RX 3 M.C.B A up to 63 A

Similar documents
RX 3 M.C.B A up to 63 A

up to 63 A (1 module per pole)

(1,5 modules per pole)

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Phase + Neutral, neutral on right side

DX³ 4-pole RCBO 6000 A/10 ka

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCCBs - ID 4P up to 100 A

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DX³ RCBO 6000 A Phase + Neutral, neutral right side

TX³ RCCBs 2P up to 100 A

DX³ RCBO 6000A Phase + Neutral, neutral on left

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

DX³ RCBO 6000A Phase + Neutral, neutral on right

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Btdin RCBO 6000A up to 63A (2P)

R.C.B.O. SP / 1 module

Cat N 3. OVERALL DIMENSIONS

Industrial Contactors CTX 3 3P 185A - 800A

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

DRX 125 Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable)

Thermal-magnetic Miniature Circuit Breaker 4230-T...

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

cor Long Run Experience

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Magnetic only

Low Voltage A GE Power Controls Company. General catalogue

NB1 Miniature Circuit Breaker

AF40... AF96 3-pole contactors Technical data

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Thermal-magnetic Miniature Circuit Breaker 4230-T...

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

DPX earth leakage DPX 3 -I earth leakage

Electronic circuit breaker EBU10-T

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

ZS4-SF1 Screw Clamp Terminal Block

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

MS General Information Extended Product Type: MS

COMPLETE SOLUTIONS FOR POWER PROTECTION

The new SH200 MCBs can be used in domestic, commercial and industrial applications for protection against over-current and short circuit.

C60H-DC C curve. Catalogue numbers

Viking 3 - Screw connection Disconnect terminal blocks

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Protection components

Essential equipment for all your requirements

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

3 - Protection components Motor circuit-breakers

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Modular contactors and relays

New DX 3 High rating & breaking capacity

Breaking and protection devices

ic60a circuit breakers (curve C)

ABB STOTZ-KONTAKT GmbH

DPX moulded case circuit breakers

DMX 3 -I 2500 switch disconnectors

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

GE Consumer & Industrial Power Protection. New. ElfaPlus Unibis. Compact MCB s. Saving up to 50% space in distribution boards. GE imagination at work

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

ZS50-PE Screw Clamp Terminal Blocks Ground

DPX 1600 Electronic release

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

DPX Electronic + earth leakage

and other modular devices for low voltage installation

DPX 630 Electronic release

K50H004UP cam changeover switch - 4-pole A - screw mounting

ZS35 Screw Clamp Terminal Blocks Feed-through

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

K30H001YP cam star-delta switch - 3-pole A - screw mounting

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections

Thermal magnetic and trip-free switches

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

Transcription:

87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection... 1 5. General characteristics... 2 6. Compliance and and approvals... 5 7. Equipments and accessories... 5 1. DESCRIPTION - USE:. Thermal-magnetic circuit breaker (MCB) with positive contact indication for control, protection against short-circuits and overloads, and isolation of electrical circuits. 3 OVERALL DIMIENSIONS Symbol : Technology:. Limiting device 2. RANGE Rated currents, In:. Curve B 6 / 10 / 13 / 16 / 20 / 25 / 32 / 40 / 50 / 63 A. Curve C 6 / 10 / 13 / 16 / 20 / 25 / 32 / 40 / 50 / 63 A Polarity:. 1P, 2P, 3P Width:. 1 module per pole. Each pole is 17,7 mm Magnetic tripping curves :. B curve (between 3 and 5 In). C curve (between 5 and 10 In) Thermal threshold according to IEC/EN 60898-1:. Non operating current (Inf): 1.13 In.. Operating current (If): 1.45 In. 1P 2P 3P X 17.7 mm 35.4 mm 53.1 mm Rated voltage / frequency:. 230 V ~ / 400 V ~ - 50 / 60 Hz with standard tolerances Maximum operating voltage:. 1P 230 V ~ ± 10%. 2P, 3P 400 V ~ ± 10% Breaking capacity:. 6000 A in accordance with standard EN/IEC 60898-1 4. PREPARATION - CONNECTION Fixing:. On symmetrical rail EN/IEC 60715 or DIN 35 rail. Operating positions:.vertical Horizontal Upside down On the side 1 / 5

4. PREPARATION - CONNECTION (continued) Power supply:. From the top or the bottom. Connection:. Inputs and outputs via screw terminals. Cage terminals, with release and captive screws. The location of the terminals allows supplying by pin busbar both sides and fork busbar lower side r. 4. PREPARATION - CONNECTION (continued) Contact status display:. By front face marking: - "O-OFF" = contacts open - "I-ON" = contacts closed Sealing:. Possible in ʺOpenʺ position (OFF) or ʺCloseʺ position (ON). Locking:. By 5 mm padlock (cat. N 4 063 13) or 6 mm padlock (cat. N 0 227 97) with padlock support (cat. N 4 063 03). 5. GENERAL CHARACTERISTICS Marking on the front side:. By permanent ink pad printing: - Trade name: RX 3 - Breaking curve - Rated current (in A) - Contact status. - Icn in A rated breaking capacity in accordance with IEC/EN 60898-1 (in a box) - Limiting class 3 (in a square) - Mark: Legrand. Terminal depth :. 14 mm Stripping length recommended:. 11 mm Screw head:. Mixed, slotted and Pozidriv 2. Top face marking:. By permanent pad printing - Rated voltage(s), Certification logo and Electric diagram Tightening torque:. Recommended: 2.5 Nm.. Mini: 2 Nm. Maxi: 3 Nm. Tools required:. For the terminals: Pozidriv n 2 or flat screwdriver 5.5 mm (6 mm maximum).. For fixing: flat screwdriver 5.5 mm (6 mm maximum). Side face marking:. By laser marking: - Copy-tracer and production information Connectable section: Copper cables Rigid cable Flexible cable Without ferrule 1 x 1.5 mm² to 25 mm² 2 x 1.5 mm² to 10 mm² 1 x 1.5 mm² to 16 mm² 2 x 1.5 mm² to 10 mm² With ferrule - 1 x 1.5 mm² to 16 mm² Manual actuation of the MCB:. Ergonomic 2-position handle: ON and OFF 2 / 5

5. GENERAL CHARACTERISTICS (continued) Short-circuit breaking capacity:. Alternate current 50/60Hz, single-phase or three-phase network, in accordance with standard: EN/IEC 60898-1 Un 1P 2P 3P 10000 A 16000 A - 230V~ Icn 6000 A 10000 A 10000 A 400V~ - 6000 A 6000 A 230V~ 400V~ Ics 75% of Icn 75% of Icn 75% of Icn. Alternate current 50/60Hz, single-phase or three-phase network, in accordance with standard: EN/IEC 60947-2 Un 1P 2P 3P 10 ka 16 ka - 230V~ Icu 6 ka 10 ka 10 ka 400V~ - 6 ka 6 ka 230V~ 400V~ Ics 75% of Icu 75% of Icu 75% of Icu Short-circuit breaking capacity of only one pole:. Icn1 = 6 ka at 230 V, where Icn1 is the breaking capacity of one pole for multi-pole MCB s in case of short-circuit to earth.. Breaking capacity of one single pole under 400 V compound voltage (IT network) = 1.5kA.. Breaking capacity of one single pole under 230 V compound voltage (IT network) = 6 KA. Minimum operating voltage:. 12 V a.c. / d.c. per pole. Pulse rated voltage:. Uimp = 4 kv Insulation rated voltage:. Ui = 500 V Pollution degree :. 2 in accordance with standard EN/IEC 60898-1. Electric strength:. 2500 V Operation at 400 Hz:. The magnetic thresholds increase by 45%. Load to close and to open a pole trough the handle:. 0.1 Nm per pole to close.. 0.075 Nm per pole to open. Isolating distance (distance between contacts):. more than 5 mm with the handle in open position O 5. GENERAL CHARACTERISTICS (continued) Mechanical endurance:. 20000 operations without load.. 10000 operations with load (under In*cos = 0.9). Enclosure material:. Polyester.. Characteristics of this material: self extinguishing, heat and fire resistant according to EN 60898-1, glow-wire test at 960 C for external parts made of insulating material necessary to retain in position current-carrying parts and parts of protective circuit (650 C for all other external parts made of insulating material). Average weight per pole:. 0.130 kg. Volume when packed: Volume (dm 3 ) 1P (packed per 12) 2.0 2P (packed per 6) 2.0 3P (packed per 4) 2.0 Ambient temperatures:. Operation: from 25 to + 70. Storage: from 40 to + 70 Degree or class of protection:. Protection index the screw head against solid and liquid bodies: IP 20, (in accordance with standards IEC 529, EN 60529 and NF C 20-010).. Protection index of the box against solid and liquid bodies: IP 40 (in accordance with standards IEC 529, EN 60529 and NF C 20-010).. Protection index against mechanical shocks: IK 02 (in accordance with standards EN 50102 and NF C 20-015). Dissipated power in case of fire:. available on request with required Standard Sinusoidal vibration resistance in accordance with IEC 60068.2.6:. Axis: x, y, z.. Frequency range: 5 100 Hz ; duration 90 minutes. Displacement (5 13,2 Hz) : 1mm. Acceleration (13,2 100 Hz) : 0,7 (g=9,81 m/s 2 ) Power dissipated per pole (W) :. Circuit breaker B and C curves In 6 A 10 A 13 A 16 A 20 A 1P 4P 1.1 1.8 2 2.2 2.4 In 25 A 32 A 40 A 50A 63A 1P 4P 3.0 3.2 4 4.5 5.5. Impedance per pole (Ω) = P dissipated In 2 3 / 5

5. GENERAL CHARACTERISTICS (continued): Derating of circuit-breakers according to ambient temperature :. The rated characteristics of a circuit breaker are modified according to the ambient temperature inside the cabinet or the enclosure where the circuit breaker is located.. Reference temperature: 30 C in accordance with EN/IEC 60898-1 Ambient Temperature / In In (A) - 25 C - 10 C 0 C 10 C 20 C 30 C 40 C 50 C 60 C 70 C 6 7.5 7.0 6.6 6.4 6.2 6.0 5.8 5.6 5.4 5.3 10 12.5 11.5 11.1 10.7 10.3 10.0 9.7 9.3 9.0 8.7 13 16.3 15.2 14.6 14.1 13.5 13 12.5 11.9 11.5 11.0 16 20.0 18.7 18.0 17.3 16.6 16.0 15.4 14.7 14.1 13.5 20 25.0 23.2 22.4 21.6 20.8 20.0 19.2 18.4 17.6 16.8 25 31.5 29.5 28.3 27.2 26.0 25.0 24.0 22.7 21.7 20.7 30 38.3 36.0 34.5 33.0 31.5 30.0 28.8 27.3 26.1 24.9 32 41.0 37.8 36.5 34.9 33.3 32.0 30.7 29.1 27.8 26.5 40 51.0 48.0 46.0 44.0 42.0 40.0 38.0 36.0 34.0 32.0 50 64.0 60.0 57.5 55.0 52.5 50.0 47.5 45.0 42.5 40.0 63 80.6 75.6 72.5 69.9 66.1 63.0 59.8 56.1 52.9 49.7 Derating of MCB for use with fluorescent lights: Ferromagnetic and electronic ballasts have a high inrush current for a short time. These currents can cause the tripping of circuit breakers. At the time of the installation, it should take into account the maximum number of ballasts per circuit breaker that the manufacturers of lamps and ballasts indicate in their catalogues. Influence of the altitude: 2000 m 3000 m 4000 m 5000 m Dielectric holding 3000 V 2500 V 2000 V 1500 V Max operational Voltage 400 V 400 V 400 V 400 V Derating at 30 C none none none none Derating of MCBs function of the number of devices side by side: When several MCBs are juxtaposed and operate simultaneously, the thermal evacuation of the poles is limited. This results in an increase in operating temperature of the circuit breakers which can cause unwanted tripping. It is recommended to apply the following coefficients to the rated currents. Number of circuit breakers side by side Coefficient 2-3 0.9 4 5 0.8 6-9 0.7 10 0.6 These values are given by the recommendation of IEC 61439-1, NF C 63421 and EN 61439-1 standards. To avoid using these coefficients, it is necessary to allow a good ventilation and to separate the devices with 0.5 module spacing elements (cat. N 4 063 07). 4 / 5

6. COMPLIANCE AND APPROVALS In accordance with standards:. EN/IEC 60898-1 (Switches for domestic fixed installations and similar 2nd section : special requirements for remote electromagnetically controlled switches (remotes switches) with 6000 A breaking capacity. EU guidelines : 73/23/EEC + 93/68/EEC. Legrand circuit-breakers can be used under the conditions of use as defined by EN/IEC 60947.. The performance of circuit breakers can be influenced by particular climates: hot dry, cold dry, hot humid, salt fog atmosphere Classification according to Annex Q (standard IEC/EN 60947-1) :. Category C with a range test temperature -25 C / +70 C. Salt fog atmosphere according IEC 60068-2-52 Environment respect Compliance with EU directives:. Compliance with Directive 2011/65/EU of 08/06/11 called "RoHS" which provides for the banning of hazardous substances such as lead, mercury, cadmium, hexavalent chromium, brominated flame retardants polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) from 1 st July 2006. Compliance with Directive 91/338/EEC of 18/06/91 and Decree 94-647 of 27/07/04 Precious metal:. Silver: 0,08 g per pole of MCB. No gold Plastic materials :. Halogens-free plastic materials.. Marking of parts according to ISO 11469 and ISO 1043. Packaging:. Design and manufacture of packaging in accordance with Decree 98-638 of 07.20.98 and Directive 94/62/EC 7. EQUIPMENT AND ACCESSORIES Wiring accessories:. Supply busbar Possible combinations of MCB s and auxiliaries:. No auxiliary is associable to the MCB RCD add-on modules:. No RCD add-on module 5 / 5