OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

Similar documents
4-20mA DC PROCESS CLAMP METER

DIGITAL EARTH RESISTANCE Model KM 2030

SOIL RESISTIVITY TESTER

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

RTD CALIBRATOR Mode KM-CAL-720

1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING. Model 1154TMF

ANALOG INSULATION RESISTANCE TESTER

HIGH VOLTAGE PROXIMITY DETECTOR

TEMPERATURE CALIBRATOR Model KM-CAL-801

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

DIGITAL 4 WIRE EARTH RESISTANCE TESTER

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Tachometer. English. Users Manual

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Infrared Thermocouple Probe

i400s Calibration Information Introduction

Calibration Manual. Detachable Jaw True-rms Clamp Meter

Temperature Calibrator

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:


TMD90A Dual Input Digital Thermometer

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

365 Detachable Jaw True-rms Clamp Meter

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

Users Manual. MegOhmMeter

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

362 Clamp Meter. Users Manual

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

P5510. Users Manual. Pneumatic Comparison Test Pump

Visit us at

Low Amp Probe EETA308A

373 Clamp Meter. Users Manual

Dawson DDM190D. Digital Multimeter User s Manual

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

362 Clamp Meter. Users Manual

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

IAQ-CALC TM Indoor Air Quality Meter

323/324/325 Clamp Meter

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

PY-11 Voltage & Continuity Tester

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

716 Pressure Calibrator

719 Series. Pressure Calibrator with Electric Pump. Product Overview (E)

This manual covers the following model:

P5514, P5514-V & P5514-EP Hydraulic Comparison Test Pump

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

THWD-3 and TH-3 Relative Humidity and Temperature Meters

Model Battery Powered Milliohm Meter

KMP Insulation-Continuity Tester. Users Manual

80PK-2A Type K Immersion Probe

i3000s/i2000 Flex AC Current Probe

IAQ-CALC TM Indoor Air Quality Meter

302+/303 Clamp Meter. Users Manual

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

TIME-10 Process Control Stopwatch

Dawson DSM170 Multi-Function Moisture Meter User s Manual

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

DT304. Digital Temperature Logger INSTRUCTION MANUAL

Indoor Air Quality Meter

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

50407 / DUAL INDEPENDENT FOOTWEAR AND WRIST STRAP TESTER

Users Manual. Phase Rotation Indicator

Operator Instructions for Tension Links

INSP-3 Wiring Inspection Tester

Dawson DAN100. Analog Multimeter User s Manual

Table of Contents Title Page No.

712 RTD Calibrator. Instruction Sheet. Introduction

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

OPERATING INSTRUCTIONS

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

Stone Technologies Corporation Model 4110Dual Mode Battery Analyzer Technical Manual Contents

PK-8270-X/PK-8370-X. Lines and Fittings Kit. Instructions. Introduction. How to Contact Fluke Calibration

KMP7010. Ground Resistance Tester. Users Manual

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

A Member of the. Integrated Metering Technologies

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

MoistureMatch A next generation grain tester

718 30G/100G. Users Manual. Pressure Calibrator. 99 Washington Street Melrose, MA Phone Toll Free

TACH-10 Contact / Non-Contact Tachometer

MegOhmMeter. Users Manual

Users Manual. Airflow Meter

Phase Sequence Tester

User Guide. Model Insulation Tester / Megohmmeter. Introduction

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

Delmhorst Instrument Co. Model HT-3000 Thermo-Hygrometer. Owners Manual

User's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable

3000RS PRECISION RESISTANCE STANDARD 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS

Transcription:

LIST OF PRODUCTS * Digital Multimeter * Digital AC & AC/DC Clampmeter * AC Clamp Adaptor * AC/DC Current Adaptor * Thermo Anemometer * Thermo Hygrometer * Distance Meter * Digital Lux Meter * Network Cable Tester * Power Factor Regulator * Earth Resistance Tester * Digital Panel Meters * DC Power Supplies * High Voltage Detector * Calibrators * Gas Analysers * Frequency Counter * Function Generator * Phasing Sticks * Battery Tester * Waterproof Pen Testers * Solar Power Meter * EMF Detector * Wood, Paper & Grain Moisture Meter * Transistorised Electronic Analog & Digital Insulation Resistance Testers(upto 10 KV) * Digital Sound Level Meter & Sound Level Calibrator * Digital contact & Non-contact Type Tachometer * Digital Non-contact (infrared) Thermometer * Maximum Demand Controller/Digital Power Meter * Digital Hand Held Temperature Indicators MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 OPERATION MANUAL

TABLE OF CONTENTS MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 TITLE PAGE Introduction...1 Features...2 Product Description...3 Electrical Specification...4 Operation...4 Measurement...6 Battery replacement...7 Test Certificate...8 Warranty...9

1. INTRODUCTION The KM 071 Milliamp Process Clampmeter is a hand-held battery operated Clampmeter that measures 4-20mA DC without breaking the electrical circuit. Unlike conventional clampmeters this meter features a small jaw that easy to reach any place there is a cable carrying with a current. This meter takes a magnetic modulated technology, and it can rach excellent sensitivity with great anti Earth Magnetic Field ability. 2. FEATURES DC ma measurement (4-20mA); 0-40mA Electronic zero Jaw Size : 5mm Percentage span (0-100%) Data Hold Display backlight Measurement spotlight LED Operating Temperature : -10 C to 50 C Storage Temperature : -25 C to 70 C Operating Humidity : <90% @ <30 C <75% @ 30 C to 50 C Power Supply : 9V Alkaline, IEC LR6 Dimension : 59(H) X 38(W) x 212(L)mm Weight : 260g (including battery) KUSAM-MECO 1 July 2011 KUSAM-MECO 2 July 2011

3. PRODUCT DESCRIPTION 1 2 3 5 4 6 7 1. Transformer jaw : Pick up the DC flowing through the conductor. 2. Spotlight button : Turn the Spotlight on or off. 3. Zero button : Removes offset and zeros the display. 4. Backlight button : Turn on or off the backlight of LCD. 5. Power Switch : Turn on or off the meter. 6. HOLD button : Captures and holds the current reading. 7. LCD : Display the current value and percentage. 4. ELECTRICAL SPECIFICATIONS : Current Ranges : ± 40.00mA Resolution : 0.01mA Accuracy : ±0.5% of reading ± 5 digits Maximum Reading : ±40.00mA Error by Earth Magnetic Field : < ± 0.20mA 5. OPERATION & MEASUREMENT : The following sections give more detail about the Meter s features. 5.1 Operation The percentage Span feature displays the span for 4 to 20mA loops. 20 ma 16 ma 12 ma 8 ma 100% 75 % 50 % 25 % 5.2 Zero Adjustment 4 ma 3.6 ma 3.2 ma 2 ma 0 % -2.5 % -5.0 % -12.5% Before taking each measurement, press the ZERO button to zero the display by removing DC offset. Make sure the clamp jaws are closed and no current is flowing through them. 5.3 Backlight Press the backlight button to turn the backlight on or off. KUSAM-MECO 3 July 2011 4

5.4 Measurement Spotlight LED The measurement Spotlight LED helps to quickly find ma signal wires. Press the Spotlight button to turn the Spotlight on or off. 5.5 Display HOLD Warning To avoid electric shock, when Display HOLD is activated, the display will not change when a different current is applied. Press the HOLD button to activate Display Hold mode. The symbol DH are displayed and the Meter freezes the display. To exit & return to normal operation, press the HOLD button a second time. Warning The Clampmeter is not for use on non-insulated conductors. Measurements can be taken with the clamp approach into any position. For accurate measurements : Always zero the Meter prior to taking measurements. Zero the Meter as close to the measurement Note : To reduce magnetic influences, zero the Meter in the same position or jaw direction that is used for the measurement. 6. MEASUREMENT With the clamp disconnected from any conductor, press the power switch to turn the meter ON. Then, you might wait for about 5 seconds. Clamp the jaw around the conductor under test. The meter displays the measured conductor current. A positive reading indicates current flowing in the direction of the arrow on the clamp. A negative reading indicates current flowing in the opposite direction of the arrow. Do not clamp more than one wire. Currents cancel and no results are returned. The small secondary display shows the reading in terms of percentage span. source position as possible. Make sure the clamp is free of contamination. 5 6

7. BATTERY REPLACEMENT WARNING To avoid false readings, that could lead to possible electric shock or personal injury, replace the battery as soon as the low battery indicator appears. To replace the battery : 1. Turn the Meter off 2. Use a flat head screwdriver to loosen the battery compartment door screw, and remove the door from the case bottom. 3. Remove the battery. 4. Replace the battery with a new 9V battery. 5. Reattach the battery compartment door to the case bottom and tighten the screw. MUMBAI TEST CERTIFICATE MILLIAMP PROCESS CLAMPMETER This Test Certificate warrantees that the product has been inspected and tested in accordance with the published specifications. The instrument has been calibrated by using equipment which has already been calibrated to standards traceable to national standards. MODEL NO. KM 071 SERIAL NO. DATE: ISO 9001 REGISTERED QC KUSAM-MECO PASS 7 8

WARRANTY Each KUSAM-MECO product is warranted to be free from defects in material and workmanship under normal use & service. The warranty period is one year (12 months) and begins from the date of despatch of goods. In case any defect occurs in functioning of the instrument, under proper use, within the warranty period, the same will be rectified by us free of charges, provided the to and fro freight charges are borne by you. This warranty extends only to the original buyer or end-user customer of a KUSAM-MECO authorized dealer. This warranty does not apply for damaged Ic s, fuses, burnt PCB s, disposable batteries, carrying case, test leads, or to any product which in KUSAM-MECO s opinion, has been misused, altered, neglected, contaminated or damaged by accident or abnormal conditions of operation or handling. KUSAM-MECO authorized dealer shall extend this warranty on new and unused products to enduser customers only but have no authority to extend a greater or different warranty on behalf of KUSAM-MECO. 9 KUSAM-MECO s warranty obligation is limited, at option, free of charge repair, or replacement of a defective product which is returned to a KUSAM-MECO authorized service center within the warranty period. THIS WARRANTY IS BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. KUSAM-MECO SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE WHATSOEVER. All transaction are subject to Mumbai Jurisdiction. G 17,Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct : (022) 24156638 Tel. : (022) 24124540, 24181649. Fax : (022) 24149659 Email : kusam_meco@vsnl.net Website : www.kusamelectrical.com www.kusam-meco.co.in 10