BERMAD Waterworks. Insertion Flow Meter Device (IFM)

Similar documents
MC608 Converter. Installation Manual Vers. 6.0 and subsequent PLEASE READ THESE INSTRUCTIONS AND KEEP IN A SAFE PLACE ENGLISH TD ENG

MAG ver MAG flow meter. Installation Manual READ AND KEEP THESE INSTRUCTIONS IN A SAFE PLACE

Liquid Turbine Flow Meter OwnerÊs Manual

List of Contents. Agrimag User Guide 1 V V

MAGPOWR Spyder-Plus-S1 Tension Control

OVERVIEW OF CONTROLS

Instruction of connection and programming of the VECTOR controller

Marsh McBirney Flo-Dar

HYDRUS ULTRASONIC METER

Model TUR-200D Turbine Flowmeter

BRAKE TESTER DECELEROMETER

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Positive displacement batch controller

Vantage 6000 Portable Ultrasonic Flow Meter

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Options guide. Electromagnetic flowmeters. M9xx

Proline Prosonic Flow 93T Portable

Section 55 Chapter 6

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

BAYLAN AUTOMATED TEST BENCH

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

MAGNETIC INDUCTIVE FLOW TRANSMITTER

Superstatic 440. Static Heat- and Cooling Meter. Application

APP EOLE4. Applicable to program versions TAC5 Version DT & DG 2.7.0

Off Grid Solar Inverter. LVS 50M User Manual

1.0 Features and Description

User Manual Solar Charge Controller 3KW

ISTEC MAGNETIC METERS

HG 20F-012E-01 OIL CONTROL GUN

Range of Ultrasonic Flowmeters.

ECONOMISER SERIES E2T USER MANUAL

RUN ACCUM. TOTAL STOP BAT LOW HIGH

User Manual. Solar Charge Controller 3KW

2013 Elite T4000 (TM461C) Service Manual

PowerView PV380-R2 Mechanical Configuration

TRANSIT TIME FLOW METERS

ULTRASONIC FLOW SENSOR IFX-M4-01

Appendix. Clearance. Skewed profiles. Application Schematics

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

CS-250 Series. CHAIR SCALE SERVICE MANUAL (v1.06d)

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Operating Manual Model- P282 Digiflow Controller

UTM10 Series Ultrasonic Transit-time Flowmeters

IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL

LS8.0T Service Manual

MATRIX LLC LEVEL CONTROL PANEL

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

INSTALLATION USER MANUAL

Installation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

LTX RF LEVEL SENSOR. Instruction Manual

Electromagnetic flowmeter. Descriptions. Specifications

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

ADDENDUM TO THE STC PRO LOGGER II MANUAL

CITIZEN. series. Precision Balances

F-2700 SERIES INSERTION VORTEX FLOW METER

Issue 2.0 December EPAS Midi User Manual EPAS35

User Manual. Hybrid PV Inverter. Version: 2.1

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

MagFlux Q 8200 Series

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Orica Seismic Electronic Initiation System OSEIS TESTER. Manual

MFM220 & MFM220DC Plastic-Bodied Magmeter

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

1. Introduction OHY1P kW Hybrid Inverter USER MANUAL V2.0

THUNDERBIRD. Agricultural Weighing Systems SS1000 Instructions

Sturtevant Richmont. PST 1000 (P/N 10478) Owners Manual

MFM300 Plastic-Bodied Magmeter

LAMBDA SENSOR CONTROLLER

Model 5000 Vortex Meter

Electromagnetic flowmeter EMKO E

BMS16. Thanks for your purchasing the BMS16 for your vehicle.

Advanced Force / Torque Indicator

Turny Evo. Autoadapt. Seat lift. Installation manual

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7

Series 7000 Torque Sensor for PTO-shafts

PORTAGAUGE 4 USER MANUAL

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

INSTRUCTION MANUAL DIGITRAC % 2 DIGITAL TENSION READOUT AND CONTROL

GRAVITY MEASUREMENT, INC.

Insertion magnetic inductive flowmeter

Model 1000 Vortex Meter

POSITIVE DISPLACEMENT FLOWMETER

User Manual. SP10000 Premium

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Series 7000 Torque Sensor for PTO-shafts

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

Model FMBC3000 Series Operating Instructions. Drum Pump Flow Meter

Transcription:

IFM-MUT1222PRV BERMAD's IFM-MUT1222-PRV SENSOR is designed for measuring the flow rate of valves sized DN80 to DN600 (3-24 ). This document describes the installation process of the sensor. For larger diameter valves use model IFM-MUT1222. The insertion sensor should be mounted at the upstream port of the control valve (the water entrance side to the valve). The devise is designed to be mounted into 1 BSPT threaded port. We recommend using a factory installed and calibrated device, however these processes can be also done in BERMAD's subsidiaries shop or on site. Parts List: 3 1 10 1. Sensor MUT1222-PRV separate version 2. Converter MC608A 3. Cable set 4. Wall/pole mounting kit 5. Panel mounting kit 6. Sealing disk + O-Ring 7. Stud bolt bolts M8 short 8. Stud bolt bolts M8 long 9 9. M8 nuts 10. Spacers 7 8 6 5 4 2 1

Step by step mounting instructions: 1 Apply Teflon sealing band on the sealing disk 1 thread 2 Screw the sealing disk into the 1 BSPT port; use two regular screws to lock the disk temporally in the up-right position as indicated on the disk. Tighten the disk gently Important: do not tie the sealing disk till the very end of its tread; only position it in the up-right position * If overrides, unscrew it backwards to the correct position Note: Do not apply excessive torque, tighten gently! 3 4 Remove the temporary screws from the disk Fasten the fixing screw using 4mm Allen key to prevent the disk from twisting 2

IFM-MUT1222PRV 5 Use the table below to select the correct three Short or Long stud bolt according to the valve DN size. Use the supplied 6mm wrench to screw-in the painted green side of the stud bolt till the stud bolts are locked against their thread end 6 6 Carefully insert the sensor into the disk, make sure not to damage the O-ring Note: that the sensor can be inserted in one position only 6 7 8 Screw the three 8mm nuts but do not lighten them yet Select the correct spacer combination according to valve s size using the table below 3

9 Tighten the nuts but make sure not to apply excessive torque, it may damage the plastic spacer Spacer Combination Table Size Spacers Combination Stud Bolts 600 / 24" 0 (none) Short 500 / 20" B Short 450 / 18" A+B Short 400 / 16" A+C Short 350 / 14" C+B Short 300 / 12" A+B+C (D) Short / Long 250 / 10" A+D Long 200 / 8.0" B+D Long 150 / 6.0" A+B+D (C+D) Long 125 / 5.0" A+B+D+E Long 100 / 4.0" A+C+D Long 80 / 3.0" A+C+D+E Long 65 / 2.5" A+C+D+E Long 50 / 2.0" B+C+D Long E B The picture above is an example of the spacer letter marks 4

IFM-MUT1222PRV 10 Note: Cables glands are factory oriented downwards. If necessary, slightly loosen the v-clamp nut (10mm key) and turn the box only by the minimum required to obtain a new position. Fasten back the v-clamp. Note that the Maximal permitted rotation is 180. 11 For IP68 applications fill the junction box with resin locally, wiring and orientation must be processed first! Make sure that the system works ok before applying resin Remove the sensor from the line Leave the sensor vertically and not covered for 1 hour after filling to ensure Resin curing time 5

Sensor position Please Note: The sensor is calibrated for working on the up-stream right side port of the valve (as per below pictures). Installing the sensor on the up-stream left side port will lead to negative readings. In such case for obtaining positive reading, invert A and B cables; this inverts the magnetic field signal, and provides positive reading. Negative reading does not affect the sensor accuracy. Electronic connection between the sensor and the converter CAUTION! ANYWORK DONE ON THE ELECTRICAL JUNCTION BOX OR ELECTRICAL COMPONENTS OF THE DEVICE MUST BE CARRIED OUT BY PROPERLY TRAINED AND SPECIALIZED STAFF. 6

Converter connections box IFM-MUT1222PRV FREQ OUT + - GROUND PROG IN + - PS485 GND A B SENSOR COIL SIGNAL HARDWARE VERSION 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 Main power MC608A connection: 90...264 Vac 12/24 Vac/dc L N - + 4-2mA PROG OUT PULSE OUT + - 24VDC OUT MAX 30mA BATTERY PACK RESET USB CABLE CONNECTION NOTE: ELECTRICAL GROUNDING OF THE CONVERTER CASE The MC608 case must be grounded. This connection should be carried out by grounding the bolt located at the lower part of the converter. 7

Connection to the power supply CAUTION! ELECTRICAL CONNECTION OF THE DEVICE MUST BE CARRIED OUT BY PROPERLY TRAINED SPECIALISTS. Make sure that all the electrical connections are correctly performed before connecting the unit to the power supply. Check the power voltage as depicted on the name plate. The unit may be supplied with voltage: MC608A: 90-264VAC or 12... 24VAC/DC MC608B: Powered by a lithium battery 12-24VAC/DC MC608R: Powered by a rechargeable lithium battery 12-24VAC/DC Power supply and battery charging is supplied by the solar panel. Programming the mc608 converter MC608 configuration can be performed in the following methods: By the 4 push buttons located on the front display of the converter, under the front panel glass. Via PC through the RS485 MODBUS output (see electrical connections) and the Euromag MC608 configuration software program. USB cable adapter is available at the manufacturer on request. From a PC via the infra-red port located on the front of the converter above the display, and the MC608 Euromag configuration software. Activation of the MC608B or MC608R in battery mode: The normal operation mode of the MC608B is the "sleep mode". This mode preserves battery life while ensuring functional operation of the product. To recall the unit for reading the display or changing the program settings use the supplied magnetic swipe and slide it vertically on the front panel of the converter at the "activate" marking. 8

Programming IFM-MUT1222PRV To access the menu from the converter s display, simply press the relevant button below the function. Enter the Menu by pressing the Menu button. MENU: Options Counters Parameters I/O Other Memory Follow the chart below for an overview of the available functions. Options Counters Parameters I/O Other Memory Technical units T+ Ka setup Pulses OUT System info Load user copy Flow rate units P+ (set Diameter Setup Pulse quantity Time/Date Save user copy zero) Flow rate time base T- Filters setup Pulses time ON Reserved Factory settings Counters module P- (set Flow cut off Reverse flow rate Graph Data logger zero) Pulses unit Damping Pulses out enable Simulation Show last row Specific weight Bypass Frequency output Communications Full erase Temperature unit Peak cut Full scale freq. Baud rate RS485 LOG range Measurement frequency Measure average Frequency output enable MODBUS address Measuring time Line frequency Program. Output Data connection Display Zero calibration Enabled/disabled LCD backlight lev Flow rate alarms Reverse Flow Backlight off MAX flow th. MAX flow th. LCD contrast MIN flow th. MIN flow th. View options Empty Pipe th. MAXIMIN flow th. Last row Batching Full scale flow Excitation failure Language Empty Pipe Program. Input Enabled/disabled Zeroing p+ Zeroing p- Zeroing p+/p- Batching Progr. output Iogics Password setup 9

Data to be displayed The display is divided into three main areas: The top area shows the symbols for status information together with the indication on the duration of the battery (MC608B and MC608R). Power indication (MC608A) or indication on battery. The central area shows The area at the bottom Supply and charging (MC608R), as well as the alarm symbols and real-time reading of the flow rate. a linear graph of the flow rate shown in percentage on the full scale flow rate. can be selected by the customer; the possible options are: T+ total positive counter P+ partial positive counter T- total negative counter P- partial negative counter Date and time, temperature or pressure display (the latter available with optional module). To select the required value simply click on the button corresponding the arrow and make your selection, or select: Menu -> Options -> view options -> Last row Status icon 0.0000 m3/h 0.0% 0.0m/s 0.0% 0.0m/s 11.6443 menu t+> m3 0.0000 11.6443 menu t+> m3/h m3 Keypad for programming STATUS ICONS / POWER SUPPLY Power Supply Power Batteries (remaining) Charging Batteries (rechargeable version) 10

ALARM ICONS flow rate > MAX threshold flow rate < MIN threshold excitation failure measurement error empty pipe alarm alarm for pulses accumulation board temperature alarm (with unit set) low voltage alarm full data logger alarm IFM-MUT1222PRV COMMUNICATION STATUS Data connection in progress Calibration Process: NOTE: it is always recommended to order the IFM and the VALVE connected and factory calibrated. In case this is not possible, there are two options: 1. On-site Laboratory calibration (always recommended) 2. Field Calibration (when there is no other choice) Laboratory calibration procedure: NOTE: please ensure selection of the right calibration spacer (according to the Spacer Combination Table ). Test Method Comparison between the IFM Meter to be calibrated and the Test-Bench Master Meter NOTE: Before starting the calibration ensure that proper grounding is connected! Steps: 1. Clamp the device, Open the water, and make sure there are no leaks. 2. Release air by initiating flow through the water meter. 3. Make, zero calibration. 11

Options > Parameters Zero calibration EUROMAG EUROMAG MC 608 MC 608 Parameters Ka setup diameter setup filters setup zero finder flowrate alarms empty pipe th. ok << zero finder X 20% ACTIVATE www.euromag.co.il ACTIVATE www.euromag.co.il NOTE: The MC608 has an automatic zero calibration function. Use the zero finder only when strictly necessary. NOTE: If double regulating valves are not present for regulating flow rates, use the testing Valve as ON/OFF Valve. 4. Measuring accuracy test at two points 1.0m/s and 3.0m/s. repeat each test twice. Minimum test time should be at least 5 Minutes. 5. Calculate the error according to the explanation in the Measurement error calculations. 6. Compliance - End calibration. NOTE: in order to enter or change the diameter the technician password is required. Technician password: 231042 12

Options > Memory Password setup EUROMAG IFM-MUT1222PRV MC 608 7. Non-compliance Calibration the IFM by changing the diameter Positive error above the allowable > Reduce the IFM diameter size. Negative error above the allowable > Increase the IFM diameter size. 8. After calibration, repeat the test in section 3 until result are in compliance. password 0**** enter pwd requested level: 1 ok <> ACTIVATE www.euromag.co.il Options > Parameters Diameter Setup EUROMAG EUROMAG MC 608 MC 608 Parameters Ka setup diameter setup filters setup zero finder flowrate alarms empty pipe th. ok << diameter setup 169mm +/- 1 <+/-> ok ACTIVATE www.euromag.co.il ACTIVATE www.euromag.co.il Measurement error calculations Calculate the corrected electromagnetic flow-meter (master) reading using the equation IFM Accuracy = 100% X Master - IFM Master Compliance and non-compliance Compliance error ±2.5% (in measured points 1.0m/s and 5.0m/s) Non-compliance above ±2.5% (in both measured points 1.0m/s and 5.0m/s) 13

Field Calibration: NOTE: Field Calibration is less recommended than Laboratory calibration, the accuracy will be ± 5.0 ~ 10 % depends on the calibration method and on the master meter accuracy. The field calibrating is not authorized by any standard. There are 3 options for field calibrating: Calibration based on comparison to other flow meter on-site. Calibration based on comparison to volumetric tank on-site. Calibration based on comparison with temporary flow meter such as Clamp-on ultrasonic flow meter which is installed only for this purpose. For this we recommend to use Clamp-on ultrasonic flow meter model: FLUXUS F601. In these three options the Test Method is the same as in the Laboratory calibration procedure only with difficulty performing the required Flow / Amount. Trouble-Shooting: SYMPTOMS: The converter shows a flow rate under static or no flow conditions. POSSIBLE REMEDIES: There is air in the pipe, try to avoid the creation of bubbles by selecting a more suitable position for the sensor (see installation paragraph). Check that the sensor is fully inserted to the liquid. Electrical conductivity of the liquid is too low or is not compatible with the material used for the sensor electrodes. Perform manual zero calibration if necessary (Menu - Parameters, sub- menu - zero calibration). SYMPTOMS: Flow reading is highly unstable POSSIBLE REMEDIES: Air bubbles or unstable flow. The minimum required linear distances upstream and downstream of the device are not met. Missing grounding or incorrectly done, oxidized nodes, very noisy ground point, usually in common with the grounding systems of pumps or inverters. Change the grounding point or preferably install a new one for the exclusive use of the meter. NOTE: If with full pipe and stable liquid an unstable reading is observed (which varies rapidly) then most likely it is a problem of electrical noise. Only if necessary, set the filters as follows: Set Damping to 150 Reduce the peak cut filter Increase the bypass filter 14

SYMPTOMS: The display is off and does not turn on. IFM-MUT1222PRV POSSIBLE REMEDIES: There is no voltage supply, or the voltage supply is incorrect. Check the power supply voltage on the name plate of the converter. In case of MC608B check the battery life and replace the battery pack. SYMPTOMS: Liquid is flowing and the pipe is full, but NO reading is available. POSSIBLE REMEDIES: Reduce the flow cut off filter (factory settings is 2% of the full scale). NOTE: Should you need to reduce the flow cut off filter, it means the speed of the liquid is lower than that recommended for an accurate measurement. It is advisable to lower the full scale (120% of the maximum of the process). ALARM MESSAGES Excitation failure Measurement error Empty Pipe Pulses accumulation Supply voltage Data logger full POSSIBLE CAUSES AND SOLUTIONS Incorrect connections of cables Sensor damaged. Damaged lining or electrodes. Possible infiltration of liquid inside the sensor Converter damaged It is recommended to perform a test on the sensor -> circuit between coils A - B: 50-250 Ohm Request the sensor test to the factory Empty Pipe Air bubbles within the liquid Incorrect electrical grounding It is advisable to check for correct installation of the sensor in the three points indicated and carry out a test on the sensor -> with full pipe (A or B) - ground > 100 MOhm Empty pipe detection This message is displayed with sensors that have 4 electrodes. Indicates the alarm of empty pipe, or even only partially empty. In case of persistent message with full pipe (more than a few minutes) act on the empty pipe threshold (see section 10.3.6 Empty pipe threshold). Pulse frequency incorrect It is advisable to change the volume settings and pulse duration. See the section for pulse output setting Supply voltage out of operating range Converter damaged Check the power supply network Data logger memory full It is advisable to download the data to PC, and erase the memory of the converter 15

Spare Parts: 1" sealing disk and O-Ring Spacer - diameter adaptors set Cable set for 5m or 10m Grounding rings Bottle of sealing resin for sensor's junction box Pressure sensor 21Y Series made by KELLER PT 500 Probe Cable for Pressure sensor 16