APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Similar documents
APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply

APC by Schneider Electric Smart-UPS OnLine with Lithium Ion Batteries Uninterruptible Power Supply 1 kva, 1.5 kva 230 V Solution

APC by Schneider Electric Smart-UPS On-Line SRT Guide Specification 5 kva 6 kva, 8 kva, 10 kva models 208 V, 240 V Solution

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

TECHNICAL DATA SHEET KVA UPS Systemss

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

POWER kva

EFFEKTA Power Supplies

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Illuminator Series CR NEMA 3R

Technical Data Sheets

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Technical Data Sheets

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

Industrial PFC UPS System

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

D Series: UPS UPTO - 300KVA - Three / Three Phase

Technical Data Sheets

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Sola/Hevi-Duty S3K Series Mini-Tower UPS

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

MKN-DSP SERIES - THREE PHASE

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

PowerValue 11/31 T kva

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

Liebert PowerSure PSI UPS

Technical Data Sheets

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

MINUTEMAN POWER TECHNOLOGIES Endeavor LCD Series Product Specifications 1000VA 3000VA Single-phase Uninterruptible Power Supply 1.

Marketing Management Team of Europe

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

3 Uninterruptible Power Systems

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.0 GENERAL

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

On-line, Single Phase, Double Conversion UPS

POWERTRONIX QUASAR 5-40 KVA

Product Specifications

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Specification SENTINEL PRO

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

3 Uninterruptible Power Systems

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS

Technical Data Sheets

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Technical data sheets

TOSHIBA /20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

Series 120/120VAC Universal Tower/Rack Mount

Uninterruptible Power Systems

GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Master DIALOG INDUSTRY RANGE

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

GUIDE SPECIFICATIONS 15-45kVA and 15-90kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Model ES VA to VA SINGLE PHASE UNINTERRUPTIBLE POWER SYSTEM

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

3 Uninterruptible Power Systems

Uninterruptible Power Systems

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

2 Uninterruptible Power Systems

YOUR POWER IN SAFE HANDS. E Series UPS

Uninterruptible Power System

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Liebert. FP 50Z kva

Supply, testing, installation and commissioning of 5 ky A UPS system as per the following specification:

Power+ CLASSIC. 20/30 kva, 3x208 Vac

U N I T Y / Three-Phase Uninterruptible Power Systems UT380 and UT Hz

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

.3 Section Waste Management and Disposal.

Sola 3000 Guide Specifications

Transcription:

APC Smart-UPS GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous duty, single-phase, solid-state, static Uninterruptible Power System (UPS) hereafter referred to as the UPS. B. The UPS utilizes double conversion online topology designed to protect electronic equipment by supplying reliable, network-grade power featuring extremely tight voltage and frequency regulation. The UPS also features internal bypass and input power factor correction. C. The primary sections of the UPS are: input disconnect and filter stage, input PFC power stage, energy storage stage (DC bus capacitor bank), output power stage (inverter), DC/DC converter and a battery charger. The control of power module and fault detection logic is microcontroller based. Input disconnect and filter stage contains input backfeed relay, input filter, transient suppression. Input PFC power stage contains non-isolated power factor correcting AC/DC converters. This converter is capable of full power operation in very wide input voltage range. The energy storage stage is a split DC bus capacitor handling seamless transitions from battery to line and vice versa as well as the low and high frequency power stages ripple. The DC/DC converter stage transfers the nominal DC battery voltage up to DC bus voltage for supplying energy to inverter stage when AC input has an outage. The inverter stage operates directly from the DC bus and produces an AC output voltage of 220/230/240VAC output. The output of UPS is either connected through a bypass relay to the inverter or to the input filtered line. UPS contains a battery charger, which operates from the AC input section directly. D. The UPS batteries are internal, not hot-swappable, not user-replaceable. E. The UPS and associated equipment shall operate in conjunction with a primary power supply and an output distribution system to provide quality uninterrupted power for mission critical, electronic equipment load. F. All programming and miscellaneous components for a fully operational system as described in this specification shall be available as part of the UPS.

H. Configuration Specifics: The UPS is available in one of the following configurations: MODEL SKU # TOWER - MOUNT 1000VA APC Smart-UPS 1000VA 230V SRC1KI APC Smart-UPS 1000VA 230V Argentina SRC1KI-AR TOWER MOUNT 2000VA APC Smart-UPS 2000VA 230V APC Smart-UPS 2000VA 230V Argentina SEC2KI SRC2KI-AR 1.2 STANDARDS A. Designed to EN62040-2 B. Designed to IEC 61000-2-2, 2-3, 4-2, 4-3, 4-4, 4-6, 4-8, 4-11, EN 61000-4-5: 2005 C. Designed to IEC 60068-2-27, 2-32, 2-64 D. Designed to IEC62040-3 E. Designed to IEC 60950 F. ISO 9001 G. ISO 14001 1.3 MODES OF OPERATION A. Online: The input PFC power stage and the output power stage (inverter) shall operate in an online manner to continuously regulate power to the critical load. The input PFC stage provides regulated power to the load for all line and load conditions within the range of the UPS specifications. The inner battery charger shall be capable of full battery recharge. B. On Battery: Upon failure of the AC input source, the critical load shall continue being supplied by the output power stage (inverter), which shall derive its power from the battery system. There shall be no interruption in power to the critical load during both transfers to battery operation and retransfers from battery to online operation. C. Bypass: The bypass mode shall be used to provide transfer of critical load from the inverter output to the primary power source. This transfer, along with its retransfer, shall take place with minimum power interruption, 4 ms, to the critical load. In the event of an emergency, this transfer shall be an automatic function.

D. Green mode/high efficiency mode: Enabling this mode shall transfer the load to utility input power through bypass relay as long as input voltage is within the range of ±24V of configured output voltage and input frequency is within the range of ±3 Hz of output frequency. If the utility power goes out of range, inverter is turned on and load is transferred back to inverter (online or on battery). Power to the connected load may be interrupted up to 4 ms during transfer and retransfer. Power to the connected load may be interrupted up to 10 ms during retransfer to battery mode. E. Maintenance or service of the UPS: Please turn off and remove UPS from the AC input connection or wiring. 1.4 SUBMITTALS A. Proposal Submittals: 1. As bid system bill of materials. 2. Product catalog sheets or equipment brochures. 3. Product guide specifications. 4. System single-line operation diagram. 5. Installation information, including weights and dimensions. 6. Information about terminal locations for power and control connections. B. Delivery Submittals: 1. User manual, which includes installation and operating instructions. PART 2 - PRODUCT 2.1 MECHANICAL DESIGN A. The UPS is contained in a rugged steel cabinet with plastic front bezel; B. The UPS dimensions are; Dimensions SRC1KI / SRC1KI-AR without packaging (W x H x D) 145 mm (5.7in) x 220 mm (8.66 in) x 400 mm (15.75 in) SRC2KI / SRC2KI-AR 145 mm (5.7in) x 220 mm (8.66 in) x 504 mm (19.8 in) C. The UPS cabinet shall be Tower- Mount;

2.2 SYSTEM CHARACTERISTICS A. System Capacity: 1. The system is rated to be capable of supporting: a. 1000VA or 800W whichever limit is reached first (for the 1000VA model). b. 2000VA or 1600W whichever limit is reached first (for the 2000VA model). B. The UPS efficiency shall be 88% Max., without degradation of output regulation as specified. C. Input: 1. AC input nominal voltage: 220/230/240VAC, single phase, 3 wire (L + N + G), connected via IEC-320 C14 connector. 2. AC input voltage window: a. 190 295VAC (±5%) (L-N) at full load, while providing nominal charging power to the battery system, Ambient @ 40 C b. 175-295VAC (±5%) (L-N) at full load, Charger derated linearly < 190V, Ambient < 35 C c. 140 295VAC (±5%) (L-N) at 60% load, Charger derated linearly < 190V, Ambient @ 40 C d. 125 295VAC (±5%) (L-N) at 60% load, Charger derated linearly < 190V, Ambient < 35 C 3. Input frequency range: 40-70Hz; 4. Input Power Factor: 0.93 typical. 5. Input Current Distortion: Meets the requirements of IEC61000-3-2 /3-3 6. Crest factor: 3:1. D. UPS Output: 1. AC Output Nominal Output: 230VAC Single Phase, 3 wire (Phase + N + G); 2. Output connectors: 3 x IEC 320 C13 connectors (SRC1KI Model), 4 x IEC 320 C13 connectors (SRC2KI Model), 3 x ARGENTINA SOCKETS (SRC1KI-AR/SRC2KI- AR); 3. Output frequency: 50/60Hz +/- 3Hz tracking (Auto detection); 4. AC output voltage distortion: < 3% @ 100% linear load; < 6% @ 100% non-linear Load, < 15% during last 60 seconds of back up time with full load only. 5. AC output static voltage regulation: +/-1%;

6. AC output dynamic voltage regulation: +/- 6% during 20% to 100% R load take on and 100% to 20% R load take off in On-line mode. +/- 9% during 20% to 100% R load take on and 100% to 20% R load take off in On-battery mode. Recovery time < 200 ms; 7. Overload Rating: a. Online (Ambient < 35 C): <105% - infinite; 125% - 1 minute; 150% - 30 seconds; 150% to < 210% 3 seconds; > 210% Transfer to bypass immediately; b. Online (Ambient > 35 C): <105% - infinite; 125% - 30 seconds; 150% - 15 seconds; 150% to < 210% 1.5 seconds; > 210% Transfer to bypass immediately; c. Onbattery (Ambient < 35 C): <105% - infinite; 130% - 1 minute; 130% to <210% 3 seconds, > 210% shuts down immediately; d. Onbattery (Ambient > 35 C): <105% - infinite; 130% - 30 seconds; 130% to < 210% 1.5 seconds, > 210% shuts down immediately; e. Bypass/ECO Mode: 110% -120% - 30 minute: 120% - 130% - 10 minute: 130% - 150%- 1 minute f. Overload is protected by the input circuit breaker. (7 A Thermal circuit breaker is fitted at the input of the 1000VA models, a 13A Thermal circuit breaker is fitted at the input of the 2000VA models.); 8. Output Power Factor Rating: 0.8 lagging to 0.8 leading. 2.3 ENVIRONMENTAL 1. Short term storage, Ambient Temperature: -20 C to 50 C 2. Operating Ambient Temperature: 0 C to 50 C. 80% output derating when 40 C < Ambient < 50 C 3. Relative Humidity: 0 to 95% non-condensing 4. Storage altitude: 50,000 feet (15000m) above sea level 5. Operating altitude: < 10,000 feet (3000m) above sea level. 6. Audible noise: 50dBA max. (Battery fully charged, without buzzer) 2.4 INPUT PFC POWER STAGE A. The input PFC power stage of the UPS constantly rectifies the power imported from the mains input of the system, converting input mains AC power to DC power for precise regulation of

the DC bus voltage and output power stage (inverter) regulated output power. B. Input Current Total Harmonic Distortion: The input current THD I shall meet IEC61000-3-2 requirements at full system, while providing conditioned power to the critical load bus, and charging the batteries under steady-state operating conditions. This shall be accomplished with no additional filters, magnetic devices, or other components. C. Input Current Limit: 1. Input current draw from utility is limited by input converter internal fuse in online mode, 8A fuse for 1 KVA and 15A fuse 2 KVA. In bypass mode UPS operation is limited to 30 minutes for 110%-120% rated output current, 10 minutes for 120%-130% rated output current and 1 minutes for 130%-150% rated output current. 2. In cases where the source voltage to the UPS is nominal and the applied UPS load is equal to or less than 100% of UPS capacity, input current shall not exceed 130% of UPS output current, while providing full battery recharge power and importing necessary power for system losses. 2.5 OUTPUT POWER STAGE (INVERTER) A. The UPS output power stage (inverter) constantly recreates the UPS output voltage waveform by converting the DC bus voltage to AC voltage through a set of IGBT switches. In both online operation and battery operation, the output power stage (inverter) creates an output voltage waveform independent of the mains input voltage waveform. Input voltage anomalies such as brown-outs, spikes, surges, sags, and outages do not affect the amplitude or sinusoidal nature of the recreated output voltage sine wave of the output power stage (inverter). B. Overload Capability: The output power stage (inverter) is capable of withstanding >150% overload for 1.5 seconds or 150% overload for 15 seconds or 125% overload for 30 seconds or < 105% overload for indefinite length of time in online operation at 40 C ambient; The output power stage (inverter) is capable of withstanding > 130% overload for 1.5 seconds or 130% over load for 30 seconds or < 105% overload for indefinite length of time in battery operation at 40 C ambient; C. Output Contactor: The output power stage (inverter) is equipped with an output relay to provide physical isolation of the inverter from the critical bus. With this feature a failed inverter shall be removed from the critical bus. D. Battery Protection: The inverter is provided with monitoring and control circuits to limit the level of discharge on the battery system. 2.6 AUTOMATIC BYPASS A. As part of the UPS, a system automatic bypass switch is provided. The system automatic bypass shall provide a transfer of the critical load from the Inverter output to the automatic bypass input source during times when the inverter cannot support the load. Such times may be due to

prolonged or severe overloads, or UPS failure. The UPS constantly monitors the output current, as well as the bypass source voltage, and inhibits potentially unsuccessful transfers to automatic bypass from taking place. B. The design of the automatic bypass switch power path consists of a heavy-duty electromechanical relay. C. Automatic Transfers: An automatic transfer of load to bypass takes place whenever the load on the critical bus exceeds the overload rating of the UPS. Automatic transfers of the critical load from bypass back to normal operation takes place when the overload condition is removed from the critical bus output of the system. Automatic transfers of load to bypass also take place if for any reason the UPS cannot support the critical bus D. Manual Transfers: Manually initiated transfers to and from bypass may be initiated through the UPS front panel LCD display or UPS computer interface. 2.7 BATTERY A. The UPS battery system is internal to the UPS. Battery system is not user replaceable, and not hot swappable. B. The battery used are of the Valve Regulated Lead Acid (VRLA) type. C. The UPS incorporates the Intelligent Battery Management system to continuously monitor the health of battery. This system shall notify the user in the event that a failed or weak battery is found. D. Charging: 1. The intelligent battery management system contains a temperature monitoring circuit and compensation algorithm that regulates the battery charging current & voltage so as to optimize battery life. 2. The battery charging circuit remains active when in bypass and online states. E. Additional battery modules cannot be added to increase runtime. F. The UPS is shipped with battery pre-installed but disconnected. Battery connect feature is provided on the back panel. 2.8 DISPLAY AND CONTROLS A. Control Logic: The UPS is controlled by an embedded microcontroller which performs functions: 1. Monitoring quality of output voltage; 2. Monitoring vital parameters of the UPS;

3. Executing the state machine; 4. Intelligent battery management; 5. Remaining runtime calculation; 6. Self-diagnostics, self-test and proactive fault detection; 7. Communication to the host server via serial port; 8. Communication to the Network Interface Card or another SmartSlot accessory card if equipped. B. Display/Control Unit: A display/control comprised of LCD, LED and 5 pushbutton switches is located on the front side of the UPS. C. The pushbutton switches located at the Display/Control Unit: The following controls functions can be accomplished by use of the pushbutton switches located at the Display/Control Unit: 1. Turn the UPS on; 2. Turn the UPS off; 3. Initiate self-test in order to test battery condition; 4. Silence audible alarm; 5. Cold start. 6. Enable /disable bypass mode and ECO mode 7. Configure output voltage and bypass input voltage range 8. Display Input voltage & frequency, output voltage & frequency, Battery Voltage, battery capacity remaining, Ambient temperature, Load % and fault log. D. EPO switch: The UPS is equipped with Emergency Power Off (EPO) terminal which can be wired so as to provide means to instantaneously de-energize the UPS and its load from a remote location in case of emergency. E. Data displayed on the Display/Control Unit: The following indicators are available on the Display/Control Unit: 1. The UPS load bar; 2. The UPS is online; 3. The UPS is on battery;

4. The UPS battery capacity bar; 5. The UPS is in bypass; 6. The UPS is in ECO mode; 7. The UPS is overloaded; 8. The UPS is in fault state; 9. The battery is bad or disconnected; 10. UPS Output Voltage; F. Audible Alarms: Using audio signal, the UPS will notify the user about important events. The following is the list of distinct audio alarms: 1. The UPS is on battery; 2. The UPS is on battery and the remaining battery capacity is low; 3. The UPS has shut down due to low battery capacity; 4. The battery is disconnected; The battery is bad; 5. The UPS is overloaded; 6. The UPS is in fault state; PART 3 - PART 3 ACCESSORIES 3.1 SOFTWARE AND CONNECTIVITY A. Network Adaptor: APC SmartSlot Network Management Card shall allow one or more network management systems (NMS) to monitor and manage the UPS in TCP/IP network environments. B. Unattended Shutdown 1. The UPS, in conjunction with a network interface card, shall be capable of gracefully shutting down one or more operating systems during when the UPS is on battery mode. 2. The UPS is also capable of using an RS232/USB port to communicate to the host computer by means of serial communications so as to gracefully shut down one or more operating systems during an on battery situation. The PowerChute Business Edition (PCBE) software can be downloaded from website. 3.2 REMOTE UPS MONITORING, CONFIGURATION AND CONTROL

A. The following method of remote UPS control, configuration and monitoring is available: 1. Web Monitoring: Remote monitoring, configuration and control is available via a web browser such as Internet Explorer provided the UPS is equipped with 3.3 SOFTWARE COMPATIBILITY A. UPS is compatible with PowerChute Business Edition (PCBE) software. The software supports graceful shutdown and remote monitoring for various systems. B. Please visit APC web site for current listing of compatible systems. PART 4 - Part 4 - EXECUTION 4.1 FACTORY ASSISTED START-UP If a factory assisted UPS start-up is requested, factory trained service personnel shall perform the following inspections, test procedures, and on-site training: A. Visual Inspection: 1. Inspect equipment for signs of damage. 2. Verify installation per manufacturer s instructions. B. Mechanical Inspection 1. Check all UPS and external service bypass panel internal power wiring connections. 2. Check all UPS and external service bypass panel terminal screws, nuts, and/or spade lugs for tightness. C. Electrical Inspection: 1. Verify correct input and bypass voltage. 2. Verify correct UPS control wiring and terminations. 3. Verify neutral and ground conductors are properly landed. 4. Inspect external service bypass panel for proper terminations. D. Site Testing:

1. Ensure proper system start-up. 2. Verify proper firmware control functions. 3. Verify proper firmware bypass operation. 4. Verify proper bypass switch operation (where applicable). 5. Verify proper inverter operation and regulation circuits. 6. Simulate utility power failure. 7. Verify proper charger operation. 8. Document, sign, and date all test results. E. On-Site Operational Training: During the factory assisted start-up, operational training for site personnel shall include front display panel features and operation, LED indicators, start-up and shutdown procedures, maintenance bypass and AC disconnect operation, and alarm information. 4.2 MANUFACTURER FIELD SERVICE A. Worldwide service: The UPS manufacturer has a worldwide service organization available, consisting of factory trained field service personnel to perform start-up, preventative maintenance, and service of the UPS system and power equipment. The service organization offers 24 hours a day, 7 days a week, 365 days a year service support. B. Replacement parts: Parts are available through the worldwide service organization 24 hours a day, 7 days a week, 365 days a year. The worldwide service organization is capable of shipping parts within 4 working hours or on the next available flight, so that the parts may be shipped to the customer site within 24 hours. 4.3 MAINTENANCE CONTRACTS A. A complete offering of preventative and full service maintenance contracts for the UPS system and the battery system are available from APC. All contract work is performed by APC factory trained service personnel. End of Section 16611