Series AV2000/3000/4000/5000

Similar documents
Soft Start-up Valve. AV2000/3000/4000/5000 Series

AV2000-A/3000-A/4000-A/5000-A

Two Hand Control Valve

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Soft Start-up Valve AV2000/3000/4000/5000

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

NAMUR Interface 5 Port Solenoid Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Precision Clean Regulator

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

High Pressure Coolant Valve

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model

Standard Specifications

Coolant valve. SGC/SGH Series

How to Order. Nozzle. Nil Connection size N02 N03 F02 F H06 H08 H10 H07 H09 H11

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Air Filter. Best Pneumatics 4. Equipment. Air Line

Series VP3145/3165/3185

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121

Standard Specifications

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products.

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

0.35 W (Without light)

Process Valve/Series VN

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Pressure Relief 3 Port Valve With Locking Holes

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.

Rubber Seal VP300/500/700

Pressure Control Equipment

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

AV2000/3000/4000/5000

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

1.0 cm 3 /min. Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS22/23. Compact and Lightweight mm.

5 Port Solenoid Valve

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

Series VP3145/3165/3185

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Regulator Valve. VEX1 Series

Rotary Actuators Precautions 1 Be sure to read this before handling.

Doc. No.VT307 -OMH0001-C. 3 Port Direct Operated Solenoid Valve PRODUCT NAME. VT307 Series MODEL/ Series

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Coolant Valve. Air Operated/External Pilot Solenoid

Vacuum / Release Unit

Exclusively for air pressure system and air-hydro circuit control

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

Compact / Lightweight 2 Port Solenoid Valve

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Speed Controller with One-touch Fitting

Vacuum pump system type

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

Direct Operated 3-port solenoid valve

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

Specifications. Fluid Ambient and fluid temperature ( C)

Pilot Operated 2 Port Solenoid Valve for Dry Air

Speed Controller with One-touch Fitting

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

3 Port Solenoid Valve

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range

Doc. No.VQ4000V-OMV0001. Solenoid Valve PRODUCT NAME. VQ4000/5000 (Pilot Valve V100) MODEL/ Series

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Transmitters: Relay Valve VR4151/4152

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Pilot Operated 2 Port Solenoid Valve for Dry Air

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

CAT.ES70-22 A. Series VC. Direct Operated 2 Port Solenoid Valve for Heated Water. Series VCB

Check Valve Series AK How to Order

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC.

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ

3 Port Solenoid Valve Direct Operated Poppet Type

Compact Proportional Solenoid Valve

Transcription:

Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU AF AR IR VEX SRP AW AMR AWM AWD ITV VA AL Large effective area (mm²) AV/ (ody size: /4) AV3/ 37 (ody size: 3/8) AV4/ 6 (ody size: /) /3 (ody size: 3/4) / (ody size: ) Manual supply/exhaust function Low power consumption Modular with F.R.L. combinations F.R.L. combinations F.R.L. combination Soft start-up valve AV AV3 AV4 Except AC4-6 AC AC5 AC3 AC4 AC5 AC6 SMC F.R.L. combination Soft start-up valve.-

Soft Start-up Valve AV/3/4/5 How to Order E AV F C Q Ordering source area code E N Japan, Asia, Australia Europe North Ameria Soft start-up valve Manual override : Non-locking push type (flush type) : Locking type (tool required) C: Locking type (lever type) 3 4 5 ody size /4 3/8 / 3/4, Thread type 3 4 6 F N Rc NPT Port size /4 (AV only) 3/8 (AV3 only) / (AV4 only) 3/4 ( only) ( only) Option None With pressure gauge Order Made Rated coil voltage * * 3* 4* 5 6 9 Indicator light/surge voltage suppressor S Z VAC (5/6Hz) VAC (5/6Hz) to VAC (5/6Hz) VAC (5/6Hz) 4VDC VDC Other * DIN type only. Contact SMC for other voltages (9). None With surge voltage suppressor (grommet type only) With indicator light/surge voltage suppressor (not possible with grommet type) Electrical entry : rommet (only DC voltage) D: Type D DIN terminal How to Order Pilot Valve Assemblies SF4 8 Q Y: Type Y DIN terminal Rated coil voltage * VAC (5/6Hz) * VAC (5/6Hz) 3* to VAC (5/6Hz) 4* VAC (5/6Hz) 5 4VDC 6 VDC 9 Other *DIN Type only Electrical entry D Y rommet Type D DIN terminal Type Y DIN terminal For soft start-up valve Indicator light Surge voltage suppressor S Z Manual override C Non-locking push type (flush type) Locking type (tool required) Locking type (lever type) None With surge voltage suppressor (grommet type only) With indicator light/surge voltage suppressor (not possible with grommet type) TÜV Rheinland AUART EPRÜFT TYPE APPROVED Note) The grommet type can have a surge voltage suppressor (direct coupling type lead wire), but without indicator light. TÜV approved product Conforms to standards necessary to satisfy EC directives. Series AV has received approval from TÜV Rheinland, an EC Notified ody (EC authorization number 97), for conformity to DIN VDE58: 994 Standards. Consult SMC for details when ordering TÜV approved products because of restrictions regarding product model, voltage specification, and electrical entry, etc..-

Soft Start-up Valve AV/3/4/5 Specifications Type D DIN terminal Type Y DIN terminal Model Port size Proof pressure Operating pressure range Pressure gauge port size Ambient and fluid temperature Effective area (A) (mm²) (A) Weight (kg) Rated coil voltage Allowable voltage fluctuation Coil insulation type Apparent power Inrush (current AC consumption) Energized Electrical specifications Current consumption DC Electrical entry Optional specification Pilot valve manual override Secondary pressure MPa AV /4 AV3 3/8 AV4 / 3/4 37 6 3 4 49 76 3 4.7.48.74.6.54,, to, VAC (5/6Hz),, 4VDC 5% to +% of rated voltage Equivalent to type (3 C) 5.6VA (5Hz), 5.VA (6Hz) 3.4VA (.W)/5Hz,.3VA (.5W)/6Hz.8W rommet, Type D DIN terminal, Type Y DIN terminal Indicator light/surge voltage suppressor Note ) Non-locking push type (flush type), Locking type (tool required), Locking type (lever type) Piston switching pressure (Open Closed).5.4.3...5MPa. to MPa /8 to 6 C Note ) Note ) Use dry air when operating at a low temperature. Note ) The grommet type can have a surge voltage suppressor (direct coupling type lead wire), but without indicator light. AC AV AU AF AR IR VEX SRP AW AMR AWM AWD ITV VA AL...3.4.5.6.7.8.9. Primary pressure MPa Symbol Accessories/Pressure gauge Description Part no. Pressure range (A) Pressure gauge 36-- MPa Needle valve flow characteristics Air flow l/min (ANR) 8 6 4 8 6 4 Conditions: Primary pressure.5mpa AV4 AV3 AV 3 4 5 Needle rotations.-3

AV/3/4/5 Working Principle ON - (A) Working condition Low speed supply High speed supply Normal operation Pressure Pilot valve conditions Working description When pilot valve is turned ON by energization or manual override, the pilot air pushes piston A and main valve downward and opens main valve while / PP > R port closes simultaneously. The air from PA P port moves to needle valve, where its flow is adjusted, and flows to A port. The meter-in control of needle valve slowly moves the cylinder from A to. ON When / PP PA after the cylinder reaches, piston fully opens and PA increases rapidly as shown from C to D and / PP PA becomes the same pressure as PP. / PP = approx. PA Pressure time chart (meter-out control) example Initial operation return stroke Pressure stroke A PP PA Cylinder movement with fixed orifice Time C D PR (atmospheric pressure) Since piston holds the fully open condition, during normal operation the cylinder's speed will be controlled by the usual meter-out control. Cylinder drive circuit (meter-out control) example PP PP PA (A) PA (A) Quick exhaust When pilot valve is turned, spring pushes piston A and main valve upward and opens R port while shutting off the air supply from P port. The pressure difference generated at this time opens check valve and the residual pressure on the A port side is quickly exhausted from R port. PP PA (A).-4

Soft Start-up Valve AV/3/4/5 Construction AC AV ON - AU AF (A) AR IR VEX SRP AW AMR Parts list No. 3 Description ody Cap Cover Material ADC ADC ADC AWM AWD ITV VA Replacement parts No. 4 5 6 7 8 9 3 4 5 6 7 8 9 Description Pilot valve assembly Piston A assembly Piston assembly Main valve assembly Check valve Piston guide assembly Needle assembly Valve spring Piston spring Check spring Needle spring C type snap ring for shaft C type snap ring for hole Seal Seal O-ring Material POM, NR rass, NR (HNR) rass, NR (HNR) rass, NR (HNR) POM, NR rass, NR Steel wire Stainless steel Stainless steel Steel wire Tool steel Tool steel NR NR NR AV P444A P445A P446A P447 P448A P449A P44 P44 P443 P444-5 -9 P44 P448 x 8 x Part no. AV3 AV4 SF4- -8 P4434A P4444A P4435A P4445A P4436A P4446A P4437 P4447 P4438A P4448A P4439A P4449A P443 P444 P443 P444 P4433 P4443 P4434 P4444 STW-5 STW-8 - RTW- P443 P444 P4435 P4445 x 9 x.5 x 9.5 x.5 P4454A P4455A P4456A P4457 P4458A P4459A P445 P445 P4453 STW- RTW-5 P445 P4454 6.5 x.5 x AL Refer to page.- for pilot valve assembly part number designations..-5

AV/3/4/5 Dimensions rommet: AV - -, S D DIN terminal: AV - - D, DZ DIN terminal for European use: AV - - Y, YZ D I - A + SMC MADE IN JAPAN 3mm (lead wire length) Manual override (locking lever type) Applicable heavy duty cord O.D.: ø6, ø8 With indicator light/ surge voltage suppressor Manual override (locking lever type) - + SMC L K A MADE IN JAPAN M Port size ON Pressure gauge mounting bore /8 ø37 P A H Q C N ø37 P ON A Indicator light Q H 36.8 E R P 4-R 36.8 E Pressure gauge mounting bore /8 R P 4-R C Model Port size A C D E H I K L M N P Q R AV- - AV- - S AV- - D AV- - DZ AV- - Y AV- - YZ AV3-3- AV3-3- S AV3-3- D AV3-3- DZ AV3-3- Y AV3-3- YZ AV4-4- AV4-4- S AV4-4- D AV4-4- DZ AV4-4- Y AV4-4- YZ 6 - - 6 - - S 6 - - D 6 - - DZ 6 - - Y 6 - - YZ /4 /4 /4 3/8 3/8 3/8 / / / 3/4, 3/4, 3/4, 66 66 66 76 76 76 98 98 98 8 8 8 5 5 5 3 3 7 47 47 55 75 75 3 3 3 36 36 36 47 47 47 59 59 59 4 4 4 3 3 3 39 39 39 4 4 4 48 48 48 5 5 5 74 74 74 38 38 38 43 43 43 57 57 57 77 77 77 3 3 3 47.5 5.5 6.5 74 65.5 67.5 68.5 7.5 8.5 8.5 9 94 8.5 84.5 85.5 87.5 97.5 99.5 7 6 3.5 7.5 6 3.5.5 6.5 93 5 43 9 9 9 8 8 8 4 4 4 5 5 5 3.5 3.5 3.5 7.5 7.5 7.5 37 37 37 46 46 46 M4 Depth 4.5 M4 x.7 Depth 4.5 M4 Depth 4.5 M5 Depth 5 M5 Depth 5 M5 Depth 5 Depth 6 Depth 6 Depth 6 Depth 7.5 Depth 7.5 Depth 7.5.-6

ON Soft Start-up Valve AV/3/4/5 Modular F.R.L. Combination Spacer Select one of the spacers below when connecting to an F.R.L. combination unit (AC to AC6). (Spacers must be ordered separately.) AC IN SMC OUT AV 7 R AU AF AR IR Spacer L type bracket Spacer with L type bracket T type bracket Spacer with T type bracket VEX SRP AW AMR AWM AWD Spacer with L type bracket ITV VA L type bracket Spacer with T type bracket T type bracket Model Y Applicable model AV L type bracket L Spacer with L type bracket YL Applicable model AV T type bracket T Spacer with T type bracket YT Applicable model AV AL Y3 AV3 3L Y3L AV3 3T Y3T AV3 Y4 AV4 4L Y4L AV4 4T Y4T AV4 Y6 6L Y6L 6T Y6T.-7

AV/3/4/5 Specific Product Precautions e sure to read before handling. Design. Actuator drive When a component such as a solenoid valve or actuator is to be driven using this product, take appropriate measures to prevent potential danger caused by actuator operation.. Holding of pressure Since the products are subject to air leakage (allowed), they cannot be used for applications such as holding pressure in a pressure vessel. 3. Maintenance space The installation should allow sufficient space for maintenance activities. Selection. Confirm the specifications. The products presented in this catalogue are designed only for use in compressed air systems. Do not operate at pressures or temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. (Refer to specifications.) Contact SMC when using a fluid other than compressed air.. Extended periods of continuous energization Contact SMC if valves will be continuously energized for extended periods of time. 3. Operation of closed centre solenoid valves When closed center solenoid valves are used, or when used on an actuator with a load factor of 5% or more, jumping (lurching) cannot be prevented even if this product is used. 4. Using a regulator on the secondary side When mounting a regulator on the secondary side (A port side), use a residual pressure relief regulator (AR55 to 45) or a check type regulator (AR56 to 66). With a standard regulator (AR to 6), the secondary side pressure may not be released when this valve is exhausted. 5. Operation of secondary side solenoid valves To operate solenoid valves mounted on this product s secondary side (A port side), first confirm that the secondary side s pressure (P) has increased to become equal to the primary side s pressure (P). 6. Operation The residual pressure release function of this product is for emergency use only; therefore, avoid operation in the same manner as ordinary 3 port valves. 7. Using a lubricator If mounting a lubricator, mount it on the primary side (P port side), of this product. If mounted on the secondary side (A port side), back flow of oil will occur and may spurt out of the valve s R port. 8. Operation for air blowing This product cannot be operated for air blowing due to the mechanism that switches the main valve to be fully open after the secondary side s pressure increases to approximately / of the primary side. Selection. Leakage voltage Particularly when using a C-R element (surge voltage suppressor) for protection of the switching element, take note that leakage voltage will increase due to leakage current flowing through the C-R element, etc. Power supply Switching element Resistor Leakage current AC coil is % or less of rated voltage. DC coil is 3% or less of rated voltage. Valve. Low temperature operation Although the valve can be operated at a temperature as low as C, measures should be taken to avoid solidification or freezing of drainage and moisture, etc. Mounting. If air leakage increases or equipment does not operate properly, stop operation. After mounting or maintenance, etc., connect the compressed air and power supplies, and perform appropriate function and leakage tests to confirm that the unit is mounted properly.. Instruction manual Mount and operate the product after reading the manual carefully and understanding its contents. Also keep the manual where it can be referred to as necessary. 3. Painting and coating s or specifications printed or pasted on the product should not be erased, removed or covered up. Furthermore, contact SMC before painting resin parts, as this may cause adverse effects depending on the solvent. Leakage voltage Adjustment. To perform the initial speed adjustment of a secondary side actuator, supply air from this valve's primary side and turn ON the pilot valve. Then, rotate the needle counter clockwise from the fully closed condition..-8

AV/3/4/5 Specific Product Precautions e sure to read before handling. Piping. Preparation before piping efore piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe.. Wrapping of pipe tape When connecting pipes and fittings, etc., be sure that chips from the pipe threads and sealing material do not get inside the valve. Further, when pipe tape is used, leave.5 to thread ridges exposed at the end of the threads. 3. Tighten threads with the proper tightening torque. When screwing fittings into valves, tighten with the torques given below. Tightening torque for piping Connection threads Rc /4 Rc 3/8 Rc / Rc 3/4 Rc Winding direction Expose approx. threads Pipe tape Proper tightening torque N m to 4 to 4 8 to 3 8 to 3 36 to 38 4. Connection of piping to products When connecting piping to a product, refer to its instruction manual to avoid mistakes regarding the supply port, etc. 5. F.R.L. module combination When connecting to a modular F.R.L. combination (AC to 6), select one of the spacers, which are included. (Refer to page 6 for details.) However, modular combination with AC4-6 is not possible. Furthermore, connect soft start-up valves to the secondary side of the F.R.L. combination. 6. Primary side piping conditions The nominal size of the piping material's or equipment's bore should be equal to or larger than the soft start-up valve's port size. The composite effective area of the primary side's (P port side's) piping or equipment should be equal to or larger than the values below. Indicator Light/Surge Voltage Suppressor Voltage AC and VDC 4VDC or less Electrical circuit Terminal no. (+) Terminal DIN terminal ZNR With indicator light Terminal no. ( ) Electrical Connection DIN terminal Lubrication. The valve has been lubricated for life at the factory, and does not require any further lubrication.. In the event that it is lubricated, use Class turbine oil (without additives), ISO V3. However, once lubrication is applied it must be continued, as the original lubricant may be eliminated leading to malfunction. Contact SMC regarding Class turbine oil (with additives), ISO V3. + Terminal no. + ( ) +( ) (+) ZNR With indicator light Terminal no. (+) Note) There is no polarity (+ or ). The internal connection of the DIN terminal is as shown below, therefore, connect to the power supply side as shown. AC AV AU AF AR IR VEX SRP AW AMR AWM AWD ITV VA AL Model AV AV3 AV4 Composite effective area mm² 5 35 5 When the piping is restricted or the supply pressure is insufficient, the main valve will not switch and air leakage may occur from the R port..-9

AV/3/4/5 Specific Product Precautions 3 e sure to read before handling. Air Supply. Use clean air. Do not use compressed air which contains chemicals, synthetic oils containing organic solvents, salts or corrosive gases, etc., as this can cause damage or malfunction.. Install air filters. Install air filters close to valves at their upstream side. A filtration degree of 5µm or less should be selected.. Install an after-cooler, air dryer or water separator, etc. Air that includes excessive drainage may cause malfunction of valves and other pneumatic equipment. To prevent this, install an after-cooler, air dryer or water separator, etc. Operating Environment. Do not use valves in atmospheres of corrosive gases, chemicals, salt water, water or steam, or where there is direct contact with any of these.. Do not use in an explosive atmosphere. 3. Do not use in locations subject to vibration or impact. 4. A protective cover, etc., should be used to shield valves from direct sunlight. 5. Shield valves from radiated heat generated by nearby heat sources. 6. Employ suitable protective measures in locations where there is contact with water droplets, oil or welding spatter, etc. 7. In a dusty environment or when valve switching noise is intrusive, take measures for the prevention of dust entry and for noise reduction, such as mounting a silencer on the R port. Maintenance. Perform maintenance procedures as shown in the instruction manual. If handled improperly, malfunction or damage of machinery or equipment may occur.. Equipment removal and supply/exhaust of compressed air When equipment is removed, first confirm that measures are in place to prevent dropping of work pieces and run-away of equipment, etc. Then cut the supply pressure and power, and exhaust all compressed air from the system using its residual pressure release function. 3. Low frequency operation Valves should be switched at least once every 3 days to prevent malfunction. (Use caution regarding the air supply.) 4. Manual override operation When the manual override is operated, connected equipment will be actuated. Confirm safety before operating.. Drainage removal Remove drainage from air filters regularly. (Refer to specifications.) How to Find the Flow Rate (at air temperature of C) Choke flow: when (P +.)/(P +.).5 Q = x S x (P +.) x 93 73 + t Subsonic flow: when (P +.)/(P +.) >.5 Q = 4 x S x (P P)(P +.) x 93 73 + t Q : Air flow rate [l/min (ANR)] S : Effective area (mm²) P: Upstream pressure [MPa] P: Downstream pressure [MPa] t : Air temperature Note) Formulas above apply to compressed air only. Use conventional formulas for water and steam..-