Agilent G4367A Auxiliary Electronic Pressure Control (Aux EPC) Module

Similar documents
Agilent 490 Micro GC Internal and External Mount Genie Filter Brackets

Agilent G3510A/G3511A Multimode Inlet

Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory

Agilent Multimode Inlet

Agilent 7697A Headspace Sampler

Agilent 7890 Series Gas Chromatograph

Installing an Auxiliary Pressure Control Module

Agilent G1554A On-Column Capillary Inlet with EPC

Installing an Auxiliary Pressure Control Module

Installing a Purged Packed (PP) Inlet

Installing a PTV Inlet

Installing the Flame Ionization Detector EPC Flow Control Manifold

Installing a PTV Inlet

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

Installation Note. Agilent Technologies E4440A Spectrum Analyzer Option BAB, APC 3.5 Input Connector Retrofit Kit

Installing a Purged Packed Inlet

Agilent N2763A Rack Mount Kit for 4000 X-Series Oscilloscopes

Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

Installing a Cool On-Column Inlet

Installation Guide. Flame Ionization Detector on a 6890 GC. Accessories G1561A, G1562A, G1591A, G1598A

Valve Box and Valve Accessories G4315A, G4316A, G4317A

Installation Guide. Purged Packed Inlet, Electronic Pneumatics Control on 6890 GC Accessory G1551A

Agilent N5470A Series Oscilloscope Rack Mount Kit

Installation Guide. Thermal Conductivity Detector on a 6850 GC Accessory G2623A

Installing the CO 2 Cryogenic Oven Cooling Kit

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

Installation instruction do88 Intercooler for Volvo S60 V70 XC70 S80 Turbo 00-09

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

Nickel Catalyst Tube on a 6820 GC, Accessory G4318A

Pellicon 2 and 3 Mini Holder. User Guide

Agilent G2738A Upstream Capillary Interface

HP Adjustable Depth Fixed Rail Kit Installation

Spare Parts List. PCB Separator MAESTRO 2/2M

Installation Guide. Heater Interface Cable for Mass Sensitive Detector Accessory G1590A

OPERATOR S MANUAL. 20-bu 3-Point Hitch Material Collection System. LP65048 Supplier ST /07/2017 English. North American Edition Printed in USA

AssayMAP 96AM Wash Station. Maintenance Guide

INSTALLATION INSTRUCTIONS FOR PCBM-36C CONVERSION KIT From Natural Gas to Propane/LP Gas

Deans Switch Microfluidics

Torque Module Installation and User Guide for model 250i Motorcycle Dynamometers.

Model MC-30D Impact Press. Operation & Maintenance Instructions

Agilent 1260 Infinity Manual Injector

Spare Parts List. Label Printer

Model MC-35 Impact Press. Operation & Maintenance Instructions

Model MC-21 Impact Press. Operation & Maintenance Instructions. Revised 9/20/07

Firstmate Installation Manual and User's Guide May, 2003

Agilent G2855A Deans Switching System

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

AssayMAP 96AM Wash Station. Maintenance Guide

Toro Sprayer Calibration Tool

Installation Note for Solvent Selection Valve Upgrade Kit (G1360A)

Box Plot Template. Sample 1 Sample 2 Sample 3 Sample 4 Sample 5 Sample Vertex42 LLC HELP. Q1 Q2-Q1 Q3-Q2 Řady1 Řady2

Agilent 1200 Series Manual Injector

series USER MANUAL

DODGE CUMMINS Arctic-Heat Grid Relocation Kit

Installation of the Whisper Quiet Built-in Air compressor in the SRI 8610C/310C GC

Quick Start Guide. This is only a quick start guide. A full wiring and installation manual is included in PCLink.

4-Ton Electric Log Splitter

Morgan Schaffer. Calisto Monitors. Maintenance. Presented by: Eric Thibodeau. Technical Support Specialist

Ford 7.3L SuperDuty Cold Air Intake

30100 Module Installation Guide L

Giving reliability and cost effectiveness a lift. EKKE-Bas single-girder and ZKKE-Bas double-girder overhead travelling cranes EKKE ZKKE.

TV Lift System Model L-75i Installation Instructions

analytical bulk flow distance FLOW level pressure temperature industrial communication

Dual Fueler CP3 Pump Kit Installation Guide for LB7

15100 Module Installation Guide Mercedes EPA07 w/dpf

MSD Boost Control Module PN 7763

HP Modular Cooling System 200/100 Options Installation Guide

Active Controlled Cooling System

For more information about Agilent Technologies services please visit our web site using the following URL

Agilent 7693A Automated Liquid Sampler

INSTALL GUIDE Ford F L

P-Series Installation

AGCO. Corn Header Manual d HEADSIGHT.COM

Aluminum Capacitors Standard C Snap-In

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

advanced FLOW engineering Instruction Manual P/N: / /

Advanced Netbook Charging Carts for 10 laptops or 20 netbooks

JD2800 Module Installation Guide

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

INSTALLATION INSTRUCTIONS PART NUMBER:

Flow Module. Instruction Manual. Flow Module

VLS SERIES Vibration Type Level Sensor

Worl d Standard, I nterna t i o n a l Qu a l i t y. Phihong EV Chargers Green power, Green Lifestyle

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard

Alpha Performance Ignition Management Kit Fitting Instructions. Kit K Ford Zetec 1800cc 16 Valve & Ford Zetec 2000cc 16 Valve

Aluminum Capacitors Standard - 85 C Snap-In

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

BIODEX SURGICAL C-ARM TABLES SERVICE MANUAL and and

DODGE CUMMINS Air-Boss CR Intake Plenum

ProMix Auto Color and Catalyst Change Kits

MSD Boost Control Module PN 77631

USER MANUAL EN 1~7 中 8~14 com

PLATINUM Series Haltech

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Installing the G2743A/G2745A Valve Actuator Kits

INSTRUCTIONS: JOEY 30 CART (MK2)

DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L

Parts 3A2528C EN. Mark VII Max, Mark X Premium, and Mark X Max Electric Airless Sprayers

Transcription:

Agilent G4367A Auxiliary Electronic Pressure Control (Aux EPC) Module For the Agilent 5975T LTM-GC/MS system Installation Guide Parts Supplied Table 1 Parts supplied Description Quantity Aux EPC module 1 EPC holder 1 Bulkhead assembly 1 EPC cover ( for new design) 1 Screw M4x10 2 Screw M4x6 (for new design) 1 Retainer B (for old design) 1 Retainer (for new design) 1 Captive Screw M4x0.7x12MM (for old design) 1 Tie 3 Label (only for old design) 1 Parts Identification

Figure 1 Aux EPC module parts identification Tools Required T-10 and T-20 Torx drivers Wrench open-end, 7/16-inch and 1/2-inch (8710-0806) Installation Procedure This procedure explains how to install the auxiliary pressure control (Aux EPC) module accessory on the Agilent 5975T LTM GC/MSD. This accessory can be used to add one electronically-controlled gas streams to the GC. WARNING Refer to the Safety Manual that came with your Agilent 5975T LTM-GC/MSD for hazards that may exist when maintaining your instrument. Prepare the GC 1. Vent the instrument. (Refer to G4360-90007 Agilent 5975T LTM-GC/MSD Operational Manual for venting the MSD.) 2. Turn off the GC and unplug the power cord. 3. Remove the Analyzer Top Cover (See Figure 2) a. Open the Local Control Panel (LCP)/Analyzer window. 2 Installation Guide

b. Loosen the two captive screws on the front bottom left and top right corners of the cover, inside the LCP opening. c. Slide the cover forward until it is free of the mainframe, and lift it off the instrument. Figure 2 Removing the Analyzer Top Cover 4. Open the LTM/Guard Column Enclosure Door a. Push on the latch under the bottom left corner of the door to the LTM/guard column enclosure and open the door. 5. Remove the Small Top Cover. 6. Remove the Main Cover a. Remove 4 screws from the GC side. (See Figure 3) b. Loosen 3 screws in blue circles from MSD side. No need to remove them. c. Remove 3 screws in red circles. (See Figure 4) d. Loosen the screw on the back side. (See Figure 5) e. Remove the Main Cover. Installation Guide 3

Figure 3 Removing 4 screws from GC side Figure 4 Loosing 3 screws and remove 3 screws Figure 5 Loosing the screw on the back side 7. Remove the Fan (See Figure 6) a. Remove the two screws in the red circles from the fan b. Disconnect the fan power cable. Figure 6 Removing the fan 4 Installation Guide

8. Remove the Bulkhead Assembly (See Figure 7) a. Loosen the cap in the blue circle. b. Remove two screws in the red circles. Figure 7 Removing the Bulkhead assembly Assemble the Aux EPC 1. Install the Aux EPC holder (See Figure 8) a. Put the EPC holder at the empty location. b. Tighten two screws (M4x10) in the red circles. Figure 8 Installing the Aux EPC holder 2. Install the Aux EPC (See Figure 9) a. Connect the communication cable. b. Slide the Aux EPC module into the EPC holder. Arrange the cable to prevent it from being pinched by the Aux EPC. c. Attach the EPC module bracket by tightening the screw (M4x6). Installation Guide 5

Retainer Figure 9 Installing the Aux EPC 3. Install the Bulkhead assembly (See Figure 10) a. Tighten two screws in the red circles. b. Connect the nuts in the blue circles. Make sure the Inlet In tubing connects to the Inlet EPC and the Aux In tubing connects to the Aux EPC Channel 1. Figure 11 Installing the Bulkhead assembly 4. Attach the tubing block to the manifold (See Figure 11) a. Remove the tubing connector blank from Aux EPC Channel 1. b. Attach the tubing block to manifold and tighten two screws. 6 Installation Guide

Figure 11 Attaching the tubing block 5. Attach the tubing by the provided ties(see Figure 12) Figure 12 Attaching the tubing Restore the GC to operating condition 1. Replace all instrument covers in the reverse order in which they were removed. 2. Install the provided EPC Cover. 3. Plug in the GC and turn on the power. (Refer to G4360-90007 Agilent 5975T LTM-GC/MSD Operational Manual for turning on the GC/MSD.) 4. Connect the source gas lines to the Bulkhead assembly. 5. Turn on gas pressure and leak check all fittings. 6. On your PC, update your 5975T LTM-GC/MSD firmware to the latest version. 7. Click the provided APC Setup.exe in your CD to install Agilent 5975T LTM GC/MSD Aux EPC Setup Tool. Installation Guide 7

8. Input IP address and then click install to configure the Aux EPC. And click remove can uninstall the Aux EPC from the instrument. (See Figure 13) Figure 13 Install/remove the Aux EPC 9. Select the Aux EPC gas type on Agilent MSD Chemstation > Edit GC Parameters > Configuration > Modules. (See Figure 14) Figure 14 Selecting the Aux EPC gas type 10. Set the gas flow on Edit GC Parameters > Columns > Show All Flows > Aux EPC 1. (See Figure 15/16) 8 Installation Guide

Figure 15 Showing the Aux EPC Control Mode Figure 16 Setting the Aux EPC gas pressure Installation Guide 9

Consumables and Replacement Parts See table 2 for Aux EPC commonly-used consumable and replacement parts. Table 2 Consumable and Replacement Parts Consumable and Replacement Parts Part Number Inlet bulkhead fitting G4367-20020 Inlet bulkhead G2630-80540 AUX block weldment Assy G3430-60550 Nut Hex 2950-0203 EPC cover(small Top GC Cover) For New designed 75T G4360-00765 EPC cover (AUX EPC version) For New designed 75T G4367-00020 10 Installation Guide

Warranty The material contained in this document is provided as is, and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control. Agilent Technologies, Inc. 2001 Printed in China First edition, September 2011 安捷伦科技 ( 上海 ) 有些公司上海市浦东新区外高桥保税区英伦路 412 路联系电话 :(800)820 3278