input Voltage (Voltage range: 85 to 264V AC/1 to 35V DC) (oad % at 85 to V AC, 1 to 14V DC) (ote 1) Frequency 5/6Hz Input Current V AC 5.5A typ. 23V AC 2.3A typ. Inrush V AC 9A max. (Ta=25ºC, V AC cold start) Current 23V AC 2A max. (Ta=25ºC, 23V AC cold start) eakage 12V AC.5mA max. Current 23V AC 1mA max. Efficiency V AC 91% (Typical) 23V AC 93% Power Factor V AC.98 (Typical) 23V AC.97 Rated Voltage/Current 24V/2A Adjustable Voltage Range ±% Holding Time 2ms min. (at rated input and output) Start Time ms max. (at rated input and output) Rise Time 2ms max. (at rated input and output) Total Fluctuation ±5% max. Input Fluctuation.4% max. Regulation oad Fluctuation.6% max. Temperature Change.5%/oC max. ( to +6ºC) Ripple (including 1% p-p max. ( to +6ºC) noise) 1.5% p-p max. ( to ºC) Input Supple-mentary Functions Dielectric Strength Overcurrent Protection 5 to 12% (auto reset) (output current when voltage drops by 5%) Overvoltage Protection off at 12% (ote 2) Operation Indicator ED (green) Voltage ow Indication ED (amber) Between input and output terminals 3V AC, 1 minute Between input and ground terminals 2V AC, 1 minute Between output and ground terminals 5V AC, 1 minute MΩ min. 5V DC megger (between input and output terminals/between input and ground terminals) (at room temperature and normal humidity) Insulation Resistance Operating Temperature to +7ºC (no freezing) (ote 3) Operating Humidity 2 to % RH (no condensation) Storage Temperature 25 to +75ºC (no freezing) Storage Humidity 2 to % RH (no condensation) to 55 Hz, amplitude.375 mm (.187mm using Vibration Resistance PS9Z-6R1F) 2 hours each in 3 axes, 6 directions Shock Resistance 3 m/s 2 (15 m/s 2 when using a PS9Z-6R1F panel mounting bracket) EMC EMI E6124-3 (Class B) EMS E6124-3 (industrial) Degree of Protection IP2 (IEC 6529) Weight (approx.) 14g Terminal Screw M3.5 (See last page for wire size.) ote 1: DC input voltage is not subjected to safety standards. ote 2: One minute after the output has been turned off, turn on the input again. ote 3: See the output derating curves. Accessories (For use with PS6R) Part o. Input Voltage PS9Z-6RM1 PS9Z-6RM2 PS9Z-6RM5 PS9Z-6RS1 Capacity W max. 12W max. 11W max. Supplementary Functions 24V DC Rated Voltage/Current 5V/2A 12V/1A 5V/1A, 12V/.5A 24V/A max. (ote 1) Adjustable Voltage Range ot available Voltage Accuracy ±5% max. Start Time 2 ms max. (at rated input and output) Regulation Input Fluctuation oad Fluctuation Temperature Change Ripple (including noise) Overcurrent Protection.5% max. 1.% max..5%/max. ( to +6 C) mv max. 15mV max. mv max., 15mV max. 5% (auto reset) Overvoltage Protection off at 12% (ote 2) Operating Temperature to +7 C (no freezing) (ote 3) Operating Humidity 2 to %RH (no condensation) Storage Temperature 25 to +75 C (no freezing) Storage Humidity 2 to % RH (no condensation) Vibration Resistance to 55 Hz, amplitude.375 mm, 2 hours each in 3 axes, 6 directions (in combination with ) Shock Resistance 3 m/s 2 (15 m/s 2 when using a PS9Z-6R1F panel mounting bracket), 3 shocks each in 6 axes (in combination with ) EMC EMI E6124-3 (Class B) (in combination with ) EMS E6124-3 (industrial) (in combination with ) Safety Standards U58 (isting), CSA C22.2 o.7.1, IEC/E695-1, E5178 (in combination with ) Degree of Protection IP2 (IEC 6529) Weight (approx.) g 3g Terminal Screw M3.5 (See last page for wire size.) ote 1: Ensure that the current does not exceed the rated current of the PS6R. ote 2: Repair is needed when output drops due to overvoltage protection. Contact IDEC. ote 3: See the output derating curves. 3
Dimensions (mm) 9.3 -M3.5 Terminal Screws A A 125 4 6.5 35.3 44.9 125 A A A A A A 85 A = 9.5 3.8 4.5 PS9Z-6R1F Panel Mounting Bracket When a PS9Z-6R1F is installed on PS6R 28 4-M4 or ø4-4.5 holes 23 23 13.6 (Front view) (Side view) PS9Z-6R2F Side-mount Panel Mounting Bracket 56 When a PS9Z-6R2F is installed on PS6R 4-M4 or 4-ø4.5 holes 87.3 29.5 31 138.5 148.6 138.5 148.6 11.8 135 145 135 145 28 39 28 Panel cut-out 4-M4 or ø4-4.5 holes 56 7 When using a PS9Z-6RM* 56 Panel cut-out When using a PS9Z-6RS1 (Front view) 11.8 (Side view) Mounting Screws (M3 6 countersunk screw) 59 59 53 34.4 9.3 9.6 Mounting Screws 7.2 Mounting 27.8 Screws 21 33.4 6 4
PS6R Switching Power Supplies Parts Description PS6R-6RM* PS6R-6RS1 /PS9Z-6RS1 Marking ame Description, Input Terminal Voltage range: 85 to 264V AC/1 to 35V DC (PS6R-6RM5 shown) Ground Terminal Be sure to connect this terminal to a proper ground., DC Terminals : Positive output terminal : egative output terminal VR.ADJ Voltage Adjustment Allows adjustment within ±%. Turning clockwise increases the output voltage. DC O Operation Indicator (green) ights on when the output voltage is on. DC OW ow Indicator (Amber) ights on when the output voltage drops approximately % of the rated value. DC OK DC OK ights on when the output voltage is more than % of the rated value. P transistor output (5V DC max., 5 ma max.) PS9Z-6RM Marking ame Description +5V, +12V DC Terminal +5V side, +12V side COM DC Terminal V side (wired internally to of PR6R-J24) Characteristics Operating Temperature vs. Current (Derating Curves) 7 6 5 4 3 2 2 3 4 5 6 7 Operating Temperature (ºC) Current vs. Input Voltage (Derating Curves) PS9Z-J24 (Ta=25ºC) 7 6 5 4 3 2 (ACV) 85 (DCV) 114 Input Voltage(V) 264 35 Voltage (%) Overcurrent Protection Characteristics 5% Pulse Current (Approx. 3A rms, 4A peak) Input Current (%) Overcurrent Protection Characteristics PS9Z-6RM 12% 95% 7 6 5 4 3 2 (ACV) 85 (DCV) 114 Input Voltage(V) 264 35 Operating Temperature approved by Safety Standards Part o. U58, CSA C22.2 o. 7. 1 E695-1, E5178 55ºC 6ºC PS9Z-6R 55ºC 6ºC 5
Operating Instructions The PS6R should be placed in a proper enclosure. It is designed to be used with general electrical equipment and industrial electric devices. Operation otes 1. interruption may indicate blown fuses. Contact IDEC. 2. The PS6R contains an internal fuse for AC input. When using DC input, install an external fuse or DC input. To avoid blown fuses, select a fuse in consideration of the rated current of the internal fuse. Rated Current of Internal Fuses Part o. Internal Fuse Rated Current A -- Avoid overload and short-circuit for a long period of time, otherwise internal elements may be damaged. -- DC input operation is not subjected to safety standards. Installation otes The PS6R can be installed in the direction shown below only. Up Vertical When using PS9Z-6R1F Panel Mounting Bracket When using PS9Z-6R2F Side-mount Panel Mounting Bracket Do not close the top and bottom openings of the PS6R to allow for heat radiation by convection. Maintain a minimum of 2mm clearance around the PS6R, except for the top and bottom openings. When derating of the output does not work, provide forced air-cooling. Make sure to wire the ground terminal correctly. For wiring, use wires with heat resistance of 6ºC or higher. Use copper wire of the following sizes. AWG18 to 14 (cross section.75 to 2. mm 2 ), 2-wire (solid/stranded) or AWG12 (cross section 3.3 mm 2 ), 1-wire (solid/stranded) with Uapproved crimp terminal ote: Wires of the above size must be used to comply with U58, CSA C22.2 o. 7.1. Applicable Crimp Terminal (reference) 6.6 max. 4 max. ø3.6 min. 5.5 min. Recommended tightening torque of the input and output terminals is.8 m. The output voltage can be adjusted within ±% of the rated output voltage by using the V.ADJ control. ote that overvoltage protection may work when increasing the output voltage. When large shocks or heavy vibrations on the PS6R are expected, the use of DI rail or PS9Z-6R2F side-mount panel mounting bracket is recommended. Series Operation The following series operation is allowed. Connect Schottky barrier diodes as shown below. DC-DC converter unit cannot be connected in series. oad oad (a) (b) Select a Schottky diode in consideration of the rated current. The diode s reverse voltage must be higher than the PS6R s output voltage. Parallel Operation Parallel operation is possible to increase the output capacity. DC-DC converter unit cannot be connected in series. oad When increasing the capacity, observe the following. 1. Maintain the operating temperature below 4ºC. 2. cannot be connected directly in parallel operation. Connect a diode to the output of each PS6R. 3. terminal voltage of both power supplies must be the same. Also, maintain the voltage difference between the power supplies below 3mV. 4. Use load lines of the same diameter and length. 5. Set the output voltage higher for the amount of diode forward voltage drop. 6. Turn on the inputs at the same time. 7. Select a diode in consideration of: Diode s reverse voltage must be higher than the PS6R s output voltage. Diode s current must be three times the PS6R s output current. Provide a heat sink for heat dissipation. oad IDEC Corporation 1175 Elko Drive Sunnyvale, CA 9489-262-IDEC (4332) Fax: 48-745-5258 www.idec.com/usa 213 IDEC Corporation. All Rights Reserved. 5/13 PDF only