RDLO / RDLO V. Axially Split Volute Casing Pumps. Fields of Application. Bearings. Operating Data. Materials. Design. Shaft Seal. Designation 01 P F

Similar documents
Axially split volute casing pumps. Applications. Bearings. Shaft seal. Operating data

RDLO / RDLO V Type Series Booklet

RDLO / RDLO V Type Series Booklet

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

Bearings. Shaft seal. Materials

Data sheet. Customer item no.: Communication dated: Number: ES Doc. no.: Item no.: 100 Quantity: 1 Date: 19/03/2015 Page: 1 / 6

Data sheet. Omega B GB G F Version no.: 1. Operating data. Design. Driver, accessories. Clean water. Actual developed head 57.

KSB RPH-V. Process pumps. 3. Designation. 1. Application. 2. Design. 4. Operating Data. to API 610, 11th edition and ISO 13709

Boiler Feed Booster Pump YNK. Type Series Booklet

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74.

Heat Transfer Fluid / Hot Water Pump HPK-L. Type Series Booklet

SMN Double-Suction Axially Split Pump

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

CPS. Horizontal Split Case Centrifugal Pump

Etanorm SYT Type Series Booklet

PA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD.

Axial geteilte Spiral-gehӓusepumpen Axial split case pumps ASE ( ) PUMPS I MOTORS I SYSTEMS I SERVICES

SMD axially split casing, double suction pump

Elite. KSB Australia Pty Ltd. Centrifugal Pump

Contents. Identification

Omega/Omega V Axially split volute casing pumps Automation products available: Omega Omega V Applications Bearings Omega Omega V Operating data

KIRLOSKAR ROMAK PUMP - RMK ISO 2858 / DIN EN / ISO 5199

Data sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m

PN 16/PN 25 Volute Centrifugal-Pumps for Heat Transfer Media Thermal Oil up to 400 C Hot Water up to 207 C

NB /193 A-F2-A-BAQE

High-pressure pumps Series HP49

BEV. Deep well vertical pumps. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C

KWP non-clogging centrifugal pump. Designation

The e-nsc End Suction Pump Series

RWCP, RWCN. Vertical pumps for tanks for loaded liquids. 1. Fields of Application. 3. Design. 4. Designation. 2. Operating Data

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

Side channel pumps PN 16 SOH - SOHB - SOHM. Self-priming centrifugal pumps. Technical description

Data sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.

SIHI multi Type MSC. Modular multistage pumps. Description. Construction. Applications. Optional special designs. Materials.

Data sheet. Page: 1 / 7. ETL GG AV11D BKSBIE3M Inline pump. Operating data. Design

MZ, MA. Liquid ring pumps. 3 Design. 1 Fields of application. 4 Designation. 5 Materials. 2 Operating Data

Chemical pump with plastic liner in close-coupled design

High-pressure pumps Series HP45

Goulds Small Capacity Double Suction Pump

Etaprime B Type Series Booklet

TKL. Hydro-Titan Heavy Duty Back Pull-out Water & Process Liquid Pump. Experience In Motion

ILN, ILNC. In Line vertical pumps. ILN single suction ILN double suction ILNC. 1. Fields of Application. 3. Design. 4. Designation. 2.

Self-priming Pump. Etaprime B. Type Series Booklet

NB /263 AS-F2-A-BAQE

ZPP and Z22 Double Suction Axially Split Single Stage Centrifugal Pumps

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

Side channel pumps PN 16 SOH - SOHB. Self-priming centrifugal pumps. Technical description

NB80-160/161 A-F2-A-BQQE

Ajax ISO. Centrifugal Pump ISO Application Application. Designation Designation. Operating Data - 50 Hz. Design. Type Series Booklet

Process Pump RPH. Type Series Booklet

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

General Catalog. A New Vision for Quality Pumps. General Catalog

Grey Water and Condensate Pump. Rotex. Type Series Booklet

INVCP, INVCN. Vertical pumps for tanks. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data

Norm-Centrifugal Pumps PN 10

NB /438 A-F1-A-GQQE

Horizontal Double Suction Volute Pump Type CN. Pipe line

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 13/03/2017

Non-clogging Pump DBS TECHNICAL DATA. Output: up to 1200 m 3 /h

Side channel pumps ADH/CDH AEH TECHNICAL DATA. Temperature: max. 120 C. PN 40 for AEH

NK /310A2F1AE-SBAQE

EN. 850 Filtrate Pumps. Technical Specification Pages

IDROCHEMICAL CENTRIFUGAL PUMPS FOR CHEMICAL SERVICE ACCORDING TO ISO 2858 STANDARDS

Mag-drive Pump. Magnochem-Bloc. Type Series Booklet

VERTICAL IN-LINE PUMP

CR3-17 A-FGJ-A-E-HQQE 1x220/240 50HZ

Waste Water, Condensate and Heat Transfer Fluid Pump. Type Series Booklet

CR1-4 A-FGJ-A-E-HQQE 3x230/400 50HZ

End suction back pull-out pumps for general industry, mining, rural and building services

CR A-F-A-V-HBQV 3x400/ HZ

Story of 3 R s. Pum pen Intel 1 ligen z

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

HYDRO-TITAN. Heavy duty back pullout water & process liquid pumps

PN 16 Volute Centrifugal Pumps (depending on materials up to PN 25) according to EN 22858/ISO 2858 and EN ISO 5199

SJP Vertical Propeller Pumps

NBE40-125/139 AS-F2-A-BAQE

Non-clogging Pump DBS TECHNICAL DATA. Output: up to 1200 m 3 /h. depending of the pump size and material execution

CRN3-3 A-FGJ-G-V-HQQV 3x230/400 50HZ

NK40-160/172A1F2AE-SBAQE

CR5-7 A-FGJ-A-E-HQQE 3x230/400 50HZ

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

Normpumpen nach DIN EN 733 einschl Standard horizontal pumps to DIN EN 733 NORMA J ( ) PUMPS I MOTORS I SYSTEMS I SERVICES

Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML

TP /4-A-F-A-BUBE 400Y 50HZ

CR3-7 A-A-A-E-HQQE 1x220/240 50HZ

Dry installed end-suction pumps, LSN-series. according to ISO 2858 / ISO 5199

CRI3-25 A-P-I-E-HQQE 3x400D 50HZ

CRI10-04 A-FGJ-I-E-HQQE 3x230/ HZ

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

NBE50-250/205 A-F2-A-BAQE

CRN10-09 A-FGJ-G-V-HQQV 3x400D 50 HZ

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

CR A-F-A-V-HQQV 3x400/ HZ

Volute Casing Centrifugal Pumps of the Block-Type Construction with Magnetic Coupling

CR15-14 A-F-A-E-HQQE 3x400/ HZ

G&L Series MPVN. High Pressure Multi-Stage Pumps. Goulds Pumps. ITT Industries

Volute Casing Pump additional sizes to those of ISO 2858/EN 22858

Transcription:

Type Series Booklet 1387.5/2--10 RDLO / RDLO V Axially Split Volute Casing Pumps Fields of Application Waterworks, irrigation and drainage pumping stations, power stations, industrial water supply systems, shipbuilding as well as general petrochemical applications. Operating Data DN 350 to 700 Capacities Q to 2800 l/s Heads H to 240 m Operating pressures p to 25 bar Operating temperatures T to +105 _C Design Single--stage, axially split volute casing pump with double--entry radial impeller, for horizontal and vertical installation. Horizontal drive installed either to the left or right of the pump. Connecting flanges drilled on option to ISO, DIN or ASME. Shaft Seal Gland packing or single--acting, hydraulically balanced, reversible mechanical seal. Designation RDLO V Type series Vertical installation Discharge nozzle DN Nominal impeller diameter [mm] Impeller form 500-685 A Bearings RDLO: 01 P F RDLO V: Materials Grease--lubricated rolling element bearings at either end, optional: oil lubrication Grease--lubricated rolling element bearings, bottom bearing on option as product--lubricated plain bearing to either DIN or ASTM standards Volute casing Cast iron Nodular cast iron Ni--Resist Impeller Bronze CrNi cast steel Shaft Min. 13% chrome steel Duplex steel Shaft protecting sleeve Min. 13% chrome steel Duplex steel Casing wear ring Bronze Duplex cast steel Lubrication of bearings (F= grease, O= oil, M = pumped medium) Shaft seal (P= gland packing, G= mechanical seal) Material combination acc. to table

RDLO / RDLO V Your Technical Advantages Your Service Advantages Innovative casing -- In--line design -- Short distance between bearings and correspondingly short shaft -- Leak--free thanks to compact casing split flange with long prestressed bolts -- Change of the direction of rotation possible with identical parts -- All pump sizes with double volute -- Easy mounting of self--aligning upper casing High performance impeller -- Minimum axial thrust due to double--entry impeller -- Optional impeller wear rings -- New vane passage with excel-- lent hydraulic characteristics Easy -to -service shaft -- Completely sealed and dry for zero corrosion -- Short and rigid with negligible vibra-- tions -- Replaceable shaft protecting sleeves -- No threads exposed to pumped medium, i.e. long service life and no corrosion -- Assembly without requiring adjustment -- Fast and easy assembly/distmantling of the rotor components due to elasti-- cally prestressed mountings Long -life bearings -- Grease--lubricated rolling element bearings (allowing relubrification) for alongservicelife>100000hinall operating ranges -- Optional: oil lubrication -- Closed bearing brackets for low--noise and low vibration operation Excellent efficiency Outstanding NPSH values -- Computer--optimised double--entry impellers -- Smooth surfaces inside the casing and on the impeller -- Large inlet cross--sectional areas for optimum suction behaviour -- Consistently high efficiency due to replaceable profiled casing wear rings and impeller wear rings -- Quiet, low--wear running thanks to swirl--free intake elbow with low energy loss Seals tailored to the application -- Asbestos--free gland packings meeting drinking water quality standards -- Split glands, i.e ample space for servicing -- Optional: balanced mechanical seal 2 Subject to technical modifications 1387.5/2--10

RDLO / RDLO V Contents Selection Charts 50 Hz / 60 Hz Page 4 General Information: -- Scope of Supply Page 5 -- Packaging and Dispatch / Transport -- Guarantee, Inspections/Testing and Quality Assurance -- Order Data Types of Installation Page 6 Directions of Rotation / Flow Page 7 Materials / Application Limits Page 7 Pressure Limits Page 8 Technical Data Page 9 Speed Control; Vibration Behaviour Page 10 Surface Coating Page 10 Arrangement of Sealing and Flushing Pipe Page 11 Sectional Drawing RDLO Page 12 Options: oil lubrication, resistance thermometer PT 100 Page 13 Sectional Drawing RDLO V Page 14 Detail of bottom bearing Page 15 Option: Product--lubricated Plain Bearing Page 15 Option: Gland Packing Page 16 Option: Mechanical seal (balanced) Page 16 Option: Impeller with impeller wear ring Page 16 Noise Characteristics for Pumps without Motor Page 17 Dimension Tables RDLO Page 18 -- 23 Dimension Tables RDLO V Page 24 -- 29 General Arrangement Drawing 2E Page 30 -- 35 General Arrangement Drawing 3E Page 36 -- 41 General Arrangement Drawing 4E Page 42 -- 47 General Arrangement Drawing DK Page 48 -- 53 Recommended Spare Parts for Commissioning Page 54 Recommended Spare Parts for 2 Years Operation Page 55 Recommended Spare Parts for 5 Years Operation Page 56 Interchangeability of Pump Components, Horizontal Pump Page 57 Interchangeability of Pump Components, Vertical Pump with Rolling Element Bearing Page 58 at Bottom Interchangeability of Pump Components, Vertical Pump with Plain Bearing at Bottom Page 59 1387.5/2--10 Subject to technical modifications 3

RDLO / RDLO V Selection Chart 50 Hz 200 5000 6000 7000 8000 10000 12000 14000 16000 20000 25000 30000 Q [U.S. gpm] 45000 150 100 80 350-690 1480 1/min 400-935 985 1/min 350-575 1480 1/min 500-1015 985 1/min 500-835 985 1/min 500-1035 985 1/min 500-860 985 1/min 600-1075 985 1/min 600-885 985 1/min 700-980 985 1/min 500 300 60 H [m] 40 400-705 985 1/min 400-665 985 1/min 500-685 985 1/min 600-705 985 1/min 700-980 740 1/min 200 H [ft] 30 20 400-525 985 1/min 500-585 985 1/min 600-600 985 1/min 100 300 400 500 600 700 800 1000 2000 Q [l/s] 3000 50 1200 1500 2000 3000 5000 7500 Q[m 3 /h] 10000 Selection Chart 60 Hz 250 5000 6000 7000 8000 10000 12000 14000 16000 20000 25000 30000 Q [U.S. gpm] 45000 200 150 350-690 1780 1/min 400-935 1180 1/min 350-575 500-860 1180 1/min 600-1075 895 1/min 500 100 80 1780 1/min 350-690 400-705 1180 1/min 1180 1/min 500-835 1180 1/min 600-885 895 1/min 500-685 700-980 895 1/min 600-705 1180 1/min 300 60 H [m] 40 350-575 1180 1/min 400-665 1180 1/min 1180 1/min 500-585 1180 1/min 700-980 715 1/min 200 H [ft] 400-525 30 1180 1/min 100 20 600-600 1180 1/min 300 400 500 600 700 800 1000 2000 3000 Q [l/s] 50 opt A -type impeller opt B -type impeller 1200 1500 2000 3000 5000 7500 Q[m 3 /h] 10000 4 Subject to technical modifications 1387.5/2--10

RDLO / RDLO V Scope of Supply RDLO: Pump with bare shaft end, priming coat, gland packing, 4 instruction manuals RDLO V: Pump with bare shaft end, baseplate, priming coat, gland packing, 4 instruction manuals Available against extra charge: -- oil--lubricated rolling element bearings, mechanical seal, interior coating meeting drinking water quality standards, finish coat, baseplate for pump or pump/motor, motor stools for vertical installation, materials testing, additional instruction manuals Available accessories: -- coupling and coupling guard, vibration sensor SPM nipple -- set of pressure gauges, cyclone separator with piping -- vent valve, drain valve -- temperature sensor for rolling element bearing (PT 100), limit--value alarm for PT 100 -- universal--joint shaft for two--floor installation Packaging and Dispatch / Transport RDLO: Where appropriate, the pump sets are assembled completely at the factory in order to check them for proper adjustment. Afterwards they are disassembled for shipping, and the components are dispatched separately. RDLO V: The vertical pump, the motor stool, and the associated motor are dispatched separately. Guarantee, Inspections/Testing, Quality Assurance Each pump is subjected to a functional test. The operating data are guaranteed by way of a performance test in accordance with ISO 2548 C, DIN 1944/III or comparable international codes/standards. A performance test witnessed by the customer in accordance with ISO / DIN or comparable codes/standards can be performed against extra charge. The quality of our RDLO products is ensured by a quality assurance system audited and certified to DIN ISO 9001 / EN 29001. Order Data Pump: -- Designation of the pump according to Designation -- Capacity Q -- Discharge head H (H geo and system losses) -- Material combinations -- lange design (bolt hole pattern) -- Shaft seal: gland packing or mechanical seal -- Grease or oil lubrication of bearings -- Medium pumped and temperature of medium pumped -- Solids content -- Direction of rotation / motor position -- Accessories required -- Quantity and language of instruction manuals Motor: (selected by KSB) -- Type of construction -- Type of enclosure -- Voltage, frequency, starting method -- Ambient temperature -- Thermal class -- Accessories required (provided by customer) Binding dimensional drawing and data sheets of motor incl. specification of the effective speed to be submitted with the purchase order. 1387.5/2--10 Subject to technical modifications 5

RDLO / RDLO V Types of installation Horizontal 2E 3E 4E Vertical DK DJ 6 Subject to technical modifications 1387.5/2--10

RDLO / RDLO V Directions of Rotation / Flow Horizontal Vertical Direction of rotation as viewed from the shaft end anticlockwise Direction of rotation as viewed from the shaft end clockwise Direction of rotation as viewed from the shaft end anticlockwise Direction of rotation as viewed from the shaft end clockwise Materials / Application Limits Temperatures Gland packing / mechanical seal: max. 105 C 25 _C Crude water / non--potable water Sea water Media pumped Solids content max. 100 mg/l 1) max. 100 mg/l Material combination Part No. Description 01 011 02 021 03 031 04 041 05 2) 06 2) 102 Volute casing 3) Cast iron Nodular cast iron Cast iron Nodular cast iron Cast iron Nodular cast iron Cast iron Nodular cast iron Ni--Resist 211 Shaft Min. 13 % chrome steel Duplex steel 234 Impeller Bronze Austenitic cast steel 350 Bearing housing Cast iron 360 Bearing cover Steel 441 Shaft seal housing Cast iron Ni--Resist 452 Gland Nodular cast iron 502 Casing wear ring Bronze Duplex cast steel 503 Impeller wear ring -- Bronze -- Duplex cast steel 524 Shaft protecting Gland packing: min. 13 % chrome steel sleeve Mechanical seal: bronze Duplex steel 433 Mechanical seal Carbon / SiC (B Q1EGG to DIN 24960) 901.1 Hexagon head bolt Quenched and tempered steel Duplex steel 1) Other pumped media and solids contents on request 2) On request 3) Select the material for the volute casing based on the operating pressure and test pressure (see page 8) -- Duplex cast steel 1387.5/2--10 Subject to technical modifications 7

RDLO / RDLO V Pressure Limits Operating Pressure and Test Pressure: The standard test pressure is calculated as follows: 1.2x(H Q=0 +H Inlet )or 1.5x(H Q=Qopt +H Inlet ) The higher value is to be used The values for operating pressure and test pressure of the RDLO stated in the table below must not be exceeded. Permissible operating pressures in bar Maximum permissible test pressures in bar Material combinations 01/02 03/04 11/21 31/41 05/06 *) 01/02 03/04 11/21 31/41 05/06 *) 350-575 8.5 8.5 19.4 19.4 *) 10.2 10.2 23.6 23.6 *) 350-690 10.2 10.2 25.0 25.0 *) 12.2 12.2 31.5 31.5 *) 400-705 9.9 9.9 14.4 14.4 *) 11.8 11.8 18.0 18.0 *) 400-935 9.5 9.5 25.0 25.0 *) 11.4 11.4 32.1 32.1 *) 400-525 7.6 7,6 10.9 10.9 *) 9.1 9.1 13.1 13.1 *) 400-665 8.9 8.9 17.9 17.9 *) 10.7 10.7 21.6 21.6 *) 500-585 8.1 8.1 9.7 9.7 *) 9.7 9.7 11.6 11.6 *) 500-685 8.1 8.1 13.0 13.0 *) 9.7 9.7 15.6 15.6 *) 600-600 7.3 7.3 9.3 9.3 *) 8.7 8.7 11.2 11.2 *) 600-705 7.2 7.2 12.7 12.7 *) 8.6 8.6 15.2 15.2 *) 500-835 8.1 8.1 19.6 19.6 *) 9.7 9.7 24.0 24.0 *) 500-1015 8.5 8.5 21.5 21.5 *) 10.2 10.2 27.0 27.0 *) 500-860 7.5 7.5 19.2 19.2 *) 8.9 8.9 23.6 23.6 *) 500-1035 8.5 8.5 21.7 21.7 *) 10.2 10.2 27.0 27.0 *) 600-885 7.6 7.6 14.8 14.8 *) 9.1 9.1 18.0 18.0 *) 600-1075 8.4 8.4 23.0 23.0 *) 10.1 10.1 28.5 28.5 *) 700-980 7.7 7.7 17.2 17.2 *) 9.3 9.3 20.7 20.7 *) *) On request Flanges When specifying the casing flanges, the following must be observed: -- Nominal pressures of flanges operating pressures -- Flanges of suction and discharge nozzles have equal nominal pressures -- The permissible codes/standards for the flanges and the nominal pressures are stated in the dimension tables. 8 Subject to technical modifications 1387.5/2--10

RDLO / RDLO V Technical Data Seal chamber dimensions Shaft diameter Inside diameter d Outside diameter Length L at bearing fit Gland D Mechanical seal packing 350--575 350--690 400--705 100 130 125 170 400--935 400--525 400--665 120 500--585 500--685 110 140 135 180 600--600 600--705 500--835 500--860 500--1015 130 160 155 210 500--1035 140 600--885 600--1075 150 180 175 230 700--980 F z M z F y F x M y M x Permissible forces acting on the nozzles F x,f y, F z 1) 2) Permissible moments acting on the nozzles M x,m y, M z 1) 2) Mass moments of inertia J (without coupling) in kgm 2 N N Nm Nm without water with water 350--575 4.325 6.0 5900 8300 3300 4600 350--690 5.44 6.975 400--525 3.45 4.875 400--665 7.5 10.35 6900 9700 3800 5300 400--705 8.65 11.85 400--935 20.18 27.64 500--585 5.15 7.275 500--685 10.08 13.95 500--835 17.8 25.5 8800 12300 4900 6900 500--860 28.2 36.24 500--1015 32.45 46.5 500--1035 48.3 62.08 600--600 8.5 13.6 600--705 13.7 18.5 10700 15000 6000 8400 600--885 29.23 38.77 600--1075 51.65 68.52 700--980 12600 17600 7100 9900 61.75 66.45 1) Values applicable for casing material cast iron 2) Values applicable for casing material nodular cast iron and Ni--Resist 1387.5/2--10 Subject to technical modifications 9

Speed Control If speed control is provided, we recommend to always select mechanical seals for the shaft! The speeds stated in the selection charts on page 4 must not be exceeded! Vibration Behaviour Vibration values of the pump to ISO 10816--3, machinery class 3, zone B: In the operating range of 0.5 to 1.2 x Q Opt :V eff 4.5 mm/s Surface Coating Application range 60 C > 60 C Casing material Grey cast iron / Nodular cast iron RDLO / RDLO V 4) approved for drinking water applications, maximum permissible temperature 60 C. Coatings at customer s option (interior and/or exterior coatings) may only be offered after consultation and technical clarification 10 Subject to technical modifications 1387.5/2--10 Duplex Grey cast iron / Nodular cast iron Normal Type A No coating No coating No coating Casing, inside With coating approved Drinking water for drinking water No coating -- -- applications Casing, outside Normal Type A Type A Type B Type B Special surface coating for higher temperatures available on request Type A) Standard surface coating Coating Interior 1) Exterior (ZN 35 EN B1--3) 2) Preparatory treatment Grease--free / blasting SA1 Grease--free / blasting SA1 A Primer 1--component anti--rust primer 1--component anti--rust primer Without extra Intermediate coat -- without -- -- without -- charge 1--component acrylate--alkyd compound, approx. Finish coat -- without -- 0.04 mm, water--thinned, RAL 5002 ultra- marine blue 1) not approved for drinking water applications 2) maximum permissible temperature 80 C. Not suited for outdoor installation Type B) Special surface coating Duplex Coating Interior 1) Exterior (ZN 35 ES1N A1--4) 3) Preparatory treatment Grease--free / blasting SA1 Grease--free / blasting SA1 B Against extra Primer 1--component anti--rust primer charge, as per price list Intermediate coat -- without -- Finish coat -- without -- 1) not approved for drinking water applications 3) maximum permissible temperature 150 C. Weatherproof; suited for industrial and marine atmospheres Type C) Surface coating at customer s option C upon request 2--component epoxy zinc dust, approx. 0.04 mm 2--component epoxy resin (EG1), approx. 0.06 mm 2--component polyurethane coating, approx. 0.04 mm, RAL 5002 ultramarine blue Coating Interior 1) Exterior Preparatory treatment Grease--free / blasting SA1 Blasting SA 2 1/2, DIN EN ISO 12944--4 Primer 1--component anti--rust primer Intermediate coat -- without -- Finish coat -- without -- 2--component epoxy zinc dust, approx. 0.04 mm Coating according to customer specification or by customer Coating according to customer specification or by customer 1) not approved for drinking water applications Option interior coating approved for drinking water applications Coating Interior (ZN 35 EST A1--3) 4) Exterior Preparatory treatment Blasting SA 2 1/2, DIN EN ISO 12944--4 Blasting SA 2 1/2, DIN EN ISO 12944--4 Against extra charge, as per price list Primer 2--component epoxy resin compound, approx. 0.125 mm, RAL 7032 pebble grey, (Icosit TW3) Intermediate coat -- without -- Finish coat 2--component epoxy resin compound, approx. 0.125 mm, RAL 7032 pebble grey, (Icosit TW3) 2--component epoxy zinc dust, approx. 0.04 mm Coating according to customer specification or by customer Coating according to customer specification or by customer

RDLO / RDLO V Arrangement of Sealing and Flushing Pipe RDLO, clean water operation RDLO, waste water operation RDLO V, clean water operation RDLO V, waste water operation (Vent and drain valves available as accessories) 1387.5/2--10 Subject to technical modifications 11

RDLO Sectional Drawing (horizontal design) Part No. Description Part No. Description Part No. Description 102 Volute casing 412 O--ring 524 Shaft protecting sleeve 145 Adapter 441 Shaft seal housing 525 Spacer sleeve 211 Pump shaft 452 Gland 550 Disc 234 Double--entry impeller 457 Neck ring 636 Grease nipple 320 Angular contact ball 458 Lantern ring 680 Guard bearing 321 Deep groove ball bearing 461 Packing ring 840 Coupling 350 Bearing housing 500 Ring 920 Nut 360 Bearing cover 502 Casing wear ring 932 Circlip 411 V--ring 520 Sleeve 950 Disc spring 12 Subject to technical modifications 1387.5/2--10

RDLO Options: oil lubrication, resistance thermometer PT 100 Part No. Description Part No. Description Part No. Description 211 Pump shaft 412 O--ring 672 Vent plug 320 Angular contact ball bearing 423 Labyrinth ring 692 Resistance thermometer 321 Deep groove ball bearing 520 Sleeve 920 Nut 350 Bearing housing 525 Spacer sleeve 932 Circlip 360 Bearing cover 550 Disc 950 Disc spring 411 V--ring 638 Constant level oiler 1387.5/2--10 Subject to technical modifications 13

RDLO V Sectional Drawing (vertical design) Part No. Description Part No. Description Part No. Description 102 Volute casing 430 Shaft seal 550 Disc 145 Adapter 441 Shaft seal housing 636 Grease nipple 211 Pump shaft 452 Gland 680 Guard 234 Double--entry impeller 457 Neck ring 840 Coupling 320 Angular contact ball 458 Lantern ring 891 Baseplate bearing 321 Deep groove ball bearing 461 Packing ring 893 Soleplate 350 Bearing housing 502 Casing wear ring 920 Nut 360 Bearing cover 520 Sleeve 932 Circlip 411 V--ring 524 Shaft protecting sleeve 950 Disc spring 412 O--ring 525 Spacer sleeve 14 Subject to technical modifications 1387.5/2--10

RDLO V Detail of bottom bearing Part No. Description 321 Deep groove ball bearing 350 Bearing housing 360 Bearing cover 430 Shaft seal 520 Sleeve 550 Disc 636 Grease nipple 920 Nut 950 Disc spring Option: Product -lubricated Plain Bearing Part No. Description 160 Cover 350 Bearing housing 412 O--ring 524 Shaft protecting sleeve 525 Spacer sleeve 545 Bearing bush 550 Disc 920 Nut 950 Disc spring 1387.5/2--10 Subject to technical modifications 15

RDLO / RDLO V Option: Gland Packing 7bar Part No. Description 211 Pump shaft 441 Shaft seal housing 452 Gland 457 Neck ring 461 Packing ring 524 Shaft protecting sleeve Option: Mechanical Seal (balanced) Part No. Description 211 Pump shaft 412 O--ring 433 Mechanical seal 441 Shaft seal housing 457 Neck ring 471 Seal cover 524 Shaft protecting sleeve Option: Impeller with impeller wear ring Part No. Description 234 Double--entry impeller 502 Casing wear ring 503 Impeller wear ring 904 Grub screw 16 Subject to technical modifications 1387.5/2--10

RDLO / RDLO V Noise Characteristics for Pumps without Motor Sound pressure level L pa 92 n = 1480 min - 1 n = 1780 min - 1 87 LpA [db] 82 n = 715 min - 1 n = 740 min - 1 77 n = 985 min - 1 n = 1180 min - 1 72 100 1000 10000 Nominal power input PN [kw] Measurement Surface Ratio L s Sound Power Level L WA : Pump size L S [db] 350--575 350--690 L WA =L pa +L S [db] 400--525 16 400--705 500--585 400--665 400--935 500--685 500--835 500--860 17 500--1015 500--1035 600--600 600--705 600--885 600--1075 18 700--980 Standardised Octave Spectrum: Speed [min -- 1 ] Octave centre frequency 63 125 250 500 1000 2000 4000 8000 950 -- 6 -- 3 0 -- 2 -- 4 -- 8 -- 12 -- 16 up to 2000 -- 4 -- 3 -- 2 -- 1 -- 4 -- 8 -- 12 -- 16 1387.5/2--10 Subject to technical modifications 17

RDLO Dimension Table RDLO 350-575 bis 400-935 Direction of rotation of pump: CLOCKWISE Connections: -- 1M Pressure gauge G 1/2 -- 6D Vent G 1 -- 6B Drain G 1 -- 8B Leakage G 1/2 -- 9A Sealing liquid outlet G 1 -- 9E Sealing liquid inlet G 1/2 -- 9D Sealing liquid vent G 1 Dimensions and Weights Nominal diameters Pump dimensions DN 1 DN 2 d 1 l 1 a 1 a 2 f h 1 h 2 h 3 l 2 l 3 z 1) 350--575 900 700 400 350 95 956 720 1676 350--690 750 900 475 550 1100 400--525 750 700 105 210 998 747 1745 400--665 1000 750 1000 525 620 1240 500 400 400--705 900 800 900 450 570 1140 95 956 720 1676 400--935 1050 1000 1000 550 650 1300 Foot dimensions Weights in kg Dimensional b 1 d 3 m 1 m 2 n 1 n 2 n 3 n 4 s Pump Water fill drawing 350--575 2600 300 UA7 3030401 780 630 350--690 2750 370 UA7 3030501 560 560 485 485 400--525 2400 475 UA7 3030701 150 35 890 740 35 400--665 3200 550 UA7 3030801 400--705 750 630 2800 500 UA7 3030601 640 640 565 565 400--935 840 690 3100 600 UA7 3077201 1) z = clear height above the casing cover required for removing the rotor 18 Subject to technical modifications 1387.5/2--10

RDLO Standard bolt hole patterns for flanges Cast iron Nominal pressure to: Nodular cast iron / Ni--Resist Nominal pressure to: DIN EN 1092--2 ASME B16.1 DIN 2543 DIN 2544 ASME B16.5 350--575 350--690 Class 125 + 250 Class 150 + 300 400--525 Class 125 Class 150 PN 10 + PN 16 PN 16 PN 25 400--665 400--705 Class 125 + 250 Class 150 + 300 400--935 Flange dimensions RDLO 350-575 and 350-690 Suction side Discharge side Code / Nominal DN 400 DN 350 Standard pressure s 1 d 2 k n s 2 d 2 k n DIN EN 1092--2 2 PN 10 32 28 515 30 23 460 16 PN 16 38 31 525 36 28 470 16 DIN 2543 PN 16 32 30 525 16 30 26 470 16 DIN 2544 PN 25 40 36 550 16 38 33 490 16 ASME B16.11 Class 125 38 29 540 16 37 29 476 12 Class 250 58 35 572 20 54 32 514 20 ASME B16.5 Class 150 37 29 540 16 35 29 476 12 Class 300 58 35 572 20 54 32 514 20 RDLO 400-525 to 400-935 Suction side Discharge side Code / Nominal DN 500 DN 400 Standard pressure s 1 d 2 k n s 2 d 2 k n DIN EN 1092--2 2 PN 10 34 28 620 32 28 515 20 PN 16 42 34 650 38 31 525 16 DIN 2543 PN 16 36 33 650 20 32 30 525 16 DIN 2544 PN 25 44 36 660 20 40 36 550 16 ASME B16.11 Class 125 45 32 635 20 38 29 540 16 Class 250 64 35 686 24 58 35 572 20 ASME B16.5 Class 150 43 32 635 20 37 29 540 16 Class 300 64 35 686 24 58 35 572 20 d 2 k No.ofholesn Item No. Plant Dimension Table RDLO - Offer No. / Works No. No. Date Name Modification 1387.5/2--10 Subject to technical modifications 19

RDLO Dimension Table RDLO 500-585 to 500-1035 Direction of rotation of pump: CLOCKWISE Connections: -- 1M Pressure gauge G 1/2 -- 6D Vent G 1 -- 6B Drain G 1 -- 8B Leakage G 1/2 -- 9A Sealing liquid outlet G 1 -- 9E Sealing liquid inlet G 1/2 -- 9D Sealing liquid vent G 1 Dimensions and Weights Nominal Shaft diameters Pump dimensions DN 1 DN 2 d 1 l 1 a 1 a 2 f h 1 h 2 h 3 l 2 l 3 z 1) 500--585 550 680 1360 105 210 1100 800 1098 847 1945 500--685 1100 670 1340 575 500--835 1150 1100 690 1380 600 500 500--860 900 700 775 1550 125 250 1200 1166 872 2038 500--1015 1200 725 750 1500 1100 500--1035 1250 700 800 1600 Foot dimensions Weights in kg Dimensional b 1 d 3 m 1 m 2 n 1 n 2 n 3 n 4 s Pump Water fill drawing 500--585 4400 490 UA7 3030901 150 35 1050 900 640 640 565 565 35 500--685 4300 700 UA7 3031001 500--835 850 850 750 750 4760 800 UA7 3042101 500--860 725 725 625 625 5000 1000 UA7 3042301 200 42 1070 870 40 500--1015 5500 1100 UA7 3042201 850 850 750 750 500--1035 5680 1310 UA7 3042401 1) z = clear height above the casing cover required for removing the rotor 20 Subject to technical modifications 1387.5/2--10

RDLO Standard bolt hole patterns for flanges Cast iron Nominal pressure to: Nodular cast iron / Ni--Resist Nominal pressure to: DIN EN 1092--2 ASME B16.1 DIN 2543 DIN 2544 ASME B16.5 500--585 PN 10 Class 125 PN 10 -- Class 150 500--685 -- 500--835 500--860 PN 10 + PN 16 Class 125 + 250 PN 16 500--1015 500--1035 PN 25 Class 150 + 300 d 2 k No.ofholesn Flange dimensions Suction side Discharge side Code / Nominal DN 600 DN 500 Standard pressure s 1 d 2 k n s 2 d 2 k n DIN EN 1092--2 2 PN 10 36 31 725 34 28 620 20 PN 16 48 37 770 42 34 650 20 DIN 2543 PN 16 40 36 770 20 36 33 650 20 DIN 2544 PN 25 46 39 770 20 44 36 660 20 ASME B16.11 Class 125 48 35 749 20 45 32 635 20 Class 250 70 42 813 24 64 35 686 24 ASME B16.5 Class 150 48 35 749 20 43 32 635 20 Class 300 70 42 813 24 64 35 686 24 Item No. Plant Dimension Table RDLO - Offer No. / Works No. No. Date Name Modification 1387.5/2--10 Subject to technical modifications 21

RDLO Dimension Table RDLO 600-600 to 700-980 Direction of rotation of pump: CLOCKWISE Connections: -- 1M Pressure gauge G 1/2 -- 6D Vent G 1 -- 6B Drain G 1 -- 8B Leakage G 1/2 -- 9A Sealing liquid outlet G 1 -- 9E Sealing liquid inlet G 1/2 -- 9D Sealing liquid vent G 1 Dimensions and Weights Nominal diameters Shaft Pump dimensions DN 1 DN 2 d 1 l 1 a 1 a 2 f h 1 h 2 h 3 l 2 l 3 z 1) 600--600 1200 900 1200 675 770 1540 105 210 1098 847 1945 600--705 1150 1000 1100 575 715 1430 700 600 600--885 1300 1100 790 1580 1280 1300 750 926 2206 600--1075 145 290 1250 1200 850 1700 700--980 800 700 1300 1050 1365 1500 850 930 1011 2376 1800 Foot dimensions Weights in kg b 1 d 3 m 1 m 2 n 1 n 2 n 3 n 4 s Pump Water fill Dimensional drawing 600--600 1070 4900 1300 UA7 3042501 35 725 725 625 625 600--705 1090 870 4700 1300 UA7 3042601 600--885 200 1070 40 5600 1500 UA7 3042701 600--1075 42 1150 950 850 850 750 750 5800 1800 UA7 3042801 700--980 1340 1140 7700 2000 UA7 3030301 1) z = clear height above the casing cover required for removing the rotor 22 Subject to technical modifications 1387.5/2--10

RDLO Standard bolt hole patterns for flanges Cast iron Nominal pressure to: Nodular cast iron / Ni--Resist Nominal pressure to: DIN EN 1092--2 ASME B16.1 1) DIN 2543 DIN 2544 ASME B16.5 1) 600--600 PN 10 Class 125 PN 10 600--705 -- Class 150 600--885 PN 10 + PN 16 Class 125 + 250 PN 16 600--1075 PN 25 Class 150 + 300 700--980 -- 1) Bolt hole pattern for DN 700 and above according to MSS SP44 and/or ASME B 16.47 Series A Flange dimensions RDLO 600-600 to 600-1075 Suction side Discharge side Code / Nominal DN 700 DN 600 Standard pressure s 1 d 2 k n s 2 d 2 k n DIN EN 1092--2 2 PN 10 40 31 36 31 725 840 24 PN 16 54 37 48 37 770 20 DIN 2543 PN 16 42 36 840 24 40 36 770 20 DIN 2544 PN 25 50 42 875 24 46 39 770 20 ASME B16.11 Class 125 48 35 749 20 -- -- -- -- Class 250 70 42 813 24 ASME B16.5 Class 150 48 35 749 20 -- -- -- -- Class 300 70 42 813 24 MSS SP44 Class 150 54 35 864 -- -- -- -- 28 Class 300 75 45 940 -- -- -- -- d 2 k No.ofholesn RDLO 700-980 Suction side Discharge side Code / Nominal DN 800 DN 700 Standard pressure s 1 d 2 k n s 2 d 2 k n DIN EN 1092--2 2 PN 10 44 34 40 31 950 24 PN 16 58 41 54 37 840 24 DIN 2543 PN 16 42 39 950 24 42 36 840 24 DIN 2544 PN 25 54 48 990 24 50 42 875 24 MSS SP44 Class 150 59 41 978 54 35 864 28 Class 300 78 51 1054 75 45 940 28 Item No. Plant Dimension Table RDLO - Offer No. / Works No. No. Date Name Modification 1387.5/2--10 Subject to technical modifications 23

RDLO V Dimension Table RDLO V 350-575 to 400-935 Connections: -- 1M Pressure gauge G 1/2 -- 6D Vent G 1 -- 6B Drain G 1 -- 9A Sealing liquid outlet G 1 -- 9E Sealing liquid inlet G 1/2 -- 8A1 Leakage G 1/2 -- 8A2 Leakage G1 Direction of rotation of pump: CLOCKWISE Dimensions and Weights Nominal diameters Shaft Pump dimensions DN 1 DN 2 d 1 l 1 a 1 a 2 h 2 h 3 h 4 h 5 350--575 700 400 350 95 900 350--690 750 475 550 880 1841 400--525 750 700 105 210 915 1918 400--665 1000 750 525 620 500 400 400--705 900 800 450 570 875 1836 95 400--935 1050 1000 550 650 880 1841 Foot dimensions Weights in kg Dimensional Baseplate m 3 m 4 m 5 m 6 m 7 n 5 n 6 n 7 n 8 n 9 Pump Water fill drawing 350--575 2600 300 UA73043401 350--690 965 915 255 345 2750 370 UA73043501 400--525 2400 475 UA73043701 1340 1530 1130 1100 900 525 255 400--665 1065 1015 355 245 3200 550 UA73043801 400--705 965 915 255 345 2800 500 UA73043601 400--935 1065 1015 355 245 3100 600 UA73077101 24 Subject to technical modifications 1387.5/2--10

RDLO V Standard bolt hole patterns for flanges Cast iron Nominal pressure to: Nodular cast iron / Ni--Resist Nominal pressure to: DIN EN 1092--2 ASME B16.1 DIN 2543 DIN 2544 ASME B16.5 350--575 350--690 Class 125 + 250 Class 150 + 300 400--525 Class 125 Class 150 PN 10 + PN 16 PN 16 PN 25 400--665 400--705 Class 125 + 250 Class 150 + 300 400--935 Flange dimensions RDLO 350-575 and 350-690 Suction side Discharge side Code / Nominal DN 400 DN 350 Standard pressure s 1 d 2 k n s 2 d 2 k n DIN EN 1092--2 2 PN 10 32 28 515 30 23 460 16 PN 16 38 31 525 36 28 470 16 DIN 2543 PN 16 32 30 525 16 30 26 470 16 DIN 2544 PN 25 40 36 550 16 38 33 490 16 ASME B16.11 Class 125 38 29 540 16 37 29 476 12 Class 250 58 35 572 20 54 32 514 20 ASME B16.5 Class 150 37 29 540 16 35 29 476 12 Class 300 58 35 572 20 54 32 514 20 RDLO 400-525 to 400-935 Suction side Discharge side Code / Nominal DN 500 DN 400 Standard pressure s 1 d 2 k n s 2 d 2 k n DIN EN 1092--2 2 PN 10 34 28 620 32 28 515 20 PN 16 42 34 650 38 31 525 16 DIN 2543 PN 16 36 33 650 20 32 30 525 16 DIN 2544 PN 25 44 36 660 20 40 36 550 16 ASME B16.11 Class 125 45 32 635 20 38 29 540 16 Class 250 64 35 686 24 58 35 572 20 ASME B16.5 Class 150 43 32 635 20 37 29 540 16 Class 300 64 35 686 24 58 35 572 20 d 2 k No.ofholesn Item No. Plant Dimension Table RDLO V - Offer No. / Works No. No. Date Name Modification 1387.5/2--10 Subject to technical modifications 25

RDLO V Dimension Table RDLO V 500-585 to 500-1035 Connections: -- 1M Pressure gauge G 1/2 -- 6D Vent G 1 -- 6B Drain G 1 -- 9A Sealing liquid outlet G 1 -- 9E Sealing liquid inlet G 1/2 -- 8A1 Leakage G 1/2 -- 8A2 Leakage G1 Direction of rotation of pump: CLOCKWISE Dimension and Weights Nominal diameters Shaft Pump dimensions DN 1 DN 2 d 1 l 1 a 1 a 2 h 2 h 3 h 4 h 5 500--585 550 680 105 210 1100 800 1015 2113 500--685 670 575 500--835 1150 1100 690 600 500 500--860 900 700 775 125 250 1200 1000 2166 500--1015 725 750 1100 500--1035 1250 700 800 Foot dimensions Weights in kg Dimensional Baseplate m 3 m 4 m 5 m 6 m 7 n 5 n 6 n 7 n 8 n 9 Pump Water fill drawing 500--585 4400 490 UA73043901 1650 1250 525 276 500--685 1165 1115 355 365 4300 700 UA73044001 500--835 4760 800 UA73076201 1560 1100 900 500--860 5000 1000 UA73076401 1900 1500 580 292 500--1015 1265 1215 455 265 5500 1100 UA73076301 500--1035 5680 1310 UA73076501 26 Subject to technical modifications 1387.5/2--10

RDLO V Standard bolt hole patterns for flanges Cast iron Nominal pressure to: Nodular cast iron / Ni--Resist Nominal pressure to: DIN EN 1092--2 ASME B16.1 DIN 2543 DIN 2544 ASME B16.5 500--585 PN 10 Class 125 PN 10 -- Class 150 500--685 -- 500--835 500--860 PN 10 + PN 16 Class 125 + 250 PN 16 500--1015 500--1035 PN 25 Class 150 + 300 d 2 k No.ofholesn Flange dimensions Suction side Discharge side Code / Nominal DN 600 DN 500 Standard pressure s 1 d 2 k n s 2 d 2 k n DIN EN 1092--2 2 PN 10 36 31 725 34 28 620 20 PN 16 48 37 770 42 34 650 20 DIN 2543 PN 16 40 36 770 20 36 33 650 20 DIN 2544 PN 25 46 39 770 20 44 36 660 20 ASME B16.11 Class 125 48 35 749 20 45 32 635 20 Class 250 70 42 813 24 64 35 686 24 ASME B16.5 Class 150 48 35 749 20 43 32 635 20 Class 300 70 42 813 24 64 35 686 24 Item No. Plant Dimension Table RDLO V - Offer No. / Works No. No. Date Name Modification 1387.5/2--10 Subject to technical modifications 27

RDLO V Dimension Table RDLO V 600-600 to 700-980 Connections: -- 1M Pressure gauge G 1/2 -- 6D Vent G 1 -- 6B Drain G 1 -- 9A Sealing liquid outlet G 1 -- 9E Sealing liquid inlet G 1/2 -- 8A1 Leakage G 1/2 -- 8A2 Leakage G1 Direction of rotation of pump: CLOCKWISE Dimensions and Weights Nominal diameters Shaft Pump dimensions DN 1 DN 2 d 1 l 1 a 1 a 2 h 2 h 3 h 4 h 5 600--600 1200 900 675 770 105 210 1015 2113 600--705 1150 1000 575 715 700 600 600--885 1300 1100 790 750 1040 2320 600--1075 145 290 1250 1200 850 700--980 800 700 1300 1050 850 930 1125 2490 Foot dimensions Weights in kg Dimensional Baseplate m 3 m 4 m 5 m 6 m 7 n 5 n 6 n 7 n 8 n 9 Pump Water fill drawing 600--600 1265 1215 455 265 4900 1300 UA73076601 1560 1650 1250 525 273 600--705 1165 1115 355 365 4700 1300 UA73076701 600--885 1100 900 5600 1500 UA73076801 1365 1315 270 480 600--1075 1875 1900 1500 580 5800 1800 310 UA73076901 700--980 1565 1515 470 280 7700 2000 UA73043301 28 Subject to technical modifications 1387.5/2--10

RDLO V Standard bolt hole patterns for flanges Cast iron Nominal pressure to: Nodular cast iron / Ni--Resist Nominal pressure to: DIN EN 1092--2 ASME B16.1 1) DIN 2543 DIN 2544 ASME B16.5 1) 600--600 PN 10 Class 125 PN 10 600--705 -- Class 150 600--885 PN 10 + PN 16 Class 125 + 250 PN 16 600--1075 PN 25 Class 150 + 300 700--980 -- 1) Bolt hole pattern for DN 700 and above according to MSS SP44 and/or ASME B 16.47 Series A Flange dimensions RDLO 600-600 to 600-1075 Suction side Discharge side Code / Nominal DN 700 DN 600 Standard pressure s 1 d 2 k n s 2 d 2 k n DIN EN 1092--2 2 PN 10 40 31 36 31 725 840 24 PN 16 54 37 48 37 770 20 DIN 2543 PN 16 42 36 840 24 40 36 770 20 DIN 2544 PN 25 50 42 875 24 46 39 770 20 ASME B16.11 Class 125 48 35 749 20 -- -- -- -- Class 250 70 42 813 24 ASME B16.5 Class 150 48 35 749 20 -- -- -- -- Class 300 70 42 813 24 MSS SP44 Class 150 54 35 864 -- -- -- -- 28 Class 300 75 45 940 -- -- -- -- d 2 k No.ofholesn RDLO 700-980 Suction side Discharge side Code / Nominal DN 800 DN 700 Standard pressure s 1 d 2 k n s 2 d 2 k n DIN EN 1092--2 2 PN 10 44 34 40 31 950 24 PN 16 58 41 54 37 840 24 DIN 2543 PN 16 42 39 950 24 42 36 840 24 DIN 2544 PN 25 54 48 990 24 50 42 875 24 MSS SP44 Class 150 59 41 978 54 35 864 28 Class 300 78 51 1054 75 45 940 28 Item No. Plant Dimension Table RDLO V - Offer No. / Works No. No. Date Name Modification 1387.5/2--10 Subject to technical modifications 29

RDLO General Arrangement Drawing RDLO 350-575 to 400-935 Type of installation 2E Direction of rotation of pump CLOCKWISE Top layer concrete Connecting flange: -- All flanges are designed as plate flanges -- Connect the pipes without transmitting any stresses or strains Permissible forces and moments acting on the pump nozzles, see table on page 9 For the position of the terminal box please refer to the motor dimensional drawing Dimensions and Weights *) Nominal diameters Pump set dimensions DN 1 DN 2 a 1 a 2 f h 1 h 2 h 3 350--575 700 400 350 900 956 350--690 750 900 475 550 400--525 750 700 998 400--665 1000 750 1000 525 620 500 400 400--705 900 800 900 450 570 956 400--935 1050 1000 1000 550 650 Pump set dimensions Weights in kg h 12 h 13 h 14 l 2 q l 7 m 1 z 1) Pump Water fill Motor 350--575 1135 500 400 2345 4026 2600 300 5200 720 780 350--690 1250 560 340 2600 4281 1100 2750 370 7000 400--525 1135 500 400 2345 4095 2400 475 5500 747 890 400--665 1250 560 440 2600 4350 1240 3200 550 7300 400--705 1050 450 450 2165 3846 750 1140 2800 500 3800 720 400--935 1250 560 440 2600 4281 840 1300 3100 600 8100 *) Dimensional and weight deviations due to different motor manufacturers/types must be taken into account 1) z = clear height above the casing cover required for removing the rotor 30 Subject to technical modifications 1387.5/2--10

RDLO Standard bolt hole patterns for flanges Cast iron Nodular cast iron / Ni--Resist Nominal pressure to: Nominal pressure to: DIN EN 1092--2 ASME B16.1 DIN 2543 DIN 2544 ASME B16.5 350--575 350--690 Class 125 + 250 Class 150 + 300 400--525 Class 125 Class 150 PN 10 + PN 16 PN 16 PN 25 400--665 400--705 Class 125 + 250 Class 150 + 300 400--935 d 2 k No.ofholesn Flange dimensions Code / Standard DIN EN 1092--2 2 RDLO 350-575 and 350-690 RDLO 400-525 to 400-935 Suction side DN 400 Discharge side DN 350 Suction side DN 500 Discharge side DN 400 Nominal pressure s 1 d 2 k n s 2 d 2 k n s 1 d 2 k n s 2 d 2 k n PN 10 32 28 515 30 23 460 34 28 620 32 28 515 16 16 20 PN 16 38 31 525 36 28 470 42 34 650 38 31 525 16 DIN 2543 PN 16 32 30 525 16 30 26 470 16 36 33 650 20 32 30 525 16 DIN 2544 PN 25 40 36 550 16 38 33 490 16 44 36 660 20 40 36 550 16 ASME B16.11 Class 125 38 29 540 16 37 29 476 12 45 32 635 20 38 29 540 16 Class 250 58 35 572 20 54 32 514 20 64 35 686 24 58 35 572 20 ASME B16.5 Class 150 37 29 540 16 35 29 476 12 43 32 635 20 37 29 540 16 Class 300 58 35 572 20 54 32 514 20 64 35 686 24 58 35 572 20 Foundation Dimensions *) Foundation dimensions, pump Foundation rail BN 434 Part 2 b 7 b 8 b 9 I 8 I 9 t 1 t 2 350--575 730 1000 350--690 970 400--525 400 70 840 1100 200 140 A2 400--665 400--705 1130 730 1000 400--935 Foundation dimensions, motor Foundation block DIN 799 b 10 b 11 I 10 I 11 t 3 Type A 850 220 1451 1250 450 M36 950 280 1526 1400 530 M42 850 220 1493 1250 450 M36 950 280 1568 1400 530 M42 750 180 1425 1120 360 M30 950 280 1526 1400 530 M42 *) Dimensional and weight deviations due to different motor manufacturers/types must be taken into account Item No. Plant General Arrangement Drawing RDLO - Offer No. / Works No. No. Date Name Modification 1387.5/2--10 Subject to technical modifications 31

RDLO General Arrangement Drawing RDLO 500-585 to 500-1035 Type of installation 2E Direction of rotation of pump CLOCKWISE Top layer concrete Connecting flange: -- All flanges are designed as plate flanges -- Connect the pipes without transmitting any stresses or strains Permissible forces and moments acting on the pump nozzles, see table on page 9 For the position of the terminal box please refer to the motor dimensional drawing Dimensions and Weights *) Nominal diameters Pump set dimensions DN 1 DN 2 a 1 a 2 f h 1 h 2 h 3 500--585 550 680 1100 800 1098 500--685 1100 670 575 500--835 1150 1100 690 600 500 500--860 900 700 775 1200 1166 500--1015 1200 725 750 1100 500--1035 1250 700 800 Pump set dimensions Weights in kg h 12 h 13 h 14 l 2 q l 7 m 1 z 1) Pump Water fill Motor 500--585 1135 500 600 2385 4335 1360 4400 490 5100 847 1050 500--685 1250 2600 4550 1340 4300 700 7500 540 500--835 1380 4760 800 8100 2950 4993 500--860 560 1070 1550 5000 1000 8650 2260 872 500--1015 640 1500 5500 1100 3180 5223 10050 500--1035 1600 5680 1310 *) Dimensional and weight deviations due to different motor manufacturers/types must be taken into account 1) z = clear height above the casing cover required for removing the rotor 32 Subject to technical modifications 1387.5/2--10

RDLO Standard bolt hole patterns for flanges Cast iron Nominal pressure to: Nodular cast iron / Ni--Resist Nominal pressure to: DIN EN 1092--2 ASME B16.1 DIN 2543 DIN 2544 ASME B16.5 500--585 PN 10 Class 125 PN 10 -- Class 150 500--685 -- 500--835 500--860 PN 10 + PN 16 Class 125 + 250 PN 16 500--1015 500--1035 PN 25 Class 150 + 300 d 2 k No.ofholesn Flange dimensions Suction side Discharge side Code / Nominal DN 600 DN 500 Standard pressure s 1 d 2 k n s 2 d 2 k n DIN EN 1092--2 2 PN 10 36 31 725 34 28 620 20 PN 16 48 37 770 42 34 650 20 DIN 2543 PN 16 40 36 770 20 36 33 650 20 DIN 2544 PN 25 46 39 770 20 44 36 660 20 ASME B16.11 Class 125 48 35 749 20 45 32 635 20 Class 250 70 42 813 24 64 35 686 24 ASME B16.5 Class 150 48 35 749 20 43 32 635 20 Class 300 70 42 813 24 64 35 686 24 Foundation Dimensions *) Foundation dimensions, pump Foundation dimensions, pump Foundation Foundation rail block BN 434 Part 2 DIN 799 b 7 b 8 b 9 I 8 I 9 t 1 t 2 b 10 b 11 I 10 I 11 t 3 Type A 500--585 850 220 1633 1250 450 M36 1130 400 1000 A2 500--685 950 1668 500--835 1500 1400 70 1300 200 140 500--860 1250 280 530 M42 500 970 A4 1060 1726 500--1015 1500 1600 500--1035 *) Dimensional and weight deviations due to different motor manufacturers/types must be taken into account Item No. Plant General Arrangement Drawing RDLO - Offer No. / Works No. No. Date Name Modification 1387.5/2--10 Subject to technical modifications 33

RDLO General Arrangement Drawing RDLO 600-600 to 700-980 Type of installation 2E Direction of rotation of pump CLOCKWISE Top layer concrete Connecting flange: -- All flanges are designed as plate flanges -- Connect the pipes without transmitting any stresses or strains Permissible forces and moments acting on the pump nozzles, see table on page 9 For the position of the terminal box please refer to the motor dimensional drawing Dimensions and Weights *) Nominal diameters Pump set dimensions DN 1 DN 2 a 1 a 2 f h 1 h 2 h 3 600--600 1200 900 1200 675 770 1098 600--705 1150 1000 1100 575 715 700 600 600--885 1300 1100 790 1280 1300 750 600--1075 1250 1200 850 700--980 800 700 1300 1050 1365 1500 850 930 Pump set dimensions Weights in kg h 12 h 13 h 14 l 2 q l 7 m 1 z 1) Pump Water fill Motor 600--600 1135 500 700 2385 4335 1070 1540 4900 1300 5100 847 600--705 1250 540 2600 4550 1090 1430 4700 1300 8100 600--885 600--1075 2260 560 926 740 2950 5161 1070 1580 5600 1500 8650 5391 1150 1700 5800 1800 700--980 940 1011 3180 5561 1340 1800 7700 2000 *) Dimensional and weight deviations due to different motor manufacturers/types must be taken into account 1) z = clear height above the casing cover required for removing the rotor 10050 34 Subject to technical modifications 1387.5/2--10

RDLO Standard bolt hole patterns for flanges Cast iron Nodular cast iron / Ni--Resist Nominal pressure to: Nominal pressure to: DIN EN 1092--2 ASME B16.1 1) DIN 2543 DIN 2544 ASME B16.5 1) 600--600 PN 10 Class 125 PN 10 600--705 -- Class 150 600--885 PN 10 + PN 16 Class 125 + 250 PN 16 600--1075 PN 25 Class 150 + 300 700--980 -- 1) Bolt hole pattern for DN 700 and above according to MSS SP44 and/or ASME B16.47 Series A d 2 k No.ofholesn Flange dimensions Code / Standard DIN EN 1092--2 2 RDLO 600-600 to 600-1075 RDLO 700-980 Suction side DN 700 Discharge side DN 600 Suction side DN 800 Discharge side DN 700 Nom s 1 d 2 k n s 2 d 2 k n s 1 d 2 k n s 2 d 2 k n PN 10 40 31 36 31 725 44 34 40 31 840 24 20 950 24 840 24 PN 16 54 37 48 37 770 58 41 54 37 DIN 2543 PN 16 42 36 840 24 40 36 770 20 42 39 950 24 42 36 840 24 DIN 2544 PN 25 50 42 875 24 46 39 770 20 54 48 990 24 50 42 875 24 ASME B16.11 Class 125 48 35 749 20 -- -- -- -- Class 250 70 42 813 24 -- -- -- -- -- -- -- -- ASME B16.5 Class 150 48 35 749 20 -- -- -- -- Class 300 70 42 813 24 -- -- -- -- -- -- -- -- MSS SP44 Class 150 54 35 864 -- -- -- -- 59 41 978 54 35 864 28 28 Class 300 75 45 940 -- -- -- -- 78 51 1054 75 45 940 28 Foundation Dimensions *) Foundation dimensions, pump Foundation dimensions, motor Foundation Foundation rail block BN 434 Part 2 DIN 799 b 7 b 8 b 9 I 8 I 9 t 1 t 2 b 10 b 11 I 10 I 11 t 3 Type A 600--600 850 220 1633 1250 450 M36 1250 600--705 970 1300 950 1668 1400 600--885 500 70 200 140 A4 280 1840 530 M42 600--1075 1500 1050 1400 1060 1600 700--980 1240 1600 1925 *) Dimensional and weight deviations due to different motor manufacturers/types must be taken into account Item No. Plant General Arrangement Drawing RDLO - Offer No. / Works No. No. Date Name Modification 1387.5/2--10 Subject to technical modifications 35

RDLO General Arrangement Drawing RDLO 350-575 to 400-935 Type of installation 3E Direction of rotation of pump CLOCKWISE Top layer concrete Connecting flange: -- All flanges are designed as plate flanges -- Connect the pipes without transmitting any stresses or strains Permissible forces and moments acting on the pump nozzles, see table on page 9 After aligning grout the baseplate with non--shrinking concrete! For the position of the terminal box please refer to the motor dimensional drawing Where appropriate, the pump sets are assembled completely at the factory in order tocheck them for proper adjustment. Afterwards they are disassembled for shipping, and the components are dispatched separately. Dimensions *) Nominal diameters Pump set dimensions DN 1 DN 2 a 1 a 2 f h 1 h 2 h 3 h 8 h 9 h 10 350--575 700 400 350 900 956 350--690 750 900 475 550 1130 1680 400--525 750 700 998 230 400--665 1000 750 1000 525 620 1230 1850 500 400 400--705 900 800 900 450 570 1130 1700 400--935 1050 1000 956 1000 550 650 1230 1880 350--575 1765 350--690 1820 400--525 1765 170 400--665 1920 195 400--705 1730 400--935 1920 Pump set dimensions h 11 i l 2 q l 7 m 1 w 1 z 1) 140 720 125 747 2345 4026 2600 4281 2345 4095 2600 4350 780 890 720 2165 3846 750 720 2600 4281 780 280 1100 252 1240 *) Dimensional and weight deviations due to different motor manufacturers/types must be taken into account 1) z = clear height above the casing cover required for removing the rotor 295 1140 1300 36 Subject to technical modifications 1387.5/2--10

RDLO Standard bolt hole patterns for flanges Cast iron Nodular cast iron / Ni--Resist Nominal pressure to: Nominal pressure to: DIN EN 1092--2 ASME B16.1 DIN 2543 DIN 2544 ASME B16.5 350--575 350--690 Class 125 + 250 Class 150 + 300 400--525 Class 125 Class 150 PN 10 + PN 16 PN 16 PN 25 400--665 400--705 Class 125 + 250 Class 150 + 300 400--935 d 2 k No.ofholesn Flange dimensions Code / Standard DIN EN 1092--2 2 RDLO 350-575 and 350-690 RDLO 400-525 to 400-935 Suction side DN 400 Discharge side DN 350 Suction side DN 500 Discharge side DN 400 Nominal pressure s 1 d 2 k n s 2 d 2 k n s 1 d 2 k n s 2 d 2 k n PN 10 32 28 515 30 23 460 34 28 620 32 28 515 16 16 20 PN 16 38 31 525 36 28 470 42 34 650 38 31 525 16 DIN 2543 PN 16 32 30 525 16 30 26 470 16 36 33 650 20 32 30 525 16 DIN 2544 PN 25 40 36 550 16 38 33 490 16 44 36 660 20 40 36 550 16 ASME B16.11 Class 125 38 29 540 16 37 29 476 12 45 32 635 20 38 29 540 16 Class 250 58 35 572 20 54 32 514 20 64 35 686 24 58 35 572 20 ASME B16.5 Class 150 37 29 540 16 35 29 476 12 43 32 635 20 37 29 540 16 Class 300 58 35 572 20 54 32 514 20 64 35 686 24 58 35 572 20 Foundation Dimensions and Weights *) Foundation dimensions Weights in kg b 4 b 5 b 6 l 4 l 5 l 6 t Pump Water fill Motor 350--575 950 3450 2600 300 5200 813 350--690 800 3760 2750 370 7000 827 1200 400--525 950 3450 2400 475 5500 813 200 100 300 320 400--665 800 3760 3200 550 7300 924 400--705 875 3230 2800 500 3800 826 1320 400--935 800 3760 3100 600 8100 945 *) Dimensional and weight deviations due to different motor manufacturers/types must be taken into account Baseplate Item No. Plant General Arrangement Drawing RDLO - Offer No. / Works No. No. Date Name Modification 1387.5/2--10 Subject to technical modifications 37

RDLO General Arrangement Drawing RDLO 500-585 to 500-1035 Type of installation 3E Direction of rotation of pump CLOCKWISE Top layer concrete Connecting flange: -- All flanges are designed as plate flanges -- Connect the pipes without transmitting any stresses or strains Permissible forces and moments acting on the pump nozzles, see table on page 9 After aligning grout the baseplate with non--shrinking concrete! For the position of the terminal box please refer to the motor dimensional drawing Where appropriate, the pump sets are assembled completely at the factory in order to check them for proper adjustment. Afterwards they are disassembled for shipping, and the components are dispatched separately. Dimensions *) Nominal diameters Pump set dimensions DN 1 DN 2 a 1 a 2 f h 1 h 2 h 3 h 8 h 9 h 10 500--585 550 680 2010 1100 800 1098 500--685 1100 670 1330 2000 575 500--835 1150 1100 690 2020 600 500 500--860 900 700 775 230 2205 1200 1166 500--1015 1200 725 750 1430 2180 1100 500--1035 1250 700 800 2230 500--585 1965 500--685 2020 500--835 3030 500--860 500--1015 3130 500--1035 Pump set dimensions h 11 i l 2 q l 7 m 1 w 1 z 1) 275 847 285 872 2385 4335 2600 4550 2950 4993 3180 5223 1050 272 1070 287 *) Dimensional and weight deviations due to different motor manufacturers/types must be taken into account 1) z = clear height above the casing cover required for removing the rotor 1360 1340 1380 1550 1500 1600 38 Subject to technical modifications 1387.5/2--10

RDLO Standard bolt hole patterns for flanges Cast iron Nominal pressure to: Nodular cast iron / Ni--Resist Nominal pressure to: DIN EN 1092--2 ASME B16.1 DIN 2543 DIN 2544 ASME B16.5 500--585 PN 10 Class 125 PN 10 -- Class 150 500--685 -- 500--835 500--860 PN 10 + PN 16 Class 125 + 250 PN 16 500--1015 500--1035 PN 25 Class 150 + 300 d 2 k No.ofholesn Flange dimensions Suction side Discharge side Code / Nominal DN 600 DN 500 Standard pressure s 1 d 2 k n s 2 d 2 k n DIN EN 1092--2 2 PN 10 36 31 725 34 28 620 20 PN 16 48 37 770 42 34 650 20 DIN 2543 PN 16 40 36 770 20 36 33 650 20 DIN 2544 PN 25 46 39 770 20 44 36 660 20 ASME B16.11 Class 125 48 35 749 20 45 32 635 20 Class 250 70 42 813 24 64 35 686 24 ASME B16.5 Class 150 48 35 749 20 43 32 635 20 Class 300 70 42 813 24 64 35 686 24 Foundation Dimensions and Weights *) 500--585 500--685 Foundation dimensions Weights in kg b 4 b 5 b 6 l 4 l 5 l 6 t Pump Water fill Motor 1320 500--835 1740 500--860 1490 500--1015 500--1035 1740 200 100 300 Baseplate 800 3760 4400 490 5100 1051 860 4060 4300 700 7500 1082 800 3800 860 4060 320 4760 800 8100 1189 5000 1000 8650 1230 5500 1100 940 4350 5680 1310 10050 *) Dimensional and weight deviations due to different motor manufacturers/types must be taken into account 1378 1409 Item No. Plant General Arrangement Drawing RDLO - Offer No. / Works No. No. Date Name Modification 1387.5/2--10 Subject to technical modifications 39

RDLO General Arrangement Drawing RDLO 600-600 to 700-980 Type of installation 3E Direction of rotation of pump CLOCKWISE Top layer concrete Connecting flange: -- All flanges are designed as plate flanges -- Connect the pipes without transmitting any stresses or strains Permissible forces and moments acting on the pump nozzles, see table on page 9 After aligning grout the baseplate with non--shrinking concrete! For the position of the terminal box please refer to the motor dimensional drawing Where appropriate, the pump sets are assembled completely at the factory in order to check them for proper adjustment. Afterwards they are disassembled for shipping, and the components are dispatched separately. Dimensions *) Nominal diameters Pump set dimensions DN 1 DN 2 a 1 a 2 f h 1 h 2 h 3 h 8 h 9 h 10 600--600 1200 900 1200 675 770 1430 2200 1098 600--705 1150 1000 1100 575 715 1330 2045 700 600 600--885 1300 1100 230 2320 1280 1300 750 1530 600--1075 1250 1200 850 2380 700--980 800 700 1300 1050 1365 1500 850 930 1730 2660 600--600 2065 285 600--705 2020 295 600--885 600--1075 Pump set dimensions h 11 i l 2 q l 7 m 1 w 1 z 1) 3230 285 290 847 926 700--980 3430 370 1011 2385 4335 1070 262 1540 2600 4550 1090 252 1430 2950 5161 1070 341 1580 3180 5391 1150 336 1700 5561 1340 341 1800 *) Dimensional and weight deviations due to different motor manufacturers/types must be taken into account 1) z = clear height above the casing cover required for removing the rotor 40 Subject to technical modifications 1387.5/2--10