Equipment Product Overview

Similar documents
Thermal Circuit Breaker 3120-F...

WHITE PAPER. DIRTY DOZEN: The 12 Most Common Mistakes of Specifying Circuit Protection for Equipment. E-T-A Circuit Breakers

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Selection Guide. Control Circuit and Load Protection

Thermal-Magnetic Circuit Breaker M1-..

Thermal Overcurrent Circuit Breaker 3120-F...

Bolted contact switches. Pringle switches

Thermal-Magnetic Circuit Breaker M1-...

Motion Solutions AC Induction Permanent Magnet DC Brushless DC

Thermal Overcurrent Circuit Breaker 3120-F...

ECET Distribution System Protection. Overcurrent Protection

UL Listed CCTV Power Supplies. - 4 amp. - 4 amp. - Eight (8) Fuse Protected - Eight (8) PTC Protected

Thermal Circuit Breaker / Switch Series 3131

Brochure. Synchronous generators for steam and gas turbines Proven generators reliable power

N W. Thermal Circuit Breaker / Switch Series Description. Typical applications Circuit breaker. Technical data

Where ever you go ARC Systems, Inc. is there!

Product Line Overview. The Most Logically Designed Contact Assembly

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Thermal Circuit Breaker / Switch Series 3131

Selection Guide Motor Control Device Solutions

Thermal Overcurrent Circuit Breaker 3130

Magnetic and Hydraulic-Magnetic Circuit Breaker

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

PD-Series Ground Fault Circuit Protection

- 4 amp. - 4 amp. - Sixteen (16) Fuse Protected - Sixteen (16) PTC Protected

Product guide. Enclosed NEMA starters. Answers for industry.

Magnetic and Hydraulic-Magnetic Circuit Breaker

PB-Series. GFCI/ELCI & Panel Seal

ELECTRIC ACTUATORS AND CONTROLS. Power Engineering and Manufacturing, Inc. Experts in Electrical and Mechanical Design

Product Guide. enclosed NEMA STARTERS

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

Thermal Overcurrent Circuit Breaker 3130

Transfer switch OTEC open or delayed transition

Thermal-magnetic Miniature Circuit Breaker 4230-T...

F-Series. Circuit Breaker

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation

PowerPact B. Molded case circuit breakers and switches from A

F-Series. Circuit Breaker

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

DD Frame - Series Circuit Breakers

Electronic Circuit Breaker ESS20

A real all-rounder Flexible control of both direct and alternating currents The innovative S 200 M UC

Thermal Circuit Breaker / Switch Series 3131

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

ISO 9001:2008 and AS9100C Certified. Over 4 Decades of Experience in Custom Precision Motion Control

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Thermal Overcurrent Circuit Breaker 3130

Tradition. Technology. Innovation.

Medium Voltage Drives. ABB Value Provider Program Partnership for growth and profit

Magnetic and Hydraulic-Magnetic Circuit Breaker

MINIATURE CIRCUIT BREAKER

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Heat Tracing Sales Mt. Airy, Maryland Controls

AP/UP, AP/MIL Series Magnetic Circuit Protectors

TECHNICAL WHITE PAPER

G-Series DIN-RAIL CIRCUIT BREAKER

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

din rail mounted active tracking filters with surge protection Product Guide DIN RAIL MOUNTED INDUSTRIAL DC UPS Product Guide

MAGNETIC MOTOR STARTERS

Electrical safety and reliability: Selective coordination. Protect with selective coordination

Play it safe Connectors Switches Contactors. New Energy. Special Switchgear Solutions

onlinecomponents.com

Miniature Circuit Breakers

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Circuit Breakers Circuit breakers are

DIN RAIL MOUNTED INDUSTRIAL DC UPS OPTIMIZING UPTIME.

Basics of Control Components

Ihr autorisierter Distributor: Neumüller Elektronik GmbH Motor Protectors

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

Industrial Variable Speed A-C Motors B-4511

Hydro Power Synchronous Generators. Power range MW

BAC Custom Engineered Controls

Magnetic Overcurrent Circuit Breaker

ARC Systems, Inc. is a leading supplier of AC and BLDC Motors and motion control components to the Aerospace Industry.

Enclosed Full-Voltage Starters

Systems. Intelligent. Power & Control. Würth Elektronik ICS. Solutions and technologies for:

Micropac Industries, Inc.

High Voltage Technology & Testing

NEMA & IEC Energy Saving Innovation. low voltage MOTORS

MS-Series. Circuit Breaker

Transfer switch GTEC open or delayed transition

BusBars Feed Through Terminals 114 PowerPosts 115. Terminal Blocks

Powering business worldwide

Flexible, Customizable Power Solutions for Mission Critical Success

Number 1 in efficiency

Power Electronics

1492-CB 1492-GH 1492-GS

Automatic Control Valves

Power Semiconductor Solutions EXPERTISE INNOVATION RELIABILITY

POWER YOUR TELECOM SITE WITH CAT HYBRID POWER FOR TELECOM APPLICATIONS

Ergonomic Height Adjustable Systems

ENERGY EFFICIENT FAN & MOTOR SOLUTIONS

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Transcription:

Equipment Product Overview

A History of Proven Success Integrating E-T-A s 3120 not only allowed us to save space and overall cost, but also allowed us to reduce the number of components and offer the same functionality. - Design Engineer Cozzini/Prime Edge Product Offering E-T-A s reputation is built on over six decades of experience in the design and production of circuit protection devices for equipment. When partnering with E-T-A, you have access to the broadest product range in the market today (Figure 1). Whether you require a single circuit protection device or a fully customized system solution, E-T-A s engineers will help you select the best circuit protection solution for your design. Sales Network The E-T-A sales network stretches across the United States, Mexico and Central America. As a further extension of this network, E-T-A is active in more than 60 countries - with 6 production facilities and 12 subsidiary companies. This provides customers with convenient and local access to E-T-A products and services worldwide. Market Expertise E-T-A has a full business development structure staffed with industry experts within key markets including: Transportation, Marine, Communications, Automation and Equipment. This allows customers to have application and technical conversations with someone who clearly understands the issues design engineers within each industry face daily. The breadth of product offering, expansive sales network and industry specific knowledge makes E-T-A the ideal choice when selecting a circuit protection and power management solutions provider. Thermal Heating effect of current activates a bimetal thermal actuator, offering one of the most reliable and cost effective types of circuit protection. Thermal Magnetic Latching type bi-metal is combined with a magnetic coil to provide the joint benefits of delayed operation for low current protection and fast magnetic action on higher value short circuits. Magnetic Solenoid release fast acting device with precise tripping characteristics well suited for printed circuit board applications and high current devices. Speed of operation is limited only by the mechanical inertia of the mechanism. Electronic Provides fault detection for short circuit and current overload conditions. Identifies faults on 24 VDC circuits and selectively deactivates the faulted path. Designed to be installed into switch mode power supply applications. Figure 1: E-T-A product technologies

Benefits of Multifunctional Circuit Breakers End users of electronic equipment are constantly pressuring manufacturers to develop high quality cutting-edge designs that are faster, smarter and more affordable. To remain competitive, engineers must face this challenge head-on and find partners that offer solutions to help them meet these customer demands. E-T-A offers a broad range of circuit breakers specifically designed for the equipment market. These multifunctional devices offer the following benefits: No replacement fuse required Unlike a fuse, circuit breaker switch combinations can easily and quickly be reset after tripping due to an overload. Reduced installation and wiring time Assemblers will only have to mount a single circuit breaker - eliminating the wiring between switches and fuses. Fewer Components Combine switching and overload protection in one device - reducing the footprint required for circuit protection. Streamlined material planning Purchasing departments will need to purchase 66% fewer components per load. Enhanced reliability and uptime Less individual parts reduces the possible sources of assembly errors. A Closer Look at the Equipment Industry Medical Equipment Equipment Control Professional Tools Incubators Imaging Systems Mobility Equipment Oxygenators Sterilization Machines Battery Chargers Generators Power Strips Transformers UPS Floor Care Paint Sprayer Packaging Equipment Portable Heaters Welders / Wire Feeders Commercial Food Preparation Household Appliances Lighting Beverage Dispensers Coffee Makers / Grinders Conveyor Ovens Deep Fryers Soft Serve Ice Cream Dispensers Treadmills Pressure Washer Stair Lift Garbage Disposal Systems Portable Heater 120VAC Track Lighting Electronic Scoreboards Indoor / Outdoor Signs Mobile Light Towers Theater / Stage Lighting

104 105 106 Current Rating 0.05... 10A 0.05... 10A 0.05... 10A Voltage Rating AC 250V; DC 48V AC 250V; DC 48V AC 250V; DC 48V 0.05...5 A: 1000 operations 6...8 A: 500 operations 10 A: 50 operations at 2xIN, 0.05...5 A: 1000 operations 6...8 A: 500 operations 10 A: 50 operations at 2xIN, 0.05...5 A: 1000 operations 6...8 A: 500 operations 10 A: 50 operations at 2xIN, 0.05...8 A 6 x IN (AC) 0.05...10 A 6 x IN (DC) 0.05...8 A 6 x IN (AC) 0.05...10 A 6 x IN (DC) 0.05...8 A 6 x IN (AC) 0.05...10 A 6 x IN (DC), SEV, SEV, SEV 1658 3120 3130 Current Rating 5... 30A 0.1... 20A 0.1... 20A Voltage Rating AC 240V; DC 28V 5...16 A 1,000 operations at 2 x IN, 17...25 A 1,000 operations at 2 x IN, resistive 0.1...16 A 50,000 operations at 1 x IN,, 2-pole 0.1...20 A 30,000 operations at 1 x IN,, 1-pole 30,000 operations at 1 x IN,, 1- and 3-pole 50,000 operations at 1 x IN, 2-pole 5...7 A 180 A 8...30 A 200 A 0.1...2 A 10 x IN 2.5...20 A 150 A (1-pole) 2.5...20 A 250 A (2-pole) 0.1...2 A 10 x IN 2.5...20 A 150 A (1-pole) 2.5...16 A 250 A (2-pole) 2.5...12 A 150 A (3-pole) 14...16 A 130 A (3-pole) UL, VDE, CCC - 30... +60 C (-22... +140 F) - 30... +60 C (-22... +140 F) Typical Life/ Contact Rating Interrupting Capacity (Icn) Approvals Operating Temperature Typical Life/ Contact Rating Interrupting Capacity (Icn) Approvals Operating Temperature Types of Actuators: Types of Terminals: Push-to-Reset Manual Release Toggle Quick Connect 0.250 Quick C Push-Push Push-Pull Rocker Combo.250 X 0.110 Screw

1110 1140 1410-L 1410-F 0.05... 16A 3.5... 16A 0.63... 10A 0.63... 10A AC 250V; DC 60V 0.05 10A: 10,000 ops @ 1 X IN, 00.05 10A: 6,000 ops @ 1 x IN, resistive 12...16A: 2,000 ops @ 1 x IN, resistive 3.5...8 A 200 operations, 1000 operations resistive 9...16 A 100 operations each at 2 x IN, 500 operations at 2 x IN, resistive 500 operations at 2 x IN, 30,000 operations IN 6.3 A resistive 10,000 operations IN > 6.3 A resistive 3,000 operations IN > 6.3 A 500 operations at 2 x IN AC 250 V: 0.05...10 A 8 x IN DC 50 V: 0.05...6,5 A 10 x IN 7...16 A 130 A 3.5...8 A 8 x IN 9...16 A 120 A 0.63...2 A 12 x IN 2.5...8 A 8 x IN AC, max. 50 A 10 A 6 x IN 3.15...10 A 10 x IN DC 0.63...2 A 12 x IN 2.5...8 A 8 x IN AC, max. 50 A 10 A 6 x IN 3.15...10 A 10 x IN DC UL, CSA - 20... +70 C (-4... +158 F) - 20... +70 C (-4... +158 F) X3120 2-5000 / 2-5700 2-6500 8330 0.1... 15A 0.05... 25A 0.1... 15A 0.1... 30A AC 250 V AC 250V (50/60 Hz); DC 28V AC 125/250 V (50/60 Hz); DC 80V 0.05...16 A 5,000 operations at 2 x IN, 17...25 A 5,000 operations at 2 x IN, resistive 100,000 operations at 2 x IN, resistive 10,000 operations at IN, resistive 0.1...2A 10x In 2.5...20A 150A (1 pole) 2.5...20A 250A (2 pole) 0.05...2.5 A 8 x IN 3...5 A 20 x IN 6...12 A 200 A 13...25 A 300 A 8 x IN AC 50/60 / DC 80, SEV, CCC UL -25 C...+60 C (-13...+140 F) - 10... +60 C (-10... +140 F) - 40...+85 C (-40...+185 F) Breaker: 0.1...16A 50,000 ops @1x IN, Inductive, 2 pole 0.1...20A 30,000 ops@1x IN, Inductive, 1 pole Filter: General Performance: 1A-15A, 3.04 Mil hrs High Performance : 1A-8A, 2.035 Mil hrs 10A-15A, 1.035 Mil hrs Connect 0.110 Options Key: Stud Blade Plug-in MINI type PCB Water splash protection Illumination

Make E-T-A your Design Partner Power management solutions begin with an understanding of your requirements. From concept to production, E-T-A is equipped with the expertise and tools necessary to develop and produce a solution to meet the exact specifications of your application regardless of the complexity. Design As your design partner, E-T-A adds circuit protection expertise, electromechanical design and project management capabilities to your team. This allows your design engineers to maintain their focus on customer and revenue critical applications while E-T-A designs and supplies your power management solutions. Single Source Provider E-T-A will streamline component sourcing and vendor selection to reduce material and inventory management requirements. E-T- A s efficient management and strong relationships with component vendors ensures your power management systems will be built with the best and most cost-effective materials - giving your product offering the competitive edge. Manufacturing Once the design is approved, E-T-A utilizes state of the art equipment, documented processes and skilled labor to build prototypes and manufacture high volume orders. E-T-A s fully staffed manufacturing operation eliminates the need for you to maintain and manage in-house manufacturing labor and eliminates the need for manufacturing space for power management systems. Quality & Testing Quality is E-T-A s top priority. All power management solutions are manufactured and 100% tested in E-T-A s ISO certified facility prior to shipping. You can be confident knowing the E-T-A power management system being integrated into your equipment is built and tested to the highest standards. Rev_033015 www.e-t-a.com/design E-T-A Circuit Breakers 1551 Bishop Ct. Mt. Prospect, IL 60056 Phone (847) 827-7600 Fax (847) 827-7655 usinfo@e-t-a.com