w w w.apc.com Home Appliance & Lighting UPS HI800SQ Installation Guide and User s Manual

Similar documents
Power Inverter. Model BI800T and BI800F. w w w.apc.com. Installation Guide and User s Manual

BSNL POWER PLANT MANAGEMENT SYSTEM USING VOICE ALONG WITH TELEPHONE LINE

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Installation and Operation Back-UPS BX550CI-CN

Installation and Operation Manual Back-UPS BR800/1100CI-IN

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Installation and Operation Manual Back-UPS BX1100CI-CN

Installation and Operation Manual Back-UPS BR1000-CH

3000VA 120/208/230VAC

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

General Precautions. Personnel Precautions

Back-UPS CS Back-UPS CS 350

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

OutdoorXUPS-600AHV-8364

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Uninterruptible Power System

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

BRAVO Inverter/Battery Charger. Table of Contents

User s Manual. English. APC Smart-UPS RT. 3000/5000 VA VAC 3U Tower/Rack Mount Uninterruptible Power Supply

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

BroadBand PowerShield. 20 AHr Battery. User Manual

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

Uninterruptible Power Supply

APC Smart-UPS RT UXI/UXICH

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

HPP1 MK5 Owner s Manual

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

MM-AVR UPS Series User s Manual

Phoenix Inverter

Item no Smart AC 200 USB. User s Manual

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

USER MANUAL MPS 1-5KW SERIES

User Manual. English. APC Smart-UPS. 7500/10000 VA VAC 6U Tower/Rack Mount Uninterruptible Power Supply B 02/2004

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Installation and Operation Smart-UPS SUA500PDR

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

HPP1 MK5 Owner s Manual

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000 VA. 100/120/230 Vac. Rack Mount 1U

c-go 24V/6A 24V/8A 24V/12A

Uninterruptible Power System

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) V1.00 OWNERS MANUAL

User Manual 1.5KVA-3KVA INVERTER / CHARGER

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

LED Downlight Ceiling Fixtures

User Manual 1KVA-5KVA INVERTER / CHARGER

user s manual Model number

Home Solar 400 (HS 400) Home Solar 800 (HS 800) Home Backup 400 (HB 400) Home Backup 800 (HB 800) Owner s Manual

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

User s Manual. Automatic Switch-Mode Battery Charger

PROwatt 150 DC to AC Power Inverter. Owner s Guide

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Operation and Maintenance

WARNINGS, CAUTIONS AND NOTES

User Manual. Smart-UPS. Uninterruptible Power Supply. 1000/1500 VA 100/120/230 Vac. 750XL/1000XL VA 120/230 Vac. Tower

Solar Hybrid Inverter SP Brilliant Series

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

DC TO AC POWER INVERTER

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

Limousin II User Manual

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

User Manual 3KVA-5KVA INVERTER / CHARGER. Version: 1.1

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

1200+ WITH TIMER V1.00 OWNERS MANUAL

Pure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A

Sola 3000 Guide Specifications

O W N E R ' S M A N U A L

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

HPP1 MK6-15A/20A R00 Owners Manual

Operators Manual. Recirculating Chiller /06/08

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Uninterruptible Power System

02/15/01. Powerware User s Guide VA.

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

SUA1000I-IN / SUA1500I-IN 230 VAC

CP900EPFCLCD User s Manual K

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

Transcription:

w w w.apc.com Home Appliance & ighting UPS HI800SQ Installation Guide and User s Manual 990-2391D Copyright 2009 American Power Conversion. All rights reserved. APC is a registered trademark of American Power Conversion. All other trademarks are the property of their respective owners.

COTETS Page Overview 1 Checklist 1 Section 1. Unpacking/Inspection of Home UPS (at reseller location) 1 Section 2. Unpacking/Inspection of Home UPS (at customer location) 1 Section 3. Installation 2 Home UPS Placement 2 Battery Connection 2 Install Home UPS 2 Section 4. Controls and Indicators 3 Home UPS Controls 3 AWAY/HOME 3 TEST/MUTE 3 Circuit Breaker Switch 3 Home UPS Indicators 3 Cold Boot 3 Section 5. Troubleshooting 5 Manual Bypass 5 Section 6. Upper Cut-off Voltage Setting 5 Preventive Maintenance 6 Specifications 7 Warranty 7 Contact Information 7 FIGURES Figure 1. APC Home UPS 1 Figure 2. Typical Home Wiring After Home UPS Installation 2 Figure 3. Home UPS Connections 3 Figure 4. Home UPS Front Panel Controls and Indicators 4 Figure 5. Home UPS Bypass Connection 6 TABES Table 1. Home UPS Indicators 4 Table 2. oad Indications 4 Table 3. Home UPS Troubleshooting 5 Table 4. Upper Cut-off Voltage Setting 6 Table 5. APC Home Appliance & ighting UPS Technical Specifications 7 i

Thank you for purchasing APC s Home Appliance & ighting UPS. Please fill out the enclosed Warranty Registration Card, or register your purchase on-line at: www.apc.com/support or call BS Toll Free : 1800 4254 272 / 1800 4254 877 or Reliance : Your City Code + 39022272 Overview APC s Home UPS (Figure 1) is designed for years of trouble-free use. The Home UPS is a squarewave back-up power supply intended to serve house loads. It is rated for 800 VA/500W at 230 Vac, 50-Hz, and operates on a wide range of input voltages (100-270V). If the input voltage goes out of range (less than 100V or more than 270V), the utility is isolated and the UPS supplies power to the load from an externally connected battery (may be purchased from APC, or from the supplier of your choice). The UPS can serve inductive loads (fluorescent lamps, ceiling and table fans), resistive loads (incandescent lamps), and Switch mode power supply (SMPS) loads (television). Checklist: Figure 1. APC Home UPS Depending on what the customer has ordered, ensure the following items have been delivered: Home UPS Wiring Kit Section 1. Unpacking/Inspection of Home UPS (at reseller location)! Inspect the shipping containers for signs of obvious damage. If damage to either shipping container is extensive, notify the carrier and return the unit to the factory. If there are no apparent signs of damage, carefully open the container, and remove the packing materials (do not discard). Inspect for dents, scratches, warpage of the top cover, or other signs of damage. If unit is damaged, please notify the factory and obtain a Return Material Authorization number and return the unit as/if instructed. If there are no obvious signs of damage, repackage the unit for shipment to the customer using the materials already removed from the shipping container. Ship or otherwise deliver the unit to the customer location. Section 2. Unpacking/Inspection of Home UPS (at customer location) ote: The Home UPS Assembly is shipped with two (one male and one female) IEC connectors and battery assembly wiring for use in installing home wiring to/from the Home UPS. Inspect the shipping containers for signs of obvious damage. If damage to either shipping container is extensive, notify the carrier and return the unit to the factory. If there are no apparent signs of damage to the shipping container, carefully open the container, and remove the packing materials (do not discard).! Warning: The Home UPS weighs 7 kg. Please handle carefully. Warning: The Home UPS weighs 7 kg. Please handle carefully. Remove the item from the shipping container and inspect for: dents, scratches, warpage of the top cover, or other signs of damage. If unit is damaged, please notify the factory and obtain a Return Material Authorization number and return the unit as/if instructed. Page 1

Section 3. Installation Home UPS Placement ote: Once the unit has been completely installed, it is not desirable to move it. Ensure the area where the unit is to be placed is not in direct sunlight (surfaces may become hot). Further ensure the unit is placed in a dry area away from sources of liquids, and that the vents on each side have at least 15 cm (6 inches) of unobstructed clearance. Placement 15 cm (6 in) Battery Connection Connect the red battery terminal lead (protrudes from the lid) to the positive (+) terminal of the battery and connect the black battery terminal lead (protrudes from the lid) to the negative (-) terminal. Install Home UPS Caution: Installation of the Home UPS must be performed by a licensed and qualified electrician. Failure to comply may result in equipment damage, and may also void the Warranty. Figure 2 shows a typical home wiring scenario after installation of the Home UPS Assembly wiring. ote: The Home UPS can serve inductive loads (fluorescent lamps, ceiling and table fans), resistive loads (incandescent lamps), and SMPS loads (television). Caution: Connecting the Home UPS to a branch circuit that exceeds 16 amps may result in equipment damage. ote: Home wiring to power the desired loads should be routed and connected to a single branch circuit providing a maximum of 16 amps to the circuit, Wiring must be in accordance with local electric codes and standards. Connected loads must not exceed 500 watts when the Home UPS is On Battery. E E Electricity Board Meter oad Double-Pole Switch ighting Circuit Input Output Wiring for Home UPS Figure 2. Typical Home Wiring After Home UPS Installation Connect one end of the electrical cable from the double-pole switch lighting circuit in accordance with local electric codes and standards. Connect the other end of the electrical cable to the provided IEC connector, and then to the rear panel Input connector on the Home UPS Assembly (Figures 2 and 3). Connect one end of the electrical cable from the load in accordance with local electric codes and standards. Connect the other end of the electrical cable to the provided IEC connector, and then to the rear panel Output connector on the Home UPS Assembly (Figures 2 and 3). Connect the battery wiring harness from the battery to the rear panel input connector of the Home UPS (Figure 3) marked 12V Battery. Once the home wiring is complete and the battery is connected to the Home UPS Assembly, turn on power at the Electricity Board Meter and then at the Double-Pole Switch ighting Circuit. The Home UPS will automatically turn on. Ensure AWAY/HOME switch (Figure 4) in HOME position. Page 2

12V Battery +Ve -Ve Push to Reset IPUT OUTPUT Input : 230V, 5A, 50Hz Output : 230V, 5A, 50HZ Battery Wiring Output Harness (Red and Black Wires) These connectors are provided with the Home UPS Assembly and must be installed on to the wiring. From Electricity Board Meter (through Double-Pole Switch ighting Circuit) To oad Figure 3. Home UPS Connections Section 4. Controls and Indicators Please review this section thoroughly before applying power to the Home UPS. Home UPS Controls - Controls provided on the Home UPS consist of the holiday mode switch marked AWAY/HOME, and the Test/Mute switch, as well as a rear panel Push to Reset circuit breaker, and are defined in the following: AWAY/HOME - (also known as the holiday mode switch) - In the HOME position, this two-position rocker switch (Figure 4) sets the Home UPS so that it will switch to battery output when there is a utility power outage. In the AWAY position, the Home UPS goes into standby mode and will not switch to battery power in the event of a power outage. This is to conserve the batteries. However, in this position, the Home UPS will charge the batteries until a utility power failure occurs. TEST/MUTE - In TEST mode, when O MAIS ED is lit, on pressing this push button, the unit will do self test to determine the state of the system. During On Battery self test it will also show the load status which can be used to find out the load capacity. In the MUTE position (push in for 5 seconds), this push button switch silences the low battery buzzer. Circuit Breaker Switch (Rear Panel) - When in O MAIS mode, if the system draws more than 10A, circuit breaker will trip. To reset the circuit breaker switch, push the switch fully inward. Cold Boot - To turn on the Home UPS on Battery Mode. Keep AWAY/HOME switch in HOME position and press the TEST/ MUTE button and hold it for 2-3 seconds. Home UPS Indicators - The Home UPS provides light emitting diode (ED) indicators (Figure 4) to show the operational condition of the Home UPS and batteries. Indicators consist of Inverter oad Status (25%, 50%, 75%, 100%, and OVER OAD). Other indicators consist of: IVERTER DISABE, O MAIS, O BATTERY, and FAUT). Using Table 1, determine the condition of the Home UPS and battery. Page 3

25% 50% 75% 100% OVER OAD AWAY TEST IVERTER DISABE O MAIS O BATTERY FAUT IVERTER OAD HOME MUTE Figure 4. Home UPS Front Panel Controls and Indicators Table 1. Home UPS Indicators MODE IV DISABE (red) O MAIS (green) O BATTERY (yellow) FAUT (red) BUZZER DESCRIPTIO O IE Off On Off Off Off The unit is O-IE. O IE SEF TEST Off Flashing Off Off Off The unit is in O-IE Self-Test mode. O BATTERY SEF TEST Off Flashing On Off Off The unit is in O-BATTERY Self-Test mode and the load is less than 100%. O BATTERY Off Off On Off Off* The unit is in O-BATTERY mode and the load is less than 100%. BAD BATTERY WARIG Short Circuit (heavy overload) O BATTERY ow Battery Warning Off On Flashing Flashing Chirp every 2 seconds The unit is in O-IE mode; battery is bad. Off Off Off On Continuously On The unit is in FAUT state, due to short circuit fault. Off Off On Off Constant Beeping, Can be muted through front panel TEST/MUTE push button. * During transfer of Inverter from Mains to Battery mode, a short beeping is given to indicate Mains Out of Range. Table 2. oad Indications 25% 50% 75% 100% Overload Buzzer Description Power Meter on off off off off off The unit is in O-BATTERY mode, and the load is less than 25%. Power Meter on on off off off off The unit is in O-BATTERY mode, and the load is between 25% and 50%. Power Meter on on on off off off The unit is in O-BATTERY mode, and the load is between 50% and 75%. Power Meter on on on on off off The unit is in O BATTERY mode; the load is between 75% and the overload limit. Power Meter on on on on on on The unit is in O BATTERY mode; the load is above 100% and requires some of the loads to be off/ disconnected. OTE: In the case of a sustained overload, the Home UPS will be turned off automatically after one minute, and will wait in the fault state for a minute. After that, it will restart again. If the overload still persists, the Home UPS will be turned off again after one minute, and will wait in fault state for one minute and restart again. In the same way, it will try for three restarts. If the overload still persists, it will stay in fault state permanently until the unit is restarted with TEST / MUTE button. If the time interval between two consecutive overloads is more than 5 minutes, then the latest overload is considered as a fresh overload and three restart cycles will begin again. Page 4

Section 5. Troubleshooting ote: If the Home UPS causes interference with a television while O-BATTERY, move the television at least 3 feet away from the Home UPS. Use the information provided in Tables 1, 2 and 3 to diagnose Home UPS problems. If the problem cannot be resolved using the information provided in this manual, contact APC Technical Support. Table 3. Home UPS Troubleshooting Problem Cause Corrective Action Home UPS fails to operate when mains power is turned on, or during a utility power failure. Home UPS faults. Disconnected battery. Power is off at the Mains. Home UPS AWAY/HOME switch in the AWAY position. Dead batteries. Home UPS rear panel Push to Reset circuit breaker has tripped. Improper wiring installation or loose connection. Home UPS drops the load. Home UPS is overloaded. Ensure batteries are connected as defined in this manual. Turn on power at the Mains. Set AWAY/HOME switch to the HOME position. Home UPS failed to charge batteries, or batteries were allowed to completely discharge. Replace batteries. If replacing the batteries does not fix the problem, contact APC Technical Support. Reset the circuit breaker located on rear side of the Home UPS by pushing it fully inward until it stops; release the circuit breaker. Ensure wiring is as described earlier in this manual, and that all connections are secure. Home UPS may have an internal failure. If this happens, the unit can be disconnected from the mains by completion of a Manual Bypass (see Manual Bypass) (Figure 5). Turn off some loads connected to the Home UPS until the OVER OAD ED is no longer lit Manual Bypass - In the event of Home UPS failure or dead battery condition, the Home UPS can be disconnected from the mains and power restored to the circuit by completing a Manual Bypass (Figure 5) of the Home UPS, as follows: Remove the Wiring Management Kit from the Home UPS. Disconnect all wires connected at the Home UPS rear panel. Connect the wire from the Input socket to the wire from the Output socket. Section 6. Upper Cut-off Voltage Setting The upper transfer voltage can be set at either 290V or 270V. To adjust the upper transfer voltage procedure is as follows: 1. Keep AWAY / HOME switch in AWAY Position.Inverter Disable (Red ED) indicator will be O. 2. Unplug the inverter from the utility (Mains) power supply. Press the front panel push button TEST/MUTE. The inverter will be in Standby Mode. Page 5

Push to Reset IPUT OUTPUT Input : 230V, 5A, 50Hz Output : 230V, 5A, 50HZ Disconnect from Home UPS Connect Both Wires Completed Bypass Connection Figure 5. Home UPS Bypass Connection 3. Press the front panel push button TEST/MUTE fully inward for 10 seconds. The unit will beep and O MAIS (Green ED) O BATTERY (Amber ED) and FAUT (Red ED) indicators will flash to acknowledge ighting UPS getting into programming Mode. 4. The ighting UPS will then indicate its default Voltage setting as shown in the following Table 4. Table 4. Upper Cut-off Voltage Setting Indicators Flashing On Battery (Amber ED) and Fault (Red ED) On Mains (Green ED) and Fault (Red ED) Voltage Setting High 290 ow 270 Application ot compatible with TV s,pc and other sensitive appliances Compatible with all equipments. Recommended 5. To select the ow Voltage setting, press the TEST/MUTE button until the O MAIS (Green ED) and FAUT(Red ED) indicators are flashing. 6. To select the High Voltage setting, press the TEST/MUTE button until the O BATTERY (Amber ED) and FAUT(Red ED) indicators are flashing. 7. Once in Programming Mode, if the TEST/MUTE button is not pressed within 5 seconds, the inverter will exit programming Mode and all ED indicators will turn off. Preventive Maintenance - APC recommends the customer to do Preventive maintenance by inspecting the batteries for cracks and/or leakage, and checking Battery fluid levels and filling the batteries with distilled water (every 90 days). Dust the unit with a dry cloth. Do not use liquids when cleaning. Page 6

Specifications Warranty Table 5. APC Home Appliance & ighting UPS Technical Specifications Item Specification Input ominal Voltage 230 V Characteristics Rated Voltage 230 V Frequency 47-53 Hz ominal Rated Current 3.47 A Input Circuit Breaker Rating 10 A Input Voltage Window for Utility Operation 100-270/290 VAC ( User Settable ) Output Voltage (on Mains) 100-270/290 VAC ( User Settable ) Characteristics Voltage (on battery) 180-250 VAC Rated VA 800 VA Rated Watts 500 W Overload Indicated O BATTERY >100% Shutdown due to OVEROAD > 100% after 60 seconds (see Table 1 and following note) Frequency (O BATTERY) 50 Hz +/- 1% Surge Built-in Surge Protection Protects the load from surges and spikes Protection Environmental Ambient Operating Temperature 0-45 degrees C Humidity 95% Relative humidity, non-condensing Altitude 3000 m Physical Input ine IEC socket Outlet Receptacles IEC socket Dimensions - Unit (h) x (w) x (d) UPS: 13.0 x 50.6 x 29.3 cm Weight UPS : 7 kg Shipping Weight UPS : 8 kg APC warrants its products to be free from defects in materials and workmanship under normal use and service for 2 years for the Home UPS, and 18 months for the APC Batteries to the original purchaser. Its obligation under this warranty is limited to repairing or replacing, at its sole option, any such defective products. To obtain service under warranty you must obtain a Return Material Authorization (RMA) number from APC Technical Support or an APC Service Center. The defective unit must be returned with an RMA number, with transportation charges prepaid and it must be accompanied by a brief description of the problem and proof of date and place of purchase. This warranty applies only to the original purchaser. It will be APC s standard practice to issue factory reconditioned replacement units in exchange for original units. The warranty on reconditioned units delivered for In-warranty service is 90 days or the remainder of original warranty period, whichever is longer. Repaired units carry the balance of their original warranty period. Contact Information APC Corporate Office (India) 27 avelle Road, Bangalore 560 001 Phone: 080-3987 2000 www.apc.com/in APC Corporate Office (USA) 132 Fairgrounds Rd. West Kingstown, RI 02892, USA Phone: 401-789-0204 www.apc.com/in Toll Free Helplines...MT: 1800 4254 877, 1800 4254 272, All other operators: 39022272 (add STD code of the city you're calling from when using your mobile) Customer Service Email...indiainfo@apcc.com Technical Support Email...isbtech@apcc.com Page 7