CIRCUIT PROTECTION. BEP provides the circuit protection your vessel needs.

Similar documents
Circuit Breaker Types

Circuit Breaker Types

Circuit Breaker Types

Pro Installer Series. Modular Connectivity Saves Space, Easy to Install

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

Circuit Breakers/Protection, Fuses/Fuse Products

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Control Circuit Protection

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

ID ID. Series 19. Mechanical Products Company

National Marine Manufacturers Association Product Compliance Specialist Examination D.C. Electrical (2013 MY) ABYC E-11 (08 Amended 09)

1Fast, dependable delivery

F-Series. Circuit Breaker

Selection Guide. Control Circuit and Load Protection

F-Series. Circuit Breaker

BusBars Feed Through Terminals 114 PowerPosts 115. Terminal Blocks

Products :: Circuit Protection :: Thermal Circuit Breakers

Timer Relays - Fixed & Adjustable

Thermal-magnetic Miniature Circuit Breaker 4230-T...

PD-Series Ground Fault Circuit Protection

GMA GDB/GDA MDL MDA. Fuses SMALL DIMENSION. Item Number Amps Price. Item Number Amps Price. Item Number Amps Price. Item Number Amps Price

LOW PROFILE MINI FUSES AFTERMARKET MINI BLADE FUSES MINI BLADE FUSES. 34 AUTO MARINE PRODUCT CATALOGUE 2018/19 VISIT:

Miniature Circuit Breakers

Circuit protection technology for automotive, home, marine and RVs.

smissline Description

AP/UP, AP/MIL Series Magnetic Circuit Protectors

SECTION PANELBOARDS

Manual Motor Starters. Meta-MEC

Vehicle Electrical Center (VEC) Series

209 Series. Magnetic Circuit Protectors

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

Item Number Amps Input Banks Price BI $ BI $95.30 BI $ BI $ BI $203.

Consumer Aftermarket New Product Catalog Automotive Circuit Protection Products and Accessories

Timer Relays - Fixed & Adjustable

PB-Series. GFCI/ELCI & Panel Seal

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

QUALITY ASSURANCE & DOCUMENTATION

Miniature circuit breaker Application guide

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Selection Guide Motor Control Device Solutions

Series L9 UL489 Miniature Circuit Breakers

ELECTRICAL PANELS. Chap.

Self-protected Combination Starters System PKZ 2-SP

R.C.B.O. SP / 1 module

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

Technical Information

Electronic Circuit Breaker ESS20-0..

Power systems Protection course

Series L9 UL-489 Miniature Circuit Breakers

Btdin RCBO 6000A up to 63A (2P)

209/219/229/249/279 Series Magnetic Circuit Protectors

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

FR circuit breaker - hydraulic magnetic,

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

1492-CB 1492-GH 1492-GS

ICG Switchgear Price List 2009

ELECTRICAL BUS BARS PRODUCT CATALOG #5

ELECTRICAL PRODUCTS - FUSES ATC

MINIATURE CIRCUIT BREAKER

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

QF(19) - Series Miniature Circuit Breakers

Connectors and Insulators

Cat N 3. OVERALL DIMENSIONS

Short form catalogue. Motor protection & control

RESIDUAL CURRENT CIRCUIT BREAKER

Electrical Protection

QF(13) - Series Miniature Circuit Breakers

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

G-Series. Circuit Breaker.

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Series KTU7 UL489 Molded Case Circuit Breakers

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

Timer Relays - Fixed & Adjustable

Thermal-magnetic Miniature Circuit Breaker 4230-T...

1489-M Circuit Breakers

Power System Solutions (PSS)

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

New DX 3 High rating & breaking capacity

Quik-Spec Coordination Panelboard Specifications

Carling Circuit Breakers

Miniature Circuit Breaker

circuit protection & wiring accessories

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

SubDrive Inline Constant pressure controller Additional information for Australia, NZ TOLL FREE HELP 1300 FRANKLIN

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Transfer switch OTEC open or delayed transition

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Residential and light commercial. invicta. panelboards

SWITCHGEAR DIVISION PRODUCT PROFILES

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

AR circuit breaker - Hydraulic magnetic,

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate

XT IEC Power Control Manual Motor Protectors

FUSES - Auto Glass FSH (1 AG) FSW (7 AG) FSX (8 AG) APG (European) FSO (SFE Type)

Transcription:

CIRCUIT PROTECTION BEP provides the circuit protection your vessel needs. The wide variety of fuses, breakers and holders are high quality products that have been tested through years of use in tough environments. These products are easy to use and will protect your electrical circuits and devices.

CIRCUIT PROTECTION Marine Fuses I 60 Fuse Holders I 61 Circuit Breakers I 62 Every wire on a vessel, excluding the starting circuit, requires circuit protection and Gunfleet Marine uses BEP aboard their 58 Blue Water Cruising Yacht.

60 CIRCUIT PROTECTION bepmarine.com Marine Fuses Fast-acting, corrosion resistant fuses open quickly to protect circuits from overloads and short-circuits. Time-delayed to allow temporary, harmless in-rush currents to pass but open on sustained overloads and short-circuits. Pkg 5 2 JJ05A 10 2 JJ10A 15 2 JJ15A 20 2 JJ20A 30 2 JJ30A Pkg 1 1 J01A 2 1 J02A 3 1 J03A 5 1 J05A 7.5 1 J7.5A 10 1 J10A 15 1 J15A 20 1 J20A 25 1 J25A 30 1 J30A 40 1 J40A ATM Fuses Diameter: 7/16" (11 mm) Length: 5/8" (16 mm) Maximum voltage: 32V DC ATO /ATC Fuses Diameter: 3/4" (19 mm) Length: 3/4" (19 mm) Maximum voltage: 32V DC MAXI Fuses Fuses available: 30-80A Interrupt capacity: 1000A DC Maximum voltage: 32V DC Pkg 30 1 BFHD-30A/DSP BFHD-30A 40 1 BFHD-40A/DSP BFHD-40A 50 1 BFHD-50A/DSP BFHD-50A 60 1 BFHD-60A/DSP BFHD-60A 70 1 BFHD-70A/DSP BFHD-70A 80 1 BFHD-80A/DSP BFHD-80A ANL Fuses Use with: Pro Installer ANL Fuse Holders (page 49) Length: 3.23" (82 mm) Width: 0.88" (22 mm) Stud Clearance: 0.43" (11 mm) Heavy-duty ANL Fuses Use with: 5/16" (8 mm) mounting studs Pro Installer ANL Fuse Holders (page 49) Pkg 20 1 77049020 40 1 IP40 50 1 IP50P/DSP IP50 63 1 IP63P/DSP IP63 80 1 IP80P/DSP IP80 100 1 IP100P/DSP IP100 125 1 IP125 150 1 IP150P/DSP IP150 160 1 77049160 175 1 IP175 200 1 IP200P/DSP IP200 250 1 IP250P/DSP IP250 300 1 IP300P/DSP IP300 355 1 IP355P/DSP IP355 400 1 77049400 425 1 IP425P/DSP IP425 500 1 IP500P/DSP IP500 Pkg 600 5 FANL-600-B 675 5 FANL-675-B 750 5 FANL-750-B Class T Fuses Interrupt Capacity: 20,000A DC Maximum voltage: 160V DC Diameter: 1.34" (34 mm) Length: 2.77" (70 mm) Use with: Pro Installer Class T Fuse Holders (page 49) Heavy-duty Class T Fuses Interrupt Capacity: 20,000A DC Maximum voltage: 160V DC Diameter: 1.62" (41 mm) Length: 3.03" (77 mm) Use with: Pro Installer Class T Fuse Holders (page 49) Pkg 225 1 FT-225-B 250 1 FT-250-B 300 1 FT-300-B 350 1 FT-350-B 400 1 FT-400-B Pkg 450 1 FT-450-B 500 1 FT-500-B 600 1 FT-600-B

bepmarine.com CIRCUIT PROTECTION 61 Fuse Holders ATC-6W 80-712-0039-00 ATO /ATC Fuse Holders The BEP ATC Fuse Holder provides compact, easy access to fuses with the design integrity only BEP can offer. Allows for multiple fuse holders and bus bars to be joined together, increasing the number of circuits protected Fuse holder inputs can be linked together to form a single continuous fuse holder Includes patented Contour Lock system, see-thru clip-on cover and label set Available with screw terminals or quick connect terminals Max. current/circuit: 30A; Max. current/block: 100A; Max. voltage: 32V DC; Base & cover material: polycarbonate Positions for spare fuses ATC Fuse holder: 80x90x47 mm (3.1" x 3.6" x 1.9") ATC Bus bar: 35x90x47 mm Description Pack Qty 6 Way fuse holder screw terminals w/ cover & link 6 Way fuse holder Quick Connect w/ cover & link 6 Way negative bus, 5 mm stud, cover, joiners 6 Way fuse holder screw terminals w/ cover 6 Way negative bus, 5 mm stud, cover, joiners 1/blister ATC-6W 1/blister ATC-6WQC 1/blister 80-712-0039-00 24/pack ATC-6W/B 24/pack 80-712-0039-01 BB-LINK17MM Allows two 6 way ATC fuse holders to be joined together providing twelve fused positions running off one feed. ATO /ATC Bus Bar The expandable ATC negative Bus uses the BEP Contour Lock system to allow it to be joined to the ATC fuse holder. This keeps wiring tidy and conveniently located. Current rating 100A. MAXI Fuse Holder An economical way of fusing heavy loads 30 80A. Ideal for battery charger outputs or mains feeds. 1/4" (6 mm) studs accept ring terminals and cables up to 25 mm 2 (4 gauge). Fuse is clamped between tinned brass clamps for positive connection. Covers enclose exposed terminals to meet ABYC standards. 2.8" x 2" x 1.42" (71x53x36 mm) Inline MAXI Fuse Holder For installations where space is tight and fuse needs to be installed inline with the cable. Supplied with 8 mm (8G) tails for inline connections. An economical solution to heavy-duty fusing. 3.15" x 2.15" x.6" (80x55x15 mm) 702-MFH 702-MFH-B HDBFH/DSP HDBFH Inline ATC Fuseholder WAFH-14

62 CIRCUIT PROTECTION bepmarine.com Marine Rated Battery Fuse Features: Weatherpoof IP66 design Compact heavy duty protection Insulated cap to prevent short circuit Ignition Protected Easy installation Suitable for high capacity battery banks Specifications: Voltage : 58V DC Maximum Amperage : 30A - 300A Ingress Protection: IP66 Ignition Protected: Per SAEJ1117 Interrupt : 10000A @ 14V DC, 5000A @ 32V DC, 2000A @ 58V DC Torque : Maximum 12Nm (106 in-lbs) Material: Body Ceramic, Housing & Cover: UL-rated 94V0 Thermoplastic, Ring Terminals - Tin Plated Compliances: ISO 8820-6 Available in other sizes upon request, from 30 300 amps MRBF-SET Terminal mount heavy-duty fuse holder and cover Pkg 50 1 MRBF-50A MRBF-50A-B 80 1 MRBF-80A MRBF-80A-B 100 1 MRBF-100A MRBF-100A-B 125 1 MRBF-125A MRBF-125A-B 150 1 MRBF-150A MRBF-150A-B 200 1 MRBF-200A MRBF-200A-B 250 1 MRBF-250A MRBF-250A-B 300 1 MRBF-300A MRBF-300A-B Single Pole Switchable Manual Reset Thermal Circuit Breaker Features: Weatherproof IP66 design Trip free safety feature Switchable circuit protection Easy installation/ operation Ignition Protected CE Approved Specifications: : 25-200A, 48V DC Interrupt : Main Breaker Protection Interrupt (5,000A@ 14V DC, 3,000A@ 28V DC and 1,500A@ 48V DC) Operating Temperature : -40 F (-40 C) to 185 F (85 C) Storage Temperature : -40 F (-40 C) to 260 F (125 C) Materials: Black UL-rated 94V0 thermoset plastic body Cover and lever are UL-rated 94V0 thermoplastic Marking: Standard marking includes amp/volt ratings Termination: 5/16-18 threaded studs Torque : 75 in-lbs (8.5Nm) max ing Torque : Panel or surface-mount options; 50 in-lbs (5.6 Nm) max Ingress Protection : IP66 Compliances: ABYC E-11; CE; SAE J1171 (ignition protected) Available in other sizes upon request, from 25 150 amps MRCBF-200A MRCBP-200A ing Surface 200 MRCBF-200A MRCBF-200A-B Panel 200 MRCBP-200A MRCBP-200A-B

bepmarine.com CIRCUIT PROTECTION 63 Single Pole Thermal Type Breakers s: 30 150A; 30V DC Interrupt Capacity: 3000A Operating Temperature: -25 F (-32 C) to 180 F (82 C) Storage Temperature: -30 F (-34 C) to 300 F (149 C) Applications: Auxiliary and accessory circuits trucks, buses, RVs and marine applications, battery chargers and DC audio systems. Series 184 & 185 are sealed for engine compartment and bilge area applications. Housing: Thermoset plastic; UL rated 94VO; 311ºF (155ºC). Stud insulators are provided on covered units with F (Surface ) bases; tin plated copper studs, brass rivets and stainless steel locking nuts. ing: Panel or surface Terminal Stud Torque: 50 in-lb (5.6Nm) max. Indicator: Series 184 & 185 have a unique reset mechanism providing visible indication of tripped condition Ingress Protection : IP67 Approvals: Complies with SAEJ1625, J1171 and UL1500 (Ignition protected) specifications. 184100F-01-1 Manual reset versions only switch off on electrical overload i.e. cannot be manually switched 185080P-01-1 Switchable reset versions can be manually switched to isolate the circuit Manual Reset Panel Surface 30 184030P-01-1 184030F-01-1 40 184040P-01-1 184040F-01-1 50 184050P-01-1 184050F-01-1 60 184060P-01-1 184060F-01-1 70 184070P-01-1 184070F-01-1 80 184080P-01-1 184080F-01-1 90 184090P-01-1 184090F-01-1 100 184100P-01-1 184100F-01-1 120 184120P-01-1 184120F-01-1 135 184135P-01-1 184135F-01-1 150 184150P-01-1 184150F-01-1 Switchable Reset Panel Panel Surface Surface 30 185030P/DSP 185030P-01-1 185030F/DSP 185030F-01-1 40 185040P/DSP 185040P-01-1 185040F/DSP 185040F-01-1 50 185050P/DSP 185050P-01-1 185050F/DSP 185050F-01-1 60 185060P/DSP 185060P-01-1 185060F/DSP 185060F-01-1 70 185070P/DSP 185070P-01-1 185070F/DSP 185070F-01-1 80 185080P/DSP 185080P-01-1 185080F/DSP 185080F-01-1 90 185090P/DSP 185090P-01-1 185090F/DSP 185090F-01-1 100 185100P/DSP 185100P-01-1 185100F/DSP 185100F-01-1 120 185120P/DSP 185120P-01-1 185120F/DSP 185120F-01-1 135 185135P/DSP 185135P-01-1 185135F/DSP 185135F-01-1 150 185150P/DSP 185150P-01-1 185150F/DSP 185150F-01-1 Temperature and Current

64 CIRCUIT PROTECTION bepmarine.com CLB Series Push Reset Thermal Circuit Breakers s: 5 40A; 200A @ 250V AC Interrupt Capacity Operating Temperature: 14 140 F (-10 60 C) Interrupting capacity: 2500A Resettable overload capacity: 10 x rated current Approvals: UL, CUL, TUV, CE, UL1500ISO8846 for ignition protection/marine * 5 CLB-5/DSP CLB-05 10 CLB-10/DSP CLB-10 15 CLB-15/DSP CLB-15 20 CLB-20/DSP CLB-20 25 CLB-25/DSP CLB-25 30 CLB-30/DSP CLB-30 40 CLB-40/DSP CLB-40 * DSP versions include circuit breaker, washer and boot CLB-BOOT Boot required to install breaker. PMCC-10 washer Description Boot CLB-BOOT Washer PMCC-10 CLB-20 RCD Panels We supply two Residual Current Devices (RCD) ratings (16 & 32 A). These also act as a circuit breaker (RCBO type), have an insulation rating of 400V AC, make/brake current of 6000A, a 30mA trip rating against electric shocks, and 300mA trip protection against fire risks. Due to the different mounting dimensions of the RCD s, these panels are made to be mounted separately from the main AC panel. HxWx2.5" HxWx65 mm 16 900-RCD-16A 4.5" x 5" 115x127 mm 32 900-RCD-1X16-32A 4.5" x 5" 115x127 mm 16x2 900-RCD-2X16A 4.5" x 5" 115x127 mm 32x2 900-RCD-2X32A 4.5" x 5" 115x127 mm 16x1, + 32x1 900-RCD-32A 4.5x5" 115x127 mm Cutout size - 3/8" (10 mm) inside all external edges 900-RCD-16A 900-RCD-2X16A CB Options 230 volt Type 16 RCD16A30MA Residual CB Overload 32 RCD32A30MA Residual CB Overload 63 RCD63A Residual CB Overload 16 MCB16A Miniature CB 32 MCB32A Miniature CB 63 MCB63A Miniature CB 16 124001000 Shore Fix 30 ma RCD (see chart) MCB (see chart) MCB-3WENC 6.3" x 3.6" x 3.5" 160x92x90 mm 124001000 7.87" x 4.33" x 4.53" 200x110x115 mm For installations in Australia and New Zealand to comply with AS/NZ3004 an approved double pole mains circuit breaker must be mounted upstream of the BEP Control Panel in the form of a RCD or MCB. The MCB-3WENC is an enclosure with IP65 rating. The enclosure and CB is ordered separately. The Shore Fix is already assembled, no additional item parts need to be ordered.

bepmarine.com CIRCUIT PROTECTION 65 IEG Magnetic Circuit Breakers IEG magnetic circuit breakers provide reliable circuit protection and accurate circuit control for equipment in the international market place. Designed using the latest in sensitive hydraulic magnetic technology, the IEG line adapts itself to many applications and environments. They are ideal for marine applications, data processing and business machines, as well as medical instrumentation, broadcast equipment, vending and amusement machines, military applications and wherever precision operation is required. Temperature differences which affect fuses and other thermal devices are not a concern. One important feature of this breaker line is a trip free action, which means the circuit will trip in the presence of an overload even though the handle is held in the ON position. The delay mechanism senses the fault and the contacts open. Spacing compliance: IEC specification 601, 950; VDE 0804, 0805 UL recognised; CSA certified; VDE 0660 approved; Part 101 & CE compliant Available in single or double pole; triple pole available on special orders CBS-50A-SP-IG CBS-50A-DP Single pole CBS-5A-SP 5 CBS-10A-SP 10 CBS-15A-SP 15 CBS-20A-SP 20 CBS-25A-SP 25 CBS-30A-SP 30 CBS-40A-SP 40 CBS-50A-SP-IG 50 Compatible with BEP panels. Double pole CBS-10A-DP 10 CBS-15A-DP 15 CBS-20A-DP 20 CBS-25A-DP 25 CBS-30A-DP 30 CBS-40A-DP 40 CBS-50A-DP 50 Triple pole CBS-50A-TP / 50 50 D / Pold trip coil pole Volts (V) CBS-15A-DP-TC230 230 CBS-20A-DP-TC230 230 CBS-30A-DP-TC230 230 CBS-50A-DP-TC230 230 Handle Lock Image shows handle lock as used in all our battery management panels for essential CBs to prevent accidental or unintended actuation of essential circuits CB s from either the on or off position. (ordered separately) 121-710-1101/1 IUL Magnetic Circuit Breakers Provide reliable circuit protection and accurate circuit control for equipment in the international market place. BEP uses the IUL range of circuit breakers where current requirements exceed 50A and are within 100A. Available in single and double pole with triple pole available on special orders. Single pole Double pole Triple pole CBL-50A-SP 50 CBL-50A-DP 50 CBL-80A-TP 80 CBL-60A-SP 60 CBL-60A-DP 60 CBL-100A-TP 100 CBL-75A-SP 75 CBL-100A-SP 100 CBL-75A-DP 75 CBL-100A-DP 100 CBL-50A-SP CBL-100A-DP Compatible with BEP panels.281 [7.14] M6 ISO THD.140 [3.56].402 [10.21].220 [5.59] Single Pole Double Pole M3 ISO THD.750 [19.05] Note: Tolerance.015 [.38] unless noted. Dimensions in brackets [] are millimeters. 1.940 [49.28].142 [3.61] ON OFF 1.438 [36.53] 2.060 [52.32] 1.448 [36.78] 2.060 [52.32] Panel ing Detail: Tolerance.013 unless noted. 1.859 [47.22] 2.490 [63.24].755 [19.05] 1.515 [38.48] MAX..432 [10.97] 2x Ă.156 [3.96]