Specification. Nomial Voltage Nomial Capacity(10HR) Dimension. Approx Weight Terminal Container Material Max. Discharge Current Internal Resistance

Similar documents
PbSO 4 + 2H2O + PbSO4 Lead Sulfate Positive Plate Active Material

AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X LED-400-T

Lead Acid Batteries competes in modern time

Features and Benefits

Solar-Wind. Solar-Wind Hybrid LED Street light. Advantages and Benefits

Batteries and more. Powered by (CE, UL & ISO9001 APPROVAL)

Wide operating temperature range: Our battery will operate from -30C to (-22F) to 60C when it is fully charged.

Nominal Voltage. Capacity (C20)

AINO MICRO RANGE VRLA. Compact energy for increased security BATTERY SOLUTIONS. EverExceed power your applications

1. Production Features

SEC. MICROLYTE +Plus. Industrial Battery Co. Supplied Worldwide by: Visit our website on Features. Application

Charging of HOPPECKE OPzV solar.power battery in Solar Applications

CYCLE LIFE 12V 5AH LITHIUM ION BATTERY RB5 LITHIUM ION BATTERY CAPACITY AT DIFFERENT CYCLES AT 100% DOD 99.

KPM type Intended for medium discharge currents from 0.5 to 2 C

General Catalogue VRLA-AGM, VRLA-GEL and Stationary Batteries

LinkData LiFeP04 Battery Catalog

Haze Battery Company Ltd

Chek-A-Cell TM TestEquipmentDepot.com. Instruction Manual Rev A 8/12

Company Introduction. Established: YEARS. Investment: More than 30 million US Dollar. Factory Area: 220,000 square meter.

Panasonic NCR18650B 3400mAh (Green)

CALL FOR A QUOTE (877)

TORKEL 840/860. Battery Load Units TORKEL 840/860

KCA SOLAR POWER GENERATING COMPANY LTD.

MHR VRLA batteries are manufactured in compliance with TL, NEBS, GR, SR, IEC, BS, UL, ISO, OSHAS and CE quality and performance standards.

BC-1230P/ 1240P/ 1260P Multi-Stage Battery Chargers User Manual

LC-QA Dimensions(mm) Duration of discharge vs. discharge current

Lithium iron Phosphate Battery Specification

Sales Brochure +44 (0) Quality in Every Language +44 (0)

UPS FEATURES & BENEFITS TECHNICAL DATA Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications.

SPG-400. Solar-powered generators

Chek-A-Cell TM. Instruction Manual Rev A 8/12

Energy Storage. Electrochemical Cells & Batteries

PowerStor Standby Battery Systems

Features: Applications:

Battery Storage Systems

Specification. Cylindrical Li-ion battery. Type: Product model battery VER A Product Specification 3. 6 V 2600 mah

FEATURES & BENEFITS. 10 year design 25 C

list in Sealed Lead Acid ( SLA )batteries from Japan more than 150,000 units of batteries every month on

Features: Applications:

DJMSERIES-General Purpose

bosfa spiral lead acid battery

Features: Applications:

2 Volt AGM Range. Haze Battery Company Ltd

QL0020B. Rechargeable Lithium-ion Batteries SPECIFICATIONS

TYPE TEST REPORT. OPzS CELLS AND BLOCK BATTERIES. According to IEC

FAT. FAT Battery Range FIAMM.COM

LEADING THE WAY DAWN OF A NEW ERA CARBON FIBRE AGM DEEP CYCLE BATTERIES SOLAR AND MARINE SERIES

JCB CONSUMER & INDUSTRIAL BATTERY RANGE

Tubular Gel Technology For Solar Applications

Phosphate-base Lithium-ion Battery Pack Model:LFP V 1350Ah Product Specifications Lithium Energy Solution 1/8

12-Batteries and Inverters. ECEGR 452 Renewable Energy Systems

6 & 12 Volt Monobloc. Haze Battery Company Ltd

Modular Max Range BATTERY SOLUTIONS. NEBS qualified. Reliable capacities. EverExceed power your applications

Batery SERIES. VALVE REGULATED LEAD ACID BATTERies INFINITE POWER. Mission Critical Applications. All Battery Range

Haze Battery Company Ltd

VRLA Battery. Battery Construction. Top lid Safety valve (under the Top lid) Terminal. Cover

Charge Voltage(V/cell) Set point (V) (V)

CELEBRATING 48 YEARS OF INNOVATION. 48 years BSI We ve Got The Power.

CELLYTE 12 PLF & 12PLT Range

Sealed Lead-Acid Batteries

Sales Brochure +44 (0) Quality in Every Language 2009/ (0)

Sealed Lead-Acid Batteries

[Charge] [Lead dioxide] [Lead] [Sulfuric acid] [Lead sulfate] [Lead sulfate] [Water]

Deep Cycle AGM Range VRLA

batteries powering your lifestyle...

SOLAR ENERGY SYSTEM. Specification

Thumper 60 AH. Thumper 75 AH

Maintenance Free Sealed Lead Acid Batteries

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

PSIM Tutorial. How to Use Lithium-Ion Battery Model

4840 Technical specification

CATALOG 2017 MOTIVE. RESERVE. AUTOMOTIVE. CHARGER. BATTERY PACKS. CONSUMER

Modular Max AGM Range VRLA

Sealed Rechargeable VRLA Batteries

General Specifications (Type D)

Pure Lead-Tin Technology

Lithium-Ion CYCLIC BATTERIES. Applications. LITHIUM-ION BATTERIES. LiFePO4 BATTERY CELLS. Only benefits. Advantages. Li-Ion

» IMPROVED EFFICIENCY» IMPROVED PRODUCTIVITY» POWER QUALITY» LOW-CARBON ENVIRONMENT.

SSLA. SSLA Battery Range FIAMM.COM

SSLA. SSLA Battery Range FIAMM.COM

POWER FOR TOMORROW. Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

Specification. For. LiFePO 4 Rechargeable Cell. EnnoPro Group Limited. Cell Type : CEBA AH

Lithium-Ion CYCLIC BATTERIES. Applications. LITHIUM-ION BATTERIES. LiFePO4 BATTERY CELLS. Only benefits. Advantages.

FULLY CERTIFIED ON-TIME DELIVERY ATEC GRP ENCLOSURES

EcoSafe EOPzV. Operation Guide for Solar Applications

TUTORIAL Lithium Ion Battery Model

Plug-in Digital Battery Regenerator From Waste Battery to Gold!!

Haze Battery Company Ltd

Full-Automatic Microprocessor Controlled Battery Charger for 12V Lead Batteries.

6 & 12 Volt Monobloc GEL Range

Try ZEUS for: Why Choose Zeus?

Custom Power Solar Radian Battery Energy Storage System

Indicative Battery Testers. Intelligent Battery Tester Chrome Tester OPERATIONS MANUAL. IBT Chrome Tester BT IBTCHR

POWER-plus. Ni-Cd XHP. Capacity: 10 Ah to 250 Ah

GV-Boost Manual. 8A Input / W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking

Testing Lead-acid fire panel batteries

Digital Mobile Charge Advanced Electronic In-Transit 4-Stage Battery to Battery Charger

Product Change Notification

Batteries for Renewable Energy Applications

Transcription:

GD5-2 2V5AH Applications Electric tools Vehicle in place of walking Lawn mowers Golf trolleys and golf cart Portable apparatus, lights and instruments; Electric toys Illumination light Fire alarms Portable power Wheelchairs Solar energy systems Marine RV Medical equipments. 91 141 OHSAS 181 Specification Nomial Voltage Nomial Capacity(1HR) Dimension Approx Weight Terminal Container Material Max. Discharge Current Internal Resistance Operating Temp.Range Nominal Operating Temp. Range Float charging Voltage Recommended Maximum Charging Current Limit Equalization and Cycle Service Capacity affected by Temperature Self Discharge 2V 5.AH @1hr-rate to 1.8V per cell @25 Length Width Container Height Total Height (with Terminal) Approx 26.7 Kg (58.86 Ibs) T11 ABS 25A (5s) Approx.62mΩ Discharge : -2 6 (-4 14 ) Charge : 5 (32 122 ) Storage : -2 6 (-4 14 ) 25 5 (77 41 ) 2.27 to 2.3 VDC/unit Average at 25 1 A 2.43 to 2.47 VDC/unit Average at 25 4 (14 ) 25 ( 77 ) ( 32 ) 24 2mm (9.45 inches) 175 2mm (6.89 inches) 33 2mm (12.99 inches) 35 2mm (13.78 inches) 13% 1% 86% JYC GD series batterys may be stored for up to 6 months at 25 (77 ) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Constant Current Discharge Characteristics: A (25 ) 1.6V 1.7V 1.8V 15MIN 3MIN 1HR 2HR 3HR 4HR 5HR 6HR 8HR 1HR 678.9 5.7 312.2 191.5 142.6 12.3 89.58 8.43 64.92 52.8 645.5 48.7 38.2 184.5 136.7 98.8 88.68 78.49 62.2 51.58 61.9 453.2 32.2 181.5 133.7 97.9 87.41 76.55 61.5 51.9 534.4 47.8 278.3 171.6 126.7 92.5 86.28 72.68 59.11 5.54 46. 371.5 262.3 163.6 121.7 91.6 84.79 71.71 58.14 5.7 389. 334.4 242.4 154.6 115.7 84.39 79.8 67.83 55.23 47.1 Constant Power Discharge Characteristics: W(25 ) 1.6V 1.7V 1.8V 15MIN 3MIN 1HR 2HR 3HR 4HR 5HR 6HR 8HR 1HR 1188 912.4 58.9 358.3 265.8 192.3 178.1 155.2 123.5 13.8 1157 97.5 577.9 353.2 26.6 189.5 176.4 153.2 122.5 12.8 193 858.9 572.2 348. 256.6 188.7 174.3 149.6 12.6 12.2 973.8 774. 536.7 329.4 247.4 179.3 171.9 142.3 116.8 11.1 842.9 76.2 51.4 314.6 237.2 178.4 168.9 14.6 114.9 1.3 718.8 636.7 473.4 297.8 226. 165.3 159.4 133.2 19.2 94.5 Note The above data are average values, and can be obtained with 3 charge/discharge cycles. These are not minimum values. Page 1 of 2

GD5-2 2V5AH Dimensions 7 [.276] T11 Terminal Unit: mm [inches] 2 [.787] M8 [.315] 175 2 Life characteristics of cyclic use Storage characteristic Capacity(%) 12 1 8 6 4 2 1% 5% 3% Capacity (%) 1 8 6 4 2 4 3 2 1 (Carry out supplementary charge before use if 1% capacity is requires) before use. This supplementary charge will help to recover the capacity and should be made as early as possible. Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this state is reached 3 6 9 12 15 18 Number of Cycle(Times) 21 2 4 6 8 1 12 14 16 18 2 22 24 Storage Time (months) Supplementary charge and storage guidelines Charge characteristic Curve for standby use Discharge characteristic Curve 2.5 Charge Volume 12.24 2.1 2.33 Charge Voltage 1.2 2. Charge Voltage( V ) 2.17 2. 1.83 1.67 1.5 1 Discharge 1%(.5CA 2h) 5%(.5CA 1h) 2 Charge Charge Voltage2.275V/C Charge Current.1CA 3 Temperature 25 Charge Current 2 4 6 8 1 12 14 16 18 Charge Time(h) 2 24 28 8 6 4 2 C harge V olum e (% ).16.12.8.4 Charge Current (CA) Term inal Voltage (V ) 1.9 1.8 1.7 1.6.6 1.2 3 6 12 3 1 2 5 min 2C 1C.6C Discharge Time.35C.16C Hr.5C.94C 1 2 24 JYC GD BATTERIES 2 This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/ specification are subject to modification without notice. Contact JYC for the latest information. Page 2 of 2

GD6-2 2V6AH Applications Electric tools Vehicle in place of walking Lawn mowers Golf trolleys and golf cart Portable apparatus, lights and instruments; Electric toys Illumination light Fire alarms Portable power Wheelchairs Solar energy systems Marine RV Medical equipments. 91 141 OHSAS 181 Specification Nomial Voltage Nomial Capacity(1HR) Dimension Approx Weight Terminal Container Material Max. Discharge Current Internal Resistance Operating Temp.Range Nominal Operating Temp. Range Float charging Voltage Recommended Maximum Charging Current Limit Equalization and Cycle Service Capacity affected by Temperature Self Discharge 2V 6.AH @1hr-rate to 1.8V per cell @25 Length Width Container Height Total Height (with Terminal) Approx 33. kg ( 72.753 lbs) T11 ABS 3A (5s) Approx.62mΩ Discharge : -2 6 (-4 14 ) Charge : 5 (32 122 ) Storage : -2 6 (-4 14 ) 25 5 (77 41 ) 2.27 to 2.3 VDC/unit Average at 25 12 A 2.43 to 2.47 VDC/unit Average at 25 4 (14 ) 25 ( 77 ) ( 32 ) 3 2mm (11.81 inches) 175 2mm ( 6.89 inches) 33 2mm (12.99 inches) 35 2mm (13.78 inches) 13% 1% 86% JYC GD series batterys may be stored for up to 6 months at 25 (77 ) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Constant Current Discharge Characteristics: A (25 ) 1.6V 1.7V 1.8V 15MIN 3MIN 1HR 2HR 3HR 4HR 5HR 6HR 8HR 1HR 814.6 6.8 374.6 229.8 171.2 122.8 17.5 96.51 77.91 62.49 774.6 576.8 369.9 221.4 164. 118.5 16.4 94.19 74.42 61.9 722.3 543.8 362.7 217.9 16.4 117.4 14.9 91.86 73.26 61.3 641.3 489.4 334. 25.9 152. 111. 13.5 87.21 7.93 6.65 552. 445.7 314.8 196.3 146. 19.9 11.7 86.5 69.77 6.8 466.8 41.3 29.9 185.5 138.9 11.3 95.76 81.4 66.28 56.41 Constant Power Discharge Characteristics: W(25 ) 1.6V 1.7V 1.8V 15MIN 3MIN 1HR 2HR 3HR 4HR 5HR 6HR 8HR 1HR 1426 195 697.1 43. 319. 23.8 213.7 186.2 148.3 124.5 1389 189 693.5 423.8 312.7 227.4 211.7 183.8 147. 123.3 1312 131 686.6 417.6 38. 226.5 29.2 179.6 144.7 122.6 1169 928.8 644. 395.3 296.9 215.1 26.3 17.7 14.2 121.4 111 847.4 612.4 377.5 284.6 214.1 22.7 168.7 137.9 12.4 862.6 764. 568.1 357.4 271.2 198.3 191.2 159.8 131.1 113.4 Note The above data are average values, and can be obtained with 3 charge/discharge cycles. These are not minimum values. Page 1 of 2

GD6-2 2V6AH Dimensions 7 [.276] T11 Terminal Unit: mm [inches] 2 [.787] M8 [.315] Life characteristics of cyclic use Storage characteristic Capacity(%) 12 1 8 6 4 2 1% 5% 3% Capacity (%) 1 8 6 4 2 4 3 2 1 (Carry out supplementary charge before use if 1% capacity is requires) before use. This supplementary charge will help to recover the capacity and should be made as early as possible. Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this state is reached 3 6 9 12 15 18 Number of Cycle(Times) 21 2 4 6 8 1 12 14 16 18 2 22 24 Storage Time (months) Supplementary charge and storage guidelines Charge characteristic Curve for standby use Discharge characteristic Curve 2.5 Charge Volume 12.24 2.1 2.33 Charge Voltage 1.2 2. Charge Voltage( V ) 2.17 2. 1.83 1.67 1.5 1 Discharge 1%(.5CA 2h) 5%(.5CA 1h) 2 Charge Charge Voltage2.275V/C Charge Current.1CA 3 Temperature 25 Charge Current 2 4 6 8 1 12 14 16 18 Charge Time(h) 2 24 28 8 6 4 2 C harge V olum e (% ).16.12.8.4 Charge Current (CA) Term inal Voltage (V ) 1.9 1.8 1.7 1.6.6 1.2 3 6 12 3 1 2 5 min 2C 1C.6C Discharge Time.35C.16C Hr.5C.94C 1 2 24 JYC GD BATTERIES 2 This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/ specification are subject to modification without notice. Contact JYC for the latest information. Page 2 of 2

GD8-2 2V8AH Applications Electric tools Vehicle in place of walking Lawn mowers Golf trolleys and golf cart Portable apparatus, lights and instruments; Electric toys Illumination light Fire alarms Portable power Wheelchairs Solar energy systems Marine RV Medical equipments. 91 141 OHSAS 181 Specification Nomial Voltage Nomial Capacity(1HR) Dimension Approx Weight Terminal Container Material Max. Discharge Current Internal Resistance Operating Temp.Range Nominal Operating Temp. Range Float charging Voltage Recommended Maximum Charging Current Limit Equalization and Cycle Service Capacity affected by Temperature Self Discharge 2V 8.AH @1hr-rate to 1.8V per cell @25 Length Width Container Height Total Height (with Terminal) Approx 45.1 kg ( 99.428 lbs) T11 ABS 32A (5s) Approx.6mΩ Discharge : -2 6 (-4 14 ) Charge : 5 (32 122 ) Storage : -2 6 (-4 14 ) 25 5 (77 41 ) 2.27 to 2.3 VDC/unit Average at 25 16 A 2.43 to 2.47 VDC/unit Average at 25 4 (14 ) 25 ( 77 ) ( 32 ) 41 3mm (16.14 inches) 175 3mm (6.89 inches) 33 3mm (12.99 inches) 351 3mm (13.82 inches) 13% 1% 86% JYC GD series batterys may be stored for up to 6 months at 25 (77 ) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Constant Current Discharge Characteristics: A (25 ) 1.6V 1.7V 1.8V 15MIN 3MIN 1HR 2HR 3HR 4HR 5HR 6HR 8HR 1HR 186 81. 499.5 36.4 228.2 163.7 143.3 128.7 13.9 83.32 133 769.1 493.2 295.3 218.7 158. 141.9 125.6 99.23 82.53 963.1 725. 483.6 29.5 213.9 156.6 139.9 122.5 97.68 81.74 855. 652.5 445.3 274.5 22.7 147.9 138.1 116.3 94.57 8.86 736. 594.3 419.7 261.7 194.7 146.5 135.7 114.7 93.2 8.11 622.4 535. 387.8 247.4 185.1 135. 127.7 18.5 88.37 75.22 Constant Power Discharge Characteristics: W(25 ) 1.6V 1.7V 1.8V 15MIN 3MIN 1HR 2HR 3HR 4HR 5HR 6HR 8HR 1HR 192 146 929.5 573.3 425.3 37.7 285. 248.3 197.7 166. 1852 1452 924.6 565.1 417. 33.1 282.3 245.1 196. 164.4 1749 1374 915.5 556.8 41.6 32. 279. 239.4 193. 163.5 1558 1238 858.7 527.1 395.9 286.8 275. 227.6 186.9 161.8 1349 113 816.6 53.4 379.5 285.5 27.2 224.9 183.9 16.5 115 119 757.5 476.5 361.5 264.4 255. 213.1 174.7 151.2 Note The above data are average values, and can be obtained with 3 charge/discharge cycles. These are not minimum values. Page 1 of 2

GD8-2 2V8AH Dimensions T11 Terminal Unit: mm [inches] 41 3 7 [.276] 2 [.787] M8 [.315] 41 3 119 3 175 3 351 3 33 3 Life characteristics of cyclic use Storage characteristic Capacity(%) 12 1 8 6 4 2 1% 5% 3% Capacity (%) 1 8 6 4 2 4 3 2 1 (Carry out supplementary charge before use if 1% capacity is requires) before use. This supplementary charge will help to recover the capacity and should be made as early as possible. Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this state is reached 3 6 9 12 15 18 Number of Cycle(Times) 21 2 4 6 8 1 12 14 16 18 2 22 24 Storage Time (months) Supplementary charge and storage guidelines Charge characteristic Curve for standby use Discharge characteristic Curve 2.5 Charge Volume 12.24 2.1 2.33 Charge Voltage 1.2 2. Charge Voltage( V ) 2.17 2. 1.83 1.67 1.5 1 Discharge 1%(.5CA 2h) 5%(.5CA 1h) 2 Charge Charge Voltage2.275V/C Charge Current.1CA 3 Temperature 25 Charge Current 2 4 6 8 1 12 14 16 18 Charge Time(h) 2 24 28 8 6 4 2 C harge V olum e (% ).16.12.8.4 Charge Current (CA) Term inal Voltage (V ) 1.9 1.8 1.7 1.6.6 1.2 3 6 12 3 1 2 5 min 2C 1C.6C Discharge Time.35C.16C Hr.5C.94C 1 2 24 JYC GD BATTERIES 2 This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/ specification are subject to modification without notice. Contact JYC for the latest information. Page 2 of 2

GD1-2 2V1AH Applications Electric tools Vehicle in place of walking Lawn mowers Golf trolleys and golf cart Portable apparatus, lights and instruments; Electric toys Illumination light Fire alarms Portable power Wheelchairs Solar energy systems Marine RV Medical equipments. 91 141 OHSAS 181 Specification Nomial Voltage Nomial Capacity(1HR) Dimension Approx Weight Terminal Container Material Max. Discharge Current Internal Resistance Operating Temp.Range Nominal Operating Temp. Range Float charging Voltage Recommended Maximum Charging Current Limit Equalization and Cycle Service Capacity affected by Temperature Self Discharge 2V 1.AH @1hr-rate to 1.8V per cell @25 Length Width Container Height Total Height (with Terminal) Approx 52. Kg (114.64 Ibs) T11 ABS 4A (5s) Approx.55mΩ Discharge : -2 6 (-4 14 ) Charge : 5 (32 122 ) Storage : -2 6 (-4 14 ) 25 5 (77 41 ) 2.27 to 2.3 VDC/unit Average at 25 2 A 2.43 to 2.47 VDC/unit Average at 25 4 (14 ) 25 ( 77 ) ( 32 ) 13% 1% 86% 475 3mm (18.7 inches) 175 3mm (6.89 inches) 328 3mm (12.91 inches) 35 3mm (13.78 inches) JYC GD series batterys may be stored for up to 6 months at 25 (77 ) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Constant Current Discharge Characteristics: A (25 ) 1.6V 1.7V 1.8V 15MIN 3MIN 1HR 2HR 3HR 4HR 5HR 6HR 8HR 1HR 1358 11 624.4 383. 285.3 24.7 179.2 16.9 129.8 14.2 1291 961.4 616.5 369.1 273.3 197.5 177.4 157. 124. 13.2 124 96.3 64.5 363.1 267.3 195.7 174.8 153.1 122.1 12.2 169 815.6 556.6 343.1 253.4 184.9 172.6 145.4 118.2 11.1 92. 742.9 524.7 327.2 243.4 183.1 169.6 143.4 116.3 1.1 778.1 668.8 484.8 39.2 231.4 168.8 159.6 135.7 11.5 94.2 Constant Power Discharge Characteristics: W(25 ) 1.6V 1.7V 1.8V 15MIN 3MIN 1HR 2HR 3HR 4HR 5HR 6HR 8HR 1HR 2377 1825 1162 716.7 531.7 384.6 356.2 31.4 247.1 27.5 2315 1815 1156 76.3 521.2 378.9 352.9 36.4 245. 25.6 2187 1718 1144 696. 513.3 377.4 348.7 299.3 241.2 24.3 1948 1548 173 658.8 494.9 358.5 343.8 284.5 233.6 22.3 1686 1412 121 629.2 474.4 356.9 337.8 281.2 229.9 2.6 1438 1273 946.8 595.6 451.9 33.6 318.7 266.4 218.4 189. Note The above data are average values, and can be obtained with 3 charge/discharge cycles. These are not minimum values. Page 1 of 2

GD1-2 2V1AH Dimensions 7 [.276] T11 Terminal Unit: mm [inches] 2 [.787] M8 [.315] 175 3 Life characteristics of cyclic use Storage characteristic Capacity(%) 12 1 8 6 4 2 1% 5% 3% Capacity (%) 1 8 6 4 2 4 3 2 1 (Carry out supplementary charge before use if 1% capacity is requires) before use. This supplementary charge will help to recover the capacity and should be made as early as possible. Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this state is reached 3 6 9 12 15 18 Number of Cycle(Times) 21 2 4 6 8 1 12 14 16 18 2 22 24 Storage Time (months) Supplementary charge and storage guidelines Charge characteristic Curve for standby use Discharge characteristic Curve 2.5 Charge Volume 12.24 2.1 2.33 Charge Voltage 1.2 2. Charge Voltage( V ) 2.17 2. 1.83 1.67 1.5 1 Discharge 1%(.5CA 2h) 5%(.5CA 1h) 2 Charge Charge Voltage2.275V/C Charge Current.1CA 3 Temperature 25 Charge Current 2 4 6 8 1 12 14 16 18 Charge Time(h) 2 24 28 8 6 4 2 C harge V olum e (% ).16.12.8.4 Charge Current (CA) Term inal Voltage (V ) 1.9 1.8 1.7 1.6.6 1.2 3 6 12 3 1 2 5 min 2C 1C.6C Discharge Time.35C.16C Hr.5C.94C 1 2 24 JYC GD BATTERIES 2 This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/ specification are subject to modification without notice. Contact JYC for the latest information. Page 2 of 2

GD15-2 2V15AH Applications Electric tools Vehicle in place of walking Lawn mowers Golf trolleys and golf cart Portable apparatus, lights and instruments; Electric toys Illumination light Fire alarms Portable power Wheelchairs Solar energy systems Marine RV Medical equipments. 91 141 OHSAS 181 Specification Nomial Voltage Nomial Capacity(1HR) Dimension Approx Weight Terminal Container Material Max. Discharge Current Internal Resistance Operating Temp.Range Nominal Operating Temp. Range Float charging Voltage Recommended Maximum Charging Current Limit Equalization and Cycle Service Capacity affected by Temperature Self Discharge 2V 15.AH @1hr-rate to 1.8V per cell @25 Length Width Container Height Total Height (with Terminal) Approx 85.5 Kg (188.495 Ibs) T11 ABS 6A (5s) Approx.5mΩ Discharge : -2 6 (-4 14 ) Charge : 5 (32 122 ) Storage : -2 6 (-4 14 ) 25 5 (77 41 ) 2.27 to 2.3 VDC/unit Average at 25 3 A 2.43 to 2.47 VDC/unit Average at 25 4 (14 ) 25 ( 77 ) ( 32 ) 13% 1% 86% 43 3mm (15.87 inches) 354 3mm (13.94 inches) 339 3mm (13.35 inches) 349 3mm (13.74 inches) JYC GD series batterys may be stored for up to 6 months at 25 (77 ) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Constant Current Discharge Characteristics: A (25 ) 1.6V 1.7V 1.8V 15MIN 3MIN 1HR 2HR 3HR 4HR 5HR 6HR 8HR 1HR 237 152 936.6 574.6 427.9 37. 268.7 241.3 194.8 156.2 1937 1442 924.7 553.6 41. 296.3 266. 235.5 186. 154.7 186 1359 96.7 544.6 41. 293.6 262.2 229.7 183.1 153.3 163 1223 834.9 514.7 38. 277.4 258.8 218. 177.3 151.6 138 1114 787. 49.8 365.1 274.7 254.4 215.1 174.4 15.2 1167 13 727.2 463.8 347.1 253.2 239.4 23.5 165.7 141. Constant Power Discharge Characteristics: W(25 ) 1.6V 1.7V 1.8V 15MIN 3MIN 1HR 2HR 3HR 4HR 5HR 6HR 8HR 1HR 3565 2737 1743 175 797.5 577. 534.3 465.5 37.6 311.3 3472 2723 1734 16 781.8 568.4 529.3 459.6 367.5 38.3 328 2577 1717 144 769.9 566.2 523. 448.9 361.8 36.5 2922 2322 161 988.3 742.3 537.8 515.7 426.8 35.4 33.4 2529 2119 1531 943.8 711.6 535.3 56.6 421.7 344.8 3.9 2156 191 142 893.5 677.9 495.8 478.1 399.5 327.6 283.5 Note The above data are average values, and can be obtained with 3 charge/discharge cycles. These are not minimum values. Page 1 of 2

GD15-2 2V15AH Dimensions 7 [.276] T11 Terminal Unit: mm [inches] 2 [.787] M8 [.315] Life characteristics of cyclic use Storage characteristic Capacity(%) 12 1 8 6 4 2 1% 5% 3% Capacity (%) 1 8 6 4 2 4 3 2 1 (Carry out supplementary charge before use if 1% capacity is requires) before use. This supplementary charge will help to recover the capacity and should be made as early as possible. Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this state is reached 3 6 9 12 15 18 Number of Cycle(Times) 21 2 4 6 8 1 12 14 16 18 2 22 24 Storage Time (months) Supplementary charge and storage guidelines Charge characteristic Curve for standby use Discharge characteristic Curve 2.5 Charge Volume 12.24 2.1 2.33 Charge Voltage 1.2 2. Charge Voltage( V ) 2.17 2. 1.83 1.67 1.5 1 Discharge 1%(.5CA 2h) 5%(.5CA 1h) 2 Charge Charge Voltage2.275V/C Charge Current.1CA 3 Temperature 25 Charge Current 2 4 6 8 1 12 14 16 18 Charge Time(h) 2 24 28 8 6 4 2 C harge V olum e (% ).16.12.8.4 Charge Current (CA) Term inal Voltage (V ) 1.9 1.8 1.7 1.6.6 1.2 3 6 12 3 1 2 5 min 2C 1C.6C Discharge Time.35C.16C Hr.5C.94C 1 2 24 JYC GD BATTERIES 2 This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/ specification are subject to modification without notice. Contact JYC for the latest information. Page 2 of 2