Product Bulletin. Be Certain with Belden. Belden DataTwist 1200 Cables

Similar documents
LANmark-1000 Category 6 Plenum

PureNet Data Communication Products Premises Copper Products

Outlets terminate all shielded and shielded cable constructions AWG ( mm) size conductors.

DataTwist 600e U / UTP Cables TIA/ EIA-568-B.2-1, Category 6, Enhanced Category 6 Bonded-Pair Cables

Detailed Specifications & Technical Data

Test Report Number: G CRT-039f

75 OHM COAXIAL CABLE (RG6)

Part Number: 10GX F/UTP CMR PATCH CORDS 10GX F/UTP CMR Patch Cords

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant

Part Number: CAT6+ UTP CMR PRE-TERM 6 CAT6+ UTP CMR Pre-Term 6

Security Coaxial Cable

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

Volition. Fiber Optic Cable. 3Innovation

Data sheet Patch cord Cat.6 A AWG m gray

Fiber Optic, Breakout cable, tight buffered, 900 microns

DATA Cable Connecting the world by TAIHAN

Mining and Petrochemical Tray-Rated Fiber Optic Cables

Data sheet Patch cord Cat.6 A AWG m black

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

Variable Frequency Drive (VFD) Cable Solutions

MIC Plenum Cables, 2-24 Fibers

Detailed Specifications & Technical Data

UNSHIELDED MULTI CONDUCTOR

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/

EcoSystem Bus Cable. EcoSystemTM. Cable. Low Voltage Cables

Data sheet. E-DAT Industry RJ45 field plug PROFINET. Illustrations P/N PI EAN Product specification. Page 1/

PowerCat 6 STP DataGate Plus TM

Detailed Specifications & Technical Data

06. har-mik INTERFACE CONNECTORS

Data sheet E-DAT Industry terminal rail TS35 + RJ45 coupler insert Cat.6 Class E A

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6A, light gray

2001 PRODUCT CA T ALOG

P R O D U C T C AT A L O G T ALOG

MIC Unitized Plenum Cables, Fibers

Data sheet C6 A modul 24 port 180 M 1RU stainless steel

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/

Technical Data Sheet Shielded (CY) PVC Control Cable

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

6000 Series Ethernet Buccaneer

Data sheet. E-DAT modul REG 1 port IP20 light gray. Illustrations P/N E EAN Product specification. Page 1/

Ethernet Buccaneer BUCCANEER DATA. bulgin

Data sheet E-DAT subway 9 port GB3 pearl white

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut

Flame Resistance, LOI 95 >

Multi-band Bi-SectorTM Array

Ethernet Buccaneer IP68 BUCCANEER FOR DATA BUCCANEER DATA

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6 A, stainless steel

MPO MicroCable Trunk Assembly

Application Specification. Optical Fiber. Aramid Yarns. 2mm Subunit Jacket. Strength Rods. Outer Jacket

Data sheet E-DAT modul Cat.6 A 8(8) jack, T568A

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.

Laser Optimized Multimode

XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET

Easier! Faster! Safer!

Data sheet C6 A modul 6 port 180 M GB3 pearl white

DataTwist. Cables. DataTwist 600 I-STP - Belden 1888NH. Description

Technical Data Sheet Unshielded (YY) PVC Control Cable

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

SFUSD Project Number: EXHIBIT D ARGONNE DESIGN DRAWINGS


Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

Interconnect Cable Simplex and Duplex

Unarmoured Single-Core Cables to BS6883

6491B / H07Z-R / BS EN Cable

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

GROUNDING & BONDING PRODUCTS

Data sheet E-DAT Industry RJ45 coupler insert Cat.6 Class E

Standard hook-up wires and cables for Electronics Filotex

Industrial Ethernet Cables

Technical Data Sheet Shielded (CY) PVC Control Cable

The cables you need when you need them

EcoSystem Cable Low-Voltage Cables. Features Internal conductors match EcoSystem device terminal and lead color scheme.

Data sheet C6 A RJ45 field plug pro

Data sheet E-DAT C6 A 24 port patch panel 1RU LSA modular

Basic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S

Cables for Railway Technology

Omni Cable is a master distributor of specialty wire and cable selling

Technical Data Sheet Unshielded (YY) PVC Control Cable

SHIELD-FLEX EMI / RFI Shielded Conduit

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

ÖLFLEX CLASSIC 110 H Info Benefits

Introduction. Selection Guide: Shielded Multi-Conductor Computer Cables for RS-232 Applications. Multi Applications Demand Multiple Choice

Data sheet Connection line M12 plug straight - RJ45 plug straight 8-pole, X-coded 5.0 m

PHASE MASTER NOW IN 4 SIZES

Single Cable Motion Solution Kinetix 5500 Servo Drive and VP Low Inertia Motor

flame Retardant overall screened Instrumentation cables (Multicore)

CABLED SINGLE CONDUCTORS

TEK Brief July Is there a difference in installation requirements between communications cables with and without the LP designation?

Variable Frequency Drive (VFD) Cable Solutions

127 (5) Approx (1.85) Overmold. Male Coupling Nut. Straight Micro Female 63.5 (2.5) 127 (5) Approx. Overmold Coupling Nut Straight Mini Female

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

SHIELD-FLEX EMI / RFI Shielded Conduit

WHITE PAPER. Optimizing High-Power PoE

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

Data sheet E-DAT modul 1 port UPk Cat.6 A, pure white

Transcription:

Product Bulletin PB 294 Belden DataTwist 1200 Cables DataTwist 1200 UTP Cables are part of the industry s most powerful Category 5e networking solution: Belden IBDN System 1200. DataTwist 1200 Cables exceed the TIA/EIA Category 5e requirements and have excellent PSNEXT, PSACR and return loss characteristics. DataTwist 1200 Cables Provide Excellent Mechanical and Electrical Performance for Category 5e Networks Be Certain with Belden DataTwist 1200 Cable If your business is riding the wave of growth and expansion, you may be considering new ways of doing business and therefore a new or upgraded IT system to support these strategies. This is the ideal time to plan and implement new cabling or to upgrade your existing infrastructure. DataTwist 1200 Cables were developed to support high-speed network applications such as Gigabit Ethernet. Ideal for supporting up to 1000BASE-T, this cable was designed to exceed current standards, providing built-in margin and optimizing network performance. DataTwist 1200 Cables consist of 4 pairs of 24 AWG insulated copper conductors with a round flexible core construction. The patented design features matched conductors on all four pairs, which provides for extremely stable electrical performance. Depending on your application requirements, DataTwist 1200 Cables can be specified in a standard Nonbonded-Pair design or in Belden s exclusive Bonded-Pair construction (DT350). All DataTwist 1200 Cables feature a small diameter (0.2 in. or less) for higher density installations especially valuable for runs inside conduit. For the installer, the DataTwist 1200 Cables come with a unique descending sequential printing scheme that shows exactly how much cable remains on the spool or in the box. And that translates into faster installations with less waste. Belden DataTwist 1200 Cables are part of the Belden IBDN 1200 System. Belden s 1200 System substantially exceeds all requirements for Category 5e channels per the TIA/EIA-568-C.2 standard. Certified to support data rates up to 1.2 Gb/s for a system with usable bandwidth of 160 MHz, the 1200 Solution provides the advanced performance required to fully support today s broad spectrum of business applications.

DataTwist 1200 Cables The Belden IBDN 1200 Solution provides the advanced performance required to fully support today s broad spectrum of business applications. Applications DataTwist 1200 Cables are intended to be used for horizontal cable installations of high speed Local Area Networks (LANs) for transmission speeds up to 1.2 Gb/s. Specific applications include: 1000BASE-T Applications (IEEE 802.3ab) Power Over Ethernet Plus 2 pairs, up to 24 Watts or 4 pairs, up to 48 Watts (IEEE 802.3at) Power Over Ethernet 2 pairs, up to 12.95 Watts (IEEE 802.3af) High Temperature performance up to 50 C, with up to 10 m length de-rating for 1000BASE-T and 100BASE-TX High Noise Immunity with a Noise Reduction Factor of 1.0 (TIA 569B) VoIP Applications Features & Benefits Minimized skew for parallel transmission protocols High flexibility design eases cable installation and dressing Size minimized for compactness of installations Descending distance marking for cable length reduces waste Matching tip and ring color code for ease of installation Available in CMR, CMP and LSZH versions Available in Bonded-Pair or Nonbonded-Pair design Technical Specifications* Physical Characteristics Conductors: 24 AWG solid copper Insulation - Plenum: Bonded-Pair: 100% FEP Nonbonded-Pair: Dual Insulation FEP over a Polyolefin base - Riser and LSZH: Polyolefin Cable Core: Four twisted pairs formed into a cable core Jacket with Rip Cord: - Plenum: LSPVC - Riser: PVC - LSZH: Low Smoke Zero Halogen Polymer Alloy - Jacket printed at intervals indicating cable code, AWG, listings (NEC Code), verification, date, manufacturing traceability code - Descending length markings start at highest number and end at 0 2

Mechanical Characteristics Minimum Recommended Installation Temperature: 5 C (40 F) Temperature Rating: 60 C (140 F) Transmission Characteristics Values up to 350 MHz are minimum guaranteed values (250 MHz for Nonbonded-Pair) Values above 350 MHz for engineering purposes only (250 MHz for Nonbonded-Pair) DC Resistance @ 20 C, max.: 8.9 ohms/100 m DC Resistance Unbalance, max.: 3% Mutual Capacitance, nom.: 5.6nF/100 m Capacitance Unbalance Pair to Ground, max.: Bonded-Pair: 66pF/100 m Nonbonded-Pair: 330pF/100 m Input Impedance: Input Impedance Bonded-Pair Nonbonded-Pair 100±12 1-20 MHz 100±15 20-100 MHz 1-100 MHz 100±18 100-200 MHz 100±20 200-310 MHz 100±22 310-350 MHz 100-250 MHz Nominal Velocity of Propagation (NVP): - Plenum: 72% @ 10 MHz - Riser: 70% @ 10 MHz Propagation Delay (Skew), max.: 25ns/100 m Qualifications Category 5e requirements per ANSI/TIA/ EIA-568-A.5 or TIA/EIA-568-C.2, ISO/IEC 11801 ed 2.1 (2008) Class D, EN50173 (2007) Riser: ITS/ETL Certified as CMR, and listed as NEC Type CMR per UL Standard 444, IEC 60332-3 Plenum: ITS/ETL Certified as CMP, and listed as NEC Type CMP per UL Standard 444 LSZH: IEC 60332-1, IEC 60754, IEC 61034 Select Bonded-Pair or Nonbonded-Pair Construction Belden provides the option of ordering DataTwist 1200 Cables in either Bonded-Pair or Nonbonded-Pair constructions. The choice will depend on the type of signals supported, the critical nature of the information transmitted, and the stability of the networking environment. Belden s Bonded-Pair Cables feature a patented design in which the individual conductors are securely bonded along their longitudinal axis to guarantee uniform spacing within each twisted pair a key factor in maintaining consistently high electrical performance. Because Belden s Bonded-Pair Cables have better centricity and symmetry, they provide improved return loss and balance performance. Superior transverse conversion loss (TCL), capacitance unbalance and resistance unbalance results in the cabling infrastructure being less susceptible to electromagnetic and radio frequency interference (EMI/RFI). Belden s ultra-robust Bonded-Pair Cables can provide additional peace of mind, especially when deployed in: Mission-critical data centers Frequently changing networking environments where constant moves, adds and changes are routine Environments where electromagnetic and radio frequency interference (EMI/RFI) create noise and signal transmission problems In stable networking environments, Belden s standard DataTwist 1200 Cables will perform reliably to meet or exceed TIA/EIA Category 5e Key Physical Attributes DataTwist 1200 Bonded-Pair (DT350) Cable 4-pair, 24 AWG Bonded-Pair Nominal O.D. Min. Bend Radius Weight (Cable Only) CMR (1700A) 5.08 mm 6.35 mm 32.66 kg/km (0.200 in.) (0.25 in.) (22.0 lb/kft) CMP (1701A) 4.95 mm 6.35 mm 32.66 kg/km (0.195 in.) (0.25 in.) (22.0 lb/kft) LSZH and Limited Combustible versions available upon request. Nonbonded-pair Bonded-Pair Installed and manipulated nonbonded-pairs (left) have a tendency to gap, varying the centricity of the two conductors. Belden Bonded-Pairs (right) do not gap so the physical integrity of the pair is maintained. standards. When the application calls for a more robust solution, Belden Bonded-Pair DataTwist 1200 Cables will provide superior integrity and electrical performance from the reel to real life through all the stresses of installation and post-installation maintenance. Belden calls this unique capability Installable Performance. Visit www.belden.com to learn more about Belden s Bonded-Pair construction and its unique benefits. Key Physical Attributes DataTwist 1200 Nonbonded-Pair Cable 4-pair, 24 AWG Nonbonded-Pair Nominal O.D. Min. Bend Radius Weight (Cable Only) CMR (1212) 5.08 mm 20.32 mm 32.66 kg/km (0.200 in.) (0.800 in.) (22.0 lb/kft) CMP (1213) 5.08 mm 20.32 mm 32.66 kg/km (0.200 in.) (0.800 in.) (22.0 lb/kft) LSZH (1224) 5.03 mm 20.12 mm 29.69 kg/km (0.198 in.) (0.792 in.) (20.0 lb/kft) Limited Combustible version available upon request. * Values are the same for Bonded-Pair and Nonbonded-Pair Cables, unless specifically noted. 3

Ordering Information DataTwist 1200 Bonded-Pair (DT350), 4-pair, 24 AWG, CMR, Category 5e Both Bonded-Pair and Nonbonded-Pair DataTwist 1200 Cables are offered in plenum, riser and LSZH versions. 1700A B02U1000 Purple 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1700A F2VU1000 Light Gray 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1700A 002U1000 Red 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1700A 003U1000 Orange 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1700A 004U1000 Yellow 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1700A 005U1000 Green 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1700A 006U1000 Blue 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1700A 008U1000 Gray 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1700A 009U1000 White 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1700A 010U1000 Black 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1700A B021000 Purple 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1700A F2V1000 Light Gray 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1700A 0021000 Red 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1700A 0031000 Orange 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1700A 0041000 Yellow 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1700A 0051000 Green 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1700A 0061000 Blue 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1700A 0091000 White 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1700A 0101000 Black 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1700A F2V3000 Light Gray 915 m (3000 ft) Spool 16 spools/pallet 14640 m (48000 ft) 1700A 0023000 Red 915 m (3000 ft) Spool 16 spools/pallet 14640 m (48000 ft) 1700A 0063000 Blue 915 m (3000 ft) Spool 16 spools/pallet 14640 m (48000 ft) 1700A 0093000 White 915 m (3000 ft) Spool 16 spools/pallet 14640 m (48000 ft) DataTwist 1200 Bonded-Pair (DT350), 4-pair, 24 AWG, CMP, Category 5e 1701A B02U1000 Purple 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1701A 002U1000 Red 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1701A 003U1000 Orange 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1701A 004U1000 Yellow 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1701A 005U1000 Green 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1701A D15U1000 Blue 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1701A 008U1000 Gray 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1701A 009U1000 White 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1701A 010U1000 Black 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1701A 877U1000 Natural 305 m (1000 ft) UnReel Box 36 boxes/pallet 10980 m (36000 ft) 1701A B021000 Purple 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1701A 0021000 Red 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1701A 0031000 Orange 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1701A 0041000 Yellow 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1701A 0051000 Green 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1701A D151000 Blue 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1701A 0081000 Gray 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1701A 0091000 White 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1701A 0101000 Black 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1701A 8771000 Natural 305 m (1000 ft) Spool 64 spools/pallet 19520 m (64000 ft) 1701A D153000 Blue 915 m (3000 ft) Spool 16 spools/pallet 14640 m (48000 ft) 1701A 8773000 Natural 915 m (3000 ft) Spool 16 spools/pallet 14640 m (48000 ft) LSZH and Limited Combustible versions available upon request. 5

Ordering Information (continued) DataTwist 1200 Nonbonded-Pair, 4-pair, 24 AWG, CMR, Category 5e 1212 003U1000 Orange 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1212 004U1000 Yellow 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1212 005U1000 Green 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1212 006U1000 Blue 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1212 008U1000 Gray 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1212 009U1000 White 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1212 010U1000 Black 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1212 0041000 Yellow 305 m (1000 ft) Spool 60 spools/pallet 18300 m (60000 ft) 1212 0061000 Blue 305 m (1000 ft) Spool 60 spools/pallet 18300 m (60000 ft) 1212 0091000 White 305 m (1000 ft) Spool 60 spools/pallet 18300 m (60000 ft) 1212 0062500 Blue 762 m (2500 ft) Spool 27 spools/pallet 20574 m (67500 ft) 1212 0092500 White 762 m (2500 ft) Spool 27 spools/pallet 20574 m (67500 ft) DataTwist 1200 Nonbonded-Pair, 4-pair, 24 AWG, CMP, Category 5e 1213 D15A1000 Blue 305 m (1000 ft) Spool-in-Box 36 boxes/pallet 10980 m (36000 ft) 1213 009A1000 White 305 m (1000 ft) Spool-in-Box 36 boxes/pallet 10980 m (36000 ft) 1213 003U1000 Orange 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1213 004U1000 Yellow 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1213 005U1000 Green 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1213 007U1000 Purple 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1213 008U1000 Gray 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1213 009U1000 White 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1213 010U1000 Black 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1213 012U1000 Pink 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1213 D15U1000 Blue 305 m (1000 ft) TrapEZ Box 45 boxes/pallet 13725 m (45000 ft) 1213 D151000 Blue 305 m (1000 ft) Spool 60 spools/pallet 18300 m (60000 ft) 1213 0091000 White 305 m (1000 ft) Spool 60 spools/pallet 18300 m (60000 ft) 1213 D152500 Blue 762 m (2500 ft) Spool 27 spools/pallet 20574 m (67500 ft) 1213 0092500 White 762 m (2500 ft) Spool 27 spools/pallet 20574 m (67500 ft) DataTwist 1200 Nonbonded-Pair, 4-pair, 24 AWG, LSZH, Category 5e 1224 007U1000 Purple 305 m (1000 ft) UnReel Box 45 boxes/pallet 13725 m (45000 ft) Limited Combustible version available upon request. To learn more about Belden IBDN copper-based structured cabling systems call 1.800.BELDEN.1 or visit our Website at www.belden.com. 6 Belden Technical Support 1.800.BELDEN.1 (1.800.235.3361) Copyright 2011, Belden Inc. www.belden.com PB294

Technical Specifications (continued) Key Electrical Attributes DataTwist 1200 Bonded-Pair (DT350) Cable Frequency Max. Insertion Loss (db/100 m) THE BONDED-PAIR ADVANTAGE Min. PSNEXT (db) Min. PSACR (db) Min. PSACRF (db) Min. Return Loss (db)* Min. Balance TCL (db)* Min. Balance ELTCTL (db)* (MHz) TIA Belden TIA Belden TIA Belden TIA Belden TIA Belden TIA Belden TIA Belden 1 2.0 2.0 62.3 68.3 60.3 66.3 60.8 64.8 20.0 20.0-40.0-35.0 4 4.1 4.0 53.3 59.3 49.2 55.3 48.8 52.8 23.0 23.0-40.0-23.0 8 5.8 5.7 48.8 54.8 43.0 49.1 42.7 46.7 24.5 24.5-40.0-16.9 10 6.5 6.4 47.3 53.3 40.8 46.9 40.8 44.8 25.0 25.0-40.0-15.0 16 8.2 8.1 44.2 50.2 36.0 42.1 36.7 40.7 25.0 25.0-38.0-10.9 20 9.3 9.1 42.8 48.8 33.5 39.7 34.8 38.8 25.0 25.0-37.0-9.0 25 10.4 10.2 41.3 47.3 30.9 37.1 32.8 36.8 24.3 25.0-36.0-7.0 31.25 11.7 11.4 39.9 45.9 28.2 34.5 30.9 34.9 23.6 25.0-35.1 - - 62.5 17.0 16.4 35.4 41.4 18.4 25.0 24.9 28.9 21.5 25.0-32.0 - - 100 22.0 21.0 32.3 38.3 10.3 17.3 20.8 24.8 20.1 25.0-30.0 - - 160-27.0-35.2-8.9-20.7-19.0-28.0 - - 200-30.5-33.8-3.3-18.8-19.0-27.0 - - 250-34.4-32.3 - - - 16.8-18.0-26.0 - - 300-38.0-28.2 - - - - - 18.0 - - - - 350-41.4-27.2 - - - - - 17.0 - - - - 400-44.6-26.3 - - - - - 17.0 - - - - 450-47.6-25.6 - - - - - 17.0 - - - - Values above 350 MHz for engineering purposes only. * Belden s Bonded-Pair Cables provide improved return loss and balance performance. Key Electrical Attributes DataTwist 1200 Nonbonded-Pair Cable Frequency Max. Insertion Loss (db/100 m) Min. PSNEXT (db) Min. PSACR (db) Min. PSACRF (db) Min. Return Loss (db) (MHz) TIA Belden TIA Belden TIA Belden TIA Belden TIA Belden 1 2.0 2.0 62.3 68.3 60.3 66.3 60.8 64.8 20.0 20.0 4 4.1 4.0 53.3 59.3 49.2 55.3 48.8 52.8 23.0 23.0 8 5.8 5.7 48.8 54.8 43.0 49.1 42.7 46.7 24.5 24.5 10 6.5 6.4 47.3 53.3 40.8 46.9 40.8 44.8 25.0 25.0 16 8.2 8.1 44.2 50.2 36.0 42.1 36.7 40.7 25.0 25.0 20 9.3 9.1 42.8 48.8 33.5 39.7 34.8 38.8 25.0 25.0 25 10.4 10.2 41.3 47.3 30.9 37.1 32.8 36.8 24.3 24.3 31.25 11.7 11.4 39.9 45.9 28.2 34.5 30.9 34.9 23.6 23.6 62.5 17.0 16.4 35.4 41.4 18.4 25.0 24.9 28.9 21.5 21.5 100 22.0 21.0 32.3 38.3 10.3 17.3 20.8 24.8 20.1 20.1 160-27.0-35.2-8.9-20.7-18.7 200-30.5-33.8-3.3-18.8-18.0 250-34.4-32.3 - - - 16.8-17.3 300-38.0-28.2 - - - - - 16.8 350-41.4-27.2 - - - - - 16.3 400-44.6-26.3 - - - - - 15.9 450-47.6-25.6 - - - - - 15.5 Values above 350 MHz for engineering purposes only. 4