DYNACOMP. The top-class reactive power compensator

Similar documents
Dynacomp The Top-Class Dynamic Response Compensator

LV Capacitor Bank APC

LV Capacitor CLMD Reliability for Power Factor Correction

LV Capacitor Bank APC

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

APC03 capacitor bank series The ABB comprehensive solution for automatic power factor correction

CLMD Low-voltage capacitors for reliable power factor correction

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

PhiCap Capacitors for Power Factor Correction

EMPAC Metal enclosed capacitor bank for wind applications

Power factor correction Static switching units (Three phase).

LV Capacitor CLMD03 Power Module Instruction manual

R.4. Automatic capacitor banks with static system. Power factor correction and harmonic filtering. Homepage :

LOW VOLTAGE CAPACITORS AND CAPACITOR BANKS. Capacitors department

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system

Power System Solutions (PSS)

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

Index Low Voltage Network Quality. Low Voltage Network Quality

Sharda Electronics & Co. An ISO 9001:2015 Certified Company

Low Voltage Products. Low Voltage Capacitors Power Factor Correction Solutions

smartvar Dynamic VAR Compensator

Three Phase Capacitors KNK

MODVAR Low voltage reactive power compensation modules Installation manual

CP Automatic capacitor bank

Dynamic PFC:Thyristor Modules TSM Series

LV Capacitors QCap-L series Capacitors for power factor correction

Power factor correction Harmonic filtering Dynamic flicker compensation

Power Factor Correction

CLASS 5870 ReactiVar Power Factor Capacitors AT6000/AT7000 Transient Free Reactive Compensation

High Reliable Components for Power Factor Correction and Power Quality

&MFDUSJGJDBUJPO Products 1PXFS 2VBMJUZ 'JMUFST 12'* o 12'. o 12'4 )BSNPOJDT NJUJHBUJPO MPBE CBMBODJOH BOE SFBDUJWF DPNQFOTBUJPO PO -7 OFUXPSLT

Automatic COSYS PFC. Automatic power factor correction system NEW

POWER CAPACITORS. Cylindrical capacitor standard duty

NEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter:

CTU 02. Thyristor switching module for fast PF compensation. User manual

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

ABB n.v Power Quality in LV installations

Let's conserve energy for nation's progress. An ISO 9001: Co. IS: Manufacturers of :CAPACITOR GRADE METALLISED

Power Factor Correction Capacitors Type LKT

Power Factor Correction Equipment

Power Factor Correction

High Reliable Components for Power Factor Correction and Power Quality

- Soft resin impregnated Stacked winding Tripple Safety System

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

A Group brand. REACTIVE ENERgY COMPENSATION AND POWER QUALITY MONITORINg. CATALOgUE

Film Capacitors Power Factor Correction

ABB November 16, 2016 Slide 1

1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN

Film Capacitors Power Factor Correction

ELG4125: Flexible AC Transmission Systems (FACTS)

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

Sr. No. Details Page No. 1 MV Capacitor Unit Drawings 3. 2 Technical Perticular for Capacitor Unit 4. 3 MV Surge Capacitor Unit Drawings 6

PRODUCT CATALOGUE 2016

Q pole Pole Mounted Capacitor System

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

multicond Power capacitors Data sheet: multicond

Transforming Energy.. For Advanced Technology

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Product Group Brochure. PS Range Capacitor Vacuum Switches

AC Capacitors Safety and Application Manual

Power factor correction and harmonic filtering. Power capacitors Low Voltage

PQC-STATCON. PPHVC-Power Quality Solutions. Instantaneous and stepless power quality compensation for dynamic reactive power and unbalanced loads

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

Power Factor Correction Capacitors in sheet steel cases

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

HV Compensation & Filtering Products

Caps unlocked. ABB s new QCap cylindrical capacitor improves power factors

Power Protection Discrete Automation & Motion South Africa

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS

AGroup brand POWER FACTOR CORRECTION AND CONTROL OF ELECTRICAL NETWORK QUALITY INTERNATIONAL VERSION

C1000 Series Automatic Cap Bank

Power Factor Correction - UPS - Stabilizers - AC / DC Power Supply Units

Power IT LV Active Filters PQFI - PQFM PQFK - PQFS

Easy Choice for Energy Efficiency

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Power Factor Correction Capacitors Harmonic Filter Reactors

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Power Factor Correction Capacitors Type LKT

Technical Specification For Outdoor Substation Harmonic Filter Banks

AF series contactors (9 2650)

Study of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank

Power capacitors Low Voltage

TECHNOLOGICALLY ADVANCED ENERGY PRODUCTS. Product Preview & Price List 2018

Capacitor Related Definitions

FINHRM FINHRM5 FINHRMA FINHRMAC

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

NXPLUS C Single busbar. Maintenance-free for lifetime

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Microcontroller Based Power Factor Correction Using SCR

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

Est DCM Double Conversion Module 400kVA - 800kVA

MU MMMREV.2 09/01 UNI EN ISO ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

Visual comparison of Plain & Hazy PP Film

SINAMICS SM150. Siemens product performance features. Competitor product profile. Components. Power, transport units. Service friendliness

AIR CORE REACTORS. Phoenix Electric Corporation

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Transcription:

DYNACOMP The top-class reactive power compensator

Dynacomp vs Electromechanical switching of capacitors Electromechanical switching of capacitors The Dynacomp : the top-class dynamic compensator Transients at switching Conventional banks with contactors are switched on when reactive power is needed, but the precise instant of switching is variable and not controlled. This has the consequence that the switching of the capacitors results in a big transient. This transient disturbs the electrical network, is dangerous for the contactors and increases the stress on the capacitors. The disturbance created in the voltage waveform could perturb sensitive equipment. This is shown on the figure below, where 86 kvar are switched on by contactors. The current reaches 3640 A peak, approximately twelve times the nominal 304 A peak. Transient free switching The Dynacomp, fitted with electronic switches instead of contactors, is the perfect choice in applications where transient-free switching is required. It will not cause disturbances to sensitive networks or neighbouring equipment. The figure below shows the switching of the same step but with the static switch of the Dynacomp. The current reaches only 304 A peak, i.e. the nominal value. Current waveform when switching a conventional bank with contactors (transient) Current waveform when switching a Dynacomp Slow response time Electromechanically switched power factor correction systems are fitted with discharge resistors. This allows reducing the voltage difference between the capacitors and the network and consequently the magnitude of the transients. Discharging the capacitors takes several seconds and tremendously limits the response time of such system, without suppressing the transients. Fast response time The powerful control of the Dynacomp and its switching concept allows dynamic response times less than two network periods for power factor correction, less than one network period for voltage drop compensation and virtually instantaneous if an external signal is available. Limited life Contactors have limited lifetimes and need to be replaced frequently. Such systems also require important maintenance efforts. Long life The transient free switching (with no electric arc, no moving parts) combined with the self healing capacitors used in the Dynacomp guarantees a very long life of the system without any limitation in the number of switching operations. 2

Dynacomp : principle The Dynacomp is basically a circuit consisting of capacitors and reactors switched on the network by solid state power electronics, without any moving part. A three-phase Dynacomp circuit is represented here. Single phase Dynacomps can also be provided. The Dynacomp can compensate low voltage equipment for nominal voltages up to 690V. Three phase Dynacomp circuit The thyristors are fired at the natural zero crossing of the capacitive current. As a result, capacitors are connected to the network without transients. The control is such that only complete alternations of the current are allowed. This ensures that no harmonics are generated by the Dynacomp. Dynacomp : advantages Transient free switching Fast switching ( 1 cycle) Harmonics absorption Combination of ABB Capacitors and ABB Reactive Power Control Technology Network measurements (including harmonics) ABB semiconductor rating and field experience ABB micro-processor based RVT-D Dynacomp Controller ISO 9001 certification ISO 14001 certification 3

Dynacomp : description Dynaswitches RVT-D controller Capacitors (CLMD type) The Dynacomp consists of capacitors, reactors, Dynaswitches and the electronic control. Those components are mounted in cubicle together with auxiliary apparatus and wiring to form a factory assembled and tested system. The Dynacomp is a tailor-made system and cubicle dimensions as well as the arrangement of components are adapted to each particular situation. Systems assembled in several cubicles are usually mounted on a common base frame. Reactors RVT-D controller Micro-processor based, the RVT-D is designed to meet the specific needs of the customer : For accurate and fast power factor compensation. For minimum response time allowing an important reduction of voltage drops and flicker effects. The RVT-D has features including: full graphics display network information: voltage, current, THDV, THDI, harmonics spectrum, Dynacomp current, powers and more. programmable protection thresholds (undervoltage, overvoltage, overtemperature, excessive harmonic distortion and power outage) a help button giving instant access to a description of all RVT-D s features and functionality a printer connection 4

Dynaswitches The Dynaswitch is the electronic switch of the Dynacomp controlling the connection of the capacitors to the network. The Dynaswitch is composed of two AC thyristor valves, consisting of back-to-back connected pairs of high power thyristors (high voltage disc type), governing the passage of current. As only full alternations of current are allowed, the Dynaswitch does not act as a classical AC thyristor valve for which the firing pulses of the thyristors are chosen to modulate the current. It plays the role of a classical mechanical interrupter, with the possibility to choose explicitly the closing instant. The interest is to avoid transients. The opening instant occurs at zero crossing of the current, as thyristors are used. Structure of one Dynaswitch The Dynaswitch is also equipped with its own cooling device, ensuring a normal working temperature for the semiconductors. The complete system is protected by very high speed fuses. ABB Reactors The capacitors may be series connected to reactors but this is not required by the Dynacomp itself. It may be required by the application if harmonics are present on the network. In that case, the reactor offers major advantages to the system, such as the protection of the capacitors against high frequency currents and filtering properties. Reactors are iron cored with copper or aluminium windings and copper terminals. Units are completely impregnated under vacuum and overpressure in a polyester resin and dried in furnace. The reactors are designed for heavy industrial environments. 5

CLMD Capacitors The ABB CLMD capacitor consists of a number of wound elements made with a dielectric of metallized polypropylene film. It offers the following advantages: Dry type design The CLMD has a dry type dielectric and therefore cannot give any risk of leakage or pollution to the environment. In-house metallized film The dry dielectric of the CLMD is made of ABB in-house metallized polypropylene film giving: - High voltage withstand capability - Excellent peak current handling capacity - High capacitance stability - Long life even under high electrical stress - Very low losses - Exceptional self-healing properties Unique sequential protection system A unique sequential protection system ensures that each individual element can be disconnected from the circuit at the end of its life. High level of safety Capacitor elements are encapsulated in a thermo-setting resine and placed in a sheet steel box filled with inorganic, inert and fire proof granules (vermiculite) that will absorb the energy produced or extinguish any flames in case of a possible defect at the end of an element's life. Thermal equalizers are fitted to surround each capacitor element and provide effective heat dissipation. Heavy duty enclosure Capacitor element: - dry dielectric - self-healing - very low losses Thermal equalizer Wire connection Metal end spray In-house metallised polypropylene film (unique profile) Secondary foil winding Biaxially oriented polypropylene dielectric Thermo-setting encapsulation Plastic case Fuse link Vermiculite Dynacomp : applications Motor start The high reactive power demand during a motor start creates undesired voltage drop on low voltage side as well as on high voltage side. In the figures below, 5 steps of 250 kvar are switched on for the compensation of a 375 kva motor of a high pressure refrigeration compressor. The voltage drop on the high voltage side was creating problem in the neighbouring companies. The Dynacomp solution allowed to fulfill the voltage drop limit on the high voltage side imposed by the utility company. Without Dynacomp With Dynacomp

Harbour crane Contactor switched banks always produce transients when switched. Switching of charged capacitor results in large transients when the capacitor and network voltages are in phase opposition at the closing instant. This is why conventional banks always have delays (~1 minute) between switching on/off the capacitors. This delay permits the discharge of the capacitors through the discharge resistors, but limits the utilisation of conventional capacitor banks for rapidly fluctuating loads requiring frequent switchings. During its cycle, the crane requires variable amounts of reactive power. The whole crane cycle lasts about one minute. Obviously, compensation with conventional banks is not possible for that operation: the cycle is too short and the required reactive power is too large. The amount of reactive power supplied by the Dynacomp and the missing kvar appears also on the graph. The Dynacomp provides the reactive power in discrete steps. The step size is 225 kvar with a 1:2:2 switching sequence. As the switching of the Dynacomp does not require the discharge of the capacitors, the utilisation of the Dynacomp for the compensation of any load with rapid variations is possible. The figure below represents an example of a Dynacomp installed on a crane in a harbour. The working cycle of the crane is shown as the required reactive power versus time. Harbour crane applications Welding machine On the figures below, 4 steps of 150 kvar are switched on for the compensation of a 210 kva single phase welder with the use of an external signal for instantaneous response time (voltage drop compensation). In addition to this positive effect, the quality of the welding was changed is such a way that a reduction of the welding parameters has been possible, lowering the power consumption for the same production, that too with a better quality of the final product. These figures show clearly that the voltage drop due to the welding machine is totally reduced. Perturbation to sensitive devices like PLC, computers, lighting,... are avoided. Without Dynacomp With Dynacomp 7

Technical specifications Rated voltage From 220 to 690V - 50Hz or 60Hz, three or single-phase. Output rating Up to 500 kvar per step. The Dynacomp is a totally tailor-made product adapted to each particular need. Capacitors Dry type self healing. Design according to IEC 831 1&2. Controller Type RVT-D Micro-processor based system. Operating temperature: -20 C to 70 C. Current input: 5A or 1A (RMS) (class 1 CT). Network and Dynacomp measurements. Standard cubicle Steel sheet. Color: RAL 7035. Protection: IP23. According to EN60439. Ambient temperature According to IEC831 (-10 C/+40 C). Measuring system Micro-processor based system for balanced three-phase networks or single-phase networks. Connection diagram for three-phase systems This connection is valid for open-loop, closed-loop and external trigger control systems. Measuremements provided by the controller are network measurements in any case. Single-phase systems are also available. Please consult us. External trigger system is made through one or two inputs (opto1 and opto2: 15-24Vdc). www.abb.com/lowvoltage While all care has been taken to ensure that the information contained in this publication is correct, no responsibility can be accepted for any inaccuracy. We reserve the right to alter or modify the information contained herein at any time in the light of technical or other developments. Technical specifications are valid under normal operating conditions only. We do not accept any responsibility for any misuse of the product and cannot be held liable for indirect or consequential damages. 2GCS303017A0060