XT SERIES Jockey Pump Controllers Features

Similar documents
DIESEL Engine Fire Pump Controllers Features

PATTERSON PUMP COMPANY

February, O & M Manual for EATON FDJ Series Jockey Pump Controllers. Instruction Booklet. For more information visit:

SECTION MOTOR CONTROL

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

Product Guide. enclosed NEMA STARTERS

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

XT IEC Power Control Manual Motor Protectors

Product guide. Enclosed NEMA starters. Answers for industry.

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

WARREN COUNTY, N.Y. M/E REFERENCE

Enclosures. See Section Typical Description

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

B BASIC HEAT TREATMENT CONSOLE

825-P Modular Protection System for motors Specification Guide

Technical Information

and Refrigeration Institute). CNX Special Purpose Contactors

3. Coils shall be of molded construction

AUE-AUD-AU2E AU2D-AUED

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

FIREPAK-E21 & FIREPAK-ED21

Medium Voltage Metal-Enclosed Switches

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION MOTOR CONTROLLERS

SECTION MOTORS & MOTOR CONTROLLERS

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

,QGXVWULDO#*HQVHW. 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28.

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

NIBCO Press System Bronze Ball Valves Two-Piece Body Full Port Bronze Trim Blowout-Proof Stem

Application Description

CI-TI Contactors and motor starters Types CI 61 - CI 98

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

BAC Custom Engineered Controls

FIRE PUMPS F AI LISTED R LISTED N K S MOR S E P U IT Y S Y S T E M CE R T IF IE D

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Reduced Voltage Motor Starters

SD Series Non-Fused Load Switches

Contactors & Starters Index

Enclosed Full-Voltage Starters

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC.

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Bussmann series Quik-Spec Power Module Switch elevator disconnect

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

WELLS RURAL ELECTRIC COMPANY Adopted: March 1976 Revised: March 21, 2017 Reviewed: August 21, 1998 RULE NO. 2

Non-Spring Return EconoDrive Floating Actuator

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

33GS, 40GS, 55GS, 60GS, 75GS & 80GS GPM, 1 10 HP, 60 HZ, SUBMERSIBLE PUMPS

SDS Enclosed Star-Delta Starter User Guide

Open Chassis Star-Delta Starter User Guide

JOCKEY PUMP CONTROLLERS

Design Standard. Purpose: Design Standard:

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Multi-Pak Group Control

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

[V] Common Control Transformer Control (See page 1-78 Note)

1 Phase electronic contactor (SC 1)

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

SECTION MOTOR CONTROLLERS

Medium Voltage Metal-Enclosed Switches

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

ADS7 AC Contactor Starters

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

Catalog Number 1NO-1NC 5 XTPAXSA11 5 XTPAXSAC

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Basics of Control Components

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

Motors Automation Energy Transmission & Distribution Coatings EDP11. Enclosed Drive Panel USA EDP11

Standby kw Prime kw

US Catalog. Motor protection and control AF Range contactors & overload relays

CI-TI Contactors and Motor Starters Type CI 6-50

Selection Guide Motor Control Device Solutions

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

AF series contactors (9 2650)

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Duplex Commercial Pressurizer -DCP

Contactor Types CI 61-98

PD-Series Ground Fault Circuit Protection

SECTION MOTOR REQUIREMENTS for HVAC

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

For many applications

PRODUCT INFORMATION PACKET

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

Transcription:

XT SERIES Jockey Pump Controllers Features XT Series Jockey Pump Controllers March 2012 1-1 XT Power Controls The XT Series of Jockey Pump Controllers incorporate Eaton s XT Power Controls which are designed for the global marketplace. The XT controls carry global ratings, are small in size and are available in a wide variety of operating voltages. They are easy to install and maintain, due to their modular, plug-in design. 120V Control Power Transformer Digital Display Eaton's XTJP and XTJY series of jockey pump controllers are supplied standard with an 1/8 DIN, NEMA 4X digital panel meter that displays current pressure and hi and low setpoints on a 4-digit, superbright LED display. Pressure input is provided by a 4-20mA pressure sensor. NEMA 2 Enclosures Product Description ACROSS THE LINE JOCKEY PUMP CONTROLLERS The XTJP jockey pump controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single motor starter. Starting inrush current is approximately 600% of rated full load amperes. All jockey pump controllers are wired with a 120V control power transformer as standard. Technical Data Enclosures have an oven baked powder paint finish and are supplied with NEMA 2 rating, unless otherwise ordered. Available options include: NEMA 3R, 4, 4X, 12. ACROSS-THE-LINE (Direct On Line) JOCKEY PUMP CONTROLLERS Line Voltage 200-208V Motor Horsepower 1/3-15Hp 220-240V 380-415V 440-480V 5-600V 120V 1 ph 240V 1 ph 1/3-40Hp 1/3 - Hp 1/3 - Hp 1/3 - Hp 1/3-5Hp 1/3-10Hp WYE-DELTA (Star-Delta) JOCKEY PUMP CONTROLLERS When six or twelve-lead delta connected jockey pump motors are started wye (star) connected, approximately 58% of line voltage is applied to each winding. The motor develops 33% of full-voltage starting torque and draws 33% of normal locked-rotor current from the line. After an adjustable time delay (during which the motor accelerates), it is reconnected for normal operation. Product Features WYE-DELTA (Star-Delta) JOCKEY PUMP CONTROLLERS Line Voltage 200-208V 220-240V 380-415V 440-480V 5-600V Motor Horsepower 1/3-15Hp 1/3-40Hp 1/3 - Hp 1/3 - Hp 1/3 - Hp (0.74-11.03KW) (0.74-29.42KW) (0.74-36.78KW) (0.74-36.78KW) (0.74-36.78KW) Combination Motor Controllers All jockey pump controllers are supplied with EATON combination motor controllers, which combine the circuit breaker and overload in one device. Standards & Certification The XT Series of Jockey Pump Controllers meet or exceed the requirements of Underwriters Laboratories, Underwriters Laboratories Canada, the Canadian Standards Association and the New York City Building Code. Sealed Rotary Handle Mechanism The rotary handle mechanism can be padlocked in the OFF position. BR058077K

Dimensions XTJP Jockey Pump Controllers May 2012 Dimensions Standard Enclosure - Type NEMA 2 - Jockey Pump Controller 10.75 [273] 16.13 [410] 8.00 [203] Ø 0.27 [Ø7] x4 WALL MTG. HOLES 2 1 13.00 [330] 4 3 16.35 [415] NOTES: 1 - ISOLATION SWITCH 2 - HAND/OFF/AUTO SWITCH 3 - DOOR LATCH 4 - DIGITAL DISPLAY Dimensions in inches and [millimeters] 8.08 [205] PIPING ENTRANCE 1/4" NPT - FEMALE 2.13 [54] 4.03 [102] 8.59 [2] Dimensions in inches and [millimeters]. 200-208V 220-240V 380-415V 440-480V 5-600V Motor Hp 0.33-3 4 5-10 65 120V 1 240V 1 Motor Hp Motor Hp 0.33-0.5 65 0.33-2 65 0.75 1-2 Motor Hp Motor Hp Motor Hp Motor Hp 0.33-3 65 0.33-5 65 0.33-7.5 65 4 7.5-10 5-10 3-5 Approx. Weight Lbs (Kg) 22 (10) 10 15-20 0.33-10 NOTES: 1. All enclosures finished in Red. 2. Cable Entrance either top or bottom. 3. Standard Enclosure type NEMA 2. Pending MD05805161K/B

Dimensions XTJP Jockey Pump Controllers May 2012 Dimensions Standard Enclosure - Type NEMA 2 - Jockey Pump Controller with Options 21.76 [553] 16.38 [416] 13.00 [330] Ø 0.27 [Ø7] x4 WALL MTG. HOLES 2 1 16.00 [406] 4 3 21.15 [537] NOTES: 1 - ISOLATION SWITCH 2 - HAND/OFF/AUTO SWITCH 3 - DOOR LATCH 4 - DIGITAL DISPLAY Dimensions in inches and [millimeters] 8.08 [205] PIPING ENTRANCE 1/4" NPT - FEMALE 2.63 [67] 3.96 [101] 8.60 [2] Dimensions in inches and [millimeters]. 200-208V 220-240V 380-415V 440-480V 5-600V Motor Hp 0.33-3 4 5-10 120V 1 240V 1 Motor Hp Motor Hp 0.33-0.5 65 0.33-2 65 0.75 1-2 65 Motor Hp Motor Hp Motor Hp Motor Hp 0.33-3 65 0.33-5 65 0.33-7.5 65 4 7.5-10 5-10 3-5 Approx. Weight Lbs (Kg) 22 (10) 10 15-20 0.33-10 NOTES: 1. All enclosures finished in Red. 2. Cable Entrance either top or bottom. 3. Standard Enclosure type NEMA 2. Pending MD05805166K/B

Electrical Wiring Schematic XTJP Jockey Pump Controllers - Single Phase May 2012 Electrical Wiring Schematic - 120Volt - Single Phase ES05805178K/B

Electrical Wiring Schematic XTJP Jockey Pump Controllers - Single Phase May 2012 Electrical Wiring Schematic - 240Volt - Single Phase ES05805179K/B

Electrical Wiring Schematic XTJP Jockey Pump Controllers - Single Phase March 2012 Electrical Wiring - Options ES0580K

Part Number / Options Selection Guide XTJP / XTJY Jockey Pump Controllers March 2014 Part Number / Options Selection Guide XTJP / XTJY Jockey Pump Controllers XTJP XTJY Horsepower (KW) Options 1/3 (0.25) C1 Extra Contacts "Pump Run" 1/2 (0.373) C2 Extra Contacts "AC Power Failure" 3/4 (0.56) E1 NEMA 3R - Raintight Enclosure 1 (0.75) E2 NEMA 4 - Watertight Enclosure 1.5 (1.1) E3 NEMA 12 - Industrial Dust Tight Enclosure 2 (1.5) E5 NEMA 4X - 304 Stainless Steel Enclosure 3 (2.25) E8 Tropicalization 4 (2.94) E9 NEMA 4X - Painted Steel 5 (3.75) E10 NEMA 4X - 316 Stainless Steel Enclosure 7.5 (5.6) EX Export Crating 10 (7.5) POL "Power-On" Light 15 (11) PRL "Pump Run" Light 20 (15) P7 Low Suction Pressure Switch and Alarm Pilot Light 25 (.6) P8 Low Suction Shutdown (Requires P7) 30 (22) P10 Pressure Transducer - Sea Water Rated 40 (30) R1 Space Heater (120 / 220V) (37) R2 Space Heater c/w Thermostat R3 Space Heater c/w Humidistat Voltage S Sequential Start A = 208V - 60HZ T Running Period Timer B = 240V - 60HZ Z Elapsed Run Time Meter C = 380V - HZ D = 480V - 60HZ E = 600V - 60HZ Languages L1 = English F = 415V - HZ L2 = French H = 380V - 60HZ L4 = Italian J = 400V - HZ L5 = Spanish K = 400V - 60HZ L6 = Portuguese G1 = 120V Single Phase (XTJP only) L7 = Chinese G2 = 240V Single Phase (XTJP only) L8 = Polish L9 = Dutch L11 = Turkish PA058027K/B

Fire Pump Controllers 1-1 Features XTJP / XTJY Jockey Pump Controllers Typical Jockey Pump Controller Specifications Approvals The Jockey Pump Controller shall meet the requirements of UL 8 [Underwriters Laboratories (UL)] and approved by [Canadian Standards Association (CSA)] [New York Department of Buildings (NYSB). Starting Type The controller shall be Across-the-Line or Wye-Delta (Star Delta) type designed for full voltage starting. Ratings The Controller shall have a minimum withstand rating of,000 symmetrical amperes @ [208V] [240V] [380V] [415V] [480V] [600V] [120V Single Phase] [240V Single Phase]. The horsepower rating of the controller shall not exceed Hp for three (3) phase units or 10Hp on single phase units. Construction The controller shall include a combination Circuit Breaker / Overload Motor Protector. The circuit breaker shall be mechanically interlocked such that the enclosure door cannot be opened when the handle is in the on position except by a tool operated defeater mechanism. The controller manufacturer shall manufacture the contactor, circuit breaker, pushbuttons, and enclosures. Brand-labeled components will not be accepted. Supply Voltage The jockey pump controller shall be available with the following supply voltages: A B C D E F G1 G2 200-208V 60 Hz 220-240V 60 Hz 380V / 60 Hz 440-480V 60 Hz 5-600V 60 Hz 415V / 60 Hz 120V Single Phase 240V Single Phase Enclosure The controller shall be housed in a NEMA Type 2 (IEC IP11) drip-proof, powder baked finish, freestanding enclosure. Languages The controller shall be available in a variety of languages including, but not limited to: English, French, Spanish, Turkish. Digital Indication The controller shall be supplied with a digital display that shall indicate the following: System Pressure, Start Pressure, Stop Pressure. The digital display shall be supplied with a solid-state 4-20mA pressure sensor. The pressure Start and Stop points shall be adjustable in increments of one (1) PSI. The digital display shall be a door-mount type that permits exterior programming with the controller door secured. Options The jockey pump controller shall have provision to be supplied with the following options: C1 Extra Contacts Pump Run C2 Extra Contacts AC Power Failure E1 NEMA 3R Raintight Enclosure E2 NEMA 4 Watertight Enclosure E3 NEMA 12 Industrial Dust Tight Enclosure E5 NEMA 4X Stainless Steel Enclosure E8 Tropicalization E9 NEMA 4X - Painted Steel E10 NEMA 4X - 316 Stainless Steel Enclosure EX Export Crating POL Power On Light PRL Pump Run Light P7 Low Suction Pressure Switch and Alarm Pilot Light P8 Low Suction Shutdown (Requires P7) P10 Pressure Switch (0-0psi) Sea Water R1 Space Heater (120 / 220V) R2 Space Heater c/w Thermostat R3 Space Heater c/w Humidistat S Sequential Start T Run Period Timer Z Elapsed Run Time Meter Manufacturer The controller shall be of the XTJP Across-the-Line or XTJY Wye Delta (Star-Delta) type as manufactured by EATON Corporation. Optional Enclosures 1. NEMA 3R (IEC IP14) rain-tight enclosure. 2. NEMA 4 (IEC IP66) watertight enclosure. 3. NEMA 4X (IEC IP66) watertight 304 stainless steel enclosure. 4. NEMA 4X (IEC IP66) watertight 316 stainless steel enclosure. 5. NEMA 4X (IEC IP66) watertight corrosion resistant enclosure. 6. NEMA 12 (IEC IP52) dust-tight enclosure. Run Period Timer An optional Run Period Timer shall be available. March 2012 PS058010K