Tel: &

Similar documents
MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:

Current transformers. Current transformers

Basic Series Accessories Low Voltage Current Transformer Class 1

SPLIT-CORE DC CURRENT TRANSDUCER

DIN Rail Mounting Bracket

SIGMA SERIES DE METER

Wide-Vue Analog Panel Meters

Wide-Vue Analog Panel Meters

PLATINUM SERIES SWITCHBOARD METERS

Center Winder Specification

Super Calendar. Heated rolls

Super Calendar. Heated rolls

ANSI Switchboard Meters

SPAN CONTROLS. For Quality, Reliability And Service

212, 312 & 412 Vista Series Analog Panel Meter

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

1. Table of Contents T-LINE. Page. 1. Table for contents Description Current transformers type HF Product Overview 4

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS

Technical Data Sheet Sigma Series DE Meter

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Standard Program Technical Description

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

Smart Look Series Meter

212, 312 & 412 Vista Series Analog Panel Meter

Current Switches and Transducers

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Technical Data Sheet Sigma Series DS Meter

AC Wattmeters and VArmeters

MODEL 422 Submersible Pump Controller

Century Style Analog Panel Meters

Unit/Comments. %; Equal Output Loads %; Equal Output Loads Full Load

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Explosion Proof Drop Light - 12 Volt AC/DC Watt Incandescent - 25' Cord - Twist Lock Plug

Power Supplies. Series FLEX Power Supplies...P2 Technical Information & Dimensions (Online)...P5. ADEL Power Supplies

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

Applications DC Motors Stepping and Servos Solenoid Valves Relays Lamps and Signal Systems Input to On-Board Regulators Some Floppy Disc Drives.

Technical information

Before first operating the equipment read the whole of these instructions. Safety may be impaired if they are not followed.

DIN Panel Meters Long Scale

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS

Electro Controls. Current Switches / Sensors WattsIndustries.co.uk

PRODUCTS: POWER SUPPLY

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Thermal Circuit Breaker 3120-F...

Jtec 10kA Miniature Circuit Breaker

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

Metering Products Protection Units Current Transformers. April 1, 2015

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Technical Data Sheet Sigma Series DG Meter

Horizontal Circuit Switchers

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Horizontal Circuit Switchers

INSTRUCTIONS FOR USE

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

KM Metering Inc. Product Catalog Smart Meters. EKM-Omnimeter Pulse v.4. EKM-Omnimeter II UL v.3

Switching Power Supplies

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

Installation and Operation Instructions DLP Series

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER

65 Watt High Intensity LED Light - 120/277V AC ft Spot Beam - 6.7" OD Light Head

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Proportional Pressure Reducing Valve PDM08130

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Temperature controller. Side. Vac 3. Typically. Temperature controller. Side. Vac Driving SSR. Temperature controller. Resistor. Vac.

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

CONTINUITY TESTER FOR METALLIC & REMOTELY BONDED STRUCTURES

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

9 Watt High Output LED Light Emitter on Magnetic Base Goose-Neck Arm V

SPECIFICATION FSP350-60APN(85) Bronze. (Erp2013) DATE:MAY, 14, 2013 表單編號 :7000P Page1

Metering Products. Metering Products Protection Units April 1, Price List. Price List. With effect from April 1,

300 Watt LED Pole Top Light Fixture VAC W Metal Halide Equivalent - Slip Fit Yoke

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

SST-ST75F-ESS The essential silver standard

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Safety Lampholders and Pendants

ELECTRICAL PANELS. Chap.

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

Non-Spring Return EconoDrive Floating Actuator

ComfortPoint Programmable Lon, VAV/Unitary Controllers

PHOENIX CONTACT

Fire Rated Downlights Product Catalogue

750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R

LED Trouble Light / Hand Lamp / Drop Light -10 Watt LED Bulb - 12 Foot SJOW Cord

Spyder BACnet Programmable Controllers

DIGITAL EARTH LEAKAGE RELAY

A.C. 90 & 240º SCALE AMMETERS & VOLTMETERS

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Current transformers

Transcription:

C O N T R O L S BRITISH QUALITY COMPANY Split Core Current Transformers & Transducers Primary Currents from 50 to 5000 Amps Accuracy Class 1 & Class 0.5 1 Amp & 5 Amp Secondaries 0-333mV AC Transducer Output 4-20mA DC Transducer Output Choice of Aperture Sizes Click Shut & Easy Locking Protected Terminal Covers Integral Cable / Bus-Bar Pinch Screws Optional Mounting Feet Serving:- Water Industry Process Control BMS Transportation HVAC Energy Tel: 01276 25858 & 0161 62616

Moulded case split core current transformers, all with unique clip-together features enabling a quick installation with the minimum of disturbance into existing networks without the need to disconnect in situ cabling. + TECHNICAL SPECIFICATIONS Compliance: IEC/EN 60044-1, BS3938 marked: Yes Rated system voltage: Max 720V continuous Insulation: Max 3KV for 1 min Frequency range: 50-60Hz Material: Moulded case polycarbonate UL94V-0 Ambient temp range: o o -30 C to +80 C Max continuous current: 1.2 x rated current 1 + MAX CABLE SIZE mm DIA. + PRIMARIES FROM 100 AMPS TO 800 AMPS + MAX OVERALL 116x105mm + CLASS 1 (only) FOX.SC 100/5 1 1 FOX.SC 150/5 1 1.5 FOX.SC 200/5 1 2.5 FOX.SC 250/5 1 2.5 FOX.SC 300/5 1 2.5 FOX.SC 0/5 1 5 FOX.SC 500/5 1 5 FOX.SC 600/5 1 5 FOX.SC 800/5 1 5 FOX.SC 35 105 87 102 38 O 35 36 FOX.SC Maximum Width 116mm

2 + PRIMARIES FROM 100 AMPS TO 0 AMPS + MAX APERTURE SIZE 23x33mm + MAX OVERALL 93x106mm + CLASS 1 (class 0.5 on request, some ratios) FOX.SC23 100/5 1 1.5 FOX.SC23 150/5 1 1.75 FOX.SC23 200/5 1 2.5 FOX.SC23 250/5 1 3.75 FOX.SC23 300/5 1 5 FOX.SC23 0/5 1 6.25 23 33 103 1 Amp secondaries available to special order, along with Class 0.5 on some ratios, please consult our sales office. 93 + PRIMARIES FROM 250 AMPS TO 1000 AMPS + MAX APERTURE SIZE 82x52mm + MAX OVERALL 125x158mm + CLASS 1 (class 0.5 on request) FOX.SC23 & FOX.SC58 FOX.SC58 250/5 1 2.5 FOX.SC58 300/5 1 3.75 FOX.SC58 0/5 1 3.75 FOX.SC58 500/5 1 5 FOX.SC58 600/5 1 7.5 FOX.SC58 800/5 1 10 FOX.SC58 1000/5 1 15 1 Amp secondaries available to special order, along with Class 0.5 on some ratios, please consult our sales office. 52 82 125 158

+ PRIMARIES FROM 250 AMPS TO 3000 AMPS + MAX APERTURE SIZE 82x122mm + MAX OVERALL 155x198mm + CLASS 1 (class 0.5 on request) 3 FOX.SC812 250/5 1 2.5 FOX.SC812 300/5 1 3.75 FOX.SC812 0/5 1 3.75 FOX.SC812 500/5 1 5 FOX.SC812 600/5 1 7.5 FOX.SC812 800/5 1 10 FOX.SC812 1000/5 1 15 FOX.SC812 1200/5 1 30 FOX.SC812 1500/5 1 45 FOX.SC812 1600/5 1 45 FOX.SC812 2000/5 1 45 FOC.SC812 2500/5 1 45 FOX.SC812 3000/5 1 45 82 122 155 198 1 Amp secondaries available to special order, along with Class 0.5 on some ratios, please consult our sales office. + PRIMARIES FROM 1000 AMPS TO 5000 AMPS + MAX APERTURE SIZE 82x162mm + MAX OVERALL 195x245mm + CLASS 1 (class 0.5 on request) FOX.SC816 1000/5 1 20 FOX.SC816 1200/5 1 20 FOX.SC816 1500/5 1 30 FOX.SC816 1600/5 1 30 FOX.SC816 2000/5 1 30 FOX.SC816 2500/5 1 30 FOX.SC816 3000/5 1 45 FOX.SC816 00/5 1 45 FOX.SC816 5000/5 1 45 82 162 195 245 FOX.SC812 & FOX.SC816 1 Amp secondaries available to special order, along with Class 0.5 on some ratios, please consult our sales office.

18, 32 & 44mm ID SPLIT CORE CURRENT TRANSFORMERS & TRANSDURS 4 TYPES: FOX.SC18, FOX.SC32 & FOX.SC44 + 18mm,32mm & 44mm internal diameter + Integral ratchet style cable clamp + Click shut closing action + Primary currents 50 Amps to 1000 Amps + Accuracy Class 1 + 5 Amp, 1 Amp, 0-333mVAC, 4-20mA secondaries DESCRIPTION Very compact split core devices available as current transformers or as current sensors, ideal for retro fitting in tight for space, existing installations. Secondary outputs available are:- 5 Amp (certain ratios). 1 Amp (certain ratios). 0-333mVAC for use with energy meters such as the 333mVAC input ND range, applicable when CT s have to be mounted a distance away from the meters and the overall VA required using traditional 5 Amp or 1 amp secondary CT s is greater than the VA available from the CT, using 333mVAC alleviates this scenario. 4-20mA loop powered 24VDC, maximum loop impedance 300 Ohms. These devices feature an integral ratchet style cable fixing clamps, an easy click shut closing action and are supplied with 2.5 m of 0.75mm colour coded flying leads, 5 Amp secondary units have 0.5 m of 1.5mm of flying leads. FOX.SC18, FOX.SC32 & FOX.SC44 SPECIFICATIONS General Continuous over current: Max short time current: Max system voltage: Isolation test voltage: Isolation class: Operating temperature: Standards: marked: Max. OD A B C 1.2 x In 60 x In 1sec 720V 50-60Hz 3KV 50Hz 1min E -5 C to +50 C DIN EN60044/1 VDE 0414/1 Yes E F 4-20mA output Output: 4-20mA loop powered Loop voltage: 24VDC +/-15% Power consumption: 1W max Max loop impedance: 300 Ohms Max output on overload: 30mA Response time: <300mSec PART No A B C D E F FOX.SC18 41.6 23 64.5 18.5 55 67.3 FOX.SC32 59.2 28.5 96.4 32.5 75 89.2 FOX.SC44 72.2 34.5 120.6 44 85 98.1

P/No. INTERNAL CASE OUTPUT CLASS VA DIAMETER SIZE FOX.SC18 200/1 18mm 1 1 Amp 1 1 FOX.SC18 250/1 18mm 1 1 Amp 1 1.5 FOX.SC18 50/333mVAC 18mm 1 333mVAC 1 N/A FOX.SC18 75/333mVAC 18mm 1 333mVAC 1 N/A FOX.SC18 100/333mVAC 18mm 1 333mVAC 1 N/A FOX.SC18 125/333mVAC 18mm 1 333mVAC 1 N/A FOX.SC18 150/333mVAC 18mm 1 333mVAC 1 N/A FOX.SC18 200/333mVAC 18mm 1 333mVAC 1 N/A FOX.SC18 250/333mVAC 18mm 1 333mVAC 1 N/A 5 FOX.SC32 300/5 32mm 2 5 Amp 1 2.5 FOX.SC32 0/5 32mm 2 5 Amp 1 5 FOX.SC32 500/5 32mm 2 5 Amp 1 5 FOX.SC32 600/5 32mm 2 5 Amp 1 5 FOX.SC32 300/1 32mm 2 1 Amp 1 FOX.SC32 0/1 32mm 2 1 Amp 1 5 FOX.SC32 500/1 32mm 2 1 Amp 1 5 FOX.SC32 600/1 32mm 2 1 Amp 1 5 FOX.SC32 100/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 150/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 200/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 250/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 300/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 0/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 500/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 600/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 100/4-20mA 32mm 2 4-20mA 1 N/A FOX.SC32 150/4-20mA 32mm 2 4-20mA 1 N/A FOX.SC32 200/4-20mA 32mm 2 4-20mA 1 N/A FOX.SC32 250/4-20mA 32mm 2 4-20mA 1 N/A FOX.SC32 300/4-20mA 32mm 2 4-20mA 1 N/A FOX.SC32 0/4-20mA 32mm 2 4-20mA 1 N/A FOX.SC32 500/4-20mA 32mm 2 4-20mA 1 N/A FOX.SC32 600/4-20mA 32mm 2 4-20mA 1 N/A FOX.SC44 250/5 44mm 3 5 Amp 1 1.5 FOX.SC44 300/5 44mm 3 5 Amp 1 2.5 FOX.SC44 0/5 44mm 3 5 Amp 1 5 FOX.SC44 500/5 44mm 3 5 Amp 1 5 FOX.SC44 600/5 44mm 3 5 Amp 1 5 FOX.SC44 800/5 44mm 3 5 Amp 1 5 FOX.SC44 1000/5 44mm 3 5 Amp 1 5 FOX.SC44 250/1 44mm 3 1 Amp 1 2.5 FOX.SC44 300/1 44mm 3 1 Amp 1 2.5 FOX.SC44 0/1 44mm 3 1 Amp 1 5 FOX.SC44 500/1 44mm 3 1 Amp 1 5 FOX.SC44 600/1 44mm 3 1 Amp 1 5 FOX.SC44 800/1 44mm 3 1 Amp 1 5 FOX.SC44 1000/1 44mm 3 1 Amp 1 5 FOX.SC44 250/333mVAC 44mm 3 333mVAC 1 N/A FOX.SC44 300/333mVAC 44mm 3 333mVAC 1 N/A FOX.SC44 0/333mVAC 44mm 3 333mVAC 1 N/A FOX.SC44 500/333mVAC 44mm 3 333mVAC 1 N/A FOX.SC44 600/333mVAC 44mm 3 333mVAC 1 N/A FOX.SC44 800/333mVAC 44mm 3 333mVAC 1 N/A FOX.SC44 1000/333mVAC 44mm 3 333mVAC 1 N/A FOX.SC44 0/4-20mA 44mm 3 4-20mA 1 N/A FOX.SC44 300/4-20mA 44mm 3 4-20mA 1 N/A FOX.SC44 250/4-20mA 44mm 3 4-20mA 1 N/A FOX.SC44 500/4-20mA 44mm 3 4-20mA 1 N/A FOX.SC44 600/4-20mA 44mm 3 4-20mA 1 N/A FOX.SC44 800/4-20mA 44mm 3 4-20mA 1 N/A FOX.SC44 1000/4-20mA 44mm 3 4-20mA 1 N/A SPECIFICATION

C O N T R O L S NORTONICS FOXTAM LIMITED HEAD OFFI: Bridge Road, Camberley, Surrey GU15 2QR Tel: +44 (01276) 25858 Fax: +44 (01276) 25885 MANUFACTURING: Foxtam House, Watts Street, Chadderton, Oldham, Lancs Ol9 9LQ Tel: +44 (0161) 626 16 Fax: +44 (0161) 627 0929 e-mail: sales@nortonicsfoxtam.co.uk www.nortonicsfoxtam.co.uk Tel: 01276 25858 & 0161 62616 2013 Edition