Flow Visualization Tunnel. Owner s Manual. May 2009

Similar documents
After installing the HEPA filters the discharge air should be monitored to ensure proper filtering efficiency. HEPA Filters

Service Manual Air Tech Second Stage

Experiment (4): Flow measurement

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

Centrifuge Operator / Service Manual

READ AND SAVE THESE INSTRUCTIONS

Induction, Cooling, & Exhaust. Aviation Maintenance Technology 111 B B

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

PHOENIX MINI-GUARDIAN

MODEL 905V OPERATING INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

5 Removal and replacement

DPL/DPL-AF SERIES PLENUM FANS OPERATION INSTRUCTIONS AND PARTS MANUAL MODELS: DPL/DPL-AF-12, 13, 15, 16, 18, 20, 22, 24, 27, 30, 33, 36 GENERAL SAFETY

EXPERIMENTAL INVESTIGATION OF THE FLOWFIELD OF DUCT FLOW WITH AN INCLINED JET INJECTION DIFFERENCE BETWEEN FLOWFIELDS WITH AND WITHOUT A GUIDE VANE

INSTALLATION INSTRUCTIONS

INSTRUCTIONS. US Patent Pending HVLP Turbine Guns

How Do Helicopters Fly? An Introduction to Rotor Aeromechanics

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS

HD 7700 Setup & Operator Manual

Installation Instructions for the EVO3 Height-Adjustable Ultimate Short Shifter

A practical investigation of the factors affecting lift produced by multi-rotor aircraft. Aaron Bonnell-Kangas

CI 3000 Coil Inserter

XS500 Load Bank. Read all instructions before using the load bank. Contents

INDEX. Preflight Inspection Pages 2-4. Start Up.. Page 5. Take Off. Page 6. Approach to Landing. Pages 7-8. Emergency Procedures..

CARENADO COPYRIGHTS. Normal & Emergency Checklist

OWNER S MANUAL REMOTE CONTROL, DUAL HEAD FOGGING SYSTEMS

Safety, Operation and Maintenance Instructions For Long & Short Nose Upholstery Air Stapler (NS10 & NS11)

Pretest Module 21 Unit 4 Single-Phase Motors

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Requires Ductwork and Blower

Reactor Startup Checklist

UV-AIRE AIR PURIFYING SYSTEM

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

PARTS TOOLS. Set Screw. Washer (2) Blue Bushing (2) Black Bushing (2) B&M Short Throw Shifter. Jam Nut Grease. Retaining Ring (2) Insert (2)

PHOENIX GUARDIAN H. E. P. A. SYSTEM

NEC 2011 Code Changes

Complete HVAC Capability

Firehawk Responder Second Stage Regulator

CHAPTER 21 ENVIRONMENT CONTROL. Section Title Page

Hydro-wind Education Kit ASSEMBLY GUIDE

Breezair TBA 550 Installation Manual

VANEAXIAL & TUBEAXIAL FANS

Part # Regulator Rebuild Kit for SuperFlow and SuperFlow 350 Regulators

Series Roll Seal

KEEP FOR FUTURE REFERENCE DC VACUUM BACK-UP SYSTEM READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT

Motor/Drive Housing and Motor Fan Replacement Kits

Chapter 11: Flow over bodies. Lift and drag

1. CONDITIONS FOR USE 2. SAFETY

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

WHIRLWIND. Owner s Manual 375RV Series (Rev ) Model: 375RV Serial Number: 375RV- Manufacture Date: A V I A T I O N WHIRL WIND AVIATION

Maintenance Information

Owners Manual. Table of Contents 4.1. INTRODUCTION SPEEDS FOR NORMAL OPERATION CHECKLIST & PROCEDURES 4

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

Tube Topics. (a) (b) (c) Figure 1. The interior of a tetrode: (a) mesh filament, (b) control grid (c) screen grid

I n s t r u c t i o n M a n u a l. Instruction Manual SPECIFICATION

Introduction to Johnson Controls Dampers

Typical Fuel Systems - An Overview

Service Manual Air Plus Second Stage

Flow Behavior and Friction Factor. in Internally Grooved Pipe Wall

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

Cylinder head/gasket, replacing

GRAVITY FEED SPRAY GUN & CUP SPECIFICATIONS. Operating Instructions Warning Information Parts Breakdown. Fluid Orifice mm. Air Inlet:...

MODEL ELC-12/40-CVM-D BATTERY CHARGER

ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL

Keeping You Cool Under Pressure

GENERAL AND PLANNING INFORMATION

Bench Top Tube Bender

Foss Electric Milko-Scope II Meter Manual

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:


BASIC CONNECTION PRINCIPLE

SAFARI Helicopter Flight Control Rigging Manual Revision 9 4/3/2010 CHR International Inc.

Oreck Magnesium Series Service Manual. The Oreck Manufacturing Company

AMD-33 Air Measuring Station with VCD-33 Control Damper

NSGV EVE-ER I, O, & M MANUAL

RECOMMENDED MOTOR AND BATTERY SET UP

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

ENGINE STARTING PERFORMANCE EVALUATION AT STATIC STATE CONDITIONS USING SUPERSONIC AIR INTAKE

SECTION AXIAL HVAC FANS

WEBER CARBURETOR TROUBLESHOOTING GUIDE

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

Norfolk & Western Y6b Mallet

Norfolk & Western Y6a Mallet

Honda CRV Oil Change

KHR Series Regulators

PRODUCT OPERATING MANUAL

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.

Safety Instructions, Installation & Operator s Manual For

Applied Fluid Mechanics

WHIRLWIND. Owner s Manual Series (Rev ) Serial Number: Manufacture Date: A V I A T I O N Model: WHIRL WIND AVIATION

AMD-42V Air Measuring Station with VCD-42V Control Damper

Transcription:

Flow Visualization Tunnel May 2009 AEROLAB LLC 2009

Contents Introduction... 3 Description... 3 Warnings / Precautions... 4 Tunnel Overview... 5 Main Control Panel... 6 Basic Operation... 8 Auxiliary Blower and Throttle Valve Operation... 9 Delta and Rectangular Wing Model Installation... 10 Airfoil and Venturi Model Installation... 11 Spin Model Installation... 12 Model Operation and Experiment Suggestions... 13 Airfoil w/ Blown Flap... 13 Airfoil w/ Vacuum Holes... 13 Airfoil for Student Experimentation... 14 Airfoil w/ Tangential Blowing Slots... 14 Venturi... 14 Circular Cylinder (Spin Model)... 15 Delta Wing... 15 Rectangular Wing... 15 www.aerolab.com 2 301-776-6585

Introduction AEROLAB Flow Visualization Tunnel The shape of an object moving through a fluid has a major influence on the way the fluid reacts. Using the AEROLAB Flow Visualization Tunnel (FVT), students can see firsthand the flow of air over objects such as airfoils, wings, cylinders and other aerodynamic shapes. While the AEROLAB Flow Visualization Tunnel is great for group demonstrations, it s also intended for hands-on student experimentation. Students can change pitch angles, deflect flaps, rotate circular cylinders and apply vacuum or blowing to improve aerodynamic performance. Hands-on activities motivate learners because the effects of their adjustments are immediate and obvious. Description wind tunnel - Length: 53 inches (1.35m) Height: 28.5 inches (72cm) Width: 17 inches (43cm) cabinet - Height: 37 inches (94cm) Width: 45.5 inches (1.16m) Depth: 24 inches (61cm) Power requirements: 115 VAC, 60 Hz, minimum 15 Amp circuit, international use requires a transformer Flow visualization tunnels, in particular, require exceptionally smooth, steady airflow. This quality of airflow is aerodynamically termed laminar flow. Laminar flow contains no eddies or other types of turbulence. Turbulence is undesirable because it diffuses the injected water vapor lines causing them to lose definition and appear fuzzy. In general, laminar flow is not easy to generate and difficult to maintain. Two factors promote laminar flow: a carefully designed inlet bell mouth (known as the contraction) and an effective honeycomb flow straightener. The AEROLAB Flow Visualization Tunnel design includes a large-area-ratio (inlet to outlet) contraction and engineered aluminum honeycomb. The honeycomb provides approximately 7700 hexagonal channels, 7 inches in length and 1/8 inch across flats (Aspect Ratio 56). Honeycomb is also employed at the exit of the model area to ensure laminar flow. Vaporized water (created by an ultrasonic atomizer) is introduced in streaklines spaced 0.25 inches (6.35mm) apart through a special rake. The rake is located near the exit of www.aerolab.com 3 301-776-6585

the contraction. The ultrasonic atomizer is housed in an enclosure directly below the smoke rake. During prolonged use, water vapor condenses in the vapor line. To remove the water droplets and restore vapor flow, the control panel has a purge button. Airflow is generated by a centrifugal blower downstream of the test section. Airspeed is infinitely controllable through a knob on the main control panel. The knob is attached to a flap which throttles the flow out of the blower. The flow visualization tunnel is fabricated with an aluminum frame consisting of top and bottom plates. Suitably cross-braced, it stands on aluminum legs. The top and bottom plates have machine-milled grooves which retain the acrylic sides. One side of the converging section, the contraction, and the test section are enclosed with a single piece of clear acrylic. This construction enhances the appearance and makes visible the entire vapor rake and streamline flow pattern. The side walls downstream of the test section are formed of opaque blue acrylic to harmonize with the anodized aluminum. The rear wall of the test section is finished in non-reflective black to enhance viewing and photography. A removable visor is added to diminish the effect of exterior light. The atomizer begins to function virtually immediately, so warm-up time is not required. Models are mounted by opening the hinged back panel and inserting the model stem through the angle-of-attack mechanism. Air under positive or negative pressure can be piped from the auxiliary blower to models. The rotating cylinder model can be rotated at a fixed speed. Fluorescent lights are mounted both above and below the test section to illuminate the model and the streaklines. Warnings / Precautions - The aluminum honeycomb at the entrance to the tunnel is fragile and sharp. If mishandled, it will bend, deform and possibly cut skin. Avoid contact with the honeycomb. Bent honeycomb can be straightened with a pair of small needle nose pliers and patience. - The atomizer reservoir will get HOT in approximately 15 minutes of continuous operation. Turn off the tunnel and allow the reservoir to cool. Avoid contact with the reservoir. - The atomizer requires normal tap water. Do not use distilled water. - The water level in the atomizer reservoir is critical to good operation too high and vapor will not be produced, too low and the atomizer will automatically turn off (no vapor will be produced). - Thoroughly clean up any spilled water and dry hands before connecting the FTV to power. www.aerolab.com 4 301-776-6585

Tunnel Overview AEROLAB Flow Visualization Tunnel Honeycomb flow straightener Inlet Contraction Test Section Outlet Diffuser Main Control Panel Vapor Rake Airspeed Control Atomizer Reservoir Front View Auxiliary Blower Model Mount Spin Motor Outlet Aux. Blower Throttle Valve Back View www.aerolab.com 5 301-776-6585

Main Control Panel AEROLAB Flow Visualization Tunnel Main Control Panel The POWER button is the main switch for the tunnel. Nothing can operate unless this switch is engaged. The air compressor (located inside the cabinet) will run for a short period of time when this button is activated. The compressor is audible. The FAN button activates the wind tunnel fan. The SMOKE button activates the atomizer. www.aerolab.com 6 301-776-6585

The SPIN CYLINDER button activates the cylinder electric motor. The VACUUM button activates the auxiliary blower. The blower provides pressurized air and/or vacuum to the vacuum/blowing models. The PURGE button provides a short blast of air to the vapor rake. This blast of air clears the rake of collected water droplets. The LIGHTS button activates the lights located above the below the test model. The AIR SPEED knob changes the airspeed through the wind tunnel. Turn the knob clockwise to slow the flow or counterclockwise to speed it up. www.aerolab.com 7 301-776-6585

Basic Operation AEROLAB Flow Visualization Tunnel WARNING Never mix water and electricity. It can cause serious injury or death. Never connect or disconnect the FVT to power with wet hands or spilled water in the area. 1) With the FVT unplugged from power, check the reservoir water level. A sight glass is located on the side of the reservoir. If no water is needed, skip to step 3. 2) To fill the reservoir, lift the springloaded reservoir cap and slip in the supplied funnel. Add normal tap water while watching the sight glass. Marks on the sight glass indicate upper and lower water levels. Remove the funnel. 3) Connect the FVT to power. 4) The main control panel (see page 6) is located on the front of the tunnel. Press the power button to enable the tunnel. 5) Install / prepare the test model (see page 10) and close / latch the back access door. 6) Press the FAN button to start airflow. 7) Press the SMOKE button. NOTE the atomizer reservoir will get HOT in approximately 15 minutes of continuous use. As such, turn off the atomizer when it is not needed, for example, during a model change. If the reservoir gets hot to the touch, it must be allowed to cool down or damage to the atomizer could result. Water vapor streaklines will become visible in a few seconds. 8) Press the LIGHTS button to activate the lights. 9) The AIR SPEED knob can be adjusted as preferred. Turn the knob clockwise to slow down the airspeed or counterclockwise to speed up the airspeed. www.aerolab.com 8 301-776-6585

Note The airspeed knob has an effect on water vapor density; at higher speeds the water vapor will be thinner than at slower speeds. 10) From time to time, water droplets will collect in the vapor rake tubes. Momentarily, press the PURGE button to blow the droplets free of the vapor rake. This purging may need to be done two or three times for best results. 11) The FVT can be completely turned off with the POWER button. However, it would be best to make certain the VACUUM and SPIN CYLINDER buttons are off before using the POWER button to avoid potential damage to the motor and auxiliary blower at restart. Auxiliary Blower and Throttle Valve Operation The auxiliary blower is located on the back side of the FVT. It is activated by means of the VACUUM button on the main control panel (see page 6). The blower is used for both vacuum and blowing. The conical fitting is a press-and-twist fit. set for vacuum set for blowing The throttle valve is located on the back frame member and is used to vary the vacuum and blowing intensity to the airfoil models. It can easily be adjusted from www.aerolab.com 9 301-776-6585

the front of the FVT for precise settings. The valve is adjustable from fully-closed to fully-open in 90 of travel. Auxiliary Blower Throttle Valve Delta and Rectangular Wing Model Installation Note Although the AEROLAB Flow Visualization Tunnel is designed to give generations of service, care should be taken to avoid damage. Never force a model into the holder. If it does not go into position easily, investigate the situation before force is applied. 1) Identify the delta wing and flat plate model mounting post (shown to the left). 2) Identify the airfoil and wing model mount (shown to the left). Make certain it is installed in the back access door. To do so, press the narrow end of the model mount into the hole in the back access door. The mount has springloaded pins used to hold it in place. 3) Unlatch the back access door and slide the post through the model holder. www.aerolab.com 10 301-776-6585

4) While holding the post on the inside face of the back access door, install the locking nut to finger-tightness. 5) Slide the delta or rectangular wing model onto the mounting post. 6) Adjust the pitch angle as desired. 7) Turn the model mount in the back access door to align the model with the flow (the yaw angle). Airfoil and Venturi Model Installation 1) Unlatch and open the back access door. 2) Note the brass tube and alignment pin located on the side of each model. Note the two holes on the model holder. Slide the brass tube into the model holder and align the pin. Slide the model onto holder until the alignment pin engages with the pin hole. www.aerolab.com 11 301-776-6585

3) For blowing / vacuum models, hold the model in one hand while pressing the auxiliary blower tube onto the brass model tube. Note The auxiliary blower tube should be pressed on only SLIGHTLY. Otherwise, removal will be difficult. 4) Close and latch the back access door. Spin Model Installation 1) Remove the airfoil and wing model mount. To do so, gently pull the mount back away from the tunnel while rocking side to side. 2) Install the spin model holder into the back access door as you would the airfoil and wing model mount. It, too, has spring-loaded pins used to hold it in place. 3) Slide the cylinder model onto the square motor shaft. www.aerolab.com 12 301-776-6585

4) While holding the cylinder, thread the lock nut onto the motor shaft. This will prevent the cylinder from coming loose and scratching the tunnel window. 5) Close and latch the back access door. Model Operation and Experiment Suggestions Note - Because the airfoil models span the test area (they go from wall to wall), air is forced to move in only two dimensions (it cannot flow sideways to go around the ends of the models). This type of flow is termed two-dimensional. Airfoil w/ Blown Flap Airfoil w/ Vacuum Holes The Flap Model is intended to be used with and without blowing note the slot just in front of the flap hinge on the top of the airfoil. The flap can be adjusted down or up. The model demonstrates the Coanda Effect when used with blowing. The Coanda Effect is used to increase high angle-of-attack performance. The intensity of the blowing should be adjusted to the lowest possible setting to achieve the desired result. The Boeing C-17 Globemaster III employs blown flaps to increase performance. Vacuum applied to the top surface of a wing can increase high angle-of-attack performance. The Airfoil with Vacuum Holes serves to demonstrate this phenomenon. The intensity of the vacuum should be adjusted to the lowest possible setting to achieve the desired result. As an added experiment, use cellophane tape to partially or fully close holes and observe the result. www.aerolab.com 13 301-776-6585

Airfoil for Student Experimentation A large chamber has been cut into the top surface of the student experimentation airfoil. The chamber can be covered with tape or paper and holes or slots can be opened to experiment with the application of blowing or vacuum. Airfoil w/ Tangential Blowing Slots Venturi Similar to the Airfoil w/ Blown Flap, this model employs blowing (the Coanda Effect) to increase performance. Visible on the top surface, there are two slots. These slots have been designed such that the pressurized air is directed back and tangential (parallel) to the upper surface. Operate the model with and without blowing. Adjust the blowing intensity to the lowest possible setting to achieve the desired result. As an added experiment, use cellophane tape to partially or fully close slots and observe the result. The Venturi model serves to demonstrate the effect of a converging duct on moving air. Observe the streaklines as they pass through the model. Change the pitch angle of the model and observe the streaklines. www.aerolab.com 14 301-776-6585

Circular Cylinder (Spin Model) AEROLAB Flow Visualization Tunnel The Circular Cylinder serves to demonstrate the Magnus Effect. Operate the tunnel with and without the cylinder spinning. Note the direction of the spin and the effect on the streaklines. By observing the vapor lines, what is happening and why? Note The direction of rotation can be changed by switching the leads on the motor power supply located in the lower cabinet. Note - The delta and rectangular wing models allow air to flow around them just as it would on an actual aircraft. This is termed three-dimensional flow because the air is allowed to move in all three dimensions. Delta Wing The delta wing model serves to demonstrate the vortices generated by such a wing design. The wing s angle of attack can be adjusted by gently twisting the wing on the mounting post. Also, change the yaw, or side-slip, angle of the model by means of the model mount and observe the result. Discuss the advantages of a delta-wing aircraft. What is the benefit of the obvious vortices generated on the top of the wing? Rectangular Wing The rectangular wing model serves to demonstrate the vortices generated by such a wing design. The wing s angle of attack can be adjusted by gently twisting the wing on the mounting post. Discuss the vortices How do they affect the performance of the wing? www.aerolab.com 15 301-776-6585