Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

Similar documents
Ion Technologies WC33 Submersible Sump Pump

StormPro BA Series Sump Pump

StormPro BCV400 Sewage Ejector Pump

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

MetroPrime 22MPC Self-Priming Centrifugal Pump

Ion Technologies ES45 Effluent Pump

Ion Technologies SEF100-SEF200 Heavy Duty Sewage Pumps

SH30 High Head Effluent Pump

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

SPC-PANEL Simplex, Single Phase Pump Control Panel

Pump Installation and Service Manual HRS Hydromatic Retractable System

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

Stormpro 2100-DC. OPERATION MANUAL Heavy Duty 12V DC Pump Dated: 04/24/08 Supersedes: 02/04/08 Document No.: Spro2011-DC-OM Page 1 of 7

SUBMERSIBLE SEWAGE PUMPS

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

MODELS WGL20, WGL20H and WGL20F

V2 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

Ion StormPro 55ACi+ & 55ACi Deluxe Battery Backup System

ESE Series Cast Iron Sewage Pumps

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

StormPro 2100DC Heavy Duty 12V DC Pump

Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

30ACi+, 30ACi Deluxe, 35ACi+ and 35ACi Deluxe Battery Backup System

SUBMERSIBLE SUMP PUMPS

SUMPRO Battery Back-Up

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

SUBMERSIBLE SUMP PUMPS

PRE-PLUMBED SEWAGE SYSTEM

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

Pump Installation and Service Manual SK60 Submersible Sewage Ejector Pump

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

PUMP VAULT S.T.E.P. SYSTEM

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

INSTALLATION & SERVICE MANUAL

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

SUNC3000 / Item #40885

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

SUMPRO Battery Back-Up

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

MODELS WG/WGX20* GRINDER PUMP. *Used in Hazardous Locations Class I, Division 1, Groups C & D INSTALLATION AND SERVICE MANUAL

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

Matala. VersiFlow Series. Instruction and Maintenance Manual

Pump Installation and Service Manual SK75/100 Submersible Sewage Ejector Pumps

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

2460 / 2472 / Series Simplex Grinder Systems

SP40 Submersible Sewage Ejector Pump

SHEF30 Submersible Sump/ Effluent Pump

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

HR-20P Pneumatically Controlled Pressure Regulator

SUBMERSIBLE BASIN MIXER

Portable Utillity Submersible Pump Model: UT17-1/6 Hp, 120 Volt, 60Hz, 1Ph

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

INSTALLATION INSTRUCTIONS RECOMMENDED MODELS

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

GeyserMax-Flow Series

Installation Manual. Q Series Quadplex Grinder Systems. Contents

MODEL SPC-PANEL. Pump Controls for 2 HP Grinder Pumps

INSTALLATION AND SERVICE INSTRUCTIONS KER KEEN PUMP - e/one Replacement

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

HYDROMATIC. G1X200/G1LX200 Explosion Proof Submersible Grinder Pumps (Class I, Division 1, Groups C & D): FM. Pump Installation and Service Manual

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

MODELS HPGFX/HPGHX & HPGFHX/HPGHHX

SIMPLEX, SINGLE PHASE PUMP CONTROL PANEL Model SPC-PANEL Pump Controls for 2 HP Grinder Pumps

MODELS HPGF/HPGFH, HPGH/HPGHH

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

SUPER PUMP OUT SYSTEM

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

EBARA Fluid Handling

Operating and Installation Instructions

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Air Curtain. Installation, Operating and Maintenance Instructions

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

INSTALL GUIDE Dodge/RAM 5.7L HEMI

Owner s Manual Drill and Light Weight Portable Utility Pumps

HPGB750/1000/1500. Submersible Grinder Pumps. Pump Installation and Service Manual

II DISTRIBUTION & SUBSTATION TYPE C

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

WARNING. Instructions for Guidelights and Chargers. How SnapPower Products Work

HALLMARK INDUSTRIES INC

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

S4HVX Submersible Pump with Explosion-Proof Motor End (Class I, Division 1, Groups C & D): FM For use with product built with USEM motor.

Installation and Operation Instructions Safety Director Arrow

430B SERIES HORIZONTAL SPLIT CASE PUMP

Transcription:

Page 1 of 8 equipment and follow handling procedures per OSHA 29 CFR 1910.1030 when handling equipment after waste water source has been connected to system. WARNING: Risk of Asphyxiation. Installer(s) and/or service personnel must use proper personal protective equipment and follow OSHA 29 CFR 1910.146 or OSHA 29 CFR 1926. Pump may be installed in a location classified by as a confined space. WARNING: Risk of fire or explosion. Do not smoke or use open flames in or around this system. This system is not intended for use in hazardous locations per NFPA 70 National Electric Code. Do not pump flammable liquids. Consult factory for optional equipment rated for hazardous location use. Safety Warnings Thank you for purchasing your Ion Technologies Pump. To help ensure years of trouble-free operation, please read the following manual carefully. pump. CAUTION: Read these safety warnings first before installing, servicing, or operating any This manual contains important information for the safe use of this product. Read this manual completely and follow the instructions carefully. Reasonable care and safe methods relating to the installation and operation of this product should be practiced. Check local codes and requirements before installation. WARNING: Risk of electrical shock or electrocution. May result in serious injury or death or fire hazard. Installer must disconnect all electrical sources prior to installation, handling or servicing. Only qualified personnel may install this system. NFPA 70/National Electric Code (NEC) or local codes must be followed. System must be properly grounded according to NEC. Do not lift pump by power cord. WARNING: Biohazard risk. Once waste water source has been connected to system, biohazard risk exists. Installer(s) and/or service personnel must use proper personal protective WARNING: Cutting risk. Risk of serious cutting or amputation exists. Disconnect all power sources prior to servicing pump. Pump may start without warning. CAUTION: Do not modify the cord and plug. When using the cord plug into a grounded outlet only. When wiring to a system control, connect the pump ground lead to the system ground. CAUTION: Do not run the pump dry. Dry running can overheat the pump (causing burns to anyone handling it) and will void the warranty. The pump normally runs hot. To avoid burns, allow it to cool for 30 minutes after shut down before handling it. Submersible sump pumps are not approved for use in swimming pools, recreational water installations, decorative fountains or any installation where human contact with the pumped fluid is common. Do not throw away or lose this manual. Keep it in a safe place so that you may refer to it often for the continued safe operation of the product. Overview The MSP-SHR & MSP-HR Series are solids handling pumps that can be used to pump RAW SEWAGE for COMMERCIAL and DOMESTIC use, but are not intended to handle large rags, mop heads or strings.

Page 2 of 8 All pumps can be used for normal sewage duty where extra capacity is required. Recessed Impellers All of the pumps are of the recessed impeller type that provides a clear volute passage for solids as no solids pass through the impeller. All of the pumps listed can be used to pump septic tank effluent or ground sewage as used in some pressure sewer systems. WARNING: These pumps are not approved for, and should not be used in swimming pools, fountains or marine areas. Air Locking A sewage pump is air locked if water traps air in the pump and it cannot get out, thus preventing the pump from operating. In installations of this type a 1/8" hole should be drilled in the discharge pipe below the check valve. The check valve should be 12 to 18 inches above pump discharge. Do not put check valve directly into pump discharge opening. Motor Types All single phase pump motors are of the permanent split capacitor type that do not require a start switch or start relay. Automatic reset overload switches are attached directly to the motor windings. Three phase pump motors are squirrel cage induction type. Installation Pumps can be installed inside sealed basins with proper venting for either simplex or duplex systems. Pumps can be installed in a compartment of septic tanks for pumping to pressure sewer mains, gravity sewers, leach fields, or evaporation mounds. WARNING: Basin must be vented in accordance with local plumbing codes. These pumps are not designed for and CANNOT be installed in locations classified as hazardous in accordance with the National Electric Code ANSI/NFPA 70. Piping Pumps are fitted with 2" female threaded pipe flange. Galvanized or PVC plastic pipe can be used. Plastic pipe is preferred for raw sewage or septic tank effluent. Check & Shut-Off Valves All pumps must have check valves and shut-off valves in the discharge line. Check valves must be flapper type with outside spring or ball type. Shut-off valves can be ball or gate type. Plastic construction for both check or shut-off valves is acceptable. WARNING: Always have electrician make electrical checks. CAUTION: never work on pumps or control boxes until circuit breakers are turned off. Always have a qualified electrician make electrical connections and service checks. Special Instructions The following are special instructions for 3-Phase pumps. WARNING: Only qualified persons shall conduct services and installations of this pump. The pump must be wired by a qualified electrician, using an approved starter box and switching device.. CAUTION: Risk of electric shock. Do not remove cord and strain relief. Do not connect conduit to pump. Three phase pumps are always installed with control boxes having magnetic starters with 3-leg overload protection. Do not try to run three phase pumps

Page 3 of 8 directly across the line. To Connect Pump Run wire from pump to the control box or appropriate junction box suitable for enclosing splice connections. With power off, connect green (ground) line to ground lug. Connect black (power) wires to power lead terminals. Make sure that all wires are not in a position to be pinched or shorted when installed. See wiring diagrams, page 5. All three phase motors can run in either direction. Rotation can be changed by interchanging any two line leads at magnetic starter. CAUTION: Be sure circuit breaker is off before making this change. To find if rotation is correct operate pumps and check delivery operation. If flow and head is slow (refer to pump curve shown in this manual) the rotation is wrong. With duplex pumps check operation of both pumps. All pump impellers either single or three phase must turn counterclockwise when looking into pump inlet. If uncertain of rotation, turn off power and lift pump from basin with cord connected and lay pump on side so impeller can be seen. Turn on power and start pump using hand position of H-O-A switch. Turn on and off fast, so that coast of impeller can be seen. WARNING: Never put hand or fingers on the impeller. Interchange any two line leads at the magnetic starter to change rotation. Troubleshooting Pump does not run or start when water is up in tank. 1. Check for blown fuse or tripped circuit breaker. times. If this does not help it may be necessary to loosen a union in the discharge line to relieve air lock. 2. Check valve may be installed backward. Check flow arrow on valve bod. Check shut-off valve. It may be closed. 3. Check vertical elevation. It may be higher than pump can develop. (See pump curve page 4.) 4. Pump inlet may be plugged. Remove pump to check. CAUTION: Follow proper lockout procedure before working on pump. If control panel is remote from pump, disconnect lead wires to motor so that no one can turn the circuit breaker back on. Motor Data Model HP Volts Phase Hertz MSP-SHR50-11 ½ 115 1 60 MSP-SHR50-21 ½ 230 1 60 MSP-SHR50-23 ½ 230 3 60 MSP-SHR100-21 1 230 1 60 MSP-SHR100-23 1 230 3 60 MSP-SHR150-21 1 ½ 230 1 60 MSP-SHR150-23 1 ½ 230 3 60 MSP-SHR200-21 2 230 1 60 MSP-SHR200-23 2 230 3 60 MSP-HR50-11 ½ 115 1 60 MSP-HR50-21 ½ 230 1 60 MSP-HR50-03 ½ 208 3 60 MSP-HR50-23 ½ 230 3 60 MSP-HR50-43 ½ 460 3 60 2. Check for burned-out motor. Occasionally lightning can damage a motor even with lightning protection. 3. Where plug-in cords are used be sure contact blades are clean and making good contact. Do not use plug-in cords inside a basin or wet well. Pump runs but does not deliver flow 1. Check for air lock. Start and stop pump several

Page 4 of 8 MSP-SHR Dimensions MSP-HR Dimensions

Page 5 of 8 MSP-SHR Performance MSP-HR Performance

Page 6 of 8 Wiring Diagrams 230 V 1 Phase, P.S.C 230 V 3 Phase 230 V 3 Phase (1-2 HP) 3 Phase Dual Voltage Winding Voltage Leads Black White Red Together 230 1 & 7 2 & 8 3 & 9 4 & 5 & 6

Page 7 of 8 Notes:

Page 8 of 8 Warranty 1. Coverage and Term. Metropolitan Industries, Inc. ( Metropolitan ) warrants to the original purchaser (the Buyer ) of each Ion product (the product ), that any part thereof which proves to be defective in material or workmanship within one (1) year from date of installation or 18 months from the date of manufacture, whichever comes first, will be replaced at no charge with a new or remanufactured part, F.O.B. factory. Buyer shall be responsible for all freight charges and all costs of field labor or other charges incurred in the removal and/or reinstallation of any product, part or component thereof. 2. Exclusions. THE WARRANTY IS SUBJECT TO THE FOLLOWING CONDITIONS AND EXCLUSIONS: (a) The Warranty excludes products or workmanship which becomes defective as a result of: (i) earthquake, fire, storms, the elements or any other acts of God; (ii) normal wear and tear from use; (iii) accident, misuse, abuse or neglect ; (iv) modifications made by Buyer or any third party, other than Metropolitan; and (v) Buyer s failure to properly install, maintain, service and/or operate the product under normal conditions and according to manufacturer s instructions. (b) Metropolitan shall not be responsible for, and the Warranty shall not cover, extended damage which occurs because of Buyer s failure to notify Metropolitan promptly in writing of apparent defects. (c) Any part or component designated as manufactured by anyone other than Metropolitan shall be covered only by the express warranty of the manufacturer thereof. (d) The Warranty shall lapse upon Buyer s failure to fully comply with the terms and conditions of its contract with Metropolitan, including Buyer s failure to pay the purchase price for the product or any portion thereof. Buyer s subsequent compliance with the terms and conditions of any such contract, will not cause the term of the Warranty to extend beyond the time period set forth above. (e) No actions taken by Metropolitan to correct a defect in a product shall extend the Warranty beyond the period set forth above. Metropolitan shall not be obligated to remedy any defect, where otherwise required pursuant to the Warranty unless and until Buyer notifies Metropolitan in writing of the defect and then only if such notification is made prior to the expiration of the period set forth above. 3. Process of Claims and Repairs. Metropolitan agrees that if the product or any part or component thereof shall fail to conform to the terms of this Warranty, Metropolitan shall replace such nonconforming product, part or component at the original point of delivery and furnish instruction for its disposition. Any transportation charges involved in such disposition and all costs of field labor or other charges incurred in the removal and/or reinstallation of any product, part or component thereof shall be the responsibility of Buyer. 4. Limitation on Liability. Notwithstanding any provision to the contrary, Metropolitan s entire liability under this Warranty shall not in the aggregate exceed, and Buyer s exclusive and sole remedies are, to the extent permitted by law, shall be to secure replacement of the defective product. UNDER NO CIRCUMSTANCES SHALL METROPOLITAN BE LIABLE UNDER THE WARRANTY FOR ANY INDIRECT, PUNITIVE, SPECIAL, EXEMPLARY, CONSEQUENTIAL OR INCIDENTAL DAMAGES (INCLUDING LOST PROFITS, REVENUE, USE OR ECONOMIC ADVANTAGE). 5. Express Waiver of Any Other Warranties. THE EXPRESS WARRANTY SET FORTH IN THIS WRITTEN WARRANTY IS THE ONLY WARRANTY MADE BY METROPOLITAN, OR ANY OTHER PARTY, IN CONNECTION WITH ANY PRODUCT PURCHASED FROM METROPOLITAN. NEITHER METROPOLITAN, NOR ANY OTHER PARTY, MAKES ANY OTHER EXPRESS OR IMPLIED WARRANTY WHICH IS NOT SET FORTH HEREIN, AND METROPOLITAN HEREBY DISCLAIMS AND BUYER HEREBY WAIVES ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. 6. Not Transferable. The Warranty may not be transferred and shall be void on the sale or other transfer of the product. 7. Products and Warranty Subject to Change. Metropolitan reserves the right to make revisions to its products and their specifications, and to revise this Warranty and related information without notice.