FSAF24(-S) US, FSAF120(-S) US

Similar documents
Belimo is the Worldwide Leader in Fire and Smoke Actuation

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

AF Series Spring Return Direct Coupled Actuator

ZG106 or ZG 107 bracket

LF Series At A Glance

AF Series Spring Return Direct Coupled Actuator

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

Versatile and Powerful

Versatile and Powerful

LF Series Spring Return Direct Coupled Actuator

Minimum 27 in-lb Torque

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default) 3/4" Centered (Field Selectable)

Minimum 27 in-lb torque

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

Torque min. 35 in-lb, for control of air dampers

Minimum 18 in-lb Torque

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

AFXUP-S (p. 19) AFB24-MFT. AFXUP (p. 19) AFBUP-S

Product Cross Reference

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

LF Series Spring Return Direct Coupled Actuator

BELIMO CONTROLS

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

GM Series Direct Coupled Actuator

AM Series Direct Coupled Actuator

G3 (D) 3-way Globe Valve, Bronze Trim

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

F6300L, 12, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

G6 C(S)(LCS) 2-way Pressure Compensated Flanged Globe Valve

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Accessories. Technical Data Extension Height 2" Material. Stainless Steel. Bearing TR LRB (X) ARB (X) TF LF AF. Extension Bracket CCV-EXT-Kit

F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Mounting Installation Instructions LM, NM, AM, GM

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6200L, 8, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

G7 (S) 3-way Mixing Flanged Globe Valve, Bronze or Stainless Steel Trim

RUS-L24-MOD Electric 24 Volt Modulating Control Damper & Louver Actuator

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

Installation Instructions

AF24-MFT95 US Proportional Damper Actuator, Spring Return Fail-Safe, 24 V for Use with Honeywell Electronic Series 90, or a 0 to 135Ω input

Fire and Smoke Damper Actuator product overview

LF24-SR US TF24-SR US TFX24 US LF24 US. B3 B Three-way Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem

Installation Instructions

RUS-L24-MOD Electric 24 Volt Modulating Control Damper Actuator

M9216 Series Electric Spring Return Actuators

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.

Commercial Actuator Selection Chart Non-Spring Return

MA40-704X Series MA41-707X Series MA41-715X Series

M9208-xxx-x Series Electric Spring Return Actuators

Damper Actuators Non-Spring Return

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

Installation Instructions

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

M9208-xxx-x Series Electric Spring-Return Actuators

B2/B3 Series Characterized Control Valve, Non-Spring Return Actuator

Mounting Installation Instructions NKQ, GK

M9220-xxx-3 Electric Spring Return Actuators

M9203-xxx-2(Z) Series Electric Spring-Return Actuators

M9220 Series Electric Spring-Return Actuators

M9208-xxx-x Series Electric Spring Return Actuators

F6 Series 2-Way, Victaulic Butterfly Valve

NV Direct Coupled Globe Valve Actuator

M9208-xxx-x Series Electric Spring Return Actuators

Non-Spring Return EconoDrive Floating Actuator

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

G780, 3-Way, Mixing Flanged Globe Valve

MS Series MS Series MS Series

Spring-Return Damper Actuator NF24(-S)

VA9208-xxx-xx Series Electric Spring Return Actuators

Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

SAV Electronic Valve Actuator

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators

M9203-xxx-2(Z) Series Electric Spring Return Actuators

2006 Product Range Overview. Belimo Project: One Bellevue Center, Seattle, Washington

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

F6125HD, 5, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Electro Controls. Damper Actuators / Valve Motors WattsIndustries.co.uk

VA-4233-GGx Series Electric Valve Actuators

Strobic Air, a Met-Pro Product Recovery/Pollution Control Technologies Business, is pleased to submit the attached proposal for your consideration.

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Actuators for heating, ventilation, air-conditioning 2. LM-4 -CD. Product Information Damper actuators. i

Type A - PICV Actuator Series

Powers TM Controls EA 338 Electronic Actuator

M9220-xxx-3 Electric Spring Return Actuators

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Pressure Independent Characterized Control Valves (PICCV)

See «Overview of types»

Transcription:

FSAF4(-S) US, FSAF10(-S) US On/Off, Spring Return, Meets 50 F [11 C] for Half Hour, 75 Seconds Torque min. 133 in-lb, for control of air dampers Technical Data FSAF4(-S) US, FSAF10(-S) US Power supply FSAF4(-S) US 4 VAC ± 0%, 4 VDC -10% +0% FSAF10(-S) US 10 VAC ± 10%, 50/60 Hz Power consumption FSAF4(-S) US running 7.5 W, 10 VA,.4 A holding W, 4 VA,.15 A FSAF10(-S) US running 50/60Hz: 9.5 W, 11 VA,.1 A holding 3.5 W, 6 VA,.05 A Transformer sizing 10 VA (Class power source 4V only) Electrical connection motor 3 ft, 18 ga, color coded leads 1/ conduit connectors -S models 3 ft, 18 ga, 4 leads appliance cable 1/ conduit connectors Overload protection electronic throughout 0 to 95 rotation Angle of rotation mechanically limited to 95 Torque 133 in-lb [15 Nm] constant Direction of rotation spring reversible with cw/ccw mounting Position indication visual indicator, 0 to 95 (0 is spring return position) Manual override 3mm hex crank (shipped w/actuator) Running time <75 sec. constant, independent of load spring <0 seconds nominal Humidity 5 to 95% RH non-condensing Ambient temperature normal duty - F to 1 F [-30 C to 50 C] safety duty 3 on/off cycles after 30 minutes at ambient temperature of 50 F [11 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEMA type 1 / IP40 Housing material zinc coated metal Gears permanently lubricated Agency listings culus listed to UL873 and CAN/CSA C. No.4 Noise level (max) 45 db (A) spring return 6 db Servicing Maintenance free Quality standard ISO 9001, 5 year Belimo warranty Weight (standard / -S model) FSAF4(-S) US 5.7 / 6. lbs (.6 /.8 kg) FSAF10(-S) US 6.1 / 6.6 lbs (.8 / 3 kg) Application For two position control of UL555S rated dampers in HVAC. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft or jackshaft 3/8 to 1.05 in diameter by means of its universal clamp. A crank arm and mounting brackets are available if the actuator cannot be direct coupled to the jackshaft or damper shaft. Square footage of damper operated will depend on make and model of damper. Typically 1 sq.ft. minimum up to 4 sq.ft maximum will be operated for UL555S applications. Operation The FSAF series actuators provide true spring return operation for reliable fail-safe application and positive close-off on UL555S dampers. The spring return system provides constant torque to the damper with, and without, power applied to the actuator. The FSAF series provides 95 of rotation and is provided with a graduated position indicator showing 0 to 95. The FSAF has a manual positioning mechanism which allows the setting of any damper position within its 95 of rotation. The actuator is shipped in the zero fail-safe position to provide automatic compression against damper gaskets for tight shut-off. When power is applied, the manual mechanism is released and the actuator drives toward the open position where it stops rotating. The manual override can also be released physically by the use of a crank supplied with the actuator. SAFETY NOTE Screw a conduit fi tting into the actuator s bushing. Jacket the actuator s input and output wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. Dimensions (Inches [mm]) Standard: 1/" to 1.05" Optional* 3/8" to 3/4" 3/8" to 5/8" *with K4 US clamp 0.65" [16.5] 3.5" [8.7].4" [57] 0.39" [10] 0.35" [9] 3.86" [98] 0.19" [5] 3.15" [80].64" [67] 1.97" [50] 10.59" [69] 5.85" [148.5] 0.6" [6.5] 004 D0 1.93" [49] FSAF4-S US, FSAF10-S US Auxiliary Switch xspst 7A resistive,.5a inductive at 10V or 50V, UL Approved, double-insulated, one switch at 10, one adjustable from 30 to 90 171

FSAF10(-S) US, FSAF4(-S) US On/Off, Spring Return, Meets 50 F [11 C] for Half Hour, 75 Seconds Accessories (AF series accessories may be employed) IND-AF Damper position indicator K4 US Universal clamp for 3/8 to 3/4 shafts K4-1 US Universal clamp for up to 1.05 dia. jackshafts K4-H Universal clamp for hexshafts 3/8 to 5/8 KH-AF Crank arm for up to 3/4 round shaft (Series ) KH-AF-1 Crank arm for up to 1.05 jackshaft (Series ) KH-AFV V-bolt kit for KH-AF and KH-AF-1 Tool-01 10 mm wrench ZDB-AF US Angle of rotation limiter ZG-100 Universal mounting bracket ZG-101 Universal mounting bracket ZG-10 Multiple actuator mounting bracket ZG-103 Universal mounting bracket ZG-104 Universal mounting bracket ZG-106 Mounting bracket for Honeywell Mod IV replacement or new ZG-107 Mounting bracket for Honeywell Mod III or Johnson Series 100 replacement or new ZG-108 Mounting bracket for Barber Colman MA 3../4.., Honeywell Mod III or IV or Johnson Series 100 replacement or new ZG-AF Crank arm adaptor kit for AF/NF ZG-AF108 Crank arm adaptor kit for AF/NF ZS-100 Weather shield (metal) ZS-150 Weather shield (polycarbonate) ZS-300 NEMA 4X housing 965-00001 1mm form fit square shaft adaptor For an overview of how to apply the accessories, see Belimo Mechanical Accessories and refer to the Belimo Mounting Methods Guide. NOTE: When using FSAFxx (-S) US actuators, only use accessories listed on this page. Wiring Diagrams 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuator may also be powered by 4 VDC. 4 No ground connection required. Double insulated. 5 For end position indication, interlock control, fan startup, etc., the FSAF4- S US and FSAF10-S US incorporates two built-in auxiliary switches: x SPST, 7A resistive,.5 inductive @10/50 VAC, UL Approved, one switch is fi xed at 10, one is adjustable from 30 to 90. Meets UL requirements without the need of an electrical ground connection. Meets culus or UL and CSA Standard requirements without the need of an electrical ground connection. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Typical Specification Large combination fi re and smoke dampers are to be operated by Belimo FSAF series actuators. Manufacturer shall provide 5 year warranty. Actuators shall draw no more than 11VA at 10V or 4V. Where auxiliary switches are required for signaling, starting fans, or position indication, -S model actuators, damper blade, or proximity switches shall be provided. Smaller dampers shall employ Belimo FSLF or FSNF actuators per damper manufacturer recommendations. FSAF4 US and FSAF10 US W19_08 17

FSAF30(-S) US On/Off, Spring Return, 50 F [11 C] for Half Hour, 75 Seconds Torque min. 133 in-lb, for control of air dampers Technical Data FSAF30(-S) US Power supply 30 VAC ± 14%, 50/60 Hz Power consumption running 50/60Hz: 11 W, 1 VA,.07 A holding 3.5 W, 6 VA,.03 A Transformer sizing 10 VA (Class power source 4V only) Electrical connection motor 3 ft, 18 ga, color coded leads 1/ conduit connectors -S models 3 ft, 18 ga, 4 leads appliance cable 1/ conduit connectors Overload protection electronic throughout 0 to 95 rotation Angle of rotation mechanically limited to 95 Torque 133 in-lb [15 Nm] constant Direction of rotation spring reversible with cw/ccw mounting Position indication visual indicator, 0 to 95 (0 is spring return position) Manual override 3mm hex crank (shipped w/actuator) Running time <75 sec. constant, independent of load spring <0 seconds nominal Humidity 5 to 95% RH non-condensing Ambient temperature normal duty - F to 1 F [-30 C to 50 C] safety duty 3 on/off cycles after 30 minutes at ambient temperature of 50 F [11 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEMA type 1 / IP40 with fl exible conduit Housing material zinc coated metal Gears permanently lubricated Agency listings culus listed to UL873 and CAN/CSA C. No.4 Noise level (max) 45 db (A) spring return 6 db Servicing Maintenance free Quality standard ISO 9001, 5 year Belimo warranty Weight 6.9 lbs (3.1 kg) Application For two position control of UL555S rated dampers in HVAC. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft or jackshaft 3/8 to 1.05 in diameter by means of its universal clamp. A crank arm and mounting brackets are available if the actuator cannot be direct coupled to the jackshaft or damper shaft. Square footage of damper operated will depend on make and model of damper. Typically 1 sq.ft. minimum up to 4 sq.ft maximum will be operated for UL555S applications. Operation The FSAF series actuators provide true spring return operation for reliable fail-safe application and positive close-off on UL555S dampers. The spring return system provides constant torque to the damper with, and without, power applied to the actuator. The FSAF series provides 95 of rotation and is provided with a graduated position indicator showing 0 to 95. The FSAF has a manual positioning mechanism which allows the setting of any damper position within its 95 of rotation. The actuator is shipped in the zero fail-safe position to provide automatic compression against damper gaskets for tight shut-off. When power is applied, the manual mechanism is released and the actuator drives toward the open position where it stops rotating. The manual override can also be released physically by the use of a crank supplied with the actuator. SAFETY NOTE Screw a conduit fi tting into the actuator s bushing. Jacket the actuator s input and output wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. Dimensions (Inches [mm]) Standard: 1/" to 1.05" Optional* 3/8" to 3/4" 3/8" to 5/8" *with K4 US clamp 0.65" [16.5] 3.5" [8.7].4" [57] 0.39" [10] 0.35" [9] 3.86" [98] 0.19" [5] 3.15" [80].64" [67] 1.97" [50] 10.59" [69] 5.85" [148.5] 0.6" [6.5] 004 D0 1.93" [49] FSAF30-S US Auxiliary Switch xspst 7A resistive,.5a inductive at 10V or 50V, UL Approved, double-insulated, one switch at <10, one adjustable from >30 to 90 173

FSAF30(-S) US On/Off, Spring Return, 50 F [11 C] for Half Hour, 75 Seconds Accessories (AF series accessories may be employed) IND-AF Damper position indicator K4 US Universal clamp for 3/8 to 3/4 shafts K4-1 US Universal clamp for up to 1.05 dia. jackshafts K4-H Universal clamp for hexshafts 3/8 to 5/8 KH-AF Crank arm for up to 3/4 round shaft (Series ) KH-AF-1 Crank arm for up to 1.05 jackshaft (Series ) KH-AFV V-bolt kit for KH-AF and KH-AF-1 Tool-01 10 mm wrench ZDB-AF US Angle of rotation limiter ZG-100 Universal mounting bracket ZG-101 Universal mounting bracket ZG-10 Multiple actuator mounting bracket ZG-103 Universal mounting bracket ZG-104 Universal mounting bracket ZG-106 Mounting bracket for Honeywell Mod IV replacement or new ZG-107 Mounting bracket for Honeywell Mod III or Johnson Series 100 replacement or new ZG-108 Mounting bracket for Barber Colman MA 3../4.., Honeywell Mod III or IV or Johnson Series 100 replacement or new ZG-AF Crank arm adaptor kit for AF/NF ZG-AF108 Crank arm adaptor kit for AF/NF ZS-100 Weather shield (metal) ZS-150 Weather shield (polycarbonate) ZS-300 NEMA 4X housing 965-00001 1mm form fit square shaft adaptor For an overview of how to apply the accessories, see Belimo Mechanical Accessories and refer to the Belimo Mounting Methods Guide. NOTE: When using FSAFxx (-S) US actuators, only use accessories listed on this page. Wiring Diagrams 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuator may also be powered by 4 VDC. 4 No ground connection required. Double insulated. 5 For end position indication, interlock control, fan startup, etc., the FSAF30-S US incorporates two built-in auxiliary switches: x SPST, 7A resistive,.5 inductive @10/50 VAC, UL Approved, one switch is fi xed at 10, one is adjustable from 30 to 90. Meets UL requirements without the need of an electrical ground connection. Meets culus or UL and CSA Standard requirements without the need of an electrical ground connection. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Typical Specification Large combination fi re and smoke dampers are to be operated by Belimo FSAF series actuators. Manufacturer shall provide 5 year warranty. Actuators shall draw no more than 1VA at 30V or 10 VA at 4V. Where auxiliary switches are required for signaling, starting fans, or position indication, -S model actuators, damper blade, or proximity switches shall be provided. Smaller dampers shall employ Belimo FSLF or FSNF actuators per damper manufacturer recommendations. FSAF4 US and FSAF30 US W439_08 174

FSAF4-SR(-S) US Proportional, Spring Return, 4 V, to 10 VDC or 4 to 0 ma control signal Operation at 50 F for limited time per UL555S testing Torque min. 133 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection FSAF4-SR FSAF4-SR(-S) US 4 VAC ± 0% 50/60 Hz 4 VDC ± 10% running 7 W, 11 VA holding 3 W, 5 VA 15 VA (class power source) 3 ft, 18 GA, 4 color coded leads (4V) 1/ conduit connector FSAF4-SR-S 3 ft, 18 GA appliance cable 1/ conduit connector Overload protection electronic throughout 0 to 95 rotation Operating range to 10 VDC, 4 to 0mA Input impedance 100 kω (0.1 ma), 500 Ω Feedback output U to 10 VDC (max. 0.5 ma) for 95 Angle of rotation mechanically limited to 95 Torque 133 in-lb [15 Nm] constant Direction of rotation spring reversible with cw/ccw mounting The control direction switch is not present. Direct acting only. VDC=Fail-safe position. Position indication visual indicator, 0 to 95 (0 spring return position) Manual override 3mm hex crank (shipped w/actuator) Running time motor <75 sec. constant, independent of load spring < 0 seconds Humidity 5 to 95% RH non-condensing Ambient temperature normal duty - F to 1 F [-30 C to 50 C] safety duty 3 on/off cycles after 30 minutes at ambient temperature of 50 F [11 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEMA type / IP40 Housing material zinc coated metal Agency listings culus to UL873 and CSA C. No. 4-93 Noise level (max) running 45 db (A) Servicing maintenance free Quality standard ISO 9001, 5 year Belimo warranty Weight 6.0 lbs (.7 kg.) Application For proportional modulation of UL555S rated dampers in HVAC. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft or jackshaft up to 1.05 in diameter by means of its universal clamp. A crank arm and mounting brackets are available if the actuator cannot be direct coupled to the jackshaft or damper shaft. The actuator operates in response to a to 10 VDC, or with the addition of a 500 Ω resistor, a 4 to 0 ma control input from an electronic controller or positioner. A to 10 VDC feedback signal is provided for position indication or master-slave applications. See Application Bulletin for details. Operation The FSAF series actuators provide spring return operation. There is no reversing switch on the FSAF4-SR. It is direct acting only. A reverse acting signal is required if it must spring open while V signal drives it closed. The torque is asymmetrical giving 180 in-lb drive and 133 in-lb spring. The FSAF resets after being driven or springing closed to the 0 position. There is a possible hysteresis of 1 every 1000 changes in signal. This can cause a position shift. It is recommended that power or signal be reset once a week. A manual override winder and locking mechanism is provided. If the manual winder is used when the actuator is powered, the actuator will release and drive closed to reset the 0 degree position. The actuator may not be mechanically parallelled or piggybacked. Each damper section should be controlled by a separate actuator. The wire 5 feedback can be used to parallel up to five additional actuators. If less than.1 V or greater than 9.9V is given wire 3, actuator drives all the way to the respective end stop. The FSAF uses a DC motor which is controlled by a microchip The actuator may be stalled anywhere during its rotation without damage. If power is removed, the damper will spring closed. Interlocks must be provided as necessary for life safety functions and to shut down fan if required. SAFETY NOTE Screw a conduit fi tting into the actuator s bushing. Jacket the actuator s input and output wiring with suitable fl exible conduit. Properly terminate the conduit in a suitable junction box. Dimensions (Inches [mm]) Standard: 1/" to 1.05" Optional* 3/8" to 3/4" *with K4 US clamp 0.65" [16.5] 3.86" [98] 3.10" [78] 3.15" [80].4" [57] 0.19" [5] 0.39" [10] 0.35" [9].64" [67] 10.59" [69] 5.85" [148.5] 0.6" [6.5] 1.93" [49] D001(old) FSAF4-SR-S US x SPDT 7A resistive,.5a inductive at 10/50VAC. UL Approved, double-insulated, one set at =+10, one adjustable 30 to 90 1.97" [50] 175

FSAF4-SR(-S) US Proportional, Spring Return, 4 V, to 10 VDC or 4 to 0 ma control signal Operation at 50 F for limited time per UL555S testing Accessories (AF series accessories may be employed) IND-AF Damper position indicator K4 US Universal clamp for 3/8 to 3/4 shafts K4-1 US Universal clamp for up to 1.05 dia. jackshafts K4-H Universal clamp for hexshafts 3/8 to 5/8 KH-AF Crank arm for up to 3/4 round shaft (Series ) KH-AF-1 Crank arm for up to 1.05 jackshaft (Series ) KH-AFV V-bolt kit for KH-AF and KH-AF-1 Tool-01 10 mm wrench SGA4 Min. and/or max. positioner in NEMA 4 housing SGF4 Min. and/or max. positioner for flush panel mounting ZG-R01 500 Ω resistor for 0 to 0 ma control signal ZDB-AF US Angle of rotation limiter ZG-100 Universal mounting bracket ZG-101 Universal mounting bracket ZG-10 Multiple actuator mounting bracket ZG-103 Universal mounting bracket ZG-104 Universal mounting bracket ZG-106 Mounting bracket for Honeywell Mod IV replacement or new ZG-107 Mounting bracket for Honeywell Mod III or Johnson Series 100 replacement or new ZG-108 Mounting bracket for Barber Colman MA 3../4.., Honeywell Mod III or IV or Johnson Series 100 replacement or new ZG-AF Crank arm adaptor kit for AF/NF ZG-AF108 Crank arm adaptor kit for AF/NF ZS-100 Weather shield (metal) ZS-150 Weather shield (polycarbonate) ZS-60 Explosion-proof housing ZS-300 NEMA 4X housing For an overview of how to apply the accessories, see Belimo Mechanical Accessories and refer to the Belimo Mounting Methods Guide. NOTE: When using FSAF4-SR(-S) US actuators, only use accessories listed on this page. 4 No ground connection required. Double insulated. 5 Only connect common to neg. ( ) leg of control circuits. 6 For end position indication, interlock control, fan startup, etc., FSAF4-SR-S US incorporates two built-in auxiliary switches: x SPDT, 7A resistive,.5a inductive 10/50 VAC, UL Approved, one switch is fi xed at 10, one is adjustable 30 to 90. Meets UL requirements without the need of an electrical ground connection. The ZG-R01 500 Ω resistor converts the 4 to 0 ma control signal to to 10 VDC. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. W188_08 Typical Specification Proportional smoke, and combination fi re and smoke dampers, shall be controlled by Belimo FSAF4-SR actuators. The control signal shall provide proportional damper control in response to a to 10 VDC or, with the addition of a 500 Ω resistor, a 4 to 0 ma control input from an electronic controller or positioner. The actuators must be designed so that they may be used for either clockwise or counter clockwise fail-safe operation. Actuator shall open damper in <75 seconds per UL555S and shall spring closed in under 0 seconds. Actuators shall be UL Approved, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. Actuators with auxiliary switches must be constructed to meet the requirement for double insulation so an electrical ground connection is not required to meet agency listings. Replacement Application The number one equal or better requirement for use as a replacement for obsolete defective motors is the UL555S listing of the Belimo actuator with the damper for the application. The local authority having jurisdiction sets the requirements since UL has stated that they do not regulate replacements. Wiring Diagrams Proportional control W57_08 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuator may also be powered by 4 VDC. 176

FSAF4-BAL(-S) US Spring Return, 4 V, 3-Position, 100% Open Override Operation at 50 F for limited time per UL555S testing Technical Data Power supply FSAF4-BAL(-S) US 4 VAC ± 0% 50/60 Hz 4 VDC ± 10% Power consumption running AC 9.5 VA 6.5W DC 6W holding AC 5 VA 3W DC 3W Transformer sizing 10 VA (class power source 4V only) Electrical connection 3 ft, 18 GA, 1/ conduit connector Overload protection electronic throughout 0 to 95 rotation Control signal 4 VAC/DC 3-position Angle of rotation 0 to 95, pot adjustable Torque 133 in-lb [15 Nm] Direction of rotation spring reversible with cw/ccw mounting Position indication visual indicator, 0 to 95 (0 spring return position) Manual override 3mm hex crank (shipped w/actuator) Running time motor <75 seconds @ 50 F [11 C] spring < 0 seconds Humidity 5 to 95% RH non-condensing Ambient temperature - F to 1 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEMA type 1/IP40 (with flex conduit) Housing material zinc coated metal Agency listings culus to UL873 and CSA C. No. 4-93 Noise level (max) running <45 db(a) spring <6dB(A) Servicing maintenance free Quality standard ISO 9001, 5 year Belimo warranty Weight 5.3 lbs (.4 kg) 5.7 lbs (.6 kg) for -S model FSAF4-BAL-S US x SPDT 7A resistive,.5a inductive at 10/50VAC. UL listed, double-insulated, one switch is set at 10, one is adjustable 30 to 90 Application For 3-position control of UL555S rated dampers in HVAC. Actuator sizing should be done in accordance with the damper manufacturer s tests. In the absence of other information, use 10 in-lb of torque per square foot of area for opposed blade and 14 in-lb for parallel blade fire and smoke dampers at 1000 fpm air velocity. The FSAF4-BAL is specifically designed to balance the air flow in ducts and simultaneously provide control of fire and smoke dampers. 0V = spring closed. 4V on wire, not 3 = drive to the potentiometer position (balanced flow). 4V on wire 3, regardless of the status of wire = drive full open (smoke control extraction or pressurization). See Application Bulletin for details. Operation For 3-position control of UL555S rated dampers in HVAC. Actuator sizing should be done in accordance with the damper manufacturer s tests. In the absence of other information, use 10 in-lb of torque per square foot of area for opposed blade and 14 in-lb for parallel blade fire and smoke dampers at 1000 fpm air velocity. The FSAF4-BAL is specifically designed to balance the air flow in ducts and simultaneously provide control of fire and smoke dampers. 0V = spring closed. 4V on wire, not 3 = drive to the potentiometer position (balanced flow). 4V on wire 3, regardless of the status of wire = drive full open (smoke control extraction or pressurization). SAFETY NOTE The actuator contains no components which the user can replace or repair. Dimensions (Inches [mm]) Standard Optional ½ to 1.05 ½ 0.65" [16.5] 3.5" [8.7].4" [57] 0.39" [10] 0.35" [9] 3.86" [98] 0.19" [5] 3.15" [80].64" [67] 1.97" [50] 10.59" [69] 5.85" [148.5] 0.6" [6.5] 1.93" [49] 70793-00001.pdf 177

FSAF4-BAL(-S) US Spring Return, 4 V, 3-Position, 100% Open Override Operation at 50 F for limited time per UL555S testing Accessories (AF series accessories may be employed) IND-AF Damper position indicator K4-1 US Universal clamp for up to 1.05 dia. jackshafts KH-AF Crank arm for up to 3/4 round shaft (Series ) KH-AF-1 Crank arm for up to 1.05 jackshaft (Series ) KH-AFV V-bolt kit for KH-AF and KH-AF-1 Tool-01 10 mm wrench ZDB-AF Angle of rotation limiter ZG-100 Universal mounting bracket ZG-101 Universal mounting bracket ZG-103 Universal mounting bracket ZG-104 Universal mounting bracket ZG-106 Mounting bracket for Honeywell Mod IV replacement or new ZG-107 Mounting bracket for Honeywell Mod III or Johnson Series 100 replacement or new ZG-108 Mounting bracket for Barber Colman MA 3../4.., Honeywell Mod III or IV or Johnson Series 100 replacement or new ZG-AF Crank arm adaptor kit for AF/NF ZG-AF108 Crank arm adaptor kit for AF/NF ZS-100 Weather shield (metal) ZS-150 Weather shield (polycarbonate) ZS-300 NEMA 4X housing 965-00001 1 mm form fit square shaft adaptor For an overview of how to apply the accessories, see Belimo Mechanical Accessories and refer to the Belimo Mounting Methods Guide. NOTE: When using FSAF4-BAL(-S) US actuators, only use accessories listed on this page. Typical Specification Where indicated on drawings, combination fi re and smoke and balancing dampers shall be controlled by Belimo FSAF4-BAL or equal actuators. The actuators must be designed so that they may be used for either clockwise or counter clockwise failsafe operation. Actuator shall open damper in <75 seconds per UL555S and shall spring closed in under 0 seconds. Actuators shall have a 5-year warranty and be manufactured under ISO9001 International Quality Control Standards. Actuator shall have an adjustable Maximum Opening Potentiometer which shall be used by the TAB contractor to adjust fl ow to that portion of the system fed by the damper. The actuator shall spring closed if either the smoke detector or alarm system removes power from it. Actuator shall spring closed if the primary temperature thermodisc opens due to high ambient of >165 F or as otherwise indicted on drawings. The actuator shall drive full open if either the smoke control system 100% open override or Fire Fighters Smoke Control Station override is activated. Damper shall spring closed again if the thermodisc of a combination fi re and smoke damper opens due to high temperature (typically 50 F). Wiring Diagrams 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuator may also be powered by 4 VDC. 4 Only connect Hot, Wire to Wire 3 override control 5 6 6 For end position, interlock control, fan start-up, etc., FSAF4-BAL-S incorporates two built-in auxiliary switches: x SPDT, 7A resistive,.5a inductive 10/50 VAC, UL listed, one switch is fi xed at 10, one adjustable 30 to 90 For end position indication, interlock control, fan startup, etc., FSAF4-SR-S US incorporates two built-in auxiliary switches: x SPDT, 7A resistive,.5a inductive 10/50 VAC, UL Approved, one switch is fi xed at 10, one is adjustable 30 to 90. Meets UL requirements without the need of an electrical ground connection. 7 Double insulated WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 1 Line Volts Override control 4 VAC Transformer 4 OVERRIDE CONTROL See Wiring Diagrams on following pages for typical methods. S1 NC S S3 NO S4 NC S5 S6 NO 1 Blk Com Red Hot 3 3 Override Open 6 FSAF4-BAL US 10 30 to 90 FSAF4-BAL-S US 5 7 70793-00001_pg 70793-00001_pg 178