ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

Similar documents
ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

Room product for Swegon s WISE System for demand-controlled ventilation

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

EXCa. Exhaust register

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

CRP. Commissioning damper, Ductwork Leakage Class 0

Conical diffuser KHAA TECHNICAL DATA

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

CTVK Supply air diffuser

DIR. VARIZON Displacement unit with adjustable spread pattern. Quick guide

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

Exhaust air diffuser HPKH + Plenum box ATTS

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

KTI Supply air valve. Product Facts. Product code example. Quick Selection

Nozzle air diffuser DYSB

KGEB Exhaust valve. Specifications. Quick Selection. Product code example Exhaust valve KGEB-100-C Mounting ring KGEZ-01

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

BLBd

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

Ceiling swirl diffusers

Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD)

Supply air diffusers RHKH and RHOH / Supply air units RHKB/RHOB (=RHKH/RHOH+ATTD)

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC

DATASHEET PRODUCT CODE EXAMPLE:

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

KSOM Control exhaust valve

CornerAir. CornerAir. Active chilled beam

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

DCV-RC DCV-RC. DCV-RC Room climate control unit. Room climate control SMART DAMPERS & MEASURING UNITS. Product description.

CHILLED BEAM IQ STAR WEGA II

Ceiling swirl diffusers

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

Ceiling swirl diffusers

ACTIVENT System. Specifications. Product code example ACTA

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA

TUBUS TUBUS. Key figures. Function Wall-mounted supply air diffusers

SDV Vane Swirl Diffusers

STRA-24 for chilled beams

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

Ventilation grilles for installation into walls, sills or rectangular

TBV - Terminal Unit. Halton TBV. Terminal Unit

Ventilation grilles for installation into walls, sills or rectangular

Swegon PACIFIC. Integrated climate beam QUICK FACTS KEY FIGURES

BRC

ADRIATIC VF. Active climate beam with cooling, heating and ventilation QUICK FACTS

OPTIVENT Housing HVSA, HVSL

NSDZ. Swirl diffusers with adjustable air control blades

Catalog Swirl diffuser DAL 358

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Ventiduct nozzle ducts

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

series RVV Variable flow rate controllers

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Swegon PACIFIC. Integrated climate beam

Slot diffusers, Round duct diffusers. IMP Klima

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

REK, LEK, ROK and LOK

Ventilation grilles for installation into walls, sills or rectangular

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

PART MATERIAL PART MATERIAL. Casing Hot galvanized steel / Option: stainless steel EN (AISI316L) Reheat coil EN 1.

OptimAir NF. Active Chilled Beam OptimAir NF. Nov

J L I e x h a u s t h o o d

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

Smoke damper EKO-SRB1

for suspended installation. Active climate beam with cooling, heating and ventilation

CADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS

SERENO

Ventiduct nozzle ducts

ROOF FAN ROOFMASTER STEC

Ceiling Swirl Diffuser DQJ

VAV TERMINAL UNITS. VVD VAV Diffusers

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

Long Throw Nozzle WDA

Round duct grille Model KG-RR

Catalog Swirl diffuser DAL 359

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins

Ventilation grilles for installation into walls, sills or rectangular

Casing Hot galvanised steel / Option: stainless steel EN (AISI316L) Reheat coil EN (AISI 304)

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

KSOF Fire damper valve

Transcription:

ADAPTTM Free Active communicative, supply air diffuser for the WISE system, ADAPT F Quick facts Supply air diffuser with an active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring, Plug & Play Communication via Modbus RTU Supplied complete with connection box, CONNECT Adapt Complemented with the WISE templates, containing detailed descriptions for planning Allows for control of: Heat alternatively, cooling valve (max. 3 actuators per master) Slaves (supply or extract air, 3 pcs) Lighting (via relay) Quick Selection AIR FLOW SOUND LEVEL COOLING EFFECT min q *) (l/s) max q (l/s) max p **) 0 Pa / db(a) 0 Pa / 3 db(a) (W) 160 0/ 0 8 480 0 0/10 6 100 62 *) The first value indicates closed damper, the second value indicates lowest adjustable air flow. **) Max. cooling effect is calculated at t=8k and for an air flow at 0 Pa and db(a). 1

Technical Description Design ADAPT is a series of flow-controlled supply air diffusers for the Swegon WISE system: The air diffuser controls the airflow with an active slot behind the frontplate. An ADAPT diffuser is always supplied with a commissioning box. Inside the air diffuser, is a controller providing all the required set points and control functions as well as a multi-functional sensor module, see figure 1. Functions in the Master diffuser Cools/heats and ventilates with air. Two stage cooling with water in the second stage, cannot be combined with heating. Controls airflow with regard to temperature and presence. Ventilation boost after longer periods of unoccupancy. Provision for wiring to a CO 2 controller. Provision for manually setting set points. Has provision for connection to a main control system (Modbus). Emergency functions for closing / opening of the damper. Control of the heating in sequence unless 2-stage cooling has been selected. Indication via LED. Indicates current operating mode and warns of malfunctions in the diffuser. Comfort control indicated by the LED if the room temperature or CO 2 value deviates too much from the set point, not activated by default. Planning WISE Templates See separate documentation, WISE Project manual, available for download from www.swegon.se. In addition, Swegon sales personnel can supply WISE templates containing descriptions with detailed information regarding functionality, flowcharts, wiring diagrams and demarcation list for various constructions. 1 Sensor module A sensor module is integrated in all ADAPT supply air diffusers, containing the following functions: A temperature sensor controls the airflow to maintain required temperature in the room. A presence detector makes it possible to save additional energy by lowering the airflow when there are no occupants in the room. The presence signal from the air diffuser can be fetched for controlling the lighting, for instance, and in this way save more energy. Connectivity In each delivery of a master diffuser, a CONNECT Adapt connection box is included: The connection box replaces the coupling box which otherwise is mounted on a wall/ceiling for wiring a 24 V supply voltage to the air diffuser and Modbus networks. Both air diffuser and connection box are equipped with RJ4 quick-fit connectors for quick and fault-free wiring. The device has provision for connection to a main control system (BMS/SCADA) via ModBus. Accessory cable, LINK Modbus (RJ12) can be connected between air diffuser and connection box. The air diffuser will then be ready for the main control system. From the connection box, control functions for heating in sequence, CO 2 sensor and set point adjuster, can also be connected. 2 Figure 1. The sensor module of with connection for TUNE Adapt. 1. Temperature detector 2. In-operation indicator, green, red and orange LED. 3. Presence detector Figure 2. Connection box, CONNECT Adapt. Swegon reserves the right to alter specifications. 1013 www.swegon.com 2 3

Installation A detailed installation instruction is enclosed with each delivery and can also be downloaded from www.swegon. 1. Adapt Free is suspended from the ceiling. Female-threaded grommets are available on the top of the air diffuser. 2. Secure the connecting duct by means of pop rivets. 3. The bottom plate can be dismantled by pressing the fixing pins of the bottom plate outward, which will loosen it from the upper cone. Secure the bottom plate to the upper cone with the safety cord, press together the S-hook to prevent it from coming loose. N.B.! Disconnect the electric cable (C) from the motor. B A C The commissioning box is made of galvanized sheet steel with internal insulation. Maintenance The ADAPT air terminals can be cleaned on the outside, if necessary, using lukewarm water with dishwashing detergent added. The duct system is accessible without need for tools. (See the separate installation instruction) Declaration Declaration of Construction Materials is available for download from www.swegon.com. Electrical data ADAPT is supplied with power via the connection box. For more information about various wiring and room solutions, see the Technical Section. Supply voltage 24 V AC ±10 % Max. power consumption 3 VA Cable rating 0,6 A Ambient temperature 0 C - +0 C Forms of delivery Some of the ADAPT-products are available from stock with standard settings. At delivery, a master air diffuser contains a complete air diffuser with commissioning box, connection box CON- NECT Adapt and metre long RJ4 cable LINK Adapt. Delivery of a slave air diffuser contains a complete air diffuser with commissioning box and metre long RJ4 Figure 3. Adapt Free, installation. A *) M8 threaded rod and lock nuts. B *) Securing to the ceiling or load-carrying structure. *) N.B.! Parts A and B are not included at delivery. Standard settings Temperatures ( C) Presence 22 ± 1 K Absence 22 +3 / -2 K Night-time cooling 18 Commissioning Normally, the ADAPT air terminals are preset from the factory based on design values. The TUNE Adapt hand-held terminal is used for manually checking the current air flow through the air diffuser, and for changing set points, if required. For more information, see the installation - Commissioning - Maintenance instruction as well as the TUNE Adapt user manual. Materials and finish ADAPT air terminals are made of galvanized sheet steel, with parts made of plastic, rubber and also contain electronic components. The ADAPT air terminals are powder coated in Swegon s white interior standard colour RAL 9010, both on the inside and on the outside. The sensor module and connection box are made of ABS plastic. Morning heat 2 Airflows (l/s) Absence Min. airflow Swegon reserves the right to alter specifications. 1013 www.swegon.com Max. airflow The smallest size 0/ 10 60 The largest size 0/10 90 Air quality (ppm) Min. Max. CO 2 800 1000 Presence Switch on delay Switch out delay 0 sec. min. Communication Modbus RTU by RS-48 Modbus ID 1 Speed 38,0 bps Bit length 8 bits Stop bits 1 bit Parity None 3

Sizing The specified sound levels db(a) are applicable to rooms with an equivalent sound absorption area of 10 m 2 (4 db room attenuation). The throw L 0.2 is measured under isothermal discharge conditions. Recommended max. permitted temperature below room temperature is 12 K. All technical data applies to 360 distribution pattern. For calculating the air stream propagation, air velocities in the occupancy zone, or sound levels in rooms with other dimensions, we refer to our ProAir Web calculation program. ProAir Web is available at www.swegon.com. Engineering graphs Air flow Pressure drop Sound level Throw The diagrams should not be used for commissioning. The db(c) value is normally 6-9 db higher than the db(a) value. The throw can be read at the design max. air flow and pressure drop. The slot opening of the diffuser is shown at 0, 1, 3, 6 and mm. Sizing example size 0: Given airflow 10-0 l/s at P t 0 Pa. Max. sound level db(a) Max. throw at line = 3.2 meters. Sound data Sound power level, L w (db) Table, K ok Mid-frequency (Octave band) Hz 63 12 20 00 1000 00 00 8000 ADAPT F 160 p t Pa 00 0 0 0 db(a) 3 0 01 160 7 2-3 1-1 -6-14 -17 0 8 2-1 2-1 -7-18 -21 Tol. ± 2 2 2 2 2 2 2 2 100 0 2 Sound attenuation DL Table DL Mid-frequency (Octave band) Hz 63 12 20 00 1000 00 00 8000 160 21 16 24 21 19 10 11 11 0 18 13 23 21 14 10 10 12 Tol. ± 2 2 2 2 2 2 2 2 10 3 4 10 0 100 0 l/s 0 0 100 0 0 0 00 m 3 /h 0,3 0,4 0, 1 2 3 4 10 l 0,2 m ADAPT F 0 p t Pa 00 0 0 01 0 0 100 db(a) 3 0 2 10 3 4 10 0 100 0 l/s 0 0 100 0 0 0 00 m 3 /h 0,3 0,4 0, 1 2 3 4 10 l 0,2 m 4 Swegon reserves the right to alter specifications. 1013 www.swegon.com

Dimensions and weights ØA ØD B C E Weight, kg 160 380 9 3 123 1 6,8 0 46 199 390 9 0 10,2 Ordering key Product Circular active air diffuser for ceilings ADAPT F d -bbb -c Version: Connection dimensions: M: Master S: Slave N.B.! Specify absence, min./max. airflows in your specification! Standard range: : 160, 0 Accessories DETECT Quality Temperature and CO 2 sensor with set point selector knob TUNE Adapt Hand-held terminal for reading/changing settings TUNE Temp Temperature adjuster LINK Modbus LINK Adapt SPLIT Link FIX Link POWER Adapt ACTUATOR RJ12-cable for connecting up Modbus RTU RJ4 cable for connecting up in other lengths Split connector For securing cords to ducts, etc. Transformer Valve actuator, on/off VALVE Radiator valve Figure 4., dimension figure. ADAPT Relay ADAPT TR Relay for light or heat control Semi-conductor relay for lighting or heat control CABLE Ext Extension cable between box and air diffuser LINK Wa Network cable for Modbus, complies with the EIA-48 standard Each accessory is described in more detail in a separate product sheet available at www.swegon.se. Varje tillbehör finns redovisat på separat katalogblad som kan hämtas på www.swegon.se. Swegon reserves the right to alter specifications. 1013 www.swegon.com