Altivar 61/71 Adjustable Speed Drives Plastic Kits and Power Terminal Kit

Similar documents
Altivar 61/71 Adjustable Speed Drives Spare Parts Kits

ibusway for Data Center

VW3A7702 braking resistor - IP Ohm W

Altivar 58 TRX Adjustable Speed Drive Controllers in Motor Control Centers hp, 480 V or 1 50 hp, 208/240 V Class 8998

Galaxy 300 Battery Breaker Kit G3HTBKIT1

Galaxy Receiving and Unpacking 09/

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Q-Frame Main Circuit Breaker (225 A Maximum) and Adapter Kit Installation onto an NQ Panelboard Class 1640

Galaxy VM. Battery Breaker Box Installation 09/

H- or J-Frame Main Circuit Breaker and Adapter Kit Installation onto an NQ Panelboard Class 1640

/2008 Altivar 12P Baseplate variable speed drives for asynchronous motors Installation manual 09/2009 V28587 B B

Galaxy kva 3:3 and 3:1. Receiving and Unpacking. 380/400/415 and 208/220 V 04/2016.

Instruction Bulletin NF Panelboard Dual Sub-Feed Circuit Breaker Adapter Kit Installation onto an NF Panelboard Class 1670

Symmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016.

Instruction Bulletin Dual Sub-Feed Circuit Breaker and Adapter Kit Installation onto an NQ Panelboard Class 1640

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual

Installation Instructions

Galaxy VM. Modular Battery Cabinets Installation GVMMODBCW, GVMMODBCN 09/

S-Flex Adjustable Speed Enclosed Drive for Pump and Fan Applications

Galaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017.

Electrical Installation

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

S-Flex 212. Adjustable Speed Enclosed Drive Instruction Bulletin Rev. 07, 10/2018. Retain for future use.

S-Flex 212 Adjustable Speed Enclosed Drive

Power Fuse Assembly Replacement (for 3000A 1395 DC Drives)

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

Galaxy Installation 08/

LED Downlight Ceiling Fixtures

AE012 Enclosure for E5x Series Energy Meters With Swing Panel Kit Product Overview

SERVICE INSTRUCTIONS

INSTRUCTIONS INSTALLATION OF LOAD-SHARE TERMINALS FOR VLT DRIVES

Quik-Spec Coordination Panelboard

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

Altivar Regenerative Unit

Installation Instructions 300 A Current Sensor Kit for D1h/D3h/D5h/D6h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Installation Guide. Flame Ionization Detector on a 6890 GC. Accessories G1561A, G1562A, G1591A, G1598A

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

Freedom egen System End-of- Line Functional Checklist

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

Symmetra PX kw 208 V. Installation 01/

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION

Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Installation Instructions For Motor Control Center (MCC) Units

Symmetra PX with Maintenance Bypass

ALTIVAR FLEX58 Chassis Drive Controller Product Selection

Installation Power Management Unit Battery Cables and Battery Harness

Installation Instructions 500 A Current Sensor Kit for F1 F4/F8 F13 Enclosure Sizes VLT Series FC 102, FC 202, and FC 302

Installation and Operating Manual

Electrical network protection VIP30, VIP35. User s manual 12/2008

Installation Guide. Purged Packed Inlet, Electronic Pneumatics Control on 6890 GC Accessory G1551A

Safety and General Information

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual

Model Fixed Rack-Mount Kit

Removable Applied Panel Mounting System

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

dans un panneau de distribution NQ Instruction Bulletin Boletín de instrucciones Directives d'utilisation

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

HP Adjustable Depth Fixed Rail Kit Installation

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

S&C Vista Underground Distribution Switchgear

PowerFlex 700H and 700S AC Drives Frame 9 Main Fan Capacitor Replacement Kit

Installation Guide. Heater Interface Cable for Mass Sensitive Detector Accessory G1590A

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

February 28 th, 2018 UPDATE: Important Product Safety Bulletin Immediate Action Required INSTRUCTIONS FOR FIELD RISK MITIGATION

Owner's/Installation Manual

Electrically Held to Mechanically Latched Contactor

EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE

TS , -850 Series TS , -850 Series TS-57031, TS

Installation Instructions 500 A Current Sensor Kit for D2h/D4h/D7h/D8h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

INSTALLATION INSTRUCTIONS

Altivar Plus User s Manual hp, 460 V, Constant Torque hp, 460 V, Variable Torque

Installation Guide Smart-UPS 1200/1500 VA 100/120/230 Vac Rack-Mount 1U

Purpose This document provides installation instructions for the Gasboy 9820 Pump Interface Kit.

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX

PAD-MOUNTED SWITCHGEAR INSPECTION & MAINTENANCE RECOMMENDATIONS TYPE PSI/II. 15kV 25kV. Qualified Persons

PowerWorx DSX Series GMT Fuse Panel User Manual

Symmetra PX 20 kw. InfrastruXure 208 V. Installation 01/

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Cleaning Flooded Gear

Altivar 31 AC Drives. Simply Smart! For 3-phase asynchronous motors from 0.25 to 20 HP

Product Manual (Revision D) Original Instructions. PM Speed Adjusting Motor for UG-8 Governors. Operation Manual

Extended Battery Cabinet for Nfinity

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

EJ212 Electric Jack 1 Ton (2,000 lbs) Assembly & Operating Instructions

Installation. Introduction

Installation Instructions

Altistart 48 Enclosed Soft Start Controllers hp, 600 V; hp, 480 V; hp, 240 V or hp, 208 V Class 8638 and 8639

Installing a Purged Packed (PP) Inlet

Altistart 48 Y-Range Soft Start Controllers Installation Guide

In addition to this instruction sheet, the following are included in this kit (some additional parts are included for future maintenance):

Altivar Installation Manual. English 07/2013 ST /2013.

Installation, Maintenance and Warranty Flat Plate Battery

PowerFlex 700 Drive - Frame 8 Components Replacement

M7 R52S & R53 Cold Air Intake Installation Guide 53-3M7301

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Electrobar Elite. Instruction Manual. Conductor Bar System. ELITE-03A October 2011 Part Number: R3 Copyright 2011 Electromotive Systems

SEALING DIP CAP INSTALLATION GUIDE

Transcription:

Altivar 61/71 Adjustable Speed Drives Plastic Kits and Power Terminal Kit Instruction Bulletin 30072-453-27 Retain for future use. For Frame Sizes 2 5: ATV61H075M3, -HU15M3, -HU22M3, -HU30M3, -HU40M3, -HU55M3, -HU75M3, -HD11M3X, -HD15M3X, -H075N4, -HU15N4, -HU22N4, -HU30N4, -HU40N4, -HU55N4, -HU75N4, -HD11N4, -HD15N4, -HD18N4 ATV71H037M3, -H075M3, -HU15M3, -HU22M3, -HU30M3, -HU40M3, -HU55M3, -HU75M3, -HD11M3X, -HD15M3X, -H075N4, -HU15N4, -HU22N4, -HU30N4, -HU40N4, -HU55N4, -HU75N4, -HD11N4, -HD15N4, -HD18N4

30072-453-27 Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 11/2009 Contents Contents Hazard Categories and Special Symbols... 4 Product Support... 4 Before You Begin... 5 Introduction... 6 Related Documentation... 8 Receiving, Handling, and Storage... 8 Electrostatic Precautions... 8 Inspecting the Spare Part Kits... 8 Preliminary Recommendations... 9 Qualified Personnel... 9 Working Procedures... 9 Tools Required... 10 Installation Procedures... 10 Power Removal and Bus Voltage Measurement... 10 Discharging Stored Energy in Capacitors... 11 Parts Identification... 12 Replacing the Plastic Kits... 13 Remove/Replace the Power Trap Cover... 13 Remove/Replace the Wiring Trap Cover... 14 Remove/Replace the IP4X Cover and the Top Cover... 15 Remove/Replace the Front Cap... 16 Remove/Replace the Side Caps... 17 Replacing the Power Terminal Block... 18 2009 Schneider Electric All Rights Reserved 3

Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 30072-453-27 Hazard Categories and Special Symbols 11/2009 Hazard Categories and Special Symbols The following symbols and special messages may appear in this document or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. A lightning bolt or ANSI man symbol in a Danger or Warning safety label on the equipment indicates an electrical hazard which, as indicated below, can or will result in personal injury if the instructions are not followed. The exclamation point symbol in a safety message in a manual indicates potential personal injury hazards. Obey all safety messages introduced by this symbol to avoid possible injury or death. Symbol Name Lightning Bolt ANSI Man Exclamation Point DANGER DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a potentially hazardous situation which, if not avoided, can result in death or serious injury. CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury. CAUTION CAUTION, used without the safety alert symbol, indicates a potentially hazardous situation which, if not avoided, can result in property damage. Product Support For support and assistance, contact the Product Support Group. The Product Support Group is staffed from Monday through Friday, 8:00 am until 6:00 pm Eastern time, to assist with product selection, start-up, and diagnosis of product or application problems. Emergency phone support is available 24 hours a day, 365 days a year. Toll free: 888-SquareD (888-778-2733) E-Mail: drive.products.support@us.schneider-electric.com Fax: 919-217-6508 4 2009 Schneider Electric All Rights Reserved

30072-453-27 Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 11/2009 Before You Begin Before You Begin Read and follow these precautions before performing any procedure with this drive. The word drive as used in this bulletin refers to the controller portion of the adjustable speed drive as defined in the National Electrical Code (NEC).. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Read and understand this manual before installing or operating the Altivar 61 or 71 drive. Installation, adjustment, repair, and maintenance must be performed by qualified personnel. The user is responsible for compliance with all international and national electrical code requirements with respect to grounding of all equipment. Many parts of this drive, including the printed circuit boards, operate at the line voltage. DO NOT TOUCH. Use only electrically insulated tools. DO NOT touch unshielded components or terminal strip screw connections with voltage present. DO NOT short across terminals PA/+ and PC/ or across the DC bus capacitors. Before servicing the drive: Disconnect all power, including external control power that may be present. Place a DO NOT TURN ON label on all power disconnects. Lock all power disconnects in the open position. WAIT 15 MINUTES to allow the DC bus capacitors to discharge. Then follow the Bus Voltage Measurement Procedure on page 10 to verify that the DC voltage is less than 42 V. The drive LED is not an indicator of the absence of DC bus voltage. Install and close all covers before applying power or starting and stopping the drive. Failure to follow these instructions will result in death or serious injury. 2009 Schneider Electric All Rights Reserved 5

Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 30072-453-27 Introduction 11/2009 Introduction This instruction bulletin contains replacement procedures for the Altivar 61 (ATV61) and Altivar 71 (ATV71) plastic kits identified in Table 1. Read and understand the instructions in this document and other referenced documents before installing the kits. For parts identification, refer to Figures 1 and 2 on page 12. Table 1: Altivar 61 and 71 Plastic Kits and Power Terminal Kit Kit Catalog No. Description For Use on Drive: Kit Contents VY1A1202 Plastic kit for frame size 2 ATV61H075M3, ATV61HU15M3, ATV61H075N4, ATV61HU15N4, ATV61HU22N4, ATV71H075M3, ATV71HU15M3, ATV71H037M3, ATV71H075N4, ATV71HU15N4, ATV71HU22N4 (1) IP4X cover (1) Wiring trap cover (1) Power trap cover (2) Side caps (1) Top cap VY1A1203 Plastic kit for frame size 3 ATV61HU22M3, ATV61HU30M3, ATV61HU40M3, ATV61HU30N4, ATV61HU40N4, ATV71HU22M3, ATV71HU30M3, ATV71H040M3, ATV71HU30N4, ATV71HU40N4 (1) IP4X cover (1) Front cap (1) Wiring trap cover (1) Power trap cover (2) Side caps (1) Top cap VY1A1204 Plastic kit for frame size 4 ATV61HU55M3, ATV61HU55N4, ATV61HU75N4, ATV71HU55M3, ATV71HU55N4, ATV71HU75N4 (1) IP4X cover (1) Front cap (1) Wiring trap cover (1) Power trap cover (2) Side caps (1) Top cap 6 2009 Schneider Electric All Rights Reserved

30072-453-27 Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 11/2009 Introduction Table 1: Altivar 61 and 71 Plastic Kits and Power Terminal Kit Kit Catalog No. Description For Use on Drive: Kit Contents VY1A1205 Plastic kit for frame size 5B ATV61HD11M3X, ATV61HD15M3X, ATV61HD15N4, ATV61HD18N4, ATV71HD11M3X, ATV71HD15M3X, ATV71HD15N4, ATV71HD18N4 (1) IP4X cover (1) Front cap (1) Wiring trap cover (1) Power trap cover (2) Side caps (1) Top cap VZ3N1205 Power terminal block kit for frame size 5B ATV61HD11M3X, ATV61HD15M3X, ATV61HD15N4, ATV61HD18N4, ATV71HD11M3X, ATV71HD15M3X, ATV71HD15N4, ATV71HD18N4 (1) Power terminal (1) DC warning label (1) Motor warning label (1) Input warning label (240 V) (1) Input warning label (480 V) VY1A1215 Plastic kit for frame size 5A ATV61HU75M3, ATV61HD11N4, ATV71HU75M3, ATV71HD11N4 (1) IP4X cover (1) Front cap (1) Wiring trap cover (1) Power trap cover (2) Side caps (1) Top cap 2009 Schneider Electric All Rights Reserved 7

Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 30072-453-27 Receiving, Handling, and Storage 11/2009 Related Documentation For drive installation instructions, refer to the following documents: Altivar 61 Installation Manual 0.5 to 100 HP, module no. 1760643. Supplementary Instructions to ATV61 Variable Speed Drives Installation Manual Low Horsepower, document no. 30072-452-63. Altivar 61 Installation Manual 75 to 900 HP, module no. 1760655. Supplementary Instructions to ATV61 Variable Speed Drives Installation Manual High Horsepower, document no. 30072-452-49. Altivar 71 Installation Manual 0.5 to 100 HP, module no. 1755843. Altivar 71 Installation Manual 75 to 700 HP, module no. 1755849. Altivar 71 Drive Controllers Errata to Bulletin atv71e_installation_manual_en_v3, document no. 30072-452-25. All documentation referenced in this bulletin is provided with the drive or on the CD-ROM included with the spare parts kits. You can also downioad the documentation from the Technical Library at www.schneider-electric.us. Receiving, Handling, and Storage Electrostatic Precautions CAUTION STATIC SENSITIVE COMPONENTS Circuit boards and option cards can be damaged by static electricity. Observe the electrostatic precautions below when handling controller circuit boards or testing components. Failure to follow these instructions can result in injury or equipment damage. Observe the following precautions for handling static-sensitive components: Keep static-producing material such as plastic, upholstery, and carpeting out of the immediate work area. Store static-sensitive components in protective packaging when they are not installed in the drive. When handling a static-sensitive component, wear a conductive wrist strap connected to the component or drive through a minimum of 1 megohm resistance. Avoid touching exposed conductors and component leads with skin or clothing. Inspecting the Spare Part Kits After receiving the ATV61/ATV71 spare parts kit: Ensure that the catalog number printed on the kit label is the same as that on the packing slip and corresponding purchase order. Contact your Schneider Electric representative if there are any errors. Remove the kit from its packaging and inspect it for damage. If any damage is found, notify the carrier and your Schneider Electric representative. To store the kit, replace any static-sensitive parts in their protective packaging and store them at -25 to +70 C (-13 to +158 F). 8 2009 Schneider Electric All Rights Reserved

30072-453-27 Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 11/2009 Preliminary Recommendations WARNING DAMAGED EQUIPMENT Do not install or operate any equipment that appears damaged. Failure to follow these instructions can result in death, serious injury, or equipment damage. Preliminary Recommendations Qualified Personnel Working Procedures Before beginning the installation procedures, read and understand all the information in this section. For the protection of personnel and equipment, a qualified person must perform the procedures detailed in this instruction bulletin. A qualified person is one who has skills and knowledge related to the construction and operation of this electrical equipment and the installation, and has received safety training to recognize and avoid the hazards involved. Refer to the most current release of NFPA 70E, Standard for Electrical Safety in the Workplace, for safety training requirements. In addition, the person must be: Able to read, interpret, and follow the instructions and precautions in this instruction bulletin and the other documentation referenced. Able to use the required tools listed in this instruction bulletin in a safe and correct manner. Observe the following working procedures: Use only the components provided with the kits listed in Table 1 on page 6. Do not attempt to repair the drive with other spare parts or equipment. If the part being replaced includes labels, ensure that the labels are applied to the replacement part. If the labels are not available in the kit, contact your Schneider Electric representative. Mount the spare parts only in the locations specified in the installation procedures. Route and position the wires as shown in the instructions. Use the wires and cables provided with the spare parts kits or with the drive. Do not modify the wires and cables. Do not route wires and cables outside of the drive enclosure. Observe the hardware and torque requirements specified in the installation procedures. Do not substitute hardware. Carefully segregate and label all removed hardware and parts for use in reassembly of the drive. Mount all panels and covers as specified in the installation procedures. 2009 Schneider Electric All Rights Reserved 9

Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 30072-453-27 Installation Procedures 11/2009 Tools Required Flathead screw driver, 2.5 mm width Torque wrench, 0 5 N m (0 45 lb-in) Voltmeter, 1 1000 Vdc Socket wrench, 7 mm Driver bits: T-20 Torx driver Size 2 magnetic tip Phillips driver Installation Procedures Power Removal and Bus Voltage Measurement DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Read and understand the precautions in Before You Begin starting on page 5 before performing this procedure. Failure to follow these instructions will result in death or serious injury. The DC bus voltage can exceed 1,000 Vdc. Use a properly rated voltage-sensing device when performing this procedure. To measure the DC bus voltage: 1. Disconnect all power. 2. Wait 15 minutes to allow the DC bus to discharge. 3. Measure the voltage of the DC bus between the PA/+ and PC/ terminals to ensure that the voltage is less than 42 Vdc.These terminals are clearly labeled on each drive. 4. If the DC bus capacitors do not discharge completely, contact your local Schneider Electric representative. Do not repair or operate the drive. CAUTION IMPROPER DRIVE OPERATION If the drive is not turned on for a long period, the performance of its electrolytic capacitors will be reduced. If the drive is stopped for a prolonged period, turn the drive on every two years for at least 5 hours to restore the performance of the capacitors, then check its operation. Do not connect the drive directly to line voltage. Increase the voltage gradually using an adjustable AC source. Failure to follow these instructions can result in injury or equipment damage. 10 2009 Schneider Electric All Rights Reserved

30072-453-27 Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 11/2009 Installation Procedures Discharging Stored Energy in Capacitors DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH When the controller is damaged, voltage may remain on certain energy storage capacitors after de-energization of the controller and discharge of the main capacitor bank. Before working on or near assemblies containing energy storage capacitors, verify that the capacitor voltages are less than 42 Vdc. The following assemblies have energy-storing capacitors: Filter board Always check for the presence of voltage using a voltmeter set to the 1000 Vdc scale. When voltage is present, allow the voltmeter to discharge the capacitor s stored charge. Failure to follow these instructions will result in death or serious injury. Capacitors are used throughout the drives as energy storage devices. Some of the capacitors can store potentially lethal amounts of energy during normal controller operation. When power is removed from an undamaged controller, the stored energy in these capacitors is automatically discharged to nonhazardous levels. However, the discharge mechanisms in a damaged controller may not be operating properly, and stored energy may be present on printed circuit boards. Do not touch traces on printed circuit boards, such as the filter board, unless you have first checked for voltage with a voltmeter! To discharge line filter board capacitors, use a voltmeter set to the 1000 Vdc scale. It will take approximately 6.6 minutes for a 10 megohm input impedance voltmeter to discharge a 10 microfarad capacitor from 700 V to less than 42 V. It will take approximately 40 seconds for a 1 megohm input impedance voltmeter to discharge a 10 microfarad capacitor from 700 V to less than 50 V. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Do not use a voltmeter to discharge stored energy on the DC bus capacitors. If the energy on the DC bus capacitors remains greater than 42 Vdc after 15 minutes, contact Product Support. Failure to follow these instructions will result in death or serious injury. 2009 Schneider Electric All Rights Reserved 11

Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 30072-453-27 Installation Procedures 11/2009 Parts Identification Figure 1: Plastic Kit IP4X cover Top cover Side cap (x2) Front cap Wiring trap cover Power trap cover Figure 2: Power Terminal Block Kit NOTE: The Power Terminal Block Kit is for frame size 5B only. Power terminal block Input warning label Motor warning label DC warning label 12 2009 Schneider Electric All Rights Reserved

30072-453-27 Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 11/2009 Installation Procedures Replacing the Plastic Kits IMPORTANT: Label and retain all removed hardware and cables for use in reassembly. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Read and understand the precautions in Before You Begin starting on page 5 before performing this procedure. Before working on this equipment, turn off all power supplying it and perform the DC bus voltage measurement procedure on page 10. Failure to follow these instructions will result in death or serious injury. Remove/Replace the Power Trap Cover 1. Open the power trap cover (see Figure 3) and unsnap it from the drive chassis at the left side. NOTE: To assist with removal, a flathead screwdriver can be used to lift the bottom-left corner of the power trap cover. 2. If you are only replacing the power trap cover, discard the old piece and snap the new cover in place at the left side of the power trap opening. Close the power trap cover. NEXT STEP: If you are also replacing the wiring trap cover, continue with Step 3 on page 14 before replacing the power trap cover. Figure 3: Power Trap Cover (Frame Size 5B Shown) Phillips screw Power trap cover Wiring trap cover 2009 Schneider Electric All Rights Reserved 13

Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 30072-453-27 Installation Procedures 11/2009 Remove/Replace the Wiring Trap Cover 3. With a 1/4 turn, loosen the size 2 Phillips screw (see Figure 3 on page 13) securing the wiring trap cover to the drive chassis, and remove the wiring trap cover. 4. If you are only replacing the wiring trap cover: Remove the Phillips screw (see Figure 3 on page 13) from the old cover and install it in the new cover. Position the new wiring trap cover over the drive chassis and secure it with the size 2 Phillips screw. Finger-tighten the screw 1/4 turn. Replace and close the power trap cover. See Remove/Replace the Power Trap Cover on page 13. NEXT STEP: If you are also replacing the front cap (see Figure 4), continue with Step 5 on page 15 before installing the power trap cover. If you are replacing the power terminal block (see Figure 4), continue with Replacing the Power Terminal Block on page 18 before replacing the wiring trap cover. Figure 4: Wiring Trap Cover Removed (Frame Size 5B Shown) Front cap Power terminal block 14 2009 Schneider Electric All Rights Reserved

30072-453-27 Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 11/2009 Installation Procedures Remove/Replace the IP4X Cover and the Top Cover 5. The IP4X cover (see Figure 5) is attached to the top cover. If you are only replacing the IP4X cover, snap the IP4X cover off of the top cover, install the new IP4X cover, and discard the old one. If you are replacing the top cover, you do not need to remove the IP4X cover. Continue with Step 6. Figure 5: IP4X Cover (Frame Size 5B Shown) Slot (x2) IP4X cover Top cover 6. To remove the top cover, insert a flathead screw driver into the slots (see Figure 5) on each side of the cover, and push towards the outside of the drive until the snaps disengage. 7. If you are only replacing the top cover, discard the old top cover and snap the new one into place. NEXT STEP: If you are also replacing the front cap, continue with Step 8 on page 16. 2009 Schneider Electric All Rights Reserved 15

Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 30072-453-27 Installation Procedures 11/2009 Remove/Replace the Front Cap 8. To remove the front cap: Frame sizes 5A and 5B: push in on two snaps at the bottom of the front cap (see Figure 6) and disengage the cap from the chassis. Frame sizes 3 and 4: only one snap secures the front cap to the chassis. NOTE: A flathead screwdriver can be inserted at the bottom of the front cap to assist with removal. Frame size 2: there is no front cap piece. 9. If you are only replacing the front cap: Discard the old front cap and snap the new one into place. Reinstall the top cover. See Remove/Replace the IP4X Cover and the Top Cover on page 15. NEXT STEP: If you are also replacing the side caps, continue with Step 10 on page 17 before replacing the top cap. Figure 6: Front Cap (Frame Size 5B Shown) Front cap Snap Snap 16 2009 Schneider Electric All Rights Reserved

30072-453-27 Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 11/2009 Installation Procedures Remove/Replace the Side Caps 10. The drive has left and right side caps. To remove either side cap: Slide the cap towards the top of the drive to disengage it, then remove it from the drive chassis. Discard the old side cap and slide the new one into place. Reinstall the top cap. See Remove/Replace the IP4X Cover and the Top Cover on page 15. Figure 7: Side Cap (Frame Size 5B Shown) Side cap 2009 Schneider Electric All Rights Reserved 17

Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 30072-453-27 Installation Procedures 11/2009 Replacing the Power Terminal Block IMPORTANT: Label and retain all removed hardware and cables for use in reassembly. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Read and understand the precautions in Before You Begin starting on page 5 before performing this procedure. Before working on this equipment, turn off all power supplying it and perform the DC bus voltage measurement procedure on page 10. Failure to follow these instructions will result in death or serious injury. 1. Remove the wiring trap cover. See Remove/Replace the Wiring Trap Cover on page 14. 2. Using a size 2 Phillips driver: Remove three screws (A) securing the power wires to terminals R/L1, S/L2, and T/L3. See Figure 8. Remove seven screws (B) securing the bus bars to the power terminal block. See Figure 8. NOTE: Note the names and positions of the terminals for reinstallation. Figure 8: Power Wires (Frame Size 5B) A (x3) B (x7) 18 2009 Schneider Electric All Rights Reserved

30072-453-27 11/2009 Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 Installation Procedures 3. Using a 7 mm socket wrench, remove three standoffs (C) from terminals R/L1, S/L2, and T/L3. See Figure 9. Figure 9: Standoffs (Frame Size 5B) C (x3) 4. Using a T-20 Torx driver, remove two screws (D) securing the left and right sides of the power terminal board to the drive chassis. See Figure 10. Figure 10: Power Terminal Mounting Hardware (Frame Size 5B) D (x2) 5. Slide the power terminal block out from under the bus bars and remove it from the drive. 6. Install the new power terminal block. 7. Using a T-20 Torx driver, secure the power terminal block to the drive chassis with two screws (D, Figure 10). Tighten the screws to 1.1 1.7 N m (9.7 15 lb-in). 2009 Schneider Electric All Rights Reserved 19

Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 30072-453-27 Installation Procedures 11/2009 8. Using a 7 mm socket wrench, install the standoffs at terminals R/L1, S/L2, and T/L3 (C, Figure 9 on page 19). Tighten the standoffs to 1.1 1.7 N m (9.7 15 lb-in). 9. Using a size 2 Phillips driver: Secure the power wires to terminals R/L1, S/L2, and T/L3 with three screws (A, Figure 8 on page 18). Tighten the screws to 1.1 1.7 N m (9.7 15 lb-in). Secure the bus bars to the power terminal block with seven screws (B, Figure 8 on page 18). Tighten the screws to 1.1 1.7 N m (9.7 15 lb-in). 10. Reinstall the wiring trap cover. See Remove/Replace the Wiring Trap Cover on page 14. 20 2009 Schneider Electric All Rights Reserved

Plastic Kits and Power Terminal Kit for Altivar 61/71 Drives, Frame Sizes 2 5 Instruction Bulletin Schneider Electric 8001 Knightdale Blvd. Knightdale, NC 27545 USA 1-888-SquareD (1-888-778-2733) www.schneider-electric.us Altivar is a registered trademark of Schneider Electric. Other trademarks used herein are the property of their respective owners. Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. 30072-453-27 2009 Schneider Electric All Rights Reserved 11/2009