Spin Klin 12" Super Flow

Similar documents
3 Spin Klin Battery Operation and Maintenance Manual

Spin Klin 3"-4" Apollo Angle

4" Spin Klin Twin Apollo Battery. Service & Maintenance Manual

Spin Klin 4" Apollo Twin

SPIN KLIN GALAXY. Service & Maintenance Manual

ARKAL FILTERS CATALOGUE

inlet/outlet connection flow rates filtration degrees max. working pressure

APOLLO DISC-KLEEN FILTERS

Chemical disc filters, Arkal Amiad, w w w. a r k a l - f i l t e r s. c o m

To ensure proper installation, digital pictures with contact information to before startup.

Check List for Optimal Filter Performance

AMIAD Automatic Filters

ARKAL SCREEN LINE H - SERIES Hydraulically Operated Self-Cleaning Screen Filter SERVICE & MAINTENANCE MANUAL

Weld tabs are standard on all media tanks and screen filter housings.

BERMAD Irrigation. Media Filtration Systems. Model Filters. Features and Benefits. Typical Applications

SST & PRO II Media Filtration Systems Installation and Operation Instructions

PRO II & SST Media Filtration Systems Installation and Operation Manual

Aqua-Clear Fiberglass Sand Filters

SCREEN FILTERS Series 2000 & 2200

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

PLASTIC Filters. Durable high quality Plastic filters for wide range of filtration applications

PUMPS AND FILTRATION

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL

Purging Air From Divider Block Lubrication Systems

AMIAD "ABF-L" FILTER SERIES

Operation and Maintenance Instructions for Bettis GVO-C Series GVO-CLP-SR Pneumatic Actuators

CIRCLE SEAL CONTROLS

Tekleen ABW USERS AUTOMATIC FILTERS, INC. MANUAL

Tekleen LPF USERS AUTOMATIC FILTERS, INC. MANUAL

GEBCO (PTY) LTD - Netafim Product List - 1st March 2012 All Prices are stated exclusive of VAT & are subject to change without prior notice

CIRCLE SEAL CONTROLS

Installation and Service Instructions

Installation And Operation Instruction Manual INSMAN-101. Sand Media Filters. Phone: Toll-Free:

Operation and Maintenance of Mechanical Self-Cleaning Filters. Maynard King CB Tubecraft div of K&D Pratt

Industrial automatic self-cleaning filters made in stainless steel AISI 316

CLAY VESSEL MANUAL (VC Series Vessels)

MICHIGAN FLUID POWER

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

New Filtration Products from LAKOS

TAVLIT FILTERS. Quality that lasts

HTX-HTH SEPARATORS I&O MANUAL

HYDROCYCLONE SAND SEPARATORS

To ensure proper installation, digital pictures with contact information to before startup.

MAP Automatic Strainers In-Line Series

AQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES

Installation and Operation Instruction Manual FWINSMAN303. Yardney - Filtaworx FW06EX - FW10

IRRIGATION EQUIPMENT LTD.

RX-AFRO3-AQ Installation Manual

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions

Installation and Operation Instruction Manual INSMAN-201. Industrial Multi Media Single Tank

Surface CIMV, Low Flow, HTV, Manual

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

WARCO CHEMAG SERIES GH FILTERS

LAKOS AUTOMATIC SELF-CLEANING SCREEN FILTERS

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

Value Super Filter Max Installation Manual

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

NUMBER: S.M. REF.: Refer to 2.5 ENGINE: 60 DATE: January 2007

F76 Water Filters. Specifications. and MV876 Automatic-Backwash Control Accessory (not included)

Backflushing Filter AutoFilt RF3

DP556 Pump. 55:1, Air-operated, Grease. General. Operation. Technical Data. Installation. Mounting with Reinforced Cover (Recommended)

Filtomat M100/MG Filters

Technical Manual. Models: Standard Softeners High Efficiency Softeners Combination Softeners S150 S250 S250 OD S350 S550 S650 S650 OD Q850 Q850 OD

Installation & Operation Instruction Manual FWINSMAN300. Yardney - Filtaworx FW02 - FW03

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

US Water Systems Magna Pre-Filter

B21 Series BASOTROL Gas Valve

APP pump instruction APP and APP 16-22

AIRGO MISTING SYSTEM MAINTENANCE

Agxcel GX12i Chemical Injection System

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Technical Information

Series RFL In-Line Filter

RP-CS 2-98 CERTA-SEAL LIQUID BAG FILTERS WITH THE MATCHED PERFORMANCE DESIGN. Products

PRESSURE GAGES AND TEST TAPS

PROMAX INSTRUCTION MANUAL

DT34 and DT54 Series Rotary Sprinklers

Installation & Parts Manual K-7, K-15, & K-30 Air Actuated & Differential Check Valves

Series RFLD Duplex In-Line Filter

INSTALLATION, OPERATING AND SERVICE MANUAL

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Section 2: Big Bubba Filtration System

Be sure to order the correct number of elements: OLF 15 = 1, OLF 30 = 2, OLF 45 = 3, OLF 60 = 4

Irrigation Systems. Product Catalog. Yardney Water Management Systems, Inc Box Springs Blvd. Riverside, CA 92507

800S Series. Based on proven technology. When creating the 800S Series. sprinkler, we started with. technology that works. Then

GL Ludemann Y-Strainers

Starting up hydraulic systems

PRO-II SERIES SAND MEDIA FILTRATION SYSTEMS Kits and Parts Listing

MP18/SIC & SIO Stacking Valve System Technical Information Manual

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

90 SERIES SELF CLEANING WATER FILTER OPERATION & MAINTENANCE MANUAL

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

65 Series. Valve Operation Manual

Pilot-Operated Regulators

All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679.

BLACKMER BYPASS VALVES

MODEL NO. SK-61-12V 12 VOLT SKID MOUNTED LAWN & GARDEN SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Transcription:

Spin Klin 12" Super Flow w w w. a r k a l - f i l t e r s. c o m

Galaxy Super Flow Spin Klin Battery Standard Automatic Backwash Operation and Maintenance Manual Filtration Process During filtration, water flows from the inlet manifold, through the 12 inlet valve into the filter, and through the 12 manual outlet valve (which serves as an isolation valve only, when needed). Filtered water gathers in the outlet manifold and flows into the user system. Drain valve is close. INLET VALVE MANUAL OUTLET VALVE DRAIN VALVE Backwash Process The backwash process is initiated by the control unit according to differential pressure between the inlet and outlet or by time sequence, set by the user. The first solenoid transmits a command to filter no. 1's valves. The Inlet valve shuts off and the drain valve opens. Filter no. 1 is now in backwash mode. The 51 Spin Klin spines in filter no. 1 operate simultaneously, releasing the compressed discs. Tangential jets of clean water are pumped at high pressure in the opposite direction through nozzles at the center of the spine. The discs spin free and clear, loosening the trapped solids. Solids are quickly and efficiently flushed out though the drain. The filtered backwash water is supplied by the other filters through the outlet manifold. The contaminated water from the backwashed filter drains through the drainage manifold. Filters backwash will take 20-30 seconds (valve type and size effects the total flushing time). When the time elapses the control unit stops the backwash signal to the solenoid. The solenoid releases the command, allowing the valves and the discs of the 51 spines to return to filtration mode. Once filter no. 1 is in the filtration position again, the control unit sends a command to begin the backwash process of filter no. 2.

Spin Klin Technology- Spine Model 2 General: The Spin Klin discs are stacked on the Spin Klin spine. The discs are color-coded according to nominal micron size and are assembled according to your water filtration Filtration Mode Backwash Mode requirements. The spine assembly has a spring compression unit and an internal piston, which are used to alternately compress and release the discs during filtering and backwashing cycles. Filtration Mode: During the filtration process the filtration discs are tightly compressed together by the spring and the differential pressure, thus forcing the water to flow through the crisscross grooves of the discs. INLET Backwash Mode: During backwash the discs are released hydraulically, simultaneously with the pressure release. Multi-jet nozzles OUTLET TO DRAIN BACKWASH WATER INLET provide tangential spray on the loosened discs, causing them to spin and flush out the retained solids to the drain. Valves Operation Each filter is equipped with 2 automatic valves (butterfly or other, according to the application s requirements) to switch between filtration and backwash mode. The 12 manual outlet valve serves as an isolation valve only, when needed. Filtration mode: The inlet valve permits flow from the inlet manifold through the filter, into the system. Flushing mode: The inlet valve closes and the drain valve opens, causing reverse flow through the filter, ejecting impurities via the drain manifold. Operation is initiated by an electric solenoid. The valves are operated by means of pneumatic, hydraulic or electric source. Technical Data Maximum pressure 10 bar 115psi Minimum backwash pressure 3 bar 42 psi Backwash flow rate per unit 500 m 3 /hr 2200 gpm Filtration surface area per unit 44,880 cm 2 6,955 in 2 Filtration volume 68,000 cm 3 4,150 in 3 Maximum temperature 70 C 158 F Please consult Arkal's engineering department.

Galaxy Super Flow System An example of 4 Super Flow filters system layout drawing (Stainless Steel 316 or Carbon Steel Polyester Coated) Installation A. Ensure that the inlet and outlet orientation is correct (shown by arrows on filter). B. Prior to start-up check for any transport damage to the unit (the system operates under pressure!). C. Connect backwash drainage line. D. Lids need to be properly closed and sealed. Start-up Operation Open the inlet valve. Start the backwash cycle, ensuring that all system components function correctly. Filter Load-up during Start-up Adjust the downstream (flow control) valve (if available) until downstream pressure reaches the recommended backwash pressure. Flush few cycles until clean, at least once for each filter. Slowly reopen the downstream valve. If the pressure difference remains high, check and see if the flow rate is too high. Excessive flow rate through the filter may increase pressure loss.

Galaxy Super Flow Headloss Chart P [bar] 0.5 0.45 0.4 0.35 0.3 dp [Bar] 0.25 0.2 0.15 0.1 0.05 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [m 3 /h] Filtration Grades Color code Blue Yellow Red Black Brown Green Gray Micron 400 200 130 100 70 55 20 Mesh 40 80 120 140

Control system scheme Back Flushing Controller FLUSHING TIME PD P IN OUT S U P E R F L O W OUT IN T B U T E R F L Y V A L V E IN OUT OUT Control Refer to the manufacturer s handbook before installing the controller (In case control system is supplied with the Galaxy Super Flow system). Ensure that the voltage of both the solenoid unit and controller is correct. Set the manual operation button to automatic. Check that the P hydraulic switch HIGH and LOW pressure lines are correctly connected to the right ports. Set the starting backwash switch to P of 5-7 meters (6-8psi). Set the controller to flush time of 20-30 seconds and dwell time of 10 seconds. These settings may require adjustment to conform to local water conditions. Normally, a 1 to 3 hour interval between backwashes is recommended.

Spin Klin - System Maintenance Check inlet /outlet pressure: If pressure differential is above 5 m / 7 psi: Start the automatic backwash process of the Spin Klin Galaxy Super Flow filter. In case that the pressure differential after backwash remains high check for possible failures. Check for leakages from the drain manifold: In case there is a leakage of water during the filtration stage, check for possible failure at the valve. Backwash controller performance: Check that the controller timing parameters are correctly adjusted and activate automatic backwash cycle. In the event of possible failure at the backwash controller, check for possible failures. Water-formed deposits: During the filtration process, water-formed deposits may settle on the filtration discs and clog the filter. The formation and composition of these deposits depend on the water quality and on environmental conditions like temperature, ph, light, flow velocity, duration of filtration and more. Common water-formed deposits are: Biological or organic deposits (mostly mucous or oily by touch; beige, brown or green in color) Manganese or iron compounds (black, brown or orange deposits) Carbonates (white or gray deposit) Combinations of the above If these deposits cannot be eliminated by pretreatment of the water, we recommend cleaning the filter periodically with a suitable cleaning solution. Make sure the cleaning solution is compatible with the filter materials.

Seasonal Maintenance Cleaning the Discs To guarantee thorough cleaning the following steps should be taken: Close the water inlet after backwashing the systems. Make certain that there is no pressure in the system and open the lids (Figure 1). Figure 1 Figure 2 Figure 3 Unscrew the spine using a ranch with a special spine nut (Arkal Catalog No. 5076 0097) and take out the spine out of the Super Flow vessel (Figure 3). Unscrew the butterfly nuts on the filtration elements (Figure 4). Remove the disc sets (for convenience we recommend using a plastic bag (Figure 5). Figure 4 Figure 5 Cleaning solution Figure 6 Tie each set on a string, place them in a suitable cleaning solutions, soak them for a few hours and then rinse them well with clean water to remove remaining deposits and chemicals (Figure 6). Figure 7 Figure 8 Figure 9 Ensure that the correct quantities of discs are assembled on the spines: when the discs are pressed with two hands, the top disc should be level with the imprinted lines on the outside of nozzles pipes. Reassemble the tightening cylinders into the spines (Figure 7), screw back the spines into their seats and seal the vessels ports by the lids (Figure 8, 9). Attention: When carrying out any seasonal maintenance, service, or cleaning of the discs after backwashing the system and closing the water inlet, make certain that there is no pressure in the system!

Optional (should be added to specific customers only): Suitable cleaning solutions for cleaning filtration discs outside the filter: For biological deposits (biofilms) - up to 5% chlorine (NaClO) or peroxide (H 2 O 2 ) solution For organic deposits - up to 5% detergent solution (based on NaOH) For manganese deposits - up to 10% citric acid solution For iron and carbonate deposits - up to 5% acid solution (as HCl or H 3 PO 4 ) Do not expose filtration discs to chemicals longer than absolutely necessary (max. 4 hours). For your personal safety, strictly follow the safety instructions of the chemical supplier. For online cleaning procedures, please contact your ARKAL consultant.

Identifying Malfunctions in the Galaxy Super Flow system No Backwash Operation Check inlet and outlet pressures Check controller manually operate the backwash cycle No command transfer Functioning correctly Some commands do not function Check electrical source Check electrical source Check solenoid electrical connectors Repair or replace the solenoid Check the valves Command not received Receives command Check the air supply control tube Check valves actuators - Repair or replace the booster valve if needed Check & clean the drain manifold and pipe Contact your local distributor

Continuous or Non-stop Backwashing Continuous backwash Non stop backwash cycle Disconnect the control pipes from the valves Check inlet / outlet pressure Check pressure differential gauge and replace if needed Check controller described above Contact your local distributor Command transfer No command transfer Check controller No command transfer Command transfer Replace control panel Disconnect the drain manifold Locate the nonfunctioning valve Remove any obstruction Repair the valve if needed Check the solenoid No command transfer Command transfer Replace the solenoid if needed Check the booster valve No command transfer Command transfer Replace the booster valve if needed Contact your local distributor 12 SK super flow 07-2007 ENG

Drawings 12" Spin Klin super flow Batteries w w w. a r k a l - f i l t e r s. c o m