Advanced Air Driven Gas Boosters and Amplifiers. Sprague. Air Amplifiers. Gas Boosters

Similar documents
Sprague Air Driven Pumps, Gas Boosters & Power Units

HOW THE SPRAGUE PRODUCTS BOOSTERS WORK

Air Driven Gas Boosters

Sprague. Advanced Air Driven Pump System

SPRAGUE PRODUCTS AIR DRIVEN HYDRAULIC PUMPS

Air Driven Hydraulic Pumps, Gas Boosters, Power Units, Specialty Valves & Accessories L & LS SERIES

Fluid Control Solutions. Pumps & Boosters. Petrometalic SA 32, rue de l Ermitage VERSAILLES

liquid Pumps Air driven contents Chatsworth, California, USA LP500C

LX SERIES Low-Pressure Gas Compressors

LX-SERIES Low-Pressure Gas Compressors

Welcome to SHINEEAST. Genaral Information

Pressure on Demand. Pneumatic and Hydraulic Driven Gas Boosters

LIQUID PUMPS HII AIR DRIVEN CONTENTS LP500D. How the Pump Works, Advantages of the HII Pumps, How to Select Air Driven Pumps...2

LX SERIES Low-Pressure Gas Compressors

DB MX1 5" 12" 2" S P S

HYDROSTATIC TEST SYSTEM MANUAL

CenterFlo Pumps. Air Operated Double Diaphragm (AODD) Pumps. Automotive Commercial Industrial

627 Series Pressure Reducing Regulators

D5 & 10-5 SERIES AIR OPERATED LIQUID PUMPS

SC HYDRAULIC ENGINEERING CORPORATION

Product overview. Technical data

LIQUIDYNAMICS 1:1, 3:1 and 5:1 RATIO AIR OPERATED OIL PUMPS

Model: ACP-12 AUTO COMPRESSOR PUMP SYSTEM 12 VDC INSTALLATION & OPERATION MANUAL. Phone:

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

L3 SERIES COMPACT PUMPS

Pressure Instrument Testing Equipment

Aircraft Suspension Systems

Industrial Pumping Equipment Air-Operated Diaphragm Pumps

Continuous Run Vent Unloaders

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Applications. Compressor-Features The Vilter Advantages. LNG Boil Off Gas Gathering BIO - Gas Digester CO 2 Nitrogen Hydrogen Refrigerant

627 Series Pressure Reducing Regulators

MICHIGAN FLUID POWER

627 Series Pressure Reducing Regulators

EZ-View. Flow Meters ISO CERTIFIED 9001

Cylindrical Pumps. J-Series Cylindrical Venturi Pumps

4/3/2014 Ryobi Electronics Parts Catalog -- Ryobi Power Tools Consumer: [H301PL 3 Gallon Air Compressor (Husky)]/[Figure A]

E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions

CASH VALVES TYPE G-4 PRESSURE REGULATORS

Compressed Air Systems Catalog

Hydraulic and Pneumatic In-line and Cartridge Insert Control Valves for any fluid or gas.

Valves and Equipment

CASH VALVES TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES

CASH VALVES TYPE G-60 PRESSURE REGULATORS

Gas Spring Service & Maintenance Accessories

Series 111 Accumulator Product Information

Series: hydraulic-type control in pneumatic machinery

Operation and Maintenance Manual

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

Hydronic Corporation

CASH VALVES TYPE G-60 HIGH CAPACITY PRESSURE REGULATOR

SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Industrial Pumping Equipment PileDriver III Series III Air Motor Features

Flow Limit Safety Shutoff Valves Model 1

E, H & P Series Air/Oil intensifier pumps

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

QUINCY QRDS SERIES SINGLE-STAGE, OIL-LESS RECIPROCATING AIR COMPRESSORS 2-30 HP

Air Nozzles and Jets. Drastically Reduce Compressed Air Consumption. Reduce your operating costs significantly with our nozzles and jets.

SOLUTIONS. Airless Spray System. In This Issue: Airless Spray System pg. 2. Improved FlowMaster pg. 5

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 2 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 50 BOLTED. A JDA Global Company

Series Regulators - Pressure Reducing

Valves. E Valves. Multiple Hydraulic System Applications

LogSplitterPlans.Com

SERIES. CRYOGENIC/PRESSURE BUILD REGULATOR 3/8 and 1/2" NPT, BSPT Inlet 400 Psig (28 Bar) Description

Quincy QT. Reciprocating Compressors 3-30 Horsepower. Highly Efficient Leading the industry with more CFM per brake hp

FPC815 Pneumatic Rivet Tool

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

Hydraulic Master Cylinders

Solenoid Valve Manifold for use with Digital Pressure Control Coupler

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS .5 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 15

Direct solenoid and solenoid pilot operated valves

SECTION II AIRPLANE AND SYSTEMS MODEL 750 HYDRAULIC

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

Section J Air Control Nozzles

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev.

Inline Pulse-Tone. Hydraulic Shock Suppressors. Inline Pulse-Tone Shock Suppressors Feature:

McGUIRE AIR COMPRESSORS HP RECIPROCATING AIR COMPRESSORS. R-Series. McGUIRE AIR COMPRESSORS

Lynx 3:1 Pump. Model: OPERATION, INSTALLATION, MAINTENANCE AND REPAIR GUIDE

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Direct-Operated Pressure & Temperature Regulating Valves

TRANSFER PUMP INSTRUCTIONS P/N 14251NOS

Industrial Pumping Equipment PowerMaster III

Auxiliary Equipment. Table of Contents. Auxiliary Equipment H-1. Product Product Code Technical Instructions Page #

Bellows Pumps. The Newest Technology in Piston Pumps

Compressed Air Systems Catalog

Pulsation Dampeners NEW! Wanner Engineering Inc

OIL-FREE, ROTARY SCREW AIR COMPRESSORS Two-stage, Air-cooled and Water-cooled Fixed Speed or VFD

WDV-2 2-way normally closed poppet with air pilot. When valve closes a spring biased internal piston draws back a small volume on outlet side (approx.

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

Describe the function of a hydraulic power unit

Distributed By: M&M Control Service, Inc Product Product Code Technical Instructions Page #

Right Angle Nozzle Assembly

Pilot-Operated Safety Relief Valves

POWER CLAMPING. Power Clamping. Air-Powered Hydraulic Pumps

Maximum Pressure. High Pressure Technology Testing Equipment Hydraulics Pneumatics.» Air driven high pressure pumps up to 7,000 bar (101,000 psi).

Palletized Fixture Accessories

Operation & Service Manual

08 WASTE OIL EQUIPMENT

Transcription:

Advanced Air Driven Gas Boosters and Amplifiers Sprague Gas Boosters Air Amplifiers

Gas Boosters and Systems Works off compressed air supplies Operates quietly Features mechanical separation between air drive and boosted gas Compatible with most gases The PowerStar 4B gas booster is a reciprocating, single or double or dual stage air operated unit. It uses an air-piloted unbalanced type air directional valve to cycle the booster. The Principles of Operation The PowerStar 4B gas booster operates on the differential piston area principle. A large area piston, driven at low air pressures, drives a small area compression piston which converts input gas to higher pressure. The output gas or discharge pressure is determined by the ratio between the area of the drive piston, the operating air pressure and the available precharge pressure supply. The function of the precharge pressure is to charge the high pressure cylinder inside the booster with gas, reducing the time needed to reach higher pressures. In double-ended gas boosters, the precharge gas adds power to the compression stroke. The Actual Operation The PowerStar 4B gas booster works rapidly at first, then slows and stops at a pressure balance. The booster holds the pressure balance indefinitely, assuming no leakage. When a pressure imbalance occurs, the booster automatically restarts and restores the pressure balance. During operation, exhaust air from the air drive section cools the high pressure boosting chamber. The Gas Booster in Action Whether you use gas above normal cylinder pressure or require continuous high pressure and want to get the most out of the cylinder's gas supply, the PowerStar 4B Series is for you! It assures the optimum use of commercially-bottled gas. Some units draw a vacuum. 2 The applications for this versatile gas booster are endless and include: Aviation and Aerospace Static and dynamic testing of valves and components at overhaul facilities Inflating high pressure aircraft tires Instrument calibration Automotive Air bag testing Gas spring charging systems for die and mold manufacturers Accumulator charging Petrochemical Heel recovery from cylinders for gas transfer Gas blanketing Diving Filling air tanks from larger cylinders Testing air pressure regulators Gas mixing Fire Protection Filling breathing air cylinders Mobile filling stations for firefighters Halon and CO 2 charging Fluid Power Testing hoses and valves Testing and calibrating gas components Accumulator charging Machine Tools Power clamping Quick die change Plastics Ejecting parts from molds Gas injection Packaging Injecting nitrogen into aerosol cans

TABLE 1 GAS BOOSTER PERFORMANCE Approximate performance based on a maximum air consumption of 50 SCFM Gas Inlet Port Outlet Port Booster Precharge Pressure DISCHARGE CAPACITY-Standard Cubic Inches per Minute (SCIM) Model Pressure (w/100 psi DISCHARGE PRESSURE-psi Number psi driving air) 200 400 600 800 1000 2000 3000 4000 5000 6000 7000 8000 P4BS010 100 1000 4593 4176 3854 3533 P4BS010 200 1000 8598 7815 7215 6614 P4BS034 400 3400 4388 4342 4296 3683 3314 P4BS034 500 3400 5447 5390 5332 4571 4114 P4BS050 400 5000 2747 2709 2517 2382 2248 2171 P4BS050 500 5000 3410 3362 3124 2957 2790 2694 P4BS080 600 8000 2353 2186 2002 1919 1852 P4BS080 1000 8000 3883 3608 3305 3167 3057 S010P4BS010 50 1050 4405 4004 3696 3388 S010P4BS010 100 1100 7808 7099 6552 6006 S010P4BS010 200 1200 14617 13286 12266 11244 S034P4BS034 300 3700 5661 5602 5542 4752 4276 S034P4BS034 400 3800 7460 7381 7303 6261 5634 S034P4BS034 500 3900 9260 9163 9064 7771 6994 S050P4BS050 400 5400 4670 4605 4279 4049 3822 3691 2117 S050P4BS050 500 5500 5797 5715 5311 5027 4743 4580 2627 S080P4BS080 600 8600 4000 3716 3403 3262 3148 1889 S010P4BS034 100 3840 3109 3109 3053 2855 2533 S010P4BS050 100 5600 3109 3109 3053 2855 2691 2533 2329 S010P4BS080 100 8900 3109 3081 3053 2940 2883 2770 2657 2544 2431 2318 TABLE 2 GAS BOOSTER PERFORMANCE Approximate performance based on a maximum air consumption of 50 SCFM Gas Inlet Port Outlet Port Booster Precharge Pressure Time required in minutes to fill a 100 cubic inch air receiver to listed discharge Model Pressure (w/100 psi DISCHARGE PRESSURE-psi Number psi driving air) 200 400 600 800 1000 2000 3000 4000 5000 6000 7000 8000 P4BS010 100 1000 0.4 0.8 1.2 1.7 P4BS010 200 1000 0.2 0.4 0.7 0.9 P4BS034 400 3400 0.8 1.1 3.0 5.3 P4BS034 500 3400 0.4 0.9 2.5 4.3 P4BS050 400 5000 1.0 1.5 4.4 7.6 11.1 15.1 P4BS050 500 5000 0.6 1.0 3.3 5.9 8.7 11.9 P4BS080 600 8000 6.9 10.0 14.7 18.8 23.1 27.9 P4BS080 1000 8000 3.5 5.4 8.1 10.6 13.1 16.0 S010P4BS010 50 1050 0.5 0.9 1.4 1.9 S010P4BS010 100 1100 0.3 0.5 0.7 1.0 S010P4BS010 200 1200 0.1 0.2 0.3 0.5 S034P4BS034 300 3700 0.6 0.9 2.4 4.1 10.0 S034P4BS034 400 3800 0.4 0.6 1.7 3.0 7.4 S034P4BS034 500 3900 0.2 0.4 1.3 2.4 5.8 S050P4BS050 400 5400 0.6 0.9 2.6 4.4 6.5 8.9 S050P4BS050 500 5500 0.4 0.6 2.0 3.4 5.1 7.0 S080P4BS080 600 8600 4.1 5.9 8.7 11.1 13.6 16.4 S080P4BS080 1000 9000 2.5 3.6 5.2 6.7 8.2 10.0 S010P4BS034 100 3840 1.5 2.0 4.4 7.2 11.4 S010P4BS050 100 5600 1.5 2.0 4.4 7.2 10.0 13.7 S010P4BS080 100 8900 1.5 2.0 4.3 6.7 9.4 12.3 15.4 18.9 22.6

Gas Boosters and Systems MODELS Single Ended Ratio Non Separated Double Ended Ratio Non Separated Dual Ratio Non Separated Single Ended Ratio Separated Double Ended Ratio Separated Dual Ratio Separated P4B010 P4B034 P4B050 010P4B010 034P4B034 050P4B050 010P4B034 010P4B050 P4BS010 P4BS034 P4BS050 P4BS080 S010P4BS010 S034P4BS034 S050P4BS050 S080P4BS080 S010P4BS034 S010P4BS050 S010P4BS080 PORTING Gas Booster Inlet Ports Outlet Ports Inlet Ports Shipping Weight Model Gas Gas Air Approx. All single-ended 3/8" NPT 1/4" NPT 3/8" NPT 20 lbs. All double-ended 3/8" NPT 1/4" NPT 3/8" NPT 25 lbs. 12.58 DIMENSIONS 5.92 Single-ended Booster 17.63 6.03 Double-ended Booster 4 Dual Ratio Booster

Breathable Air Booster and Oxygen Service Booster Oxygen service booster P/N 93992-034-OX Breathable air booster HPU-1200 Bootstrap Configuration - Number of Fills Storage cylinder SCBA cylinder to be filled 2216/45 4500/45 4500/88 2250/72 3000/80 STORAGE CYLINDER BOOSTER FILL CYLINDER Bootstrap Configuration 2400/260 3.2 1.6 0.8 2.2 1.2 4500/444 8.1* 4.5** 2.3 5.0 3.6 5000/450 9.0 5.1 2.6 5.6 3.9 6000/509 11.0 6.7 3.4 6.9 4.6 *represents an increase in total fills from 6.5 to 8.1 when using a booster. **represents an increase in total fills from 0 to 4.5 when using a booster. Compressor Configuration - Number of Fills Storage cylinder SCBA cylinder to be filled 2216/45 4500/45 4500/88 2250/72 3000/80 STORAGE CYLINDER BOOSTER FILL CYLINDER Compressor Configuration 2400/260 6.2 5.5 2.8 3.9 3.4 4500/444 12.0* 10.2** 5.2 7.5 6.4 5000/450 12.4 10.3 5.3 7.6 6.5 6000/509 14.0 11.8 6.0 8.8 7.3 *represents an increase in total fills from 6.5 to 12.0 when using a booster. **represents an increase in total fills from 0 to 10.2 when using a booster. Inlet Pressure psig Fill Times (Minutes) SCBA cylinder to be filled 2216/45 4500/45 4500/88 2250/72 3000/80 500 28.5 32.9 64.2 45.8 54.7 1000 10.3 14.6 28.5 16.6 22.2 1500 4.0 8.4 16.4 6.7 11.1 2000 0.9 5.2 10.3 1.7 5.6 Notes: 1. The booster will operate using a small compressor that is continuously rated from 1.5 HP/6 SCFM to 10 HP/50 SCFM at 100 psi. 2. Fills and times are based on empirical and laboratory data, and can be adversely affected by plumbing configuration, leaks, cylinder capacities, etc. 5 3. All tables are based on 100 psi drive air pressure, 500 psi minimum inlet pressure, 500 psi initial fill cylinder pressure, average air motor consumption of 13 SCFM, and using the PowerStar S050P4B050 booster.

Advanced Air Driven Air Amplifier Performance Chart: AA4P4AA4 Double-ended Air Amplifier OUTLET PRESSURE PSI (41 bar) 600 (34 bar) 500 (28 bar) 400 (21 bar) 300 (14 bar) 200 (7 bar) 100 125 PSI DRIVING AIR (8.75 bar) 100 PSI DRIVING AIR (7 bar) 50 PSI DRIVING AIR (3.5 bar) 0 1 2 3 4 5 6 7 8 scfm 28.3 N. LITRES/MIN. 20 scfm 30 scfm (OUTLET FLOW) (NOMINAL RATING) 226.5 N. LITRES/MIN. 40 scfm Solid lines indicate approximate flows at various driving air pressure. Dotted lines indicate air consumption in scfm. All air driven air amplifiers will operate on low air volumes as long as the supply is sufficient to overcome minor internal leakage and operate the air selector valve in the air motor section. Note: most air compressors produce 4-5 scfm of compressed air per horsepower at 100 psi. As an example, with 100 psi (6.8 bar) driving air, the air amplifier consumes 30 scfm at an operating pressure of 200 psi (14 bar) and produces an output flow of 3.5 scfm. Note: for applications above 450 psi (31.5 bar), consult factory. Note: stall conditions on double ended units are best achieved by regulating air motor pressure 10% lower than precharge. Nominal Dimensions: Single-ended and Double-ended Single-ended P4AA4 Double-ended AA4P4AA4 Air Motor Air Motor Shop Air Supply 125 psi max. Air Module Air Module Air Module 6.03 in. (153.37 mm) 7.78 in. (197.60 mm) HIGH PRESSURE AIR OUTLET 10.39 in (263.90 mm).31 in x 62 in. SLOTTED HOLE 4 PLC S (7.88 mm X 15.76 mm).31 in x 62 in. SLOTTED HOLE 4 PLC S (7.88 mm X 15.76 mm) 1.40 in (35.57 mm) TYP. 2.00 in. (50.80 mm) TYP. 4.05 in (102.93 mm) TYP. 2.00 in. (50.80 mm) TYP. 11.38 in (289.05 mm) 9.63 in. (244.60 mm) 6.34 in. (161.04 mm) 5.58 in. (141.73mm) 4.50 in. (114.30 mm) 6.34 in. (161.04 mm) 5.58 in. (141.73mm) 4.50 in. (114.30 mm).88 in. (22.42 mm) (REF.).88 in. (22.42 mm) 6 SHOP AIR INLET 125 psi max. (Precharge)

How the Air Amplifier Works The PowerStar 4 air amplifier develops high output pressures by applying the principle of differential areas. It features a large area air motor piston (air driven at low 10-125 psi pressures) that drives a small area air piston that amplifies the incoming air pressure. Air output pressure is determined by the ratio between the area of the air motor piston, the area of the small high pressure piston and the applied driving air pressure. The relationship of HIGH EFFICIENCY AIR VALVE Won t hang-up More air flow (less air consumption) the air motor piston to the small area piston is referred to as the Air Amplifier Ratio. In operation, the AA4P4AA4 model using 125 psi input air pressure (at the air motor), can produce a maximum air output pressure of 600 psi (limited to 500 psi in the P4AA4PCT and AA4P4AA4PCT models with an ASME tank rated at 500 psi). At 100 psi input air pressure, the air amplifier can produce an output air pressure of 450 psi; at 50 psi input pressure, it can produce an output air pressure of 300 psi. INTERNAL MUFFLER Reduces noise Minimizes icing Cools pump module More compact AIR AMPLIFIER MODULE STAINLESS STEEL Suitable for virtually all services SELF-LUBRICATING SEALS Suitable for clean rooms Eliminate pre-lubrication Eliminate exhaust air contamination TEFLON SEALS Maximum seal life Easy to service INTERNAL CHECK VALVES Oversize flow path permits highest flow rates Easy to service Weights & Porting Approx. Air Amplifier Inlet Port Outlet Port Inlet Port Shipping Model No. Air Module Air Module Air Motor Weight P4AA4 1/2 NPTF 3/8 NPTF 3/8 NPTF 16 lbs (7.26 Kg) AA4P4AA4-8, 37 deg. Male flare fittings 3/8 NPTF 21 lbs (9.53 Kg) P4AA4PCT 1/2 NPTF 3/8 NPTF 3/8 NPTF 80 lbs (36.3 Kg) AA4P4AA4PCT 1/2 NPTF 3/8 NPTF 3/8 NPTF 85 lbs (38.6 Kg) Typical 5 gallon ASME Tank 14.5 in 6.375 in 6.75 in 0.75 in NPT typ. Order Information Components P4 AA4 P4AA4 AA4P4AA4 A Systems P4AA4PCT AA4P4AA4PCT Description Air Motor Module Air Amplifier Module Single Air Amplifier (Assembled) Double Air Amplifier (Assembled with plumbed inlets & outlets) Air Control Kit (Filter, regulator, gauge, fittings) Description Single Air Amplifier, Complete System (5 gal. ASME tank, 500 psi rating, ASME relief valve, gauge, shut-off valve) Double Air Amplifier, Complete System (5 gal. ASME tank, 500 psi rating, ASME relief valve, gauge, shut-off valve) 7 9.5 in

Other Sprague Products Hydraulic Pumps, Gas Boosters, Power Units, Specialty Valves & Accessories Nitrogen Gas Booster Assembly Advanced Air Driven Power Units Advanced Air Driven Power Units PowerStar 4 Advanced Air Driven Pump Systems 2955 W. 17th Street Erie, Pennsylvania 16505 U.S.A. Phone: (814) 838-2028 1-800-289-7447 Fax: (814) 838-6075 E-Mail: sales@highpressure.com www.highpressure.com 2017 High Pressure Equipment Company Printed in U.S.A.