S&C Vista Underground Distribution Switchgear

Similar documents
Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

Instructions for Installation and Operation

Cleaning Flooded Gear

Cleaning Flooded Gear

Installation and Operation

Instructions for Installation and Operation

S&C Source-Transfer Vista Underground Distribution Switchgear

Instructions for Installation

Installation, Operation, and Maintenance

PAD-MOUNTED SWITCHGEAR INSPECTION & MAINTENANCE RECOMMENDATIONS TYPE PSI/II. 15kV 25kV. Qualified Persons

Installation and Operation

Installation. S&C Omni-Rupter Switches Outdoor Distribution 14.4 kv and 25 kv

Operation. S&C Vista Underground Distribution Switchgear UnderCover, Vault-Mounted, and Pad-Mounted Styles. Table of Contents

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Operation. S&C Source-Transfer Vista Underground Distribution Switchgear. Pad-Mounted, Dry-Vault-Mounted, Wet-Vault-Mounted, and UnderCover Styles

Instructions for Installation

Inspection and Maintenance

Installation And Operation

OPERATOR S MANUAL SINGLE PORT UNIVERSAL CAR CHARGER

Installation. Loadbuster The S&C Loadbreak Tool Outdoor Distribution (14.4 kv through 34.5 kv) Table of Contents. Instruction Sheet

Installation. S&C Omni-Rupter Switches Outdoor Distribution 14.4 kv and 25 kv

S&C Circuit-Switchers Mark VI Installed on S&C Mounting Pedestals 84- through 102-inch Phase Spacing Outdoor Transmission (69 kv through 138 kv)

Installation and Operation

Installation and Operation

Installation. S&C Circuit-Switchers Mark VI 69-kV 51-inch Phase Spacing Single Pedestal Design Outdoor Transmission.

S&C M Series Switch Operators Reciprocating and Rotating Switch Operation

Introduction CAUTION CAUTION. S&C Power Operated Metal-Enclosed Switchgear Indoor and Outdoor Distribution (4.16 through 34.5 kv)

Introduction CAUTION. S&C Power Operated Metal-Enclosed Switchgear Outdoor Distribution (4.16 kv, through 34.5 kv)

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

WARNING. TYPE PSI/II PAD-MOUNT SWITCHGEAR with Non-Loadbreak Fuse Mountings 15kV 25kV INSTRUCTIONS. Qualified Persons. For Installation and Operation

SBCNNS. Abrasive Blast Cabinet Assembly & Operating Instructions

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

EJ212 Electric Jack 1 Ton (2,000 lbs) Assembly & Operating Instructions

AVOIDING ELECTROCUTION HAZARDS

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

IB PowlVac ITE-HK Remote Racking Device

i n s t r u c t i o n m a n u a l

rechargeable umbrella light

S&C Switch Operators Types AS-1A and AS-10

FACT SHEET Standard: Electrical Safety

User s Manual. Automatic Switch-Mode Battery Charger

TESTER ISOLATION MODULE LIGHT SYSTEM. Operating Instructions. CAUTION Read this document before testing any snowplows.

Instruction manual. Type 3AH35-MA vacuum circuit breaker magnetic-actuator operator module.

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

SAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4

Challenger 60 & 70 Tow Series. Installation & User Manual

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

3 Phase Smart Controller

ARC Welder Assembly & Operating Instructions

Figure 1. Kearney Type HX cutout.

Abrasive Blast Cabinet Assembly & Operating Instructions

IMPORTANT SAFEGUARDS

3 TON JACK STANDS. Operator s Instruction Manual. Rated Capacity 6,000-lb MODEL# T43002T

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

Safety, Installation And Operating Instructions For The Following Battery Charger Models: i2412, i3612, i4809, i2425, i3625, and i4818

BlinkerBeam SL80 Controller User Guide

HI-POT/CONTINUITY TESTER Model PLEP01

Freedom egen System End-of- Line Functional Checklist

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Manufacturing & Service: Bierer & Associates Inc. Patent No. 6,885,180. ST Series Service Tester Phase Identifier Operating Instructions ST500PGN

Operation Guide. Hydraulic Leveling Systems #2000, #2010, #3000, and # Table of Content. Introduction

Operator s Manual. Automatic Electric Jack Leveling. The leveling system shall only be operated under the following conditions:

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

ATTACH YOUR RECEIPT HERE ITEM # FT. PRE-LIT DOUGLAS FIR TREE. MODEL #DF-75C85 Español p. 8

Installation, Operation and Maintenance Instructions. SLS Series Single Phase Disconnector

Operation Guide. Operation Guide. Winnebago Hydraulic Leveling Systems by Kwikee. Introduction. Table of Content WARNINGS

ES750 Battery-powered Cable Cutter

Energized Electrical Work

WELDING HELMET INSTRUCTIONS. Part #20520

COOPER POWER SERIES. VFI tester operating instructions. Underground Distribution Switchgear MN285001EN

82V LITHIUM-ION BATTERY CHARGER GC 400

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Gentex by VOXX Corporation Installation Instructions

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

ibusway for Data Center

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

POWER INVERTER 700 WATT / 1800 WATT PEAK

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Installation Instructions

"ELECTRICAL SAFETY IN THE LABORATORY"

Operator Manual. Transfer Switch. RSS100 and RSS Cummins Inc. All rights reserved. English

ResQ 48 & 60. Installation & User Manual

Effective November 2016 Supersedes September 1998 (S )

R T SERIES ROTARY TILLER

Electrical Equipment and Terminology

SB20G. Large Pressurized Abrasive Blaster Assembly & Operating Instructions

Altivar 61/71 Adjustable Speed Drives Plastic Kits and Power Terminal Kit

W & A 12 ROW TOP LEVELING STACKER LEVEL BANDER

LABORATORY SAFETY SERIES: Electrical Safety

Galaxy Receiving and Unpacking 09/

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

WheelieSafe. WheelieSafe. User Manual. Motorized Trolley. Distributor:

Specifications. S&C Switch Operators Types AS-1A and AS-10a. Conditions of Sale

Installation Instructions

Road Service Quick Reference Guide 2016 Lincoln MKZ / MKZ Hybrid. Quality and Education Services AAA Automotive 1000 AAA Drive Heathrow, FL 32746

DISCHARGER-ANALYZER BDX USER'S MANUAL

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Emergency De-Icer (HSTAT-R Series) Instruction Manual

Transcription:

S&C Vista Underground Distribution Switchgear Pad-Mounted, Vault-Mounted, and UnderCover Styles Instructions For Installation and Operation of Portable Motor Operator TABLE OF CONTENTS Section Page Section Page INTRODUCTION Qualified Persons.............................. 2 Read this Instruction Sheet...................... 2 Retain this Instruction Sheet..................... 2 Proper Application............................. 2 Warranty...................................... 2 SAFETY INFORMATION Understanding Safety-Alert Messages............. 3 Following Safety Instructions.................... 3 Replacement Instructions and Labels............. 3 Location of Safety Labels........................ 4 COMPONENTS General....................................... 5 INSTALLATION Installing the Portable Motor Operator................6 OPERATION Opening, Closing, or Grounding.................. 11 REMOVAL Removing the Portable Motor Operator...............13 TROUBLESHOOTING If the Remote Control Ready Light Does Not Light.... 14 Fault Conditions on the S&C-Furnished Ac-Input Power Supply........................................... 14 S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection Instruction Sheet 681-525 December 10, 2001 2001 Supersedes Instruction Sheet 681-525 dated 1-15-01

INTRODUCTION Qualified Persons Ç WARNING The equipment covered by this publication must be installed, operated, and maintained by qualified persons who are knowledgeable in the installation, operation, and maintenance of underground electric power distribution equipment along with the associated hazards. A qualified person is one who is trained and competent in: The skills and techniques necessary to distinguish exposed live parts from non-live parts of electrical equipment. The skills and techniques necessary to determine the proper approach distances corresponding to the voltages to which the qualified person will be exposed. The proper use of the special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools for working on or near exposed energized parts of electrical equipment. These instructions are intended only for such qualified persons. They are not intended to be a substitute for adequate training and experience in safety procedures for this type of equipment. Read this Instruction Sheet Retain this Instruction Sheet Read this instruction sheet thoroughly and carefully before installing or operating your S&C Portable Motor Operator. Familiarize yourself with SAFETY INFORMATION on pages 3 and 4. This instruction sheet is a permanent part of your S&C Portable Motor Operator. Designate a location where you can easily retrieve and refer to this publication. Proper Application Ç CAUTION The equipment in this publication must be used with S&C Vista Underground Distribution Switchgear only. It has been designed to operate when powered within a specified voltage range. The voltage ratings for the S&C Portable Motor Operator are located on the ratings label on the operator. Warranty The standard warranty contained in S&C s standard conditions of sale, as set forth in Price Sheet 150, is applicable to the S&C Portable Motor Operator covered in this instruction sheet. 681-525 2

SAFETY INFORMATION Understanding Safety-Alert Messages There are several types of safety-alert messages which may appear throughout this instruction sheet as well as on labels attached to the S&C Portable Motor Operator. Familiarize yourself with these types of messages and the importance of the various signal words, as explained below. Ç DANGER DANGER identifies the most serious and immediate hazards which will likely result in serious personal injury or death if instructions, including recommended precautions, are not followed. Ç WARNING WARNING identifies hazards or unsafe practices which can result in serious personal injury or death if instructions, including recommended precautions, are not followed. Ç CAUTION CAUTION identifies hazards or unsafe practices which can result in minor personal injury or product or property damage if instructions, including recommended precautions, are not followed. identifies important procedures or requirements that, if not followed, can result in product or property damage if instructions are not followed. Following Safety Instructions If you do not understand any portion of this instruction sheet and need assistance, contact your nearest S&C Sales Office or S&C Authorized Distributor, or call S&C Headquarters at (773) 338-1000, Monday through Friday between 8:30 AM and 5:00 PM Central Standard Time. (In Canada, call S&C Electric Canada Ltd. at (416) 249-9171, Monday through Friday between 8:00 AM and 5:00 PM Eastern Standard Time.) Read this instruction sheet thoroughly and carefully before installing your S&C Portable Motor Operator. Replacement Instructions and Labels If you need additional copies of this instruction sheet, contact your nearest S&C Sales Office, S&C Authorized Distributor, S&C Headquarters, or S&C Electric Canada Ltd. It is important that any missing, damaged, or faded labels on the equipment be replaced immediately. Replacement labels are available by contacting your nearest S&C Sales Office, S&C Authorized Distributor, S&C Headquarters, or S&C Electric Canada Ltd. 3 681-525

SAFETY INFORMATION Location of Safety Labels B A Reorder Information for Safety Labels Location Safety-Alert Message Description Number A Ç CAUTION Never Drill Into Housing G-10043 B Ç CAUTION Not Designed for Permanent Installation G-10047 681-525 4

COMPONENTS General The S&C Portable Motor Operator has been carefully designed to allow users to power operate, from a remote location, load-interrupter switches and single-pole or three-pole fault interrupters in Vista Underground Distribution Switchgear. The S&C Portable Motor Operator is a light-weight operator that can quickly and easily be attached without tools to UnderCover, Vault-Mounted, and Pad-Mounted Styles of Vista Underground Distribution Switchgear. The S&C Portable Motor Operator is not intended for permanent installation. The portable motor operator includes a carrying case and 50-foot cable with remote controls, and utilizes power supplied by one of the following: User-furnished 24-volt battery and battery charger, or S&C-furnished 24-volt battery and battery charger, or S&C-furnished ac-input power supply. S&C Portable Motor Operator Carrying case Remote control User-furnished 24-volt battery and battery charger S&C-furnished 24-volt battery and battery charger S&C-furnished ac-input power supply 5 681-525

INSTALLATION Installing the Portable Motor Operator Step 1 Observe the position of the operating disk and selector lever on the load-interrupter switch way or single-pole or three-pole fault-interrupter way to which the portable motor operator is to be installed. Remove padlocks. See Figure 1. If operation is to be from the closed position to the open position or vice versa, place the selector lever in the grounded position as shown in Figure 1. In the far-right position, the selector lever allows operation between the closed and open positions; inadvertent operation directly from the closed position to the grounded position is prevented. If operation is to be from the open position to the grounded position or vice versa, place the selector lever in the blade-closed position. See Figure 2. In the far-left position, the selector lever allows operation between the open and grounded positions; inadvertent operation directly from the grounded position to the closed position is prevented. Operating disk (in blade-closed position) Selector lever (in blade-grounded position) Figure 1. Observe position of operating disk and selector lever. Ç WARNING ALWAYS make sure that the cables connected to the load-interrupter switch or fault interrupter are de-energized before grounding the switchgear. Failure to follow this precaution can result in a flashover and equipment damage. Before operating to the ground position, always make sure that the cables connected to the load-interrupter switch or fault interrupter are de-energized. Check for voltage using the potential indicator (option suffix -L1 or -L2 ), if furnished, as instructed under Checking for Voltage Using Optional Voltage Indication section in Instruction Sheet 681-510, 682-510, or 683-510. Operating disk (in blade-open position) Figure 2. Selector lever in blade-closed position. Selector lever (in blade-closed position) 681-525 6

INSTALLATION Step 2 Adjust the position lever of the portable motor operator to correspond with the position of the operating disk observed in Step 1. See Figure 3. Position lever (in blade-closed position) Figure 3. Adjusting position lever of portable motor operator. Step 3 While holding the latching lever in the open position, lift the portable motor operator and place on the operating shaft of the gear. See Figure 4. The position lever of the portable motor operator may need to be manually rotated slightly from side to side to allow the output shaft to line up with the operating shaft on the gear. Operating shaft Position lever Latching lever Figure 4. Positioning portable motor operator on operating shaft. 7 681-525

INSTALLATION Step 4 When the portable motor operator is seated on the operating shaft of the gear, release the latching lever. Make sure that the portable motor operator is fully seated and that both latches have latched onto the stop ring on the tank. See Figure 5. Stop ring Latch Latching lever Figure 5. Checking that portable motor operator is fully seated and latched. Step 5 Connect the cable with remote controls to the portable motor operator. See Figure 6. Cable with remote controls Figure 6. Connecting cable with remote controls. 681-525 8

INSTALLATION Step 6 Connect the control power cable to the portable motor operator and to the control power source. See Figures 7 through 9. Control power source (user-furnished 24-volt battery shown) Figure 7. Connecting control power cable. Control power cable Control power source (S&C-furnished 24-volt battery shown) Control power cable Figure 8. Connecting control power cable. Control power source (S&C-furnished ac-input power source shown) Control power cable Figure 9. Connecting control power cable. 9 681-525

INSTALLATION Step 7 If the power source is an S&C-furnished ac-input power supply, insert its three-prong plug into a grounded 120-volt ac power receptacle. Be sure to check that the LEDs labeled DC 24V and LOAD 2L+ are lit on the power supply as shown in Figure 10. If they are not lit, refer to Figure 17 and the instructions in the Troubleshooting section on page 14. Power supply LEDs Figure 10. LEDs on the S&C-furnished ac-input power supply. Step 8 Check that the READY LIGHT is lit on the remote control. See Figure 11. It will remain continuously lit while control voltage is supplied to the operator. If the READY LIGHT is not lit, or is blinking rapidly, refer to the Troubleshooting section on page 14. Ready Light Figure 11. Remote control. 681-525 10

OPERATION Opening, Closing, or Grounding Ç WARNING Do not operate this switchgear if the SF 6 - gas pressure gauge is in the red zone. Failure to follow this precaution can result in a flashover and equipment damage. Step 9 Make sure that the SF 6 -gas pressure gauge is in the green zone (or the green and yellow striped zone) by lifting the viewing window cover under Way 1. See Figure 12. If the SF 6 -gas pressure gauge is in the green and yellow striped zone, the switchgear can be operated but the tank must be repaired (if necessary) and refilled with SF 6 gas as soon as possible. Figure 12. SF 6 -gas pressure gauge. Step 10 Open the viewing window cover and confirm the position of the load-interrupter switch or single-pole or three-pole fault-interrupter disconnect by visually observing the position of the blades. See Figures 13 and 14. Figure 13. Window cover lifts for viewing of switch or fault-interrupter disconnect blade position. Figure 14. Confirm blade position. 11 681-525

OPERATION Step 11 Ç WARNING ALWAYS make sure that the cables connected to the load-interrupter switch or fault interrupter are de-energized before grounding the switchgear. Failure to follow this precaution can result in a flashover and equipment damage. To operate the portable motor operator, press and hold the ENABLE BUTTON on the remote control, then press the appropriate CLOSE, OPEN, or GROUND button. See Figure 15. The READY LIGHT on the remote control will blink while the portable operator is changing the state of the load-interrupter switch or fault interrupter. The READY LIGHT will stop blinking and light continuously only when the switching operation is complete. Enable Button If you have operated a load-interrupter switch or single-pole or three-pole fault interrupter from the closed position to the open position, and now wish to operate to the grounded position, you will need to remove the portable motor operator and reposition the selector lever. If operation is to be to the grounded position, make sure that the cables connected to the load-interrupter switch or single-pole or three-pole fault interrupter are de-energized. Check for voltage using the potential indicator (option suffix -L1 or -L2 ), if furnished, as instructed under Checking for Voltage Using Optional Voltage Indication section in Instruction Sheet 681-510, 682-510, or 683-510. If you have operated a load-interrupter switch or single-pole or three-pole fault interrupter from the grounded position to the open position, and now wish to operate to the closed position, you will need to remove the portable motor operator and reposition the selector lever. Refer to Steps 1 through 4 for instructions on positioning the selector lever and installing the portable motor operator. Figure 15. Remote control. 681-525 12

REMOVAL Step 12 Open the viewing window cover again and confirm the position of the load-interrupter switch or single-pole or three-pole fault-interrupter disconnect by visually observing the position of the blades. See Figures 13 and 14. Removing the Portable Motor Operator Step 13 To remove the portable motor operator, hold the latching lever in the open position and lift the portable motor operator up, off the operating shaft of the gear. See Figure 16. The portable motor operator is not intended for permanent installation. Latching lever Connector Caps Figure 16. Removing portable motor operator from gear. Step 14 Before storing the portable motor operator in its carrying case, be sure to replace the caps that protect the power and remote control connectors. The caps are shown in place in Figure 16. Step 15 Replace padlocks removed previously in Step 1. 13 681-525

TROUBLESHOOTING If the Remote Control Ready Light Does Not Light Step 16 Check that the control cable is properly connected to both the portable motor operator and the remote control. Step 17 Ensure that the power cable is properly connected at both the portable motor operator and the power supply ends. Step 18 If using an S&C-furnished ac-input power supply, check that the indicator lights are lit as detailed in Step 7. If not, verify that the ac-input power supply is connected to a properly grounded 120-volt power source. If the Ready Light blinks rapidly after the Close, Open, or Ground buttons are pressed, return the unit to S&C for repair. Fault Conditions on the S&C-Furnished Ac-Input Power Supply The operating state of the ac-input power supply is indicated by LEDs on the front of the power supply, as shown in Figure 17. Step 19 The S&C-furnished ac-input power supply is equipped with a retentive shutdown feature. If a short circuit develops across the 24-volt dc output, the unit will shut itself down for at least 5 minutes. Should this occur, disconnect the power supply from the 120-volt ac source. LED LABELLED DC 24V LOAD 2L+ TEMP> LED ON 24 Vdc across output terminals Motor operator circuit supplied with 24 Vdc Not applicable LED FLASHES Overload Shutdown due to overheating LED OFF No output voltage short-circuit at output no source voltage present Unit temperature less than maximum allowable Figure 17. LED display on the S&C-furnished ac-input power supply. Step 20 Wait at least 5 minutes, then reconnect the power supply to the 120-volt ac source. Step 21 Verify that the appropriate LEDs are lit on the front cover of the power supply, then continue with switching operations. 681-525 14