U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Tuffy Liquid Level Controls with Pneumatic Switch

Series K Pneumatic Switch Mechanism

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

For Hazardous Locations

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L500 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L312 LIQUID LEVEL FLOAT SWITCH. Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L070 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL. For Industrial Use

For CRN Installations

ECHOTEL MODELS 915-P / 915-W

Tuffy II Liquid Level Controls with Electric Switches Installation and Operating Manual

J52 Refrigerant Level Switches

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

INSTALLATION / INSTRUCTION MANUAL

Echotel Trident 91S/92S Ultrasonic Level Switches

ECHOTEL 961/962 LINE POWERED

Tuffy Liquid Level Switches

Series K. Pneumatic. switch mechanism. and housings. Installation and Operating Manual

ECHOTEL 961/962 LOOP POWERED

SOLITEL. Vibrating Rod. Level Switch. for Solids. Installation and Operating Manual. 7xxx. 6xxx. 5xxx. 4xxx. 3xxx. 2xxx. 1xxx

BroadBand PowerShield. 20 AHr Battery. User Manual

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

CTFRP Series Power Supplies

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

A5000GEC-24VDC ZERO SPEED SWITCH

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

ECHOTEL 961/962 LOOP POWERED

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

Switch Pro w/ Compact Junction Box A_1_ Series Owner s Manual

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Installation, Operation, Repair and Parts Manual

6. Electrical. 7. Settings. 8. Quick

INSTALLATION AND OPERATION MANUAL

CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

KOBOLD DF-MA Flow Transmitter. User Instructions

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

ECHOTEL 961/962 LOOP POWERED

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

OWNERS MANUAL JANUARY 2007 ISO

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

TC26-B Vehicle Sensor

Ultrasonic Two-Wire Point Level Control

APM Pneumatic Control for Boiler Feed System Applications

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

USER MANUAL. Tides La Mer Treatment Table Rev A 3/28/19. *all tables shown with optional accessories and/or finishes

INSTALLATION INSTRUCTIONS

Owner's/Installation Manual

SPC-PANEL Simplex, Single Phase Pump Control Panel

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

Type NR oil switch installation and operation instructions

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

DC to AC Power Inverters

DC to AC Power Inverters

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

RP-4000 Reserve Power Control

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

ADI-125/750 ADI-125/1500 ADI-125/2500

1000 Series Piston Type Differential Pressure Gauges

AFM500X Automatic Flashing Module

CVR-625. Compact Vibrating Rod Instruction Manual

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

AGV5-1, AGV5-2 FORM AGV5 OM 11-02

MIL-24/2600Q MIL-24/3200DQ

M-100 Adjustable flow switch with right-angle flow

Swing-Flex Check Valve

Swing-Flex Check Valve

MA-5200 Series MA-5300 Series

7330 Pro-Stik II Magnetostrictive Level System

II DISTRIBUTION & SUBSTATION TYPE C

30 Amp Solar Charge Controller

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

Mobrey 003. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP117, Rev DA. Self-contained liquid level alarm.

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

Operations Manual. Zero Speed Switch Sensor Model ZS09P

INSTALLATION INSTRUCTIONS

RF Point Level Control with Sensor Monitor

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

2-12 Grooved End Dual Disc Check Valve. Operation, Maintenance and Installation Manual

KENCO ENGINEERING COMPANY

COMPRESSED AIR LOADER MODEL: AL-1

ROLLER SPREADER. Model - #171A-M Lee's Chapel Road Browns Summit, NC Tel: (800) Fax: (336) Web:

Operating and Installation Instructions

3820 Pressure Switch-Transmitter

Hermetically Sealed Switches

Transcription:

Model u002 & u003 Installation and Operating Manual Ultrasonic Level Switch 60 Great Hill Road Naugatuck, CT 06770 ph: 203-729-6434 fax: 203-729-6696 www.innovativesensing.com

Read this Manual Before Installing This manual provides information on the Ultrasonic Liquid Level Switch. It is important that all instructions are read carefully and followed in sequence. Detailed instructions are included in the Installation section of this manual. Conventions Used in this Manual Certain conventions are used in this manual to convey specific types of information. General technical material, support data, and safety information are presented in narrative form. The following styles are used for notes, cautions, and warnings. Notes Notes contain information that augments or clarifies an operating step. Notes do not normally contain actions. They follow the procedural steps to which they refer. Cautions Cautions alert the technician to special conditions that could injure personnel, damage equipment, or reduce a component s mechanical integrity. Cautions are also used to alert the technician to unsafe practices or the need for special protective equipment or specific materials. In this manual, a caution box indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Warnings Warnings identify potentially dangerous situations or serious hazards. In this manual, a warning indicates an imminently hazardous situation which, if not avoided, could result in serious injury or death. Safety Messages The Ultrasonic models are designed for use in Category II, Pollution Degree 2 installations. Follow all standard industry procedures for servicing electrical and computer equipment when working with or around high voltage. Always shut off the power supply before touching any components. Electrical components are sensitive to electrostatic discharge. To prevent equipment damage, observe safety procedures when working with electrostatic sensitive components. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING! Explosion hazard. Do not connect or disconnect equipment unless power has been switched off or the area is known to be non-hazardous. Low Voltage Directive For use in Category II installations. If equipment is used in a manner not specified by manufacturer, protection provided by equipment may be impaired. Notice of Trademark, Copyright, and Limitations Copyright 2008 Solutions With Innovation LLC; D.B.A. Innovative Solutions All rights reserved. Innovative Solutions reserves the right to make changes to the product described in this manual at any time without notice. Innovative Solutions makes no warranty with respect to the accuracy of the information in this manual. Warranty All Innovative Solutions electronic level and flow products are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Innovative Solutions will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Innovative Solutions shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Innovative Solutions products. Quality Assurance The quality assurance system in place at Innovative Solutions guarantees the highest level of quality throughout the company. We are committed to providing full customer satisfaction both in quality products and quality service.

Model u002 & u003 ultrasonic level switch Table of Contents 1.0 Introduction 1.1 Description...1 1.2 Principle of Operation...1 1.3 Getting Started...1 2.0 Installation 2.1 Unpacking...2 2.2 Electrostatic Discharge (ESD) Handling Procedure..2 2.3 Mounting...2 2.4 Wiring...3 2.4.1 Relay Output...3 2.4.2 Current Shift Output...3 3.0 Reference Information 3.1 Specifications...4 3.1.1 Physical...4 3.1.2 Electrical...4 3.1.3 Environmental...4 3.2 Replacement Parts...4 3.3 Troubleshooting...5 3.4 Model Numbers...5

1.0 Introduction 1.1 Description Model U002 & U003 Ultrasonic Level Switches are compact integral units that utilize pulsed signal technology to perform high or low level measurement in a wide variety of liquid applications. These switches feature pulsed electronics that are encapsulated at the top of the process fitting and a 316 stainless steel tip-sensitive transducer. Model U003 features a 1 amp SPDT relay output and is also available with a current shift output. 1.2 Principle of Operation The U002 & U003 level switches utilize ultrasonic energy to detect the presence or absence of liquid in a tip sensitive transducer gap. The principle of contact ultrasonic technology is that high frequency sound waves are easily transmitted across a transducer gap in the presence of liquid, but are attenuated when the gap is dry (see Figure 1). The Model U002 & U003 uses this ultrasonic technology to perform liquid level measurement in a wide variety of process media and application conditions. Figure 1 Ultrasonic signal transmission across transducer gap A pair of piezoelectric crystals are encapsulated in epoxy at the tip of the transducer. The crystals are made of a ceramic material that vibrates at a given frequency when subjected to an applied voltage. The transmit crystal converts the applied voltage from the electronics into an ultrasonic signal. When liquid is present in the gap, the receive crystal is able to sense the ultrasonic signal from the transmit crystal and convert it back to an electrical signal. This signal is sent to the electronics to indicate the presence of liquid in the transducer gap. When there is no liquid present, the ultrasonic signal is attenuated and is not detected by the receive crystal. 1.3 Getting Started Model U002 & U003 is extremely compact level switches with electronics completely potted in an extension piece directly above the stainless steel transducer. The 12" (305 mm) long 18 AWG flying lead wires are typically terminated either inside conduit or a customer supplied junction box. No special tools are required to perform installation. Ultrasonic Level Switches 1

2.0 Installation 2.1 Unpacking Unpack the instrument carefully. Inspect all units for damage. Report any concealed damage to carrier within 24 hours. Check the contents of the packing slip and purchase order. Check and record the serial number for future reference when ordering parts. serial number 2.2 Electrostatic Discharge (ESD) Handling Procedure All Innovative Solutions electronic instruments are manufactured to the highest quality standards. These instruments use electronic components that may be damaged by static electricity present in most work environments. Make sure that all electrical connections are completely made and none are partial or floating. Ground all equipment to a good, earth ground. 2.3 Mounting Model U002 & U003 level switches may be mounted in a variety of positions as shown in Figures 2 through 5. Proper orientation of the transducer gap will facilitate maximum performance in difficult applications. When the switch is mounted horizontally, the transducer gap must be turned vertical to allow proper drainage of liquid out of the gap. The wrench flats on the mounting nut are aligned with the transducer gap; therefore, proper transducer mounting can be achieved by aligning the mounting nut flats in a vertical orientation. See Figure 4. Figure 2 Typical Mounting Orientations When installed in a nozzle or pipe, the transducer gap must extend into the tank at least one inch beyond the inside tank wall. Refer to Figure 5. Screw transducer into the opening using a wrench on the transducer mounting nut flats. If flanged, bolt unit to mating flange with proper gasket. Use thread tape or suitable pipe compound on the threads. Do not over-tighten. 2 Ultrasonic Level Switches

2.4 Wiring 2.4.1 Model U003 (Relay Output) Wiring terminations for the Model U003 are shown in Figure 3. The six wires coming out of the switch are 18 AWG. These wires should be connected to field wiring that is 14 to 22 AWG. Figure 3 Model U003 Caution: Conduit should be installed onto the 3 4" NPT connection on the back of the unit. An approved seal drain fitting should be used to prevent moisture from entering the switch. All wiring, conduit, and electrical fittings must conform to local electrical codes for the location selected. Field wiring should be connected as follows: 1. Connect power wiring via the red (+) and black (-) wires. 2. Green wire should be connected to earth ground. 3. The SPDT relay is connected: Orange wire is NO Blue wire is NC Yellow wire is COM 2.4.2 Model U002 (Current Shift Output) Figure 4 Model U002 Wiring terminations for the Model U002 are shown in Figure 4. The three wires coming out of the switch are 18 AWG. These wires should be connected to field wiring that is 14 to 22 AWG. Caution: Conduit should be installed onto the 3 4" NPT connection on the back of the unit. An approved seal drain fitting should be used to prevent moisture from entering the switch. All wiring, conduit, and electrical fittings must conform to local electrical codes for the location selected. Field wiring should be connected as follows: 1. Connect power wiring via the red (+) and black (-) wires. 2. Green wire should be connected to earth ground. Figure 5 Nozzle Mounting Figure 7 Horizontal Mounting Figure 6 Vertical Mounting Ultrasonic Level Switches 3

3.0 Reference Information 3.1 Specifications 3.1.1 Physical Inches (mm) Model U002/3 with Sanitary flange Model U002/3 with 3 4" NPT Model U002/3 with ANSI Flange 3.1.2 Electrical Power Supply: 12 35 VDC Power Consumption: Less than 1 Watt Signal Output: U003 Relay Model: SPDT relay, 1 amp @ 30 VDC, 0.5 amp @ 125 VDC, 0.5 amp @150 VAC U002 Current Shift Model: Dry Gap: 8 ma (±1 ma) Wet Gap: 16 ma (±1 ma) Cabling: 12" (305 mm) flying leads of 18 AWG wires Repeatability: 0.078" (2 millimeters) Response Time: 1 2 second typical 3.1.3 Environmental Ambient Temperature: -40 to +185 F (-40 to +85 C) Process Temperature: -40 to +185 F (-40 to +85 C) Maximum Pressure: 2000 psig (138 bar) for 1" (3 cm) and 2" (5 cm) transducers 1500 psig (103 bar) for transducers longer than 2" (5 cm) Ingress Protection: NEMA 4X (IP66) Shock ANSI/ISA-S71.03 Class SA1 Vibration ANSI/ISA-S71.03 Class VC2 3.2 Replacement Parts Model U002 & U003 units have no replacement parts. A new unit must be ordered. Consult factory. 4 Ultrasonic Level Switches

3.3 Troubleshooting PROBLEM No signal with level change No change in output between wet gap or dry gap The switch is chattering ACTION Check wiring to make sure proper input voltage is supplied. Make sure liquid is filling the transducer gap. Check for dense foam on surface or dried product in the gap. Unit may not function properly if either condition exists. Check to see if transducer gap is plugged with solids. Check for dense foam in gap. Check for proper input voltage supply. Check for turbulence. Relocate switch or isolate from turbulence. Check for excessive aeration. 3.4 Model Numbers BASIC MODEL NUMBER U00W Ultrasonic Level Switch OUTPUT TYPE 2 Current Shift Output 3 Relay Output TYPE E Hazardous Locations PROCESS CONNECTIONS 08 3 4" NPT 71 1" 150# ANSI flange 72 1.5" 150# ANSI flange 73 2" 150# ANSI flange 62 1"/1.5" Tri-Clamp fitting 63 2" Tri-Clamp fitting UNIT MATERIAL 08 316 Stainless Steel CUSTOM CONFIGURATION C Custom Design CUSTOM IDENTIFICATION ZZZZ Custom Design Number U 0 0 W E X X 0 8 C Z Z Z Z Ultrasonic Level Switches Contact Factory for Actuation Length * Minimum actuation length of 2 inches 5

Notes

ASSURED QUALITY & SERVICE COST LESS Service Policy Owners of Innovative Solutions controls may request the return of a control or any part of a control for complete rebuilding or replacement. They will be rebuilt or replaced promptly. Controls returned under our service policy must be returned by Prepaid transportation. Innovative Solutions will repair or replace the control at no cost to the purchaser (or owner) other than transportation if: 1. Returned within the warranty period; and 2. The factory inspection finds the cause of the claim to be covered under the warranty. If the trouble is the result of conditions beyond our control; or, is NOT covered by the warranty, there will be charges for labor and the parts required to rebuild or replace the equipment. In some cases it may be expedient to ship replacement parts; or, in extreme cases a complete new control, to replace the original equipment before it is returned. If this is desired, notify the factory of both the model and serial numbers of the control to be replaced. In such cases, credit for the materials returned will be determined on the basis of the applicability of our warranty. No claims for misapplication, labor, direct or consequential damage will be allowed. Return Material Procedure So that we may efficiently process any materials that are returned, it is essential that a Return Material Authorization (RMA) number be obtained from the factory, prior to the material's return. This is available through Innovative Solutions local representative or by contacting the factory. Please supply the following information: 1. Company Name 2. Description of Material 3. Serial Number 4. Reason for Return 5. Application Any unit that was used in a process must be properly cleaned in accordance with OSHA standards, before it is returned to the factory. A Material Safety Data Sheet (MSDS) must accompany material that was used in any media. All shipments returned to the factory must be by prepaid transportation. All replacements will be shipped F.O.B. factory. NOTE: See Electrostatic Discharge Handling Procedure on page 2. 60 Great Hill Road Naugatuck, CT 06770 ph: 203-729-6434 fax: 203-729-6696 www.innovativesensing.com BULLETIN: IS-9410.2 EFFECTIVE: June 2010