SACE FORMULA Link. Incoming kit for lugs. Outgoing for A1. Incoming for CB T6. Outgoing for A2. Doc. N. 1SDH000717R L5808

Similar documents
SACE FORMULA Link. Incoming for CB A2 X3 X3 X3 X4 X4 X4. Outgoing for A1. Incoming kit for lugs. Doc. N. 1SDH000717R L5808

Installation Instructions

Installation Instructions

International 9/8/11 WORKING PAPER Edition battery or the exposed to prevent 1.3 (5 页 ) C

在线圈中安装温度限制器 (TB) 和电机热敏电阻保护装置并且必须将两者连接在一起! 注意与维护和服务相关的说明 装配说明书是产品的组成部分, 放到触手可及的地方妥善保存 在运输马达时请采用原包装货将其固定资阿马达壳罩的钻孔上旋入环形螺栓并使用合适的举升工具

EEMB CO., LTD. Specification

EEMB CO., LTD. Specification

Configurations with jumpers (possible solutions)

产品维修手册. Maintenance Service Manual 中国 厦门蒙发利科技有限公司 蒙发利集团 客服. Xiamen Comfort Science & Technology Co.,Ltd 产品型号 /MODEL: EC-320D

Controlli: Aprire e chiudere l'interruttore alcune volte per verificare il corretto funzionamento.

RC10 Flashlight. Technical Parameters General Mode ANSI/FSC Turbo Low Mid High. 1h 55min 142h 26h 30min 6h 10min. IPX-8,underwater 2m

EAB stand-alone battery tool from F

AC Adaptor. Operating Instructions Bedienungsanleitung Manuel d utilisation Instrucciones de Funcionamiento Istruzioni per l uso 使用說明書使用说明书사용설명서

Installation and Maintenance Instructions

Packaging 22Mar11 Rev Y Specification MOD JACK ASSY, VERTICAL, COMPLIANT PIN, 8 POSN

2600W 4-Channel Intelligent Battery Charger

PT-0721 Cordless Pocket Screwdriver 7.2V

安装手册 INSTALLATION MANUAL

Lithium Battery UN38.3 Test Report

Lithium Battery UN38.3 Test Report

FC80 - <offline> "Fault and Alarm monintor"

Bul. 140G/140MG. Mounting hardware 140G-M-MH4. Installation - Installazione - Instalación. x12. x16. DIR R0004 Version G-M_ ; 140MG-M_

DJI Snail Racing Propulsion System DJI Snail 竞速多旋翼动力系统

Injection Molding Machine Servo Controller

PARTS ORDERING INSTRUCTIONS

LV REMOTE CONTROLLER INSTRUCTION MANUAL

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

SPX Product Family Smart Melt Pressure Transmitters

LT 9213A LCD FLICKER CHECKER INSTRUCTION MANUAL

CORDLESS LIGHTED SCREWDRIVER 3.6V

SeriesOne DR Series DR48E12. Rated Load Current 03: 3 Amps 06: 6 Amps 12: 12 Amps. Agency Approvals X: ATEX II 3G Ex na IIC T4 Gc approved

Robot System. Safety and Installation. Robot Controller Control Unit RC700 RC700-A Drive Unit RC700DU RC700DU-A. Programming Software EPSON RC+7.

SeriesOne DR Series. Control Voltage 280V, 3A 600V, 3A 60V, 3A 100V, 3A 4-32 VDC DR24D03. Rated Load Current 03: 3 Amps

Owner s Guide / Guide de l utilisateur / Manual de Uso / 사용자가이드 / 用户指南

List of Attachments (including a total number of pages in each attachment): 附件清单 ( 含每个附件的总页数 ): - Photos documentation (1 page) - 产品图片 (1 页 )

检测 CNAS L0095. Page 1 of 12 Pages. No. :RZUN 检验报告 TEST REPORT 产品名称 : 锂电芯 CLIENT: 委托单位 : 威凯检测技术有限公司 Vkan Certification & Testing Co., Ltd.

Robot System. Safety and Installation. Robot Controller RC90 Programming Software EPSON RC Manipulator LS series (LS3 / LS6 / LS20)

TRUCK CRANE 汽车起重机 LT 1130 DATASHEET METRIC 数据表 ( 公制 ) LT Courtesy of Crane.Market

TRUCK CRANE 汽车起重机 LT 1036/1 DATASHEET METRIC 数据表 ( 公制 ) LT 1036/1

Quick Start Guide INVENTOR SZ14-EN-A Do not remove the wrapping around the nozzle. 2. Hot! Avoid touching the heating nozzle in operation.

Insert image here. Insert image here. Insert image here. ACS800 and 600 Commision Guide and Thoubleshooting ACS800 /600 调试指导与故障分析

PHANTOM. Quick Start Manual V1.0

F-GMG01H. Operating Instructions. Nanoe Generator. Contents Parts identification. 3 Accessories 3 Safety precautions. 4 Operating requirements 10

NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA 中华人民共和国国家标准. Lubricating oils for turbines 涡轮机油

Datasheet. DIN Rail Mount

Commercialization of Car-sharing in China

Cal. Y121E STANDARD 6 3/ mm. 2.99mm. 2 years. Watch Movement Specification and Drawing. Movement Size. Casing Diameter.

Product Specification

Product Specification

Language Contents. Language PG. 1. English. 2. Chinese. 3. French. 4. German. 5. Italian. 6. Russian. 7. Spanish

Technical Information

EEMB CO., LTD. Specification

Operation Manual. Checking the Package Contents. Electronic Load Booster PLZ2004WB PLZ2004WHB. Accessories (PLZ2004WB) About the Operation Manual

FPRCL - 90V - 25 M S - 24/2

Introduction of NS2 Manual Motor Starter

JINLONG MACHINERY & ELECTRONICS

icolor Accent MX Powercore gen2

exhibitor manual will help you effectively finish your participation in the exhibition, please read it

T6A OPERATOR S MANUAL FLASHLIGHT

3.7V Rated Capacity 2600mAh. Maximum Continuous Charge Current Maximum Discharge. 2600mAh

EA5506. Electrically Actuated Carbon Steel PN16 Ball Valve. Description

产品规格书. 锂聚合物电池 / Lithium Polymer Batteries. PL V-2200mAh 1S1P

Company Profile / 公司简介

Preface. First edition (March 2009) Second edition (August 2010) Third edition (April 2011) PFU LIMITED Preface 1

Bar Code Scanner. Quick Start Guide QS Rev A 3/12

Power Magic Ultra Battery B-124

更多的机会来源于合作和创新 帝斯曼复合材料树脂集团严政华

E-bikes in China: Status, Challenges & Future

Installation Instructions for the Electronic SURETOUCH* Foam Soap System

IMPORTANT! For secure mounting, follow instructions thoroughly.

Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento.

aximum recommended conductor support distance 7.87"/00 mm 7.87"/00 mm - Use cable or insulated busbars/ or perform specific type test on the installat

POWERHOUSE. POWERHOUSE POWER PRODUCTS PH2700PRi SHOP MANUAL. Coast Distribution November, 2010

Installation and Maintenance Instructions

UL/FM BUTTERFLY VALVES

GDR GDS GDX Professional

AIAA Freejet Test of the AFRL HySET Scramjet Engine Model at Mach 6.5 and 4.5

Installation Instructions for the Electronic SURETOUCH* Foam Soap System

参展邀请 上海国际汽车制造技术与装备及材料展览会. Exhibitor Invitation SINCE The leading Exhibition for Automotive Manufacturing in China 上海新国际博览中心 E1-E7 馆

CLAMP KIT FOR FULL GLASS DOORS

IMPORTANT! BEFORE UNPACKING AND ASSEMBLING THE ANTENNA MANUAL FULLY INSTRUCTIONS READ THIS INSTALLATION Rev: H

Installation Instructions for the Electronic SURETOUCH* Foam Soap System

LED VaporProof Fixture

Items Symbols Conditions Maximum ratings Units Collector-Emitter voltage VCES 1700 V Gate-Emitter voltage VGES ±20 V Continuous

Premium Complete Rework Station with Electric Pump

HIPULSE U UPS Single Module And 1+N (Expandable) 160/200/300/400kVA User Manual

SafeRing / SafePlus. SF6 insulated ring main unit and compact switchgear Installation and operating instructions

公司简介. 生产设备 Production Facilities 产品用途. Applications - A1 - 迁入新厂 新增四台 CNC 研磨 研发 造消隙 速机

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

MOONRING 1.5 MOONRING 3

INSTRUCTION MANUAL INFORMATION MANUALS SERVICE ~ 1 ~ Those instructions are for your safety. Read carefully before use, and keep them.

Installation Instructions CRAFT M/L

INSTALLATION INSTRUCTION Magnetic Transformer

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

LED VAPOR PROOF FIXTURE

Stainless Steel in Exhaust Systems Angel L. Ramirez

Conductive Polymer Solid Aluminum Capacitor Foundation of Teapo Electronic Capacitor Company stock listed in OTC market in Taiwan

Positioner for Pneumatic Actuators

NL-FTPR150, FUNCTIONAL TRAINER ASSEMBLY INSTRUCTIONS

Transcription:

Phase indent Circuit No Cable Size FORMULA Link FORMULA Link is approved for use with the following ABB SACE Circuit Breakers: - SACE Tmax T6 - SACE FORMULA A - SACE FORMULA A - SACE FORMULA A In selecting circuit breakers both for initial installation and for replacement, due consideration must be given to the short circuit capacity, instantanous trip current, voltage and current requirements of the application. Doc. N. SDH77R64 - L588 SACE FORMULA Link Istruzioni di installazione FORMULA Link 6-8 Installation instructions for FORMULA Link 6-8 Installationsanleitungen FORMULA Link 6-8 Instructions d'installation FORMULA Link 6-8 Instrucciones de instalación FORMULA Link 连接母排安装说明书 FORMULA Link 6-8 Disconnettere ogni alimentazione a monte dell'installazione e portare ogni interruttore in posizione di aperto prima di installare, modificare o eseguire manutenzioni. E' proibito avvicinarsi a parti in tensione prima di aver disconnesso l'alimentazione a monte. ABB non si assume responsabilità per danni a persone o cose derivanti dalla non applicazione o dall'incorretta applicazione delle istruzioni fornite qui e nelle istruzioni d installazione degli interruttori. Disconnect all power sources on the supply side of the installation and set each circuit-breaker to the open (off) position before proceeding with the installation, modification or servicing operations. Do not touch live parts without having first disconnected the power sources on the supply side. ABB declines all liability for damage to persons or things deriving from failure to comply with the instructions given here and in the installation instruction manuals of the circuit-breakers, or from incorrect application of such instructions. Jede der Anlage vorgeschaltete Stromversorgung unterbrechen und jeden Leistungsschalter in die Aus-Stellung bringen, bevor Installationen, Änderungen oder Wartungsarbeiten ausgeführt werden. Es ist verboten, sich Spannung führenden Teilen anzunähern, bevor die Stromversorgung stromauf unterbrochen worden ist. ABB haftet nicht für Sach- oder Personenschäden infolge der Nichtanwendung oder der nicht korrekten Anwendung der Anweisungen, die hier und in den Installationsanleitungen der Leistungsschalter geliefert werden. Débrancher chaque alimentation en amont de l installation et placer chaque disjoncteur dans la position de ouvert avant de mettre en place, modifier ou effectuer des opérations d entretien. Il est interdit de s approcher des parties sous tension avant d avoir débranché l alimentation en amont. ABB décline toute responsabilité pour les dommages aux personnes ou aux biens dérivant de la non application ou de la mauvaise application des instructions fournies ici et dans les instructions de mise en place des disjoncteurs. Desconectar todas las alimentaciones en entrada a la instalación y poner todos los interruptores en posición de abierto antes de efectuar instalaciones, modificaciones o trabajos de mantenimiento. Está prohibido acercarse a partes bajo tensión antes de haber desconectado la alimentación en entrada. ABB no se asume ninguna responsabilidad por eventuales daños a las personas o a las cosas imputables al incumplimiento o bien a una errónea implementación de las instrucciones aquí suministradas y aquellas relativas a la instalación de los interruptores. 在进行安装 更改或维修操作前, 必须断开所有供电端的电源, 并将每个断路器操作到断开 (off) 位置 在没有断开供电端 电源之前, 不可触摸带电的零部件 ABB 不承担因不遵守本说明书和断路器安装说明书或不正确的使用而导致对人身或物体造成损伤的责任 Panel Reference...[Type] Incoming Supply: Current...[A] Voltage...[V] Frequency...[Hz] Incoming device...[type] FORMULA Link 6-8A IEC 649- Useful Length F=54 Ue=55V AC, 5-6 Hz Ui=69V AC, 5-6 Hz Uimp=6 KV Icw=4 KA, rms sec Outgoing for A Incoming kit for lugs Outgoing devices: Load 6 6 6 6 6 Incoming for CB T6 4 4 4 6 6 6 Outgoing for A 8 6 6 6 6 6

A B 9 7 5 5 5 A 88.5 5 5 76. A C D OK,Nm NO E F Nm

G Example with main CB T6 H 57 ±.5 7Nm Nm I 用户自备. 6A J 8A mm Nm 4 9Nm 5 mm 9Nm K 用户自备. 8A L 8A mm Nm 4 9Nm 5 mm 9Nm

M Example without main CB N 用户自备 54 ±.5 4 77.4 77.4 4 4 Nm 4 min 4 94 7 max ø max 9 max 6 max O Example mounting outgoing P Q R for A only Nm OK NO 用户自备

S for A only for A only T 4Nm 用户自备.,Nm U for A only V for A-A 65 mm 8Nm,Nm 6 mm W 用户自备. FORMULA Link 6-8A IEC 649- Useful Length F=54 Ue=55V AC, 5-6 Hz Ui=69V AC, 5-6 Hz Uimp=6 KV Icw=4 KA, rms sec FORMULA Link 6-8A IEC 649- Useful Length F=54 Ue=55V AC, 5-6 Hz Ui=69V AC, 5-6 Hz Uimp=6 KV Icw=4 KA, rms sec NL 6 ITH AW R FO 6 FORMULA Link FORMULA Link is approved for use with the following ABB SACE Circuit Breakers: O A ND A A ITH A A W OR 8 F R 6 S FO LWA A 8 FORMULA Link - SACE Tmax T6 - SACE FORMULA A - SACE FORMULA A - SACE FORMULA A FORMULA Link is approved for use with the following ABB SACE Circuit Breakers: - SACE Tmax T6 - SACE FORMULA A - SACE FORMULA A - SACE FORMULA A In selecting circuit breakers both for initial installation and for replacement, due consideration must be given to the short circuit capacity, instantanous trip current, voltage and current requirements of the application. Panel Reference...[Type] In selecting circuit breakers both for initial installation and for replacement, due consideration must be given to the short circuit capacity, instantanous trip current, voltage and current requirements of the application. Panel Reference...[Type] Incoming Supply: Current...[A] Voltage...[V] Frequency...[Hz] Incoming device...[type] Incoming Supply: Current...[A] Voltage...[V] Frequency...[Hz] Incoming device...[type] Outgoing devices: Outgoing devices: Phase indent Circuit No Load Cable Size Phase indent Circuit No Load Cable Size 用户自备.

57 7.5 57 7.5 7 57 7 57 9 45 45 9 6A-8A A B F 4WA 54 79 F 6WA.5 55.5 F 8WA 7.5.5 F4 WA 84 49 F5 WA 46 486 48 C Z 4 47 69 47 4.5 8.5 7 6A-8A D F 4WA 5 F 6WA 6.5 F 8WA F4 WA 8 F5 WA 456.5 D 4 min. 54 7 6.5 6.5 54.5 7 B 5 A 5 == == 6A 8A ( 47 ) With A only With A and A, or A only 6A C 6 mm 8 mm 8A C 8 mm 8 mm C With A only With A and A, or A only 6A C 6 mm 8 mm 8A C 8 mm 8 mm Copyright 9 ABB.All rights reserved www.abb.com