Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Similar documents
Controls. CONTACTORS CWB Line (up to 40A)

CWM_N NEMA Rated Contactors

CI-TI Contactors and motor starters Types CI 61 - CI 98

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

AF40... AF96 3-pole contactors Technical data

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Industrial contactors CTX-1

Thermal Overload Relays - WEG RW Series, 2 Pole

ASL09..S 3-pole Contactors - Spring Terminals

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

W Datasheet: DIN Rail Contactors, series AMPARO

Low Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Industrial Contactors CTX 3 3P 185A - 800A

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Modular contactor for installation into distribution boards

TAE pole Contactors

Application Mini Contactors for Motors and Resistive Loads

Short form catalogue. Motor protection & control

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Modular contactors and relays

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MS25 59 MS RI RI RV 60, RV 120 RS 76 CDB3X 77 Surface Mounted (INO) and Flush Munted (IPO) Compact Distribution Boards 78

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

AE 9... AE 40 Contactors NE... Contactor Relays

Electronic overload relays EF205 and EF370

Mini Contactors CI 4-

Electronic overload relay EF65, EF96 and EF146

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

For Info: Phone: Fax:

Contactor Types CI 61-98

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Meta Solution. Contactors and Overload relays

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

4 - Miniature controls

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Essential equipment for all your requirements

Technical Information

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

CI-TI Contactors and Motor Starters Type CI 6-50

B Mini Contactor V Hz

Star Series Motor protection & control

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Application Mini Contactors for Motors and Resistive Loads

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Description. Positive safety relays

Mini contactors B6, BC6 with 3 pole

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Switches Unlimited Phone: * Fax:

Thermal overload relay TF140DU and TF140DU-V1000

Technical data for manual motor starters Type MS325

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Quick selection table

Thermal overload relay TF65 and TF96

Page 2-4 Page 2-8. Page Page 2-13

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories


D509E. Manual Motor - Starters

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE

BC Mini Contactor VDC

Micro Contactor MA Series

3 - Protection components Motor circuit-breakers

Technical Information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004

Bulletin 193-T1 Bimetallic Overload Relays

Bulletin 100-D IEC Contactors

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

Technical Information

BETA Switching Switches and Light Indicators

SIRIUS 3RU2 Thermal Overload Relays

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Transcription:

Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line

2 Contactores Compactos CWC0

Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors from 9 up to 250 A (AC-3) - AC Coil 9 Three-Pole Contactors from 0 up to 105 A (AC-3) - DC Coil 10 Three-Pole Contactors from 112 up to 800 A (AC-3) - Coil with Electronic Module AC/DC 11 Four-Pole Contactors - AC Coil or Coil with Electronic Module AC/DC 12 Accessories 13 Reversing Starters 16 Star-Delta Starters 17 Spare Parts 18 Technical Data 19 Dimensions (mm) 39

CWM Contactors - Presentation The CWM general-purpose contactor line has been designed taking into consideration industrial duty and reliability. Rated for inductive loads up to 800 A or 0 kw @ 380/00 V, WEG can offer the most suitable contactor for your application. CWM contactors allow total panel space optimization, with only a few compact frame sizes from to 0 kw @ 00/15 V. Reducing inventory is simple with CWM common accessories. For example, side-mounted auxiliary contact blocks are the same from 9 to 300 A (AC-3) @ 0 V. Designed for extended mechanical and electrical life, dependable switching in even the most heavy-duty applications can be achieved. No matter how demanding the application, all WEG contactors are tested and approved to be used under Type 1 and Type 2 short-circuit coordination. Ensuring global acceptance, all components conform to UL 508 (USA and Canada), IEC 6097 and CE. All WEG contactors are manufactured to assure the highest quality manufacturing processes and component materials. This way, WEG offers reliable solutions for low-voltage applications in electric panel assemblers, OEMs, distributors and end users. Contactors - CWM Line

CWM Contactors from 9 up to 0 A (AC-3) - Accessories Overview 7 8 1 5 5 1 6 8 7 2 5 2 5 6 8 7 3 5 3 5 6 1 - Contactors CWM9...18 2 - Contactors CWM25 3 - Contactors CWM32/0 - Front mounting auxiliary contact block BCXMF 5 - Side mounting auxiliary contact block BCXML 6 - Mechanical interlock block BLIM 7 - Easy connection busbar 8 - Surge suppressor blocks BAM Contactors - CWM Line 5

CWM Contactors from 50 up to 105 A (AC-3) - Accessories Overview 7 6 1 1 5 3 7 6 2 2 5 3 1 - Contactors CWM50...80 2 - Contactors CWM95/105 3 - Front mounting auxiliary contact block BCXMF - Side mounting auxiliary contact block BCXML 5 - Mechanical interlock block BLIM 6 - Easy connection busbar 7 - Surge suppressor blocks BAM 6 Contactors - CWM Line

CWM Contactors from 112 up to 300 A (AC-3) - Accessories Overview 7 1 10 1 5 7 8 10 2 6 11 2 5 8 9 11 3 6 12 3 5 9 12 1 - Contactors CWM112/150 2 - Contactors CWM180 3 - Contactors CWM250/300 - Side mounting auxiliary contact block BCXML 5 - Mechanical interlock BLIM112-300 6 - Surge suppressor block BAMV 7 - Terminal cover BMP CWM150 8 - Terminal cover BMP CWM180 9 - Terminal cover BMP CWM300 10 - TB150 terminal block for CWM112-150 11 - TB180 terminal block for CWM180 12 - TB300 terminal block for CWM250-300 Contactors - CWM Line 7

CWM Contactors from 00 up to 800 A (AC-3) - Accessories Overview 6 8 3 1 1 9 5 3 2 2 7 1 - Contactor CWM00 2 - Contactors CWM500...800 3 - Auxiliary contacts block BCXMRL CWM800 - Mechanical interlock BLIM CWM00 5 - Mechanical interlock BLIM CWM800 6 - Terminal cover BMP CWM00 7 - Terminal cover BMP CWM800 8 - Lugs BMJ CWM00 9 - Lugs BMJ CWM800 8 Contactors - CWM Line

CWM Contactors - Selection Table Three-Pole Contactors from 9 up to 250 A (AC-3) - AC Coil 3) Rated Conv. Max. rated operational power of three-phase Auxiliary contacts Auxiliary contact blocks operational thermal motors 50/60 Hz 1) per contactor separately delivered Weight current current Reference code 220 V 380 V 00 V 0 V 500 V 660 V 3 1 I e AC-3 I th = I e to complete with 230 V 15 V 690 V BCXMF10 BCXMF01 (U e 0 V) AC-1 voltage code 2 A A kw / HP kw / HP kw / HP kw / HP kw / HP kw / HP NO NC NO NC kg 1 0 Built-in - CWM9-10-30 9 25 2.2 / 3 / 5 / 5.5 / 6.5 / 6 5.5 / 7.5 0 1 - Built-in CWM9-01-30 1 1 Built-in 1 cwm9-11-30 0.360 2 2 1 2 CWM9-22-30 1 0 Built-in - CWM12-10-30 12 25 3 / 5.5 / 7.5 5.5 / 7.5 5.5 / 7.5 5.5 / 7.5 7.5 / 10 0 1 - Built-in CWM12-01-30 1 1 Built-in 1 CWM12-11-30 0.360 2 2 1 2 CWM12-22-30 1 0 Built-in - CWM18-10-30 18 32.5 / 6 7.5 / 10 7.5 / 10 9.2 / 12.5 9.2 / 12.5 11 / 15 0 1 - Built-in CWM18-01-30 1 1 Built-in 1 CWM18-11-30 0.360 2 2 1 2 CWM18-22-30 0 0 - - CWM25-00-30 1 0 1 - CWM25-10-30 25 5 5.5 / 7.5 11 / 15 11 / 15 11 / 15 11 / 15 11 / 15 0 1-1 CWM25-01-30 0.390 1 1 1 1 CWM25-11-30 2 2 2 2 CWM25-55-30 0 0 - - CWM32-00-30 1 0 1 - CWM32-10-30 32 60 9.2 / 12.5 15 / 20 15 / 20 15 / 20 15 / 20 18.5 / 25 0 1-1 CWM32-01-30 0.620 1 1 1 1 CWM32-11-30 2 2 2 2 CWM32-22-30 0 0 - - CWM0-00-30 0 60 11 / 15 18.5 / 25 18.5 / 25 22 / 30 22 / 30 22 / 30 1 1 1 1 CWM0-11-30 0.650 2 2 2 2 CWM0-22-30 0 0 - - CWM50-00-30 50 90 15 / 20 22 / 30 22 / 30 30 / 0 30 / 0 30 / 0 1 1 1 1 CWM50-11-30 1.205 2 2 2 2 CWM50-22-30 0 0 - - CWM65-00-30 65 110 18.5 / 25 30 / 0 30 / 0 37 / 50 37 / 50 37 / 50 1 1 1 1 CWM65-11-30 1.215 2 2 2 2 CWM65-22-30 0 0 - - CWM80-00-30 80 110 22 / 30 37 / 50 5 / 60 5 / 60 5 / 60 5 / 60 1 1 1 1 CWM80-11-30 1.220 2 2 2 2 CWM80-22-30 0 0 - - CWM95-00-30 95 10 22 / 30 5 / 60 55 / 75 55 / 75 55 / 75 55 / 75 1 1 1 1 CWM95-11-30 1.525 2 2 2 2 CWM95-22-30 0 0 - - CWM105-00-30 105 10 30 / 0 55 / 75 55 / 75 55 / 75 55 / 75 55 / 75 1 1 1 1 CWM105-11-30 1.505 2 2 2 2 CWM105-22-30 112 180 30 / 0 55 / 75 55 / 75 55 / 75 55 / 75 75 / 100 2 2 - - CWM112-22-30 3.1 180 225 55 / 75 90 / 125 90 / 125 110 / 150 110 / 150 110 / 150 2 2 - - CWM180-22-30 51.0 250 350 75 / 100 132 / 175 132 / 175 150 / 200 160 / 220 160 / 220 2 2 - - CWM250-22-30 6.66 Replace with the Appropriate Coil Voltage Code 2) AC coil - 50/60 Hz Coil voltage codes D02 D07 D13 D23 D2 D25 D33 D3 D35 D36 D39 V ac - 50/60 Hz 2 8 110 220 230 20 380 00 15 0 80 Notes: 1) For 50/60 Hz three-phase, poles WEG standard motors. These values are only for reference and may change on the number of poles and motor design. 2) Other voltages available. 3) For selection of acessories, check page 13. Contactors - CWM Line 9

CWM Contactors - Selection Table Three-Pole Contactors from 0 up to 105 A (AC-3) - DC Coil )5) Rated operational current I e AC-3 (U e 0 V) Conv. thermal current I th = I e AC-1 220 V 230 V Max. rated operational power of three-phase motors 50/60 Hz 1) 380 V 00 V 15 V 0 V 500 V 660 V 690 V Auxiliary contacts per contactor 3 1 2 Auxiliary contact blocks separately delivered BCXMF10 A A kw / HP kw / HP kw / HP kw / HP kw / HP kw / HP NO NC NO NC 0 60 11 / 15 18.5 / 25 18.5 / 25 22 / 30 22 / 30 22 / 30 50 90 15 / 20 22 / 30 22 / 30 30 / 0 30 / 0 30 / 0 65 110 18.5 / 25 30 / 0 30 / 0 37 / 50 37 / 50 37 / 50 80 110 22 / 30 37 / 50 5 / 60 5 / 60 5 / 60 5 / 60 95 10 22 / 30 5 / 60 55 / 75 55 / 75 55 / 75 55 / 75 105 10 30 / 0 55 / 75 55 / 75 55 / 75 55 / 75 55 / 75 BCXMF01 Reference code to complete with voltage code 0 0 - - CWM0-00-30 1 1 1 1 CWM0-11-30 2 2 2 2 CWM0-22-30 0 0 - - CWM50-00-30 1 1 1 1 CWM50-11-30 2 2 2 2 CWM50-22-30 0 0 - - CWM65-00-30 1 1 1 1 CWM65-11-30 2 2 2 2 CWM65-22-30 0 0 - - CWM80-00-30 1 1 1 1 CWM80-11-30 2 2 2 2 CWM80-22-30 0 0 - - CWM95-00-30 1 1 1 1 CWM95-11-30 2 2 2 2 CWM95-22-30 0 0 - - CWM105-00-30 1 1 1 1 CWM105-11-30 2 2 2 2 CWM105-22-30 Weight kg 0.60 1.63 1.63 1.63 1.63 1.63 Replace with the Appropriate Coil Voltage Code 2)3) Coil voltage codes (CWM0...105) C3 C37 C0 C V dc 2-28 2-50 110-130 208-20 Notes: 1) For 50/60 Hz three-phase, poles WEG standard motors. These values are only for reference and may change on the number of poles and motor design. 2) Other voltages available. 3) Contactors CWM0-105 with DC coils do not need surge suppressor blocks. The surge suppressor is already integrated in this coil. ) For selection of acessories, check page 13. 5) For lower currents than 0 A (AC-3) use the new line CWB9...38. 10 Contactors - CWM Line

CWM Contactors - Selection Table Three-Pole Contactors from 112 up to 300 A (AC-3) - Coil with Electronic Module AC/DC Rated operational current I e AC-3 (U e 0 V) A Conv. thermal current I th = I e AC-1 A 220 V 230 V kw / HP Max. rated operational power of three-phase motors 50/60 Hz 1) 380 V 00 V 0 V 500 V 15 V kw / HP kw / HP kw / HP kw / HP 690 V kw / HP Auxiliary contacts per contactor (BCXML) 3 NO 1 2 NC Reference code to complete with voltage code 112 180 30 / 0 55 / 75 55 / 75 55 / 75 55 / 75 75 / 100 2 2 CWM112-22-30 3.12 150 225 5 / 60 75 / 100 75 / 100 90 / 125 90 / 125 110 / 150 2 2 CWM150-22-30 3.20 180 225 50 / 75 90 / 125 90 / 125 110 / 150 110 / 150 110 / 150 2 2 CWM180-22-30 5.01 250 350 75 / 100 132 / 175 132 / 175 150 / 200 160 / 220 160 / 200 2 2 CWM250-22-30 6.86 300 10 90 / 125 150 / 200 160 / 220 185 / 250 200 / 270 200 / 270 2 2 CWM300-22-30 6.73 Weight kg Replace with the Appropriate Coil Voltage Code 2) Coil voltage codes E02 E06 E07 E10 E13 E16 E21 50/60 Hz / DC 3) 2-28 V 2-50 V 60-72 V 110-130 V 208-250 V 360-15 V 30-500 V Three-Pole Contactors from 00 up to 800 A (AC-3) - Coil with Electronic Module AC/DC Rated operational current I e AC-3 (U e 0 V) A Conv. thermal current I th = I e AC-1 A 220 V 230 V Max. rated operational power of three-phase motors 50/60 Hz 1) 380 V 00 V 0 V 500 V 690 V 15 V Auxiliary contacts per contactor (BCXML) kw / HP kw / HP kw / HP kw / HP kw / HP kw / HP NO NC 3 1 2 Reference code to complete with voltage code 00 50 125 / 150 220 / 300 220 / 300 220 / 300 220 / 300 250 / 330 2 2 CWM00-22-30 9.2 500 580 150 / 200 265 / 355 265 / 355 265 / 355 265 / 355 300 / 00 2 2 CWM500-22-30 22. 630 660 190 / 250 330 / 50 330 / 50 330 / 50 330 / 50 330 / 50 2 2 CWM630-22 -30 23.2 800 900 220 / 300 0 / 600 0 / 600 0 / 600 500 / 700 500 / 700 2 2 CWM800-22 -30 23.3 Weight kg Replace with the Appropriate Coil Voltage Code 2) Coil voltage codes (CWM00) E36 D80 D81 D82 50/60 Hz / DC 3) 100-20 V ac / 100-220 V dc - - - 50/60 Hz 3) - 265-37 V 380-50 V 0-575 V Coil voltage codes (CWM500/630/800) E35 E39 D80 D81 D82 50/60 Hz / DC 3) 100-127 V ac / 100-110 V dc 200-20 V ac / 200-220 V dc - - - 50/60 Hz 3) - - 265-37 V 380-50 V 0-575 V Notes: 1) For 50/60 Hz three-phase, poles WEG standard motors. These values are only for reference and may change on the number of poles and motor design. 2) Other voltages available. 3) Surge suppressor is already integrated. Contactors - CWM Line 11

CWM Contactors - Selection Table Four-Pole Contactors from 25 to 32 A (AC-1) I e = I th (U e 690 V) θ 55 C AC-1 A 25 25 32 3 NO Number of poles Reference code to complete with voltage code 2 2 CWM9-00-22 - CWM9-00-0 2 2 CWM12-00-22 - CWM12-00-0 2 2 CWM18-00-22 - CWM18-00-0 1 2 NC Weight kg 0.360 0.360 0.360 Replace with the Appropriate Coil Voltage Code 1) AC coil - 50/60 Hz Applicable for CWC07 CWC025 models Coil voltage codes D02 D07 D13 D23 D2 D25 D33 D3 D35 D36 D39 V ac - 50/60 Hz 2 8 110 220 230 20 380 00 15 0 80 Four-Pole Contactors from 20 up to 800 A AC-1 - Coil with Electronic Module AC/DC Conv. thermal current I th (55ºC) A AC-1 current A 220 V 20 V 380 V 00 V AC-1 power 500 V 550 V 690 V Auxiliary contacts per contactor (BCXML) kw kw kw kw NO NC 3 1 2 Reference code to complete with voltage code 500 20 160 300 375 70 2 2 CWM00-22-0 9.9 630 630 25 50 560 710 2 2 CWM500-22-0 26.3 750 660 255 70 590 70 2 2 CWM630-22 -0 26.3 900 800 310 570 710 900 2 2 CWM800-22 -0 26.3 Replace with the Appropriate Coil Voltage Code 2) Coil voltage codes (CWM00) E36 D80 D81 D82 50/60 Hz / DC 3) 100-20 V ac / 100-220 V dc - - - 50/60 Hz 3) - 265-37 V 380-50 V 0-575 V Weight kg Coil voltage codes (CWM500/630/800) E35 E39 D80 D81 D82 50/60 Hz / DC 3) 100-127 V ac / 100-110 V dc 200-20 V ac / 200-220 V dc - - - 50/60 Hz 3) - - 265-37 V 380-50 V 0-575 V 12 Contactors - CWM Line

CWM Contactors - Accessories Auxiliary Contact Blocks g Terminal markings to EN 50 005 and EN 50 012 g Positive driven contacts in accordance with IEC 6097--1 resp. IEC 6097-5-1 Illustrative picture For use with Max. number of contacts/ contactor Auxiliary contacts NO NC Reference code Weight kg 1 0 BCXMF10 0 1 BCXMF01 1 1) 0 BCXMFA10 CWM9...105 / CWM9...25 0 1 2) BCXMFR01 0.015 6 / CWM32...0 1 6) 0 BCXMF10AU 8 / CWM50...105 0 1 6) BCXMF01AU 8 / CWM112...300 2 0 BCXML20 1 1 BCXML11 CWM9...300 0.050 2 0 BCXMRL20 3) 1 1 BCXMRL11 3) CWM 00...800 8 / CWM00...800 1 1 BCXML11 CWM800 BCXMRL11 CWM800 3) 0.05 Mechanical Interlock for Contactors 5) Illustrative picture For use with Reference code Weight kg CWM9...CWM105-3 or -pole BLIM9-105 BLIM.02 ) 0.050 CWM112...CWM300-3-pole BLIM112-300 0.150 CWM00-3 or -pole BLIM CWM00 0.100 CWM500...800-3-pole BLIM CWM800 15.0 CWM500...800 - -pole BLIM CWM800-P 16.0 Notes: 1) Early-make contact. 2) Late-break contact. 3) For combination of more than 2 side-mounted auxiliary contacts. ) This accessory allows mechanical and electrical interlock. 5) Can only be used with 2 contactors of the same frame. 6) Auxiliary contact block for low current levels (1 ma / 17 V). Contactors - CWM Line 13

CWM Contactors - Accessories Surge Suppressors g Connect directly to coil terminals A1 - A2 Illustrative picture For use with Voltage Circuit diagram Reference code 2-8 V 50/60 Hz BAMRC D53 CWM9...0 50-127 V 50/60 Hz BAMRC5 D55 130-250 V 50/60 Hz BAMRC6 D63 2-8 V 50/60 Hz BAMRC7 D53 CWM50...105 50-127 V 50/60 Hz BAMRC8 D55 130-250 V 50/60 Hz BAMRC9 D63 CWM112...250 2-8 V 50/60 Hz BAMRC13 D53 50-250 V 50/60 Hz BAMRC1 D56 270-380 V 50/60 Hz BAMV1 D68 CWM9...105 00-510 V 50/60 Hz BAMV2 D73 270-380 V 50/60 Hz BAMV3 D68 CWM112...250 00-510 V 50/60 Hz BAMV D73 Weight kg 0.01 Terminal Cover g Protection against touching in accordance with relating installation rules Illustrative picture For use with Description Reference code Terminal Blocks 2) Illustrative picture For use with Flexible cable Tightening torque Description Reference code CWM112/150 CWM180 CWM250/300 CWM112/150 25...70 mm² 3...2/0 AWG 50...120 mm² 1/0...250 kcmil AWG 50...150 mm² 1/0...300 kcmil AWG 1 N.m Weight kg BMP CWM150 0.10 CWM180 1 kit with 2 parts 1) BMP CWM180 0.15 CWM250/300 BMP CWM300 0.20 CWM112/150 BMP1 CWM150 0.05 CWM180 1 kit with 1 part 1) BMP1 CWM180 0.08 CWM250/300 BMP1 CWM300 0.10 CWM00 (3-pole) BMP CWM00 0.12 CWM500...800 (3-pole) BMP CWM800 0.28 1 kit with 2 parts 1) CWM00 (-pole) BMP CWM00-P 0.16 CWM500...800 (-pole) BMP CWM800-P 0.37 Weight kg TB150 0.29 1 N.m 1 unit (3-pole) TB180 0.35 20 N.m TB300 0.5 Lug Terminals Illustrative picture For use with Description Reference code Weight kg CWM00 1 kit with 3 pieces BMJ CWM00 0.95 CWM500...800 1 kit with 3 pieces BMJ CWM00 1.0 Notes: 1) Every part is a 3-phase protector. 2) For IP20 protection degree on front. 1 Contactors - CWM Line

CWM Contactors - Accessories Reversing Wiring Kits 1) Illustrative picture Rated operational current Ie AC - 3 (U e 0 V) A Maximum rated operational power of three-phase motors 50/60 Hz Contactors Reference 220-230 V 00-15 V 660-690 V code kw / HP kw / HP kw / HP K1 = K2 9 2.2 / 3 / 5 5.5 / 7.5 CWM9 12 3 / 5.5 / 7.5 7.5 / 10 CWM12 18.5 / 6 7.5 / 10 11 / 15 CWM18 25 5.5 / 7.5 11 / 15 11 / 15 CWM25 EC-RC-11 32 9.2 / 12.5 15 / 20 18.5 / 25 CWM32 0 11 / 15 18.5 / 25 22 / 30 CWM0 50 15 / 20 22 / 30 30 / 0 CWM50 65 18.5 / 25 30 / 0 37 / 50 CWM65 80 22 / 30 5 / 60 5 / 60 CWM80 Weight kg EC-R-7.5 0.033 EC-RC-18.5 EC-RC-37 0.5 A1 A2 A1 1 3 5 1 3 5 2 6 2 6 A1 A2 Star-Delta Wiring Kits 1) Illustrative picture Rated operational current Ie AC - 3 (U e 0 V) A Maximum rated operational power of three-phase motors 50/60 Hz Contactors Reference 220-230 V 00-15 V 660-690 V code kw / HP Electrical diagram kw / HP kw / HP K1 = K2 K3 25 5.5 / 7.5 11 / 15 18.5 / 25 CWM18 CWM9 32 7.5 / 10 15 / 20 18.5 / 25 CWM18 CWM12 0 7.5 / 10 18.5 / 25 22 / 30 CWM25 CWM18 50 11 / 15 22 / 30 22 / 30 CWM25 CWM18 Weight kg EC-SD-15 0.051 EC-SD-22 5 15 / 20 22 / 30 30 / 0 CWM32 CWM18 EC-SD-25 60 15 / 20 30 / 0 37 / 50 CWM0 CWM25 EC-SD-30 80 18.5 / 25 37 / 50 5 / 60 CWM50 CWM25 EC-SD-37 85 22 / 30 5 / 60 55 / 75 CWM50 CWM32 105 30 / 0 55 / 75 55 / 75 CWM65 CWM0 EC-SD-55 138 37 / 50 75 / 100 75 / 100 CWM80 CWM50 EC-SD-75 10 37 / 50 75 / 100 90 / 125 CWM95 CWM50 175 5 / 60 90 / 125 110 / 150 CWM105 CWM65 EC-SD-90 0.5 A1 1 3 5 1 3 5 A1 1 3 5 A1 A2 2 6 2 6 A2 2 6 A2 Electrical diagram 3-Pole Jumper (k3) for Star-Delta Starters Illustrative picture For use with Description Note: 1) Contactors and mechanical interlock are sold separately. CWM9...18 Reference code Weight kg SBCM9-18 0.006 CWM25 3-pole jumper to connect in parallel L1-L2-L3 SBCM25 0.006 CWM32/0 k3 contactor terminals in a star-delta starter SBCM32-0 0.015 CWM50/65 SBCM50-65 0.031 Contactors - CWM Line 15

CWM Contactors - Reversing Starters Individual Components for Reversing Starters 220-230 V kw / HP Maximum rated operational power of three-phase motors 50/60 Hz 00-15 V kw / HP 500 V kw / HP Individual components for reversing starters Contactor Contactor Spare auxiliary contacts 660-690 V K1 K2 kw / HP Type Type K1 K2 2.2 / 3 / 5.5 / 6 5.5 / 7.5 CWM9-11 CWM9-11 - - 3 / 5.5 / 7.5 5.5 / 7.5 7.5 / 10 CWM12-11 CWM12-11 - -.5 / 6 7.5 / 10 9.2 / 12.5 11 / 15 CWM18-11 CWM18-11 - - 5.5 / 7.5 11 / 15 11 / 15 11 / 15 CWM25-11 CWM25-11 - - 9.2 / 12.5 15 / 20 15 / 20 18.5 / 25 CWM32-11 CWM32-11 - - 11 / 15 18.5 / 25 22 / 30 22 / 30 CWM0-11 CWM0-11 - - 15 / 20 22 / 30 30 / 0 30 / 0 CWM50-11 CWM50-11 - - 18.5 / 25 30 / 0 37 / 50 37 / 50 CWM65-11 CWM65-11 - - 22 / 30 5 / 60 5 / 60 5 / 60 CWM80-11 CWM80-11 - - 22 / 30 55 / 75 55 / 75 55 / 75 CWM95-11 CWM95-11 - - 30 / 0 55 / 75 55 / 75 55 / 75 CWM105-11 CWM105-11 - - 30 / 0 55 / 75 55 / 75 75 / 100 CWM112-22 CWM112-22 1NO/1NC 1NO/1NC 5 / 60 75 / 100 90 / 125 110 / 150 CWM150-22 CWM150-22 1NO/1NC 1NO/1NC 55 / 75 90 / 125 110 / 150 110 / 150 CWM180-22 CWM180-22 1NO/1NC 1NO/1NC 75 / 100 132 / 175 160 / 220 160 / 220 CWM250-22 CWM250-22 1NO/1NC 1NO/1NC 90 / 125 160 / 220 200 / 270 200 / 270 CWM300-22 CWM300-22 1NO/1NC 1NO/1NC Mechanical interlock BLIM9-105 BLIM112-300 Wiring kit EC-SD... - Reversing starters 16 Contactors - CWM Line

CWM Contactors - Star-Delta Starters Individual Components for Star-Delta Starters 220-230 V kw / HP Maximum rated operational power of three-phase motors 50/60 Hz 00-15 V kw / HP 500 V kw / HP Main contactor K1 Delta contactor K2 Individual components for star-delta starters Star contactor K3 Spare auxiliary contacts 660-690 V Timer kw / HP Type Type Type K1 K2 K3 5.5 / 7.5 11 / 15 15 / 20 18.5 / 25 CWM18-10 + BCXMF10 CWM18-11 CWM9-11 RTW-ET... - - - 7.5 / 10 15 / 20 15 / 20 18.5 / 25 CWM18-10 + BCXMF10 CWM18-11 CWM12-11 - - - 7.5 / 10 18.5 / 25 22 / 30 22 / 30 CWM25-00 + 2 x BCXMF10 CWM25-11 CWM18-11 - - - 11 / 15 22 / 30 22 / 30 22 / 30 CWM25-00 + 2 x BCXMF10 CWM25-11 CWM18-11 - - - 15 / 20 30 / 0 37 / 50 37 / 50 CWM0-00 + 2 x BCXMF10 CWM0-11 CWM25-11 - - - 18.5 / 25 37 / 50 37 / 50 5 / 60 CWM50-00 + 2 x BCXMF10 CWM50-11 CWM25-11 - - - 22 / 30 5 / 60 5 / 60 55 / 75 CWM50-00 + 2 x BCXMF10 CWM50-11 CWM32-11 - - - 30 / 0 55 / 75 55 / 75 55 / 75 CWM65-00 + 2 x BCXMF10 CWM65-11 CWM0-11 - - - 37 / 50 75 / 100 75 / 100 90 / 125 CWM95-00 + 2 x BCXMF10 CWM95-11 CWM50-11 - - - 5 / 60 90 / 125 110 / 150 110 / 150 CWM105-00 + 2 x BCXMF10 CWM105-11 CWM65-11 - - - 55 / 75 110 / 150 110 / 150 132 / 175 CWM150-22 CWM150-22 CWM65-11 2NC 1NO/NC - 75 / 100 132 / 175 132 / 175 132 / 175 CWM180-22 CWM180-22 CWM80-11 2NC 1NO/NC - 90 / 125 160 / 220 160 / 220 200 / 300 CWM250-22 CWM250-22 CWM105-11 2NC 1NO/NC - 110 / 150 200 / 270 250 / 330 - CWM300-22 CWM300-22 CWM150-22 2NC 1NO/NC 1NO/NC Wiring kit EC-SD... Star-Delta Starter K1 K1 K3 K2 Star-Delta Starters U1 V1 W1 V2 U2 W2 K3 K2 A: 0.58 x Ir, motor protection at star and delta position B: 1 x Ir, only partial motor protecton at star position C: 0.58 x Ir, motor not protected at star position Contactors - CWM Line 17

CWM Contactors - Spare Parts Individual Spare Coils Illustrative picture Description For use with AC coil DC coil Dual-voltage coils AC/DC (contactors with electronic module) Reference code to complete with voltage code Weight kg CWM9...25 BCA-25 0.065 CWM32...0 BCA-0 0.110 CWM50...105 BCA-105 0.10 CWM112 BCA-112 0.235 CWM180 BCA-180 0.00 CWM250 BCA-250 0.675 CWM0 BECC-0 0.180 CWM50...105 BECC-105 0.220 CWM112...150 BCE-150 0.235 CWM180 BCE-215 0.00 CWM250...300 BCE-300 0.675 CWM00 CWM500...800 BCE00 BCE800 1.0 Electronic Module Illustrative picture Control type For use with Reference code Weight kg AC/DC CWM112 300 ME-300 2) 0.10 Replace with the Appropriate Coil Voltage Code 1) Contactors CWM9...300 Coil voltage codes (CWM9...250) D02 D07 D13 D2 D25 D3 D35 50/60 Hz 2 V 8 V 110 V 230 V 20 V 00 V 15 V Coil voltage codes (CWM0...105) C3 C37 C0 C V dc 2-28 V 2-50 V 110-130 V 208-20 V Coil voltage codes (CWM112...300) E02 E06 E07 E10 E13 E16 E21 50/60 Hz / DC 3) 2-28 V 2-50 V 60-72 V 110-130 V 208-250 V 360-15 V 30-500 V Contactors CWM00...800 Coil voltage codes (CWM00) E36 D80 D81 D82 50/60 Hz / DC 3) 100-20 V ac / 100-220 V dc - - - 50/60 Hz 3) - 265-37 V 380-50 V 0-575 V Coil voltage codes (CWM500...800) E35 E39 D80 D81 D82 50/60 Hz / DC 3) 100-127 V ac / 100-110 V dc 200-20 V ac / 200-220 V dc - - - 50/60 Hz 3) - - 265-37 V 380-50 V 0-575 V Notes: 1) Other voltages on request. 2) The coil voltage code must be the same of BCE coil voltage code selected. 3) Surge suppressor is already integrated. 18 Contactors - CWM Line

CWM Contactors - Technical Data General Data Reference code CWM9 CWM12 CWM18 CWM25 CWM32 CWM0 CWM50 CWM65 CWM80 CWM95 CWM105 CWM112 CWM150 CWM180 CWM250 CWM300 Standards IEC 6097 / UL 508 Rated insulation voltage U i IEC 6097 UL / CSA Rated impuse withstand voltage U imp 6 kv 8 kv Rated operational frequency 25-00 Hz Degree of protection Protection against direct contact from the front when operated by a perpendicular test finger (IEC 536) Main circuits IP20 IP10 IP00 Control circuits and auxiliary contacts IP20 Ambient temperature Operating temperature Storage temperature -25 o C to +55 o C -55 o C to +80 o C Altitude Normal values 90% I e / 80% U e 80% I e / 75% U e Up to 3,000 m 3,000 to,000 m,000 to 5,000 m Overvoltage category / Pollution degree III / 3 Climatic proofing Acc. IEC 60680-2 Pole numbers of main circuits 3 Rated operation voltage U e 690 V 1,000 V Mechanical lifespan Ops x 10 6 10 Electrical lifespan (AC - 3) Ops x 10 6 1.5 1.2 1.1 1.0 Mounting Screw or 35 mm DIN Rail Screw 1,000 V 600 V Control Circuit Reference code CWM9 CWM12 CWM18 CWM25 CWM32 CWM0 CWM50 CWM65 CWM80 CWM95 CWM105 CWM112 CWM150 CWM180 CWM250 CWM300 Rated insulation IEC 1,000 V voltage U i UL, CSA 600 V Rated voltages (standard coil) Us 50/60 Hz 12...660 V 12...550 V - 2...690 - Rated voltages (electronic module) Us 50/60 Hz - 2...500 V Rated voltages Us dc - 2...20 V 2...500 V Closing/Opening (AC) ms 8...20 / 6...13 10...19 / 5...25 15...30 / 9...15 60...70 / 13...17 Operation time 1) Closing/Opening (DC) ms - 50...60 / 55...60 60...70 / 13...17 60...70 / 15...25 Power consumption of the AC coil 50/60 Hz 1) Pick-up (VA) 69.5 98 255 213 21 229 cos ϕ 0.85 0.69 0.32 0.71 0.68 0.73 Sealing (VA)...7.2 6.6...12.3 13.1...19.1 1.8 1.1 1.1 cos ϕ 0.28 0.3 0.5 0.26 0.27 0.26 Coil operation limits 50/60 Hz 1) 0.85...1.1 x U s 0.65...1.1 x U s Pick-up 0.5...0.8 0.5...0.8 0.5...0.8 0.7...0.85 0.7...0.85 0.7...0.85 Bifrequency coils 1) Sealing 0.2...0.6 0.2...0.6 0.25...0.6 0...0.6 0...0.6 0...0.6 Power consumption of the coil - DC coils Pick-up (W) - 20 30 166 15 171 Sealing (W) - 6 6.5 2. 2. 2.5 Number of terminals AC coil 3 2 DC coil - 3 2 Note: 1) Values applicable for contactors CWM112...300 with electronic module. For contactors with standard coil only on request. Contactors - CWM Line 19

CWM Contactors - Technical Data Main Contacts Reference code CWM9 CWM12 CWM18 CWM25 CWM32 CWM0 CWM50 CWM65 CWM80 CWM95 CWM105 CWM112 CWM150 CWM180 CWM250 CWM300 Rated AC-3 (U e 0 V) (A) 9 12 18 25 32 0 50 65 80 95 105 112 150 180 250 300 operational AC- (U e 0 V) (A) 5 7 8 12 16 18.5 23 30 37 50 63 69 73 110 15 current I e AC-1 (θ 55 C, U e 690 V) (A) 25 25 32 5 60 60 90 110 110 10 10 180 225 225 350 10 Rated IEC/EN 6097--1, VDE 0660 (V) 690 1,000 operational voltage U e UL, CSA (V) 600 Rated thermal current I th (θ 55 C) (A) 25 25 32 5 60 60 90 110 110 10 10 180 225 225 350 10 Making capacity - IEC/EN 6097 (A) 300 300 300 50 550 550 1,000 1,000 1,000 1,280 1,280 1,30 1,820 2,100 2,600 3,000 Breaking (U e 00 V) (A) 250 250 250 350 50 50 920 920 920 1,050 1,050 1,290 1,350 1,00 2,000 - capacity (U e =500 V) (A) 250 250 250 320 50 50 920 920 920 1,050 1,050 1,290 1,350 1,00 2,000 - IEC/EN 6097 (U e =690 V) (A) 130 130 130 170 205 205 780 780 780 950 950 - - - - - Short-time 1 sec (A) 55 55 570 630 1,010 1,265 1,580 2,530 2,530 3,300 3,300 3,165 3,763,69,27 - current 5 sec (A) 205 205 25 280 50 50 710 1,130 1,130 1,85 1,85 1,820 2,16 2,673 2,56 - No current 10 sec (A) 1 1 180 200 320 00 500 800 800 1,050 1,050 1,30 1,700 2,100 2,000 - flowing during 30 sec (A) 85 85 10 115 185 230 290 60 60 600 600 826 980 1,212 1,155 recovery time 10 min. and 1 min (A) 60 60 7 80 130 165 205 325 325 30 30 58 69 857 816 - θ 0 C) 3 min (A) 35 35 6 50 90 100 120 185 185 250 250 337 01 95 71 - Protection @600 V - UL/CSA (ka) 5 10 18 against shortcircuits with Coordination type 1 (A) 50 50 63 63 100 125 200 200 200 250 250-355 355 500 630 fuses(gl/gg) Coordination type 2 (A) 25 35 35 50 63 80 100 125 125 160 200 22 250 250 00 500 Impedance per pole (mω) 2. 2. 2. 1.7 1.3 1.0 0.9 0.9 0.9 0.8 0.8 0.5 0.5 0.5 0.3 0.3 Power dissipation AC-1 (W) 1.5 1.5 2.5 3.3.6 3. 6.7 10. 10. 1.9 1.9 16 25 21.6 35 5.7 per pole AC-3 (W) 0.2 0.3 0.8 1.0 1.3 1.5 2.1 3.6 5.5 6.9 8. 6.2 11.1 13.8 17.9 25.7 Utilization category AC-3 U Rated e 0 V (A) 9 12 18 25 32 0 50 65 80 95 105 112 150 180 250 300 operational U e 500 V (A) 7.5 10.5 1 19 2 32 38 55 63 79 85 95 130 155 220 265 current I e U e 690 V (A) 7 9 13 15 22 25 3 8 60 67 82 110 135 185 220 (θ 55 C) U e 1,000 V (A) Not available 19 25 30 37 0 2 8 68 103 126 220 / 230 V (kw) 2.2 3.5 5.5 9.2 11 15 18.5 22 22 30 30 5 55 75 90 (HP) 3 6 7.5 12.5 15 20 25 30 30 0 0 60 75 100 125 380 / V (kw) 3.7 5.5 7.5 11 15 18.5 22 30 37 5 55 55 75 90 132 150 (HP) 5 7.5 10 15 20 25 30 0 50 60 75 75 100 125 175 200 (kw) 3.7 5.5 7.5 11 15 18.5 22 30 37 5 55 55 75 110 132 150 00 / 15 V Rated (HP) 5 7.5 10 15 20 25 30 0 50 60 75 75 100 150 175 200 operational (kw).5 5.5 9.2 11 15 22 30 37 5 55 55 55 90 110 150 185 power 0 V (HP) 6 7.5 12.5 15 20 30 0 50 60 75 75 75 125 150 200 250 500 V (kw).5 5.5 9.2 11 15 22 30 37 5 55 55 55 90 110 150 185 (HP) 6 7.5 12.5 15 20 30 0 50 60 75 75 75 125 150 200 250 660 / 690 V (kw) 5.5 7.5 11 11 18.5 22 30 37 5 55 55 75 110 110 150 185 (HP) 7.5 10 15 15 25 30 0 50 60 75 75 100 150 150 200 250 Percentage of 600 ops./h (%) 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 the maximum operational 1,200 ops./h (%) 100 100 100 100 100 100 100 100 100 75 75 75 75 75 75 75 current at 3,000 ops./h (%) 35 35 35 35 35 35 35 35 35 25 25 25 25 25 25 25 Utilization category AC- Rated operational current Ie AC- (U e 690 V) (A) 5 7 8 12 16 18.5 23 30 37 50 50 55 58 88 116 220 / 230 V (kw) 1.1 1.5 1.5 3 3.7.5 55 7.5 9.2 11 11 18.5 18.5 22 37 5 (HP) 1.5 2 2 5 6 7.5 10 12.5 15 15 25 25 30 50 60 380 / 00 V (kw) 2.2 3 3.7 5.5 7.5 9.2 11 15 18.5 22 22 30 30 37 55 75 (HP) 3 5 7.5 10 12.5 15 20 25 30 30 0 0 50 75 100 (kw) 2.2 3.7.5 5.5 9.2 11 11 15 22 22 30 37 37 5 55 75 15 V Rated (HP) 3 5 6 7.5 12.5 15 15 20 30 30 0 50 50 60 75 100 operational (kw) 2.2 3.7.5 5.5 9.2 11 11 15 22 22 30 37 37 5 55 75 power 0 V (HP) 3 5 6 7.5 125 15 15 20 30 30 0 50 50 60 75 100 500 V (kw) 3 3.7 5.5 7.5 9.2 11 15 18.5 22 22 30 37 5 5 75 90 (cv) 5 7.5 10 12.5 15 20 25 30 30 0 50 60 60 100 125 660 / 690 V (kw) 3.5 5.5 7.5 11 11 15 18.5 22 30 30 5 5 55 90 90 (cv) 6 7.5 10 15 15 20 25 30 0 0 60 60 75 125 125 20 Contactors - CWM Line

CWM Contactors - Technical Data Main Contacts Reference code CWM9 CWM12 CWM18 CWM25 CWM32 CWM0 CWM50 CWM65 CWM80 CWM95 CWM105 CWM112 CWM150 CWM180 CWM300 Utilization category AC-1 3P (NO) or P (NO) 3P (NO) 3P (NO) Rated thermal current I th (θ 55 C) (A) 25 25 32 5 60 60 90 110 110 10 10 180 225 225 10 θ 55 C (A) 25 25 32 5 60 60 90 110 110 10 10 160 190 200 350 Max. operational current at ambient temperature of (up to 690 V) θ 70 C (A) 20 20 25 32 8 8 72 88 88 110 110 120 15 15 250 θ 75 C (A) 17 17 22 26 2 2 63 77 77 95 95 101 12 120 206 220 / 230 V (kw) 9.5 9.5 12 17 22.5 22.5 3 2 2 53 53 68 85 85 156 380 / 00 V (kw) 16.5 16.5 21 29.5 39.5 39.5 59 72.5 72.5 92 92 118 15 15 270 Max. operational power 15 / 0 V (kw) 19 19 2 3 5.5 5.5 68.5 8 8 106.5 106.5 130 160 160 295 θ 55 C (Three-phase resistors) 500 V (kw) 21.5 21.5 27.5 39 52 52 77 95 95 121 121 155 190 190 355 575 / 600 V (kw) 2.1 2.1 30.9 3. 57.9 57.9 86.8 106.1 106.1 135.1 135.1 180 225 225 00 660 / 690 V (kw) 28.5 28.5 38 51 68.5 68.5 100 125 125 160 160 205 255 255 70 Cable size (mm²) 6 10 16 16 35 35 35 50 50 120 120 120 2 x 150 2 poles in parallel I e x 1.7 Current values for connection of 3 poles in parallel I e x 2. poles in parallel I e x 3.2 600 ops./h (%) 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 Percentage of the maximum operational current at 1,200 ops./h (%) 100 100 100 100 100 100 100 100 100 80 80 80 80 80 80 3,000 ops./h (%) 50 50 50 50 50 50 50 50 50 0 0 0 0 0 0 2P (NO/NC) P (2NO+2NC) 2P (NO/NC) Max. operational power θ 55 C (Resistive loads) 220 / 230 V (kw) 5.5 5.5 7.0 9.9 13.2 1.9 22.2 27.5 27.5 3.1 3.1 - - - - 380 / 00 V (kw) 9.5 9.5 12.1 17.1 22.8 25.8 38.6 7.5 7.5 58.9 58.9 - - - - 15 / 0 V (kw) 10.3 10.3 13.2 18.6 2.9 28.2 2.3 51.8 51.8 6.3 6.3 - - - - 500 V (kw) 12.5 12.5 16 22.5 30 3 50.6 62.5 62.5 77.5 77.5 - - - - 660 / 690 V (kw) 16.5 16.5 21.1 29.7 39.6.8 66 82.5 82.5 102.3 102.3 - - - - UL Power Reference code CWM9 CWM12 CWM18 CWM25 CWM32 CWM0 CWM50 CWM65 CWM80 CWM95 CWM105 CWM112 CWM150 CWM180 CWM250 CWM300 General purpose current (600 V) (A) 25 25 32 32 60 60 90 110 110 10 10 170 200 200 300 00 110 / 120 V (HP) 0.75 0.75 1 2 3 3 5 5 7.5 7.5 10 - - - - - 1-phase 220 / 20 V (HP) 1.5 2 3 5 5 5 7.5 10 15 15 20 - - - - - 200 V (HP) 3 3 5 7.5 10 10 15 20 20 25 30 0 50 60 75 100 220 / 20 V (HP) 3 3 5 7.5 10 15 15 20 25 30 0 50 60 75 100 125 3-phase 0 / 80 V (HP) 5 7.5 10 15 20 30 0 50 50 60 75 100 125 150 200 250 550 / 600 V (HP) 7.5 10 15 15 25 25 0 50 60 75 75 100 150 200 250 350 Contactors - CWM Line 21

CWM Contactors - Technical Data General Data and Main Contacts Reference code CWM00 CWM500 CWM630 CWM800 Standards IEC 6097 / UL 508 Rated insulation voltage U i IEC 6097 UL Rated impuse withstand voltage U imp Rated operational frequency Degree of protection Main circuits Control circuits and auxiliary contacts Ambient temperature Operating temperature Storage temperature Altitude Normal values 90% I e / 80% U e 80% I e / 75% U e 1,000 V 600 V 6 kv 25-00 Hz IP00 IP20-25 o C to + 55 o C -55 o C to + 80 o C Up to 3,000 m 3,000 to,000 m,000 to 5,000 m Overvoltage category / Pollution degree III / 3 Climatic proofing Acc. to IEC 60680-2 Pole numbers of main circuits 3 Rated operation voltage U e 690 V Conv. thermal current I th at < 55 o C rated operational current Ie/AC-1 (A) 50 580 660 900 Rated operational current I e AC- (U e 0 V) (A) 300 350 00 630 AC-3 utilization category Rated operational power 220-230 V (kw) 00-15 V (kw) 0 V (kw) 500 V (kw) 690 V (kw) 125 220 220 225 250 Short-circuit rating max. fuse gl-gg (A) 630 800 800 1,000 Max. electrical operational per hour AC-1 Ops/h 300 300 300 300 AC-3 Ops/h 1,200 1,200 1,200 1,200 AC- Ops/h 150 150 150 150 No load Ops/h 1,200 1,200 1,200 1,200 Mechanical lifespan Ops x 10 6 5 Electrical lifespan (AC-3) Ops x 10 6 0.5 0.6 UL Power Ratings Reference code CWM00 CWM500 CWM630 CWM800 General purpose current (600 V) (A) 50 580 660 900 3-phase Control Circuit Reference code (3 pole and pole contactors) CWM00 CWM500 CWM630 CWM800 Coil operation limit 0.85...1.1 x U s Pick-up (xus) 0.78 0.75 Drop-out (xus) 0.30...0.60 0.30...0.60 Coil consumption 200 V (HP) 125 150 200 200 220 / 20 V (HP) 150 200 250 300 0 / 80 V (HP) 300 00 500 600 550 / 600 V (HP) 300 00 500 600 Closing (VA) 571 1,000 Closed (VA) 1 29 Dissipation (W) 5 7.8 Number of terminals 2 150 265 265 265 300 190 330 330 330 330 220 0 0 500 500 22 Contactors - CWM Line

CWM Contactors - Technical Data Terminal Capacity and Tightening Torque - Power Terminals Reference code CWM9 / CWM12 / CWM18 CWM25 Screw type Power terminal capacity 1) mm² Finely stranded with end sleeve 1x 0.5... 2x 0.5...2.5 M3.5x 9 Flat / Phillips Stranded and finely stranded without end sleeve 1x 1...6 2x 1...2.5 2x 2.5...6 Solid 1x 0.5...6 2x 0.5...2.5 2x 2.5...6 Finely stranded with end sleeve 1x 1...10 2x 1...2.5 2x 2.5...6 Mx 12 Flat / Phillips Stranded and finely stranded without end sleeve 1x 2.5...10 2x 2.5...10 AWG (UL) 1...10 1...8 Tightening torque (N.m) 1...1.5 1.6...2.5 Tightening torque (lb.in) (UL) 15 16 Solid 1x 1...10 2x 1...2.5 2x 2.5...10 Note: this information is also valid for built-in auxiliary terminals for CWM9 to CWM18. Reference code CWM32 / CWM0 CWM50 / CWM65 / CWM80 CWM95 / CWM105 Screw type Power terminal capacity One conductor on bottom Finely stranded with end sleeve Mx 16.5 Flat / Phillips Stranded and finely stranded without end sleeve Solid Finely stranded with end sleeve M8 Allen mm Stranded and finely stranded without end sleeve Solid Finely stranded with end sleeve M10 Allen mm Stranded and finely stranded without end sleeve Solid mm² 1...16 1.5...16 1...16 2.5...35 6...35 2.5...35...35 6...35...35 AWG (UL) 1...8 1...1/0 10...1/0 One conductor on top mm² 0.75...16 1...16 0.75...16 1...35 1.5...35 1...35 1.5...50 2.5...50 1.5...50 AWG (UL) 1...8 1...1/0 10...1/0 Two conductors at the same time - bottom conductor mm² 1...16 1.5...16 1...16 2.5...25 6...35 2.5...35...35 6...35...35 AWG (UL) 1...8 1...1/0 10...1/0 Two conductors at the same time - top conductor mm² 0.75...16 1...16 0.75...16 1...25 1.5...35 1...35 1.5...50 2.5...50 1.5...50 AWG (UL) 1...8 1...1/0 10...1/0 Tightening torque (N.m) 2...2.5...6 5...6.5 Tightening torque (lb.in) (UL) 22 0 60 Screw type Main terminal capacity mm² AWG (UL) Reference code CWM112 / CWM150 M6 Hexagon head Solid and stranded Busbars with end sleeve 2x 25...70 2x 2...3/0 2 x (15 x 3) - CWM180 M8 Hexagon head Solid and stranded Busbars with end sleeve 2x 50...120 2x 1/0...250 2 x (20 x 3) - CWM250 / CWM300 M10 Hexagon head Solid and stranded Busbars with end sleeve 2x 50...150 2x 1/0...300 2 x (30 x 5) CWM00 M12 Hexagon head Solid and stranded Busbars with end sleeve 2x 120...185 2x 250...00 2x (30x5) CWM500 / CWM630 M16 Hexagon head Solid and stranded Busbars with end sleeve 2x 185...300 2x 00...600 Tightening torque (N.m) 5...6 1...16 23...26 23...26 5...60 - - 2x (50x5) - CWM800 M16 Hexagon head Solid and stranded Busbars with end sleeve 2x 185...300 2x 00...600 2x (60x5) - Contactors - CWM Line 23

CWM Contactors - Technical Data Terminal Capacity and Tightening Torque - Coil Terminals Reference code CWM9...105 CWM112...300 Screw type Coil terminal mm² AWG (UL) Finely stranded with end sleeve 1x 0.5... 2x 0.5...1.5 2x 1...2.5 1x 20...10 2x 20...1 2x 16...12 M3.5x 10 Flat / Phillips Stranded and finely stranded without end sleeve 1x 1... 2x 1...2.5 1x 16...10 2x 16...12 Solid 1x 0.5... 2x 0.5...1.5 2x 1...2.5 1x 20...10 2x 20...1 2x 16...12 Finely stranded with end sleeve 1x 0.5... 2x 0.5...1.5 2x 1...2.5 1x 20...10 2x 20...1 2x 16...12 M3.5x 10 Flat / Phillips Stranded and finely stranded without end sleeve 1x 1... 2x 1...2.5 1x 16...10 2x 16...12 Tightening torque (N.m) 0.8...1.1 0.8...1.1 Tightening torque (lb.in) (UL) 10 10 Solid 1x 0.5... 2x 0.5...1.5 2x 1...2.5 1x 20...10 2x 20...1 2x 16...12 Reference code CWM00...CWM800 Screw type M Flat / Phillips Coil terminal Finely stranded with end sleeve Stranded and finely stranded without end sleeve Solid mm² 1x 1.25...5.5 or 2x 1.25...5.5 AWG (UL) 16...10 Tightening torque (N.m) 2...2.3 Tightening torque (lb.in) (UL) 17.7...20.3 Terminal Capacity and Tightening Torque - Auxiliary Contact Blocks Reference code BCXMF BCXML Screw type M3.5x9 Fenda / Philips Auxiliary contact block Finely stranded with end sleeve Stranded and finely stranded without end sleeve Solid mm² 1x 0.5... 2x 0.5...2.5 1x 0.75...2.5 2x 0.75...2.5 AWG (UL) 22...12 Tightening torque (N.m) 0.8...1.1 Tightening torque (lb.in) (UL) 10 1x 0.5... 2x 0.5...2.5 2 Contactors - CWM Line

CWM Contactors - Technical Data Auxiliary Contacts Reference code Built-in auxiliary contacts of contactors Auxiliary contact blocks CWM9 CWM12 CWM18 BCXMF... BCXML... BCXMF_AU Rated insulation voltage U i IEC/EN 60 97 UL/CSA (V) (V) Rated operational voltage U e (V) 690 690 Conv. thermal current I th (A) 16 10 1,000 600 1,000 600 Rated operational current I e AC-15 UL/CSA DC-13 UL/CSA 220-20 V 380-00 V 15 V 500 V 2 V 8 V 110 V 220 V (A) (A) (A) (A) (A) (A) (A) (A) 10 6 5 A600 6 2 0.7 P600 10 3.5 2.5 A600 2 0.7 0.3 Q600 3-2 A600 2 0.55 0.3 Q600 Making capacity I m AC-15/AC-11 AC-13/DC-11 U e 00 V 50/60 Hz U e 220 V dc (A) (A) 250 250 90 90 90 - Breaking capacity I c AC-15/AC-11 AC-13/DC-11 U e 00 V 50/60 Hz U e 220 V dc (A) (A) Short-circuit protection max. fuse gl/gg (A) 10 10 Control circuit reliability l e min = 5 ma U e min = 17 V Electrical lifespan Ops 10 6 Mechanical lifespan Ops 10 x 10 6 250 2 60 0.95 60 - l e min = 1 ma U e min = 17 V Reference code BCXML11 CWM800 / BCXMRL11 CWM800 Conv. thermal current I th (A) 16 Rated operational current I e AC category (A600) DC category (P600) 110 V (A) 220 V (A) 0 V (A) 600 V (A) 2 V (A) 8 V (A) 110 V (A) 220 V (A) AC-15 6 5 3 3 DC-13 6 3 1.2 0.2 Mechanical lifespan Ops x 10 6 10 AC-15 0.5 Electrical lifespan Operations x 10 6 AC-12 0.25 DC-13 / DC-12 0.5 Max. electrical operational per hour 1,800 AC-12 10 10 5 5 DC-12 5 3 1.3 0.25 Contactors - CWM Line 25

CWM Contactors - Technical Data Contactors for Lighting Circuits Maximum number of lamps per phase at 220 V Lamp type W A µf CWM9 CWM12 CWM18 CWM25 CWM32 CWM0 CWM50 CWM65 CWM80 CWM95 CWM105 Incandescent Fluorescent Single arrangement Without compensation Fluorescent Single arrangement With compensation High pressure Mercury vapour Without compensation High pressure Mercury vapour With compensation High pressure Sodium vapour Without compensation High pressure Sodium vapour With compensation Metal iodide Without compensation Metal iodide With compensation 60 0.27-62 62 70 77 85 122 156 191 222 26 28 100 0.5-0 0 50 60 66 73 95 116 133 160 170 200 0.91-20 20 25 30 33 36 7 58 66 79 8 300 1.36-13 13 17 20 22 2 31 38 53 56 500 2.27-8 8 10 12 12 1 19 23 26 31 33 1,000.50-5 6 6 7 9 11 13 16 16 2,000 9.1-1 1 2 3 3 3 5 6 8 8 AC-5b¹ ) (A) 18 18 23 27 30 33 3 52 60 73 77 15 0.23-88 98 126 155 22 237 355 390 3 96 553 20 0.37-57 61 78 110 139 17 221 23 270 309 3 0 0. - 8 51 66 93 118 12 186 20 227 260 289 65 0.7-30 32 1 58 7 78 116 127 12 163 181 100 1.5-1 16 19 27 3 36 5 59 66 76 85 15 0.23 3.5 61 77 9 111 13 19 191 232 273 312 37 20 0.25.5 8 61 7 87 103 115 18 180 212 23 270 0 0.3.5 8 61 7 87 103 115 18 180 212 23 270 65 0.5 7 31 39 7 56 66 7 95 115 136 155 173 100 0.7 18 11 1 17 21 23 29 37 5 53 60 67 250 2.13-6 8 10 12 15 18 27 30 33 36 2 00 3.25-5 6 8 10 12 18 20 22 2 28 700 5. - 2 3 5 6 7 11 12 13 1 17 1,000 7.5-2 2 3 3 5 8 9 9 10 12 250 1.3 20 11 1 18 22 27 33 9 55 60 66 77 00 2.1 25 7 9 11 1 17 20 31 3 37 1 8 700 3.6 0 5 6 8 10 12 18 20 22 2 28 1,000 5.3 60 3 3 5 7 8 12 13 15 16 19 250 3-5 7 9 11 13 19 21 2 26 30 00. - 3 5 6 7 9 13 15 16 18 20 1,000 10.3-1 2 2 2 3 6 6 7 7 9 250 1.5 0 10 12 16 20 25 30 9 5 59 69 00 2.5 5 6 7 9 11 1 17 26 29 31 3 0 1,000 5.5 100 3 3 5 6 8 12 13 1 16 18 250 2.17-5 7 9 12 12 19 21 23 25 29 00 3.8-3 3 6 8 8 12 13 1 16 18 700 6.09-1 2 2 3 7 7 8 9 10 1,000 8.7-1 1 2 2 3 3 5 5 6 6 7 2,000 17.39-1 1 1 1 2 2 2 3 3 3 250 1. 32 7 9 11 16 21 21 32 36 39 3 50 00 2 5 5 6 8 11 15 15 23 25 28 30 35 700 3.6 65 3 3 6 8 8 13 1 15 17 19 1,000 5.3 85 2 2 3 6 6 8 9 10 11 13 2,000 10.6 100 1 1 2 2 3 3 5 5 6 7 Note: indicative values - It s highly recommended to take into consideration the values of making capacity and rated AC-1 current when dimensioning the contactor for AC-5b utilization category (AC-5b - Switching of incandescent lamps). 26 Contactors - CWM Line

CWM Contactors - Technical Data Contactors for Lighting Circuits Maximum number of lamps per phase at 220 V Lamp type W A µf CWM112 CWM150 CWM180 CWM250 CWM300 Incandescent Fluorescent Single arrangement Without compensation Fluorescent Single arrangement With compensation High pressure Mercury vapour Without compensation High pressure Mercury vapour With compensation High pressure Sodium vapour Without compensation High pressure Sodium vapour With compensation Metal iodide Without compensation Metal iodide With compensation 60 0.27-318 0 67 578 667 100 0.5-193 25 283 350 0 200 0.91-95 121 10 173 200 300 1.36-6 81 93 116 133 500 2.27-38 9 56 69 80 1,000.50-19 2 28 35 0 2,000 9.1-10 12 1 17 20 AC-5b¹ ) (A) 87 110 127 158 182 15 0.23-652 815 978 1,522 1,783 20 0.37-05 507 608 96 1,108 0 0. - 31 26 511 795 932 65 0.7-21 268 321 500 586 100 1.5-100 125 150 233 273 15 0.23 3.5 09 520 600 73 857 20 0.25.5 318 0 67 578 667 0 0.3.5 318 0 67 578 667 65 0.5 7 20 260 300 371 29 100 0.7 18 79 101 117 1 167 250 2.13-5 62 68 106 12 00 3.25-36 0 5 69 81 700 5. - 21 2 27 2 9 1,000 7.5-15 18 19 30 35 250 1.3 20 79 100 116 13 165 00 2.1 25 63 80 92 11 132 700 3.6 0 39 50 58 72 83 1,000 5.30 60 26 33 39 8 55 250 3.0-39 8 75 88 00. - 26 30 33 51 60 1,000 10.3-11 13 1 22 26 250 1.5 0 5 57 66 81 9 00 2.5 5 0 51 58 72 83 1,000 5.5 100 18 23 26 33 38 250 2.17-37 2 7 73 85 00 3.8-23 26 29 5 53 700 6.09-13 15 17 26 30 1,000 8.7-9 11 12 18 21 2,000 17.39-5 5 6 9 11 250 1. 32 56 71 82 102 117 00 2 5 0 51 58 72 83 700 3.6 65 28 35 0 50 58 1,000 5.3 85 21 27 31 38 2,000 10.6 100 18 23 26 33 38 Note: indicative values - It s highly recommended to take into consideration the values of making capacity and rated AC-1 current when dimensioning the contactor for AC-5b utilization category (AC-5b - Switching of incandescent lamps). Contactors - CWM Line 27

CWM Contactors - Technical Data DC - Utilization Category Utilization Category DC-1 (L/R 1ms) Reference code CWM9 CWM12 CWM18 CWM25 CWM32 CWM0 CWM50 CWM65 CWM80 CWM95 CWM105 U e Poles in series Maximum operational current I e (A) 1 18 18 18 25 32 0 50 65 65 80 80 2 25 25 32 5 60 60 90 110 110 10 10 2 V 3 25 25 32 5 60 60 90 110 110 10 10 25 25 32-1 15 15 15 20 25 35 5 55 55 70 70 2 25 25 32 5 60 60 90 110 110 10 10 8 V 3 25 25 32 5 60 60 90 110 110 10 10 25 25 32-1 12 12 12 18 18 32 0 50 50 65 65 2 25 25 32 5 60 60 90 110 110 10 10 60 V 3 25 25 32 5 60 60 90 110 110 10 10 25 25 32-1 6 6 6 8 8 8 16 16 16 16 16 2 18 18 18 25 5 5 80 90 90 110 110 125 V 3 25 25 25 32 60 60 90 110 110 10 10 25 25 32-1 0.8 0.8 0.8 0.8 1 1 2 2 2 2 2 2 7.5 7.5 7.5 8 8 8 20 20 20 20 20 220 V 3 25 25 25 32 50 50 90 110 110 10 10 25 25 32-1 0. 0. 0. 0. 0.5 0.5 0.8 0.8 0.8 0.8 0.8 2 0.8 0.8 0.8 0.8 1 1 2 2 2 2 2 0 V 3 8 8 8 10 10 10 15 15 15 15 15 15 15 15-1 - - - - - - - - - - - 2 0. 0. 0. 0. 0.5 0.5 1 1 1 1 1 600 V 3 5 5 5 7.5 7.5 7.5 7.5 7.5 8 8 10 - Utilization Category DC-3 (L/R 2.5ms) Reference code CWM9 CWM12 CWM18 CWM25 CWM32 CWM0 CWM50 CWM65 CWM80 CWM95 CWM105 U e Poles in series Maximum operational current Ie (A) 1 12 12 12 18 25 32 0 50 50 65 65 2 18 18 18 25 0 0 65 80 80 105 105 2 V 3 18 18 18 25 0 0 65 80 80 105 105 18 18 18-1 9 9 9 12 18 20 30 35 35 5 5 2 18 18 18 25 0 0 65 80 80 105 105 8 V 3 18 18 18 25 0 0 65 80 80 105 105 18 18 18-1 7.5 7.5 7.5 10 15 15 25 30 30 35 35 2 18 18 18 25 0 0 65 80 80 105 105 60 V 3 18 18 18 25 0 0 65 80 80 105 105 18 18 18-1 2 2 2 2 3 3 3 3 3 3 3 2 10 10 12 18 25 32 50 60 60 85 85 125 V 3 15 15 18 25 32 0 65 80 80 105 105 15 15 18-1 0.6 0.6 0.6 0.6 0.6 0.6 0.8 0.8 0.8 0.8 0.8 2 2 2 2 2 2 2 7 7 7 7 7 220 V 3 12 12 12 18 25 32 50 65 65 95 95 12 15 18-1 - - - - - - - - - - - 2 0.3 0.3 0.3 0.3 0.5 0.5 1 1 1 1 1 0 V 3 1.5 1.5 1.5 1.5 3 3 3 3 3 3 3 1.5 6 6-1 - - - - - - - - - - - 2 - - - - - - - - - - - 600 V 3 0.8 0.8 0.8 0.8 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1 2.5 2.5-28 Contactors - CWM Line

CWM Contactors - Technical Data DC - Utilization Category Utilization Category DC-5 (L/R 15ms) Reference code CWM9 CWM12 CWM18 CWM25 CWM32 CWM0 CWM50 CWM65 CWM80 CWM95 CWM105 U e Poles in series Maximum operational current Ie (A) 1 12 12 12 18 25 32 0 50 50 65 65 2 18 18 18 25 0 0 65 80 80 105 105 2 V 3 18 18 18 25 0 0 65 80 80 105 105 18 18 18-1 9 9 9 12 18 20 30 35 35 5 5 2 18 18 18 25 0 0 65 80 80 105 105 8 V 3 18 18 18 25 0 0 65 80 80 105 105 18 18 18-1 7.5 7.5 7.5 10 15 15 25 30 30 35 35 2 18 18 18 25 0 0 65 80 80 105 105 60 V 3 18 18 18 25 0 0 65 80 80 105 105 18 18 18-1 0.8 0.8 0.8 0.8 1.2 1.2 1.2 1.2 1.2 1.2 1.2 2 5 5 5 5 5 5 50 60 60 80 80 125 V 3 15 15 15 20 25 32 60 70 70 95 95 15 15 18-1 - - - - - - 0.5 0.5 0.5 0.5 0.5 2 0.8 0.8 0.8 0.8 0.8 0.8 3 3 3 220 V 3 3 3 3 3 3 3 7 7 7 7 7 10 10 10-1 - - - - - - - - - - - 2 - - - - - - - - - - - 0 V 3 0. 0.5 0.5 0.5 0.7 0.7 1 1 1 1 1 1.5 2 2-1 - - - - - - - - - - - 2 - - - - - - - - - - - 600 V 3 - - - - - - - - - - - 0.5 0.75 0.75 - Utilization Category DC-1 (L/R 1ms) Reference code CWM112 CWM150 CWM180 CWM250 CWM300 U e Poles in series Maximum operational current I e (A) 1 160 160 200 300 300 2 V 2 180 225 225 350 10 3 180 225 225 350 10 1 18 18 18 33 33 110 V 2 112 150 170 250 280 3 180 225 225 350 10 1 - - - - - 220 V 2 90 120 10 200 220 3 180 225 225 350 10 1 - - - - - 0 V 2 - - - - - 3 85 105 105 165 195 Contactors - CWM Line 29

CWM Contactors - Technical Data DC - Utilization Category Utilization Category DC-3 / DC-5 (L/R 15ms) Reference code CWM112 CWM150 CWM180 CWM250 CWM300 U e Poles in series Maximum operational current I e (A) 1 112 112 180 250 250 2 V 2 112 150 180 250 300 3 112 150 180 250 300 1 18 18 18 33 33 110 V 2 80 95 105 185 205 3 112 150 180 250 300 1 - - - - - 220 V 2 55 55 65 70 80 3 80 120 150 200 200 1 - - - - - 0 V 2 - - - - - 3 27 0 50 67 67 Utilization Category DC-1 (L/R 1ms) Reference code CWM00 CWM500 CWM630 CWM800 U e Poles in series Maximum operational current I e (A) 2 V 2 00 580 630 800 3 00 580 630 800 8 V 2 20 580 630 800 3 00 580 630 800 110 V 2 200 520 630 630 3 00 580 630 800 220 V 2 200 50 630 630 3 300 580 630 800 Utilization Category DC-2 / DC- (L/R 15ms) Utilisation category CWM00 CWM500 CWM630 CWM800 U e Poles in series Maximum operational current I e (A) 2 V 2 00 580 630 800 3 00 580 630 800 8 V 2 200 580 630 630 3 280 580 630 630 110 V 2 150 500 630 630 3 200 550 630 630 220 V 2 90 80 630 630 3 150 500 630 630 1 Poles in Series 3 Poles in Series Load Load Load 2 Poles in Series Poles in Series Load Load Load Load 30 Contactors - CWM Line

CWM Contactors - Technical Data Terminal Markings to EN 50012 Diagram Without auxiliary contact blocks Distinctive number and version of combination NO NC Reference code Additional auxiliary contact blocks 10E 1 0 CWM9-10 CWM12-10 CWM18-10 - 01E 0 1 CWM9-01 CWM12-01 CWM18-01 - Front mounting auxiliary contact blocks BCXMF10 or BCXMF01 11E 1 1 CWM9-10 CWM12-10 CWM18-10 + BCXMF01 21E 2 1 CWM9-10 CWM12-10 CWM18-10 + BXCMF10 + BCXMF01 12E 1 2 CWM9-10 CWM12-10 CWM18-10 + 2 BXCMF01 31E 3 1 CWM9-10 CWM12-10 CWM18-10 + 2 BXCMF10 + BCXMF01 1E 1 CWM9-10 CWM12-10 CWM18-10 + 3 BXCMF10 + BCXMF01 Contactors - CWM Line 31

CWM Contactors - Technical Data Terminal Markings to EN 50012 Diagram Front mounting auxiliary contact blocks BCXMF10 or BCXMF01 Distinctive number and version of combination NO NC Reference code Additional auxiliary contact blocks 22E 2 2 CWM9-10 CWM12-10 CWM18-10 + 2 BXCMF01 + BCXMF10 32E 3 2 CWM9-10 CWM12-10 CWM18-10 + 2 BXCMF01 + 2 BCXMF10 13E 1 3 CWM9-10 CWM12-10 CWM18-10 + 3 BXCMF01 23E 2 3 CWM9-10 CWM12-10 CWM18-10 + 3 BXCMF01 + BCXMF10 Side mounting auxiliary contact blocks each with two contacts 11E 1 1 CWM25-00 to CWM105-00 + BCXML11 31E 3 1 CWM25-00 to CWM105-00 + BCXML11 + BCXML20 22E 2 2 CWM25-00 to CWM105-00 + 1 BCXML11 + 1 BCXMRL11 Without auxiliary contact blocks - 0 0 CWM25-00 to CWM105-00 - Front mounting auxiliary contact blocks BCXMF10 or BCXMF01 10E 1 0 CWM25-00 to CWM105-00 + BCXMF10 01E 0 1 CWM25-00 to CWM105-00 + BCXMF01 32 Contactors - CWM Line

CWM Contactors - Technical Data Terminal Markings to EN 50012 Diagram Front mounting auxiliary contact blocks BCXMF10 or BCXMF01 Distinctive number and version of combination NO NC Reference code Additional auxiliary contact blocks 11E 1 1 CWM25-00 to CWM105-00 + BCXMF10 + BCXMF01 21E 2 1 CWM25-00 to CWM105-00 + 2 BCXMF10 + BCXMF01 12E 1 2 CWM25-00 to CWM105-00 + BCXMF10 + 2 BXCMF01 31E 3 1 CWM25-00 to CWM105-00 + 3 BXCMF10 + BCXMF01 1E 1 CWM50-00 to CWM105-00 + BXCMF10 + BCXMF01 22E 2 2 CWM25-00 to CWM105-00 + 2 BXCMF01 + 2 BCXMF10 32E 3 2 CWM50-00 to CWM105-00 + 2 BXCMF01 + 3 BCXMF10 13E 1 3 CWM25-00 to CWM105-00 + BCXMF10 + 3 BXCMF01 23E 2 3 CWM50-00 to CWM105-00 + 3 BXCMF01 + 2 BCXMF10 Contactors without auxiliary contact blocks + Side mounting auxiliary contact blocks each with two contacts 22 2 2 CWM112 to CWM800 + 2 BCXML11 A1 1 3 5 13 21 31 3 53 A2 2 6 1 22 32 5 61 62 71 72 83 8 CWM112 to CWM800 + 2 BCXML11 + 2 BCXMRL11 Contactors - CWM Line 33

CWM Contactors - Technical Data Terminal Markings to EN 50012 Diagram pole contactors A1 A2 1 2 3 5 6 7 8 A1 A2 1 2 R1 R2 R3 R 3 Configuration Power contacts NO NC - 0-2 2 Reference code CWM9-00-0 CWM12-00-0 CWM18-00-0 CWM9-00-22 CWM12-00-22 CWM18-00-22 Diagram Front mounting auxiliary contact blocks BCXMF10 or BCXMF01 Configuration NO Auxiliary contacts NC Reference code 10 1 0 BCXMF10 01 0 1 BCXMF01 10 1 0 BCXMFA10 01 0 1 BCXMFR01 Diagram Side mounting auxiliary contact blocks each with two contacts Configuration NO Auxiliary contacts NC Reference code 20 2 0 BCXML20 11 1 1 BCXML11 20 2 0 BCXMRL20 11 1 1 BCXMRL11 11 BCXML11 CWM800 1 1 11 BCXMRL11 CWM800 Electrical and mechanical interlock for contactors 02 0 2 BLIM.02 3 Contactors - CWM Line

CWM Contactors - Technical Data Electrical Lifespan AC-3 (U e 0 V ac) CWM9 CWM12 CWM18 CWM25 CWM32 CWM0 CWM50 CWM65 CWM80 CWM95 CWM105 CWM112 CWM150 CWM180 CWM250 CWM300 10 Number of operations (10 6 ) 1 0.1 1 10 18 32 65 100 150 300 1,000 Rated operational current I e (A) Number of operations (10 6 ) 0.1 CWM00 CWM500 CWM630 CWM800 Rated operational current I e (A) 1,000 Contactors - CWM Line 35

CWM Contactors - Technical Data Electrical Lifespan AC- (U e 0 V ac) CWM9 CWM12 CWM18 CWM25 Number of operations (10 6 ) CWM32 CWM0 CWM50 CWM65 CWM80 CWM95 CWM105 0.1 0.01 Breaking current I c (A) 1,000 CWM112 CWM150 CWM180 Number of operations (10 6 ) CWM250 CWM300 0.1 0.01 10,000 Breaking current I c (A) 36 Contactors - CWM Line

CWM Contactors - Technical Data Electrical Lifespan AC- (U e 0 V ac) 1.0, Number of operations (10 5 ) 0.1, CWM00 CWM500 CWM630 0.01, CWM800 1,000 Breaking current I c (A) - AC- AC-1 (U e 690 V ac) 10 CWM9 CWM12 CWM18 CWM25 CWM32 CWM0 CWM50 CWM65 CWM80 CWM95 CWM105 Number of operations (10 5 ) 1 0.1 0,1 1 10 25 32 5 60 90 110 10 1.000 1,000 Breaking current I c (A) - AC- Contactors - CWM Line 37

CWM Contactors - Technical Data Electrical Lifespan AC-1 (U e 690 V ac) Number of operations (x10 6 ) CWM112 CWM150 CWM180 CWM250 CWM300 0.1 1,000 Breaking current I c (A) CWM00 Number of operations (x10 6 ) 0.1 CWM500 CWM630 CWM800 1,000 Breaking current I c (A) 38 Contactors - CWM Line

CWM Contactors - Dimensions (mm) CWM9, CWM12 and CWM18 68 35 11.5 5 11.5 87.8.5 72.5 77.5 81 DIN RAIL 35 mm BCXMF BCXML BCXML CWM25 35 68 11.5 5 11.5 87 A 29.8.5 72,5 77.7 81 DIN RAIL 35 mm BCXMF CWM32 and CWM0 BCXML BCXML Coil AC DC A = 98 A = 118 78.98 11.5 55 11.5 A 29 79 77.7 16.5 16.5 DIN RAIL 35 mm BCXMF 12.5.5 BCXML CWM50, CWM65 and CWM80 70 89 11.5 66 11.5 A 29 Coil AC DC A = 116 A = 116 90 60 DIN RAIL 35 mm 56 7.5 5.5.5 6 10 10 89 87 BCXML 112 77.7 116.5 100 BCXMF BCXML BCXML Contactors - CWM Line 39

CWM Contactors - Dimensions (mm) CWM95 and CWM105 70 98 11.5 75 11.5 Coil AC DC A = 126 A = 126 A 29 60 90 56 11.5 77.7 117 100 DIN RAIL 35 mm BCXMF CWM112 and CWM150 100 1.5 121.5 118 17 15 ME-300 (eletronic module) 7 BCXMRL CWM150 BCXML CWM180 110 162 139 135 172 170 ME-300 (eletronic module) BCXMRL 160 150 183 180 9.5 5.5 6 7.5.5 BCXML 162,5 130 125 150 155 5.90 CWM180 7 12 Ø9 BCXML 0 Contactors - CWM Line

CWM Contactors - Dimensions (mm) CWM250 and CWM300 120 13 171. 18. 1 181 ME-300 (electronic module) 10.5 180 175 A C A B Models A B C D CWM9...25 35 72.5 22 102 CWM32...0 5 79 22 122 CWM50...80 57 90 21 1 CWM95...105 57 90 29.8 153 11.5 8.5 BLIM112-300 A C A Models A B C D CWM112...150 100 130 51 272.5 CWM180 110 160 58.5 303.5 CWM250...300 120 180 57 325. B 51 205 BCXMRL 200 BCXML Ø11 BLIM9-105 and BLIM.02 6.5 D Contactors - CWM Line 1

CWM Contactors - Dimensions (mm) BMP CWM112...300 BMP CWM150 + CWM112/150 BMP CWM180 + CWM180 BMP CWM300 + CWM250/300 A 112.5 127.5 18.5 B 256 290. 320.8 C 128 137.7 16 D 86 90.7 8 E 53 55.2 60.5 F 2 7 62 TB... + CWM112...300 A TB150 + CWM112/150 TB180 + CWM180 TB300 + CWM250/300 A 167.6 190.3 218.6 B 151.1 176 193.8 B Mounting Position CWM9...105 CWM112...300 30 30 30 30 2 Contactors - CWM Line

225 www.weg.net CWM Contactors - Dimensions (mm) CWM00-3-Pole 12 163 12 110 55 133, 133. 200.7 200,7 15 60 Ø 9 Ø9 50 236,3 207,3 23 236,6 225 210 220 R,5 50 1,5 Ø 1 Ø1 30 60 163 CWM00 - -Pole 198.1 198,1 12 209 30 111 55 133. 133, 8xØ9 8xØ9 15 105 201 23 230 225 1.5 236.3 207.3 23 236.6 225 210 220 R.5 12 55 56 55 Ø1 Ø1 105 15 Contactors - CWM Line 3

Ø17 17 www.weg.net CWM Contactors - Dimensions (mm) CWM500, CWM630 and CWM800-3-Pole 160 26.5 26,5 80 19,3 19.3 250 Ø 15,9 Ø15.9 Ø 17 0 CWM500, CWM630 and CWM800 - -Pole 35 0,5 0.5 12 Ø12 308 271 310 270 310 310 271 271 290 290 331 331 250 R7.9 R7,9 Ø17 19, 5 19.5 285 285 17,3 17.3 80 80 80 21,3 21.3 379,8 379.8 Contactors - CWM Line

CWM Contactors - Dimensions (mm) BLIM CWM00 B C E D BLIM BLIN CWM00 E A G BLIM CWM800 Ø23.5 23.5 75 75 C C B B D F A E BLIM CWM00 + CWM00 BLIM CWM800 + CWM500...800 3-pole -pole 3-pole -pole A 330 375 B 371.2 6 C 330 375 D 225 225 E 0 85 F 0 85 G 203.9 198.2 A 680 70 B 351 370 C 321 30 D 0 0 E 321 316.3 F 86 86 G 75 75 Contactors - CWM Line 5

CWM Contactors - Dimensions (mm) BMP CWM00...800 A C ED BMP CWM00 + CWM00 BMP CWM800 + CWM500...800 3-pole -pole 3-pole -pole A 18.8 21 23 31 B B 28.2 250.8 320.2 350.5 C 200.7 198.2 26.5 21.3 D 2.6 1.76 111.6 20.25 E 2.6 7.76 15.1 20.25 E E BMJ CWM00...800 B A D F BMJ CWM00 + CWM00 BMJ CWM800 + CWM500...800 E E H H A 10.2 202 B 55 80 C 30.2 2 D 187. 199.15 E 53.6 7.65 F 59.5 65.7 G 350.2 39.3 G C Mounting Position CWM00...800 30 30 30 30 6 Contactors - CWM Line 50

Global presence is essential, as much as understanding your needs. Global Presence With more than 30.000 employees worldwide, WEG is one of the largest electric motors, electronic equipments and systems manufacturers. We are constantly expanding our portfolio of products and services with expertise and market knowledge. We create integrated and customized solutions ranging from innovative products to complete after-sales service. WEG s know-how guarantees our Contactors - CWM Line is the right choice for your application and business, assuring safety, efficiency and reliability. Availability is to have a global support network Partnership is to create solutions that suits your needs Competitive edge is to unite technology and inovation Know More High performance and reliable products to improve your production process. Excelence is to provide a whole solution in industrial automation that improves our customers productivity. Visit: www.weg.net youtube.com/wegvideos Contactors - CWM Line 7