Start-up Instructions

Similar documents
Specifications of MAXON VALUPAK burners for 50 Hz operation

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

Specifications of STICKTITE and PILOTPAK Nozzles

Specifications of STICKTITE and PILOTPAK Nozzles

2.0 Burner Operating Parameters and Requirements

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

Pilot Capacities/Specifications

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

G76x Direct Spark Ignition Controls

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Design and Application Details

Design and Application Details

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

Eclipse RatioAir Burners

VALUPAK. Packaged gas burners

G72x Series Direct Spark Ignition Controls

Low emissions, high performance natural gas burners

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

Capacities and Operating Data

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP

Design and Application Details

KINEMAX. Medium velocity gas or oil burners

First Correlating Revision No. 1-NFPA [ Section No ]

North American 4485 Tempest SE

VALUPAK. Packaged gas burners

MULTIFIRE. High temperature dual fuel burner

G600 Series Replacement Intermittent Pilot Ignition Controls

Table of Contents GF801U Series

M SERIES TECHNICAL DATA INFORMATION PACKET

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

GEMINI GAS CONTROL PRODUCT INFORMATION

E Series CE Approved Intermittent Pilot Ignition Control

CHALLENGER Propane to Natural Gas Instructions

Surefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual

Design and Application Details

LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM

G821L/G822L Series Integrated Function Direct Spark Ignition Controls

SureFire II TM Pilot Forced Draught. Gas pilot type SP-32-xx-FD. Instruction Manual 1. INTRODUCTION 2. OPERATION PRINCIPLE AND TECHNICAL SPECIFICATION

Performance Selection Data

Q35 Series Automatic Vent Damper System

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

The Combustex Pilot Pro 500 Ignition System with Pilot Tip and Flame Sensor

Direct Gas-Fired Heating

Heating and Gas Installations - December 2014

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction

36H Gas Control Product Information

LVDT/HC PILOT BURNER. External raw gas pilot burner

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Operation of the FFBH is enabled and disabled by the Automatic Temperature Control Module (ATCM).

Specifications of LVDT/HC-pilot burner. Materials of construction. Duct burners - LVDT/HC-pilot burner. combustion systems for industry

TECHNICAL INSTRUCTIONS

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

SureFire II TM Natural Draught Gas Pilot type SP-48-NG/PG-ND Instruction Manual

MASTER DIRECT OIL HEATERS. MODEL 35 CED 10 kw Model ILLUSTRATED PARTS BREAKDOWN. Motor and Pump Assembly

V5197A Firing Rate Gas Valve

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

SERVICE MANUAL RRG SERIES HEAVY DUTY GAS GRIDDLE - NOTICE - ML ML ML RRG Shown

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

TriOx Triple Air Staged Ultra Low NOx Burner

UPFLOW/ HORIZONTAL GAS FURNACE

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

Linea 28 Mark 1. Serial Number up to VOKERA SPARE PARTS BREAKDOWN

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

7. SERVICING AND COMPONENT ADJUSTMENTS

XL/LNXL SERIES. Installation, Operation, and Service Manual for Vertical Configuration

1470 SERIES HOT AIR GAS BURNER

B21 Series BASOTROL Gas Valve

Low BTU Copper Brute TM II Series Models: BWCV0200 BWCV0300 BWCV0400

S1 SERIES TECHNICAL DATA INFORMATION PACKET

INSTALLATION INSTRUCTIONS

D SERIES TECHNICAL DATA INFORMATION PACKET

INSTALLATION INSTRUCTIONS

D SERIES TECHNICAL DATA INFORMATION PACKET

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Power Flame Incorporated

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

The Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor

BLOWER VACUUM SWITCH FAILED OPEN

N-084M and N-069M-DV Series Heat Exchanger Replacement

BG1600M Intermittent Pilot Ignition Control

3 Edition Product brochure GB AGA

PREMIX TUNNEL BURNERS

INSTALLATION INSTRUCTIONS

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

Controls and Accessories Part Number Controls and Accessories Part Number

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

G861 Series Integrated Function. Direct Spark Ignition Control

INSTALLATION INSTRUCTIONS

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

Applies to: Models F, B, FE, and BE with spark pilot

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

Transcription:

RadMax Burners Page 400-S- Start-up Instructions Read complete instructions before proceeding and familiarize yourself with all the system s equipment and components. Verify that all equipment has been installed in accordance with the original manufacturer s current instructions. CAUTION: Initial adjustment and light-off should be undertaken only by trained and experienced personnel familiar with combustion systems, with control/flame safeguard circuitry and with knowledge of the overall installation. Equipment installation and operating procedures should comply with all applicable international, federal, state, local codes and standards. Initial RadMax Burner start-up:. Close all burner fuel valves and gas cocks. Make preliminary adjustment to fuel gas regulator(s) to establish adequate fuel pressure.. Check all electric circuitry. Verify that all control devices, flame safeguard, and interlocks are operable and functioning within their respective settings/ranges.. Check that all duct and chambers are clear and that their dampers operate freely. Adjust all dampers to their proper start-up positions. Open the manual pet-cock valves on all burner Direct- Spark/Flame-Sensing Ports. 4. Start process fan(s) and combustion blower(s) and purge the entire unit in accordance with the appropriate codes and standards. Adjust combustion air pressure to establish the proper burner manifold pressure per the Capacities and Specifications table on page 400-S-. A test connection is provided on the burner manifold for set-up adjustment purposes. Required manifold pressures are differential pressures relative to the firing chamber. For on/off (single firing rate) operation, adjust air to establish the proper manifold differential pressure required for the desired firing rate. For variable firing rate operation, refer to the following procedure: A. Set low fire combustion air flow. Position combustion air flow control device to establish burner manifold pressure required for the desired minimum firing rate (per table on Page 400-S-). Manifold differential pressure should never be less than.0 w.c. B. Set high fire combustion air flow. Position combustion air flow control device to establish burner manifold pressure required for the desired maximum firing rate (per the table on Page 400-S-.) Manifold differential pressure should not exceed 6.0 w.c. C. Return air flow control device to minimum. 6. Adjust fuel/air mixing device to the recommended initial settings. Refer to the appropriate start-up instructions provided by the manufacturer for this equipment. Ignite the burner. (Direct spark applications only; refer to appropriate manufacturers instructions for piloted systems.) A. Verify combustion air blower is running. B. Set air flow control device to minimum. C. Open main gas shut-off valve(s). D. Initiate trial for ignition sequence and verify spark ignitor is arcing properly. E. If burner does not ignite, close main gas shutoff valve(s) and re-purge unit before attempting to ignite the burner again. 8. Adjust burner minimum firing rate. Allow burners to come up to stable operating temperature. With the air flow control device at minimum, adjust the fuel flow to establish the desire operating temperature within the range stated in the Capacities and Specifications table on Page 400-S-. If a slight blue haze is present on the face of the burner, this is an indication that the mixture is too lean. To correct, increase fuel flow until the blue haze is no longer present. If you notice a yellow blanket of flame on the burner surface, this is an indication the mixture is too rich. To correct, decrease fuel flow until the yellow haze is no longer present.. Adjust burner maximum firing rate. Slowly increase combustion air flow and fuel flow in small increments as allowed by the fuel/air ratio controller. Hold at each step and allow the burner to come up to a stable operating temperature. Make adjustments to fuel flow as necessary to establish the desired operating temperature within the range stated in the Capacities and Specifications table. Continue to increase the fuel/air ratio controller in small increments and make adjustments at each step until the desired high firing rate is established. 0. Verify settings. After establishing high and low fire settings, cycle the burner from high to low fire several times to confirm the repeatability of fuel/air settings. Shut down the burner and re-ignite to confirm reliability of ignition system and light-off settings. Check all safety interlocks and limits and confirm proper settings and operation.. Verify temperatures. Confirm desired face temperature is achieved. Also, confirm oven/chamber temperature does not exceed 00 F. Verify that sufficient process circulation exists to prevent localized hot spots in excess of 00 F on burner bodies. /0

Page 400-S- RadMax Burners Capacities and Specifications RadMax Type //0 Burner Head Start-up Instructions M anifold Pressure " w.c. 4 4. ( nominal) 6 Minimum Capacity Flow at Minimum Face Temperature Range 0 08 6 7 Btu/hr 7,800 0,700,00 4, 6,00 8,00 8 0. 7. 4. 6. 8. Btu/hr 0,800 4,00 6,600 8,000,00,700 0. 8 4. 6. 6 8. 0.. 7 F 00-48 0-7 0-6 0-0 7-6 00-6 Direct Spark/Flame Sensor Port M anifold Pressure " w.c. 4 4. ( nominal) 6 66 77 87 7 06 Btu/hr,40 6,0 7,00 7,478 7,860 8,0 6. 8. 6 RadMax Type //0 Burner Head (metric data) Manifold Pressure Minimum Capacity Flow at Minimum Face Temperature Range mbar 0 0. 0. ( nominal). 4 4. 80 8. 8.7. 0. kw 6. 6. 7 8. 4 0.0 0. 0.67 0.7 0.74 0.8 kw. 4. 4. 7 6. 4 0. 0.40 0.47 0. 0. 0.6 C 66-806 -86 60-84 6-866 64-877 64-04 Direct Spark/Flame Sensor Port Manifold Pressure mbar 0 0. 0. ( nominal). 4 4..88.8.48.6.76.00 kw. 6. 8.... 0. 0.8 0.0 0. 0. 0.4 NOTE: Most systems are designed to nominal capacities. Reduced or extended capacities are possible. RadMax should not be installed in ovens/chambers above 00 F. Contact Maxon for more information. Tile Temperature (F) Face Temperature Range for Various Firing Rates 700 600 "w.c. Manifold Pressure 00 "w.c. Manifold Pressure 400 4"w.c. Manifold Pressure 00 4."w.c. Manifold Pressure 00 "w.c. Manifold Pressure 00 6"w.c. Manifold Pressure 000 0 4 6 8 0 4 6 8 0 Flow - Natural Gas ()

RadMax Burners Page 400-S- Assembly Instructions Upon receipt of your Maxon RadMax Burner, it may be necessary to install the burner heads to the burner manifold. The burner heads are shipped completely assembled and only require two fasteners per head to attach them to the burner manifold. Following the illustrations below, mount the burner head to the manifold:. Place the gasket on the air/gas inlet on the underside of the burner head. This gasket is used to help provide a gas tight seal and must be installed.. Place the head on the manifold such that the plug mates up with the hole in the manifold.. Use two M8 screws and two M8 washers (provided) to attach the bottom clamp against the manifold and securely fasten the head. Alternate the tightening of the bolts to ensure an even clamping force. 4. Repeat for the remainder of the burner heads. Make sure the face or tile sides of the heads are relatively flush with each other before final tightening of the fasteners to - foot-lbs. Gasket Detail of Gasket Installation Gasket Direct Spark/Flame Sensing Port Burner Head Direct Spark/Flame Sensing Port Connection (4 Places) Rivet Manifold Assembly Bottom Clamp M8 Washer M8 Lock M8 Screw /4" NPT Control Valve /8" Corrugated Stainless Steel Tubing with /4" NPT Male Connectors /0

Page 400-S-4 RadMax Burners Maintenance Instructions Installing Replacement Burner Tiles Step Coat the tile support face of the body casting with a thin film of gasket adhesive. Figure Step Install the burner body gasket. Be careful to ensure gasket is installed squarely and use care to avoid tearing gasket material. Allow gasket to set for -0 minutes before installing tiles. Figure Step Place tile retainer frame face down on a flat surface. Install burner tiles into tile retainer, making sure that no gaps exist between tiles and that tiles are properly centered in tile retainer. Figure

RadMax Burners Page 400-S- Maintenance Instructions Step 4 Place burner body casting face down into tile retainer frame, with burner body gasket resting on top of burner tiles (along inside edge of tile retainer frame). Figure 4 Step Install spring clips to secure the tile retainer frame. Figure /0

Page 400-S-6 RadMax Burners Notes