Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Contents Application, Requirements Application, Requirements Features Designs, typical application Technical Data, Shipping Electrical data, temperature, filling pressure 4 Switchgear installation, transport data 4 Product Range Product range overview, schemes 5 Equipment features 5 Design Panel design 6 Components Three-position switch-disconnector 7 Operating mechanisms 7 HV HRC fuse assembly 8 Secondary equipment 8 Cable connection 9 Dimensions Switchgear, floor openings, fixing points 0 Sections, pressure absorber system and Cable connection examples Standards Standards, specifications, guidelines Classification 4 Notes Further Information See Catalog HA 40. Invalid: Catalog HA 45. 00 5 Page The products and systems described in this catalog are manufactured and sold according to a certified quality and environmental management system (acc. to ISO 900 and ISO 400). (DQS Certificate Reg. No. DQS 0047 QM UM). The certificate is accepted in all IQNet countries. Features 8DJ0 switchgear is a factoryassembled, type-tested, metalenclosed switchgear for indoor installation. Typical uses 8DJ0 switchgear is used for power distribution in substations even under severe environmental conditions, such as: Industrial environments Damp, sandy or dusty areas Simple outdoor substations Main uses Compact substations Compact transformer substations, e.g.forwindpowerstations Garage and vault substations Underground and underfloor substations Sidewalk substations, e.g. containing switchgear with a very small overall width in particular the basic versions of schemes 0 and 7in conurbations Substations with control aisle Technology Switchgear design with up to 6 Maintenance-free Climate-independent Partition class: PM (partition of metal) Three-pole primary enclosure, metal-enclosed Insulating gas SF 6 Welded switchgear vessel without seals, made of stainless steel, with welded-in bushings for electrical connections and mechanical components Three-position switch-disconnector with load-break and make-proof earthing function Cable connection for bushings with outside cone Connection with cable plugs Inring-mainwithbolted contact (M6) In transformer with plug-in contact Option: Connection with conventional sealing ends For thermoplastic-insulated cables via elbow adapter AKE 0/0 (make Siemens) For paper-insulated mass-impregnated cables via commercially available adapter systems Easy installation Personal safety Safe-to-touch and hermetically sealed primary enclosure HV HRC fuses and cable sealing ends are only accessible when outgoing are earthed Operation only possible when enclosure is closed Logical mechanical interlocking Capacitive voltage detecting system to verify safe isolation from supply Feeder earthing by means of make-proof earthing switches Security of operation Hermetically sealed primary enclosure, independent of environmental effects such as pollution, humidity and small animals, sealed for life: Welded switchgear vessel Welded-in bushings and operating mechanism Operating mechanism parts maintenance-free (IEC 60 694/ VDE 0670-000) Operating mechanisms of switching devices located outside the switchgear vessel Switchgear interlocking system with logical mechanical interlocks Cost-efficiency Extremely low life-cycle costs throughout the entire product service life thanks to: Maintenance-free concept Climatic independence Minimum space requirement Maximum availability Standards see page SiemensAG007 Siemens HA 45. 007
R-HA45-c eps R-HA45-9b eps R-HA45-0b eps R-HA45-b eps Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Application Designs, typical application Our product range comprises switchgear consisting of Ring-main Transformer with HV HRC fuse assemblies The switchgear is available in two overall heights: 60 mm (with low subframe) 6 mm (with high subframe) These overall heights cover all areas of application, from compact substations to switchgear rooms with control aisle Basic design Transformer cable connection in upper area With logical mechanical interlocks With ready-for-service indicator ring-main transformer feeder Scheme 0 Ring-main/transformer blocks ring-main transformer feeder Scheme 7 4 ring-main transformer Scheme 6 With capacitive voltage detecting system at the ring-main Options Capacitive voltage detecting system at the transformer Motor operating mechanisms for the three-position switchdisconnectors of the ringmain and transformer Auxiliary switch for threeposition switch-disconnector and make-proof earthing switch Short-circuit indicator with flush-mounted housing for ring-main Surge arresters for ring-main Shunt releases for transformer Secondary equipment for remote operation or remote indication, e.g. with localremote switch in the case of motor operating mechanisms or tripping signal in the case of transformer Locking devices Closing lock-out Mounted cable clamps at the ring-main Further options on request 8DJ0 switchgear in substation with control aisle Siemens HA 45. 007
Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Technical Data, Shipping Electrical data, temperature, filling pressure Electrical data Switchgear installation, transport data Switchgear installation Rated voltage U r kv 7. 5 7.5 4 Rated insulation level: Rated short-duration power kv 0 8 ) 6 8 frequency withstand volt. U d Rated lightning impulse kv 60 75 ) 95 95 5 withstand voltage U p Rated frequency f r Rated normal current I r for ring-main for transformer depending on the HV HRC fuse link Rated short-time withstand current I k,s /60 Hz 400 A or 0 A 00 A 0 5 0 5 0 5 6 0 5 6 0 700 700 HA45-8b eps 7 4 5 6 Wall-standing arrangement Direction of pressure relief Overall height 60 mm Downwards Overall height 6 mm Downwards To the rear (on request) Rated short-time withstand current I k, s (option) Rated peak withstand current I p 0 0 0 0 0 40 40 Rated short-circuit making current I ma fortransformer 5 5 5 5 5 for ring-main 40 40 Switchgear Floor opening into cable duct Expanded metal (not included in the scope of supply) 4 Direction of pressure relief 5 Cable 6 Sheet-metal partition (not included in the scope of supply) 7 Wall distance Temperature, filling pressure Ambient air temperature T (operating conditions acc. to IEC 6 7-00, Clause or IEC 60 694) Without secondary equipment 40to+70C ) With secondary equipment, Class Minus5indoor 5to+55C ) Pressure values at 0 C for the insulation: Rated filling level p re Minimum functional level p me 0 hpa (absolute) 00 hpa (absolute) Transport data Scheme No. Version (abbreviations) Switchgear height Transport dimensions Width Height Depth Volume Gross weight ) approx. kg mm m m m m Transport within Europe by rail, truck, container Packing with PE protective foil and wooden base 0 RK+T 60.0.56.0.89 00 6.0.85.0.4 0 7 RK+T 60.45.56.0.49 80 6.45.85.0.95 40 6 4RK+T 60.80.56.0.09 580 6.80.85.0.66 660 Transport overseas by seafreight Packing with PE protective foil and seaworthy crate 0 RK+T 60.0.0.5.5 6.0.0.5.5 80 7 RK+T 60.45.0.5.4 460 6.45.0.5.4 6 4RK+T 60.80.0.5 4.4 680 6.80.0.5 4.4 760 ) Option: For a rated short-time withstand current I k =0/sor I k =0/s,U d =4kVandU p =95kVarepossibleaccordingtosome national requirements ) Temperature range, reduced normal currents at ambient air temperatures >+40C ) Weight depending on the relevant equipment, e.g. motor operating mechanism Abbreviations: RK = Ring-main feeder T = Transformer feeder 4 Siemens HA 45. 007
Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Product Range Product range overview, schemes Scheme Overall dimensions Net weight Width mm Depth mm Height mm ) approx.kg Block types, consisting of ring-main and transformer Scheme 0 5 ) HA45-4a eps T ring-main and transformer feeder (Abbreviations RK+T) 70 775 60 6 70 00 Equipment features of panels Equipment Manual operating mechanism for three-position switch-disconnector: As spring-operated mechanism As spring-operat./stored-energy mech. Motor operating mechanism for three-position switch-disconnector Basic equipment Additional equipment (option), further additional equipment on request x Not applicable Not available Ring-main RK panels Transformer Tpanels Interlock of cable compartment cover for ring-main x RK RK Interlock of HV HRC fuse compartment and transformer cable compartment x Cable bracket ) in ring-main, cable routing downwards x Scheme 7 5 ) HA45-5b eps T ring-main and transformer feeder (Abbreviations RK+T) 060 775 60 6 40 90 Cable connection in transformer feeder (cable fixing by customer, supplied without cable bracket) for cable routing To the rear (standard) forcableelbowplugsor Upwards for straight cable plugs or Totheright forcableelbowplugs x x x or or ) Low-voltage terminals in the operating mechanism (option for secondary equipment) RK RK RK Scheme 6 6 ) 5 ) HA45-6b eps T T 4 ring-main and transformer (Abbreviations 4RK+T) 40 775 60 6 0 580 Shunt release Auxiliary switch for Switch-disconnector CLOSED/OPEN: NO+NC EARTHINGCLOSED/OPEN: NO+NC Locking device for three-position switch-disconnector Short-circuit or earth-fault indicator Wiring at the indicator (standard) Wiring to terminal (option) RK RK RK RK ) Weight depending on the relevant equipment, e.g. motor operating mechanism 5) Cable routing optionally: To the rear (standard) Upwards (option) To the right (option): Additional distance of 0 mm required for cable routing/cover 6) Cable routing optionally: To the rear (standard) Upwards (option) Abbreviations for both tables: RK = Ring-main feeder T = Transformer feeder Closing lock-out for three-position switch-disconnector Double cable connection for Overall height of switchgear 60 mm Overall height of switchgear 6 mm x x Surge arrester for Overall height of switchgear 60 mm Overall height of switchgear 6 mm 4) Mounted cable clamps ) For overall height of switchgear 60 mm: Cable bracket below the feeder ) For scheme 6 only possible for the right-hand feeder 4) Only possible for 05 mm deeper cable compartment cover and 00 mm deeper cable compartment cover Surge arrester: Type RDA with RICS (Raychem) not possible for 60 mm x x x Siemens HA 45. 007 5
Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Design Panel design (example) Ring-main/transformer block A B Transformer feeder Section A-A Ring-main feeder Section B-B 7 8 4 4 9 5 5 4 0 6 7 8 9 0 L L L 5 6 6 0 9 8 0 0 6 HA45-48c eps HA45-49b eps 7 9 HA45-b eps Scheme 0 B A Standard Cable connection for cable elbow plugs with plug-in contact, cable routing to the rear Cable connection with bolted contact (M6) optionally for: Cable T-plugs or cable elbow plugs Elbow adapter AKE 0/0 (make Siemens) for conventional cable sealing ends Feeder designation label Sockets for voltage detecting system Ready-for-service indicator 4 Switch position indicator for earthing function OPEN EARTHED 5 Switch position indicator for load-break function CLOSED OPEN 6 Locking device (option for threeposition switchdisconnector) 7 Manual operation for the mechanism of the earthing function 8 Manual operation for the mechanism of the load-break function 9 Short-circuit/earth-fault indicator (option) 0 Interlock of the cable compartment cover Personal safety All feeder-related covers can only be opened if the associated three-position switch-disconnector has been switched to the EARTHED position. 7 8 7 8 Option Cable connection for straight cable plugs with plug-in contact, cable routing upwards Option (only for schemes 0 and 7) Cable connection for cable elbow plugs with plug-in contact, cable routing to the right Design options for the transformer cable connection, see table on page 9 (cable fixing always by customer) HV HRC fuse assembly, cover removed Interlock for HV HRC fuse assembly Mimic diagram for transformer feeder 4 Rating and type plate 5 Mimic diagram for ring-main feeder 6 Arrangement of cable connections 7 Cable elbow plug with plug-in contact 8 Bushing as interface type A for cable plugs with plug-in contact 9 Connecting bar to cable connection 0 Three-position switch-disconnector Switchgear vessel, filled with gas Cable compartment Straight cable plug with plug-in contact 4 Cover of the HV HRC fuse compartment and of the transformer cable compartment 5 Spring-operated/stored-energy mechanism 6 Cable compartment cover 7 M earthing connection 8 Pressure relief device 9 Cable bracket in ring-main feeder 0 Spring-operated mechanism Bushing as interface type C for cable plugs with bolted contact (M6) Elbow adapter AKE 0/0 for conventional cable sealing end (bolted contact M6) Cover in transformer feeder for cable routing to the right 6 Siemens HA 45. 007
R-HA45-06a eps R-HA45-07 eps R-HA45-04 eps R-HA45-05 eps R-HA45-4a eps R-HA45- eps Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Components Three-position switch-disconnector, operating mechanisms Three-position switch-disconnector The switching device used is the proven three-position switch-disconnector. Functions Load-break function Earthing function with shortcircuit making capacity Switch positions CLOSED OPEN EARTHED Three-position switch-disconnector Three-position switch-disconnector Rear view into the switchgear vessel of a ring-main/transformer block, scheme 0 Three-position switch-disconnector in the transformer feeder Three-position switch-disconnector in the ring-main Pressure relief device Operating mechanisms The three-position switchdisconnector is operated from the switchgear front via Detachable lever mechanism Spring-operated mechanism With spring-operated CLOSED and spring-operated OPEN for installation in ring-main Spring-operated/storedenergy mechanism With spring-operated CLOSED and spring-operated OPEN for installation in transformer With an additional energy store for the function stored-energy OPEN after tripping by the HV HRC fuse (striker pin tripping) or by the shunt release Options Motor operating mechanism for switch-disconnector Locking devices Auxiliary switch for threeposition switch-disconnector and make-proof earthing switch Shunt release for transformer Closing lock-out for ring-main Different operating levers ) for the operating mechanisms of the switch-disconnector and the make-proof earthing switch ) According to VDN */VDEW** recommendation * AssociationofGermanNetwork Operators VDN e.v. at the VDEW in Germany (as of 00) ** Association of German Power Stations VDEW e.v. Operating mechanisms 7 9 0 4 5 6 8 Control board for detachable lever mechanisms (standard) Example: Ring-main/transformer block, scheme 0 4 Locking device (option) for the detachable lever mechanism 5 Detachable lever mechanism for the earthing function 6 Detachable lever mechanism for the load-break function 7 Detachable lever mechanism for the ring-main feeder 8 Detachable lever mechanism for the transformer feeder On request: Control board for rotary operating mechanisms Example: Ring-main feeder 9 Symbols for the actuating direction of the rotary operating mechanism 0 Locking device for the rotary operating mechanism Rotary operating mechanism Siemens HA 45. 007 7
R-HA45-eps R-HA45-9a eps Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Components HV HRC fuse assembly, secondary equipment HV HRC fuse assembly The HV HRC fuse boxes are single-phase insulated and located above the transformer feeder outside the switchgear vessel. Standards (see page ) HV HRC fuse links with striker pinin medium version according to IEC 60 8- VDE 0670 Parts 4 and 40 DIN 4 65 main dimensions HV HRC fuse compartment L L L HV HRC fuse compartment with cable compartment cover removed Phase L: HV HRC fuse box with HV HRC fuse slide removed Phase L: HV HRC fuse box closed Phase L: Replacement of HV HRC fuses Features Access to the HV HRC fuse compartment and replacement of HV HRC fuses is only possible if the transformer feeder has been isolated and earthed Requirements fulfilled as HV alternating current switch fuse combination Selection of HV HRC fuses for transformers Thermalprotectionsystem; it protects the switchgear against the effects of an incorrectly inserted fuse link Thermal striker tripping when using an appropriate HV HRC fuse link, e.g. make Siemens, type GD HV HRC fuses are easy to replace Secondary equipment (option) Auxiliary switch, motor operating mechanism and shunt release Operating mechanism components at the spring-operated/stored-energy mechanism of a transformer feeder: Motor operating mechanism Auxiliary switch Terminal strip 4 Shunt release Secondary equipment (option) 4 Examples: Auxiliary switches Motor operating mechanisms Shunt releases Wiring Auxiliary switches, motor operating mechanisms or shunt releases are wired to terminal strips. These are feeder related and located next to the operating mechanism module of the feeder concerned. Customer-side cable routing is done from the side, if required from the rear to the terminal strip arranged at the operating mechanism module. 8 Siemens HA 45. 007
R-HA45-0 eps R-HA45- eps R-HA45- eps R-HA45-8 eps Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Components Cable connection Bushings according to EN8/DINEN8 ) with outside cone Access to the cable compartment only if the feeder has been isolated and earthed Ring-main connection With bolted contact (M6) as interface type C according to EN8/DINEN8 Cable connection at one level For thermoplastic-insulated cables For paper-insulated massimpregnated cables with adapter systems For conventional cable sealing ends via elbow adapters AKE 0/0 (make Siemens) ForcableT-plugsorcable elbow plugs with bolted contact For connection cross-sections up to 00 mm (standard) Cable routing downwards, cable connection at front For rated normal currents of 400 A or 0 A Options Suitable for the connection of surge arresters Short-circuit/earth-fault indicator Mounted cable clamps Double cable connection with corresponding cable plugs Transformer cable connection With plug-in contact as interface type A according to EN8/DINEN8 For thermoplastic-insulated cables For cable elbow plugs (standard) or straight cable plugs with plug-in contact For connection cross-sections up to 0 mm For rated normal currents of 00 A Option Cable routing upwards or to the right 5 Cable connection (examples) L L L L L L Cable compartment, as delivered (front view) Cable connection, as delivered (side view) ) Standard EN 8/DIN EN 8: Plug-in bushings above kvupto6kvandfromato.5 for equipment other than liquid-filled transformers. 6 4 Cable plugs with bolted contact (M6) L L L L L L Cable elbow plug with cable routing to the rear Transformer cable connection for cable plugs with plug-in contact as interface type A Arrangement of connections In upper area, beside the HV HRC fuse assembly 7 8 Cable routing To the rear (standard) To the right (option) (observe lateral distance of 0 mm) Upwards (option) Cable plug version Cable elbow plug with plug-in contact for all schemes Cable connections in ring-main feeder Prepared for cable plugs with bolted contact (M6) Phase L: Make: Euromold, type K400 LB as cable elbow plug Phase L: Make: Euromold, type K400 TB as cable T-plug 4 Phase L: Make: Euromold, type AGT 0/0 as cable T-plug Option: Mounted cable clamps Cable connections in transformer feeder 5 Prepared for cable plugs with plug-in contact 6 Phase L: Make: Euromold, type K58 LR 7 Phase L: Make: nkt cables, type EASW 0/ 8 Phase L: Make: Cooper, type DE -R-C Cable routing to the rear, cable fixing by customer Cable elbow plug with plug-in contact For schemes 0 and 7 For scheme 6: Only possible for the right-hand transformer feeder Straight cable plug with plug-in contact for all schemes Cable plugs, cable sealing ends and cable clamps are not included in the scope of supply. Siemens HA 45. 007 9
Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Dimensions Switchgear, floor openings (dimensions in red) and fixing points Block versions, consisting of ring-main and transformer optionally in overall heights Overall height of switchgear 60 mm There are recesses available on the switchgear side. The recesses provided in the floor opening for cable plugs and, if applicable, surge arresters have to be observed by the customer, depending on the make and type of the cable plug / surge arrester. For sections A-A and B-B see page. HA45-55d eps 70 B TR A 7 HA45-56e eps 060 B TR A HA45-57e eps 40 B A TR TR 6 60 6 60 6 60 RK RK RK RK RK RK RK RK RK A B A B A B ³5 47 97 47 44 5 65 700 75 0 0 5 0 0 5 5 55 6 55 7 60 5 6 5 ³5 0 ³5 (³ ) 400 7 9 40 06 00 8 x 4 4 x 8 60 Floor openings and fixing points Scheme 0 40 970 For missing dimensions seescheme0 Floor openings and fixing points Scheme 7 40 0 For missing dimensions seescheme0 Floor openings and fixing points Scheme 6 Wall distance Fixing points Position of the incoming cables in the ring-main feeder 5 Floor opening for high-voltage cables 6 Fixing frame (base) of the switchgear 7 For cable routing for transformer feeder T: 0 mm required additionally to the switchgear width BB Wall distance for scheme 6: Standard: 5 mm Optional design according to IEC 6 7-00 with internal arc classification IAC A FL: mm 0 Siemens HA 45. 007
Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Dimensions Sections, pressure absorber system Sections of the block versions from page 0 Section A-A Section B-B Wall distance 4 Position of the incoming cables in the ring-main feeder 4 Position of the incoming cables to the rear in the transformer feeder (standard) HA45-58f eps 55 ~560* 7 775 Ring-main feeder RK 40 85** ** HA45-59f eps 455*** 65*** 60 60 Transformer feeder T 40 60 M Plan view * Depending on the type of cable plug ** Dimensions depending on the overall heights of the switchgear 60 and 6 mm *** Dimensions depending on the overall heights of the switchgear 60 and 6 mm, slight deviations are possible due to the various makes of cable elbow plugs B Dimension for bushing as interface type C with bolted contact (M6) The cables and cable plugs shown here are not included in the scope of supply. 6 60 60 400 ~ ³5 Pressure absorber system (option) ~560 45 775 880 Switchgear arrangement Overall height 6 mm Ring-main feeder RK: Cable routing downwards 40 HA45-409a eps 60 6 4 40 5 455 60 60 ~560 HA45-40a eps Transformer feeder T: Cable routing to the right * Additionally 0 mm for cable routing/cover to the right 0*) 60 M 40 Plan view Pressure absorber system (option) Maintenance-free For all schemes For rated short-time withstand current I k 6, with IAC (internal arc classification, see page 4) With 05 mm deep pressure reliefductforpressure relief directed upwards Foroverallheightofswitchgear6mm For wall-standing arrangement Cable routing in transformer feeder (T), seepage Weight approx. 0 kg Sections of the pressure absorber system Wall distance Pressure absorber system with rear pressure relief duct, relief directed upwards Cable bushing 4 Divided floor cover for cable entry for local installation 5 Floor opening for the cable feeder 6 Bushing for transformer feeder Siemens HA 45. 007
Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Dimensions Pressure absorber system (option) Cable connection examples in ring-main Examples for an overall height of 6 mm (Continued from page ) Routing of transformer cables Scheme 0, 7 Upwards ) To the rear ) Totheright ) HA45-80a eps Single cable connection Elbow adapter, make: Siemens, type AKE 0/0 with conventional cable sealing end, make: Lovink, type IAE 0 Cable T-plug, make: Euromold, type (K) 400 TB/TBS Routing of the st transformer cable (left) 55 Scheme 6 Upwards ) To the rear ) Routing of the nd transformer cable (right) Scheme 6 Upwards ) To the rear ) Totheright ) ) For straight cable plugs ) For cable elbow plugs HA45-8a eps ~560 60** 7 775 Standard cable compartment cover 55 ~560 60** 7 775 Standard cable compartment cover Cable connection with surge arresters Cable plug, make: Tyco Electronics Raychem, type RICS 59 4 Surge arrester ),typesuptordaorrda4 5 Cable plug, make: nkt cables, type CB 4-0 6 Surge arrester, make: nkt cables, type CSA 4-5 7 Cable plug, make: Euromold, type (K) 400 TB/TBS 8 Surge arrester, e.g. make: Euromold, type 400 Pb or similar types 5 7 ~560 a** 7 775 Standard cable compartment cover 4 ~560 60** 7 775 Standard cable compartment cover 6 ~560 60** 897 95 mm deeper cable compartment cover 8 HA45-8a eps Double cable connection 9 Cable T-plug, make: nkt cables, type CB 4-0 and CC 4-0 0 Cable T-plug, make: Südkabel, x type SET (/4) with coupling insert KU. 55 90,5* ~560 0 5** 7 775 Standard cable compartment cover 9 ~560 75** 85 880 ~90 0 05 mm deeper cable compartment cover Footnotes for all dimension drawings * Max. mounting space for cable and/or surge arrester ** Depth of floor opening B Dimension for bushing with bolted contact (M6) ) Make: Tyco Electronics Raychem Dimension a 60 mm up to type RDA 5 mm for type RDA4 Siemens HA 45. 007
Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Standards Standards, specifications, guidelines Overview of standards (May 007) IEC standard VDE standard EN standard Switchgear 8DJ0 IEC 60 694 VDE 0670-000 EN 60 694 IEC 6 7-00 VDE 067-00 EN 6 7-00 Switching devices Circuit-breaker IEC 6 7-00 VDE 067-00 EN 6 7-00 Disconnector and IEC 6 7-0 VDE 067-0 EN 6 7-0 earthing switch Switch-disconnector IEC 60 65- VDE 0670-0 EN 60 65- Switch-disconnector / IEC 6 7-05 VDE 067-05 EN 6 7-05 fuse combination HV HRC fuses IEC 60 8- VDE 0670-4 EN 60 8 Voltage detecting systems IEC 6 4-5 VDE 068-45 EN 6 4-5 Degree of protection IEC 60 59 VDE 0470- EN 60 59 Insulation IEC 60 07 VDE 0 EN 60 07 Instrument tansformers Current transformers IEC 60 044- VDE 044- EN 60 044- Voltage transformers IEC 60 044- VDE 044- EN 60 044- Combined transformer ) IEC 60 044- VDE 044-5 EN 60 044- Installation IEC 6 96- VDE 00 ) Only for switchgear type 8DH0 Standards The 8DJ0 switchgear complies with the relevant standards and specifications applicable at the time of type tests. In accordance with the harmonization agreement reached by the countries of the European Community, their national specifications conform to the IEC standard. Dielectric strength See also Catalog HA 40. Standards. Terms Make-proof earthing switches are earthing switches with short-circuit making capacity according to IEC 6 7-0/ VDE 067-0. Type of service location 8DJ0 switchgear can be used as indoor installations in accordance with IEC 6 96 (Power installations exceeding kv AC) and VDE 00: Outsidelockableelectrical service locations at places which are not accessible to the public. Enclosures of switchgear can only be removed with tools. Inside lockable electrical service locations. A lockable electrical service location is a place outdoors or indoors that is reserved exclusively for housing electrical equipment and which is kept under lock and key. Access is restricted to authorized personnel and persons who have been properly instructed in electrical engineering. Untrained or unskilled persons may only enter under the supervision of authorized personnel or properly instructed persons. Internal arc classification (option) The possibility of faults in gas-insulated switchgear type 8DJ0 is improbable and a mere fraction of that typical of earlier switchgear types, due to: Use of gas-filled switchgear compartments Use of suitable switching devicessuchasthreeposition switches with makeproof earthing switch Logical mechanical interlocks Use of ring-core current transformers (option) Optionally, switchgear type 8DJ0 can be designed with internal arc classification: Internal arc classification IAC Type of accessibility A (for authorized personnel only) Accessible sides SideF (front) SideL (lateral) Onrequest:SideR (rear) Arc test current up to / s, switchgear with pressure absorber: Up to 6/ s Climate and environmental influences 8DJ0 switchgear is completely enclosed and insensitive to climatic influences. Climatic tests fulfilled in accordance with IEC 60 9 (report) All medium-voltage devices (except for HV HRC fuses) are installed in a gas-tight, welded stainless-steel switchgear vessel which is filled with SF 6 gas Live parts outside the switchgear vessel are provided with single-pole enclosure At no point can creepage currents flow from highvoltage potentials to earth Operating mechanism parts which are functionally important are made of corrosionproof materials Bearings in operating mechanisms are designed as drytype bearings and do not require lubrication Suitable instrument transformer designs Siemens HA 45. 007
Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Standards Classification Classification of the 8DJ0 switchgear according to IEC 6 7-00 Design and construction Partition class Loss of service continuity category ) Switchgear WithHVHRCfuses Without HV HRC fuses (RK, T) Accessibility to compartments (enclosure) Busbar compartment Switching-device compartment Cable compartment Switchgear without HV HRC fuses Switchgear with HV HRC fuses (T ) PM (partition of metal) LSC A LSC B Access option Non-accessible Non-accessible Interlock-controlled Interlock-controlled Internal arc classification (option) Designation of internal arc classification IAC Class IAC for Wall-standing arrangement (standard) Type of accessibility A F L Arc test current ) Test duration Ratedvoltage7.kVto4kV IAC A FL, s Switchgear in closed electrical service location, access for authorized personnel only (according to IEC 6 7-00) Front Lateral Up to s ) The loss of service continuity category is always referred to the complete switchgear, i.e. the panel with the lowest category defines the loss of service continuity category of the complete switchgear. ) 8DJ0 switchgear with pressure absorber: Arc test current up to 6, for overall height of switchgear 6 mm. 4 Siemens HA 45. 007
Switchgear Type 8DJ0 up to 4 kv, Gas-Insulated Notes If not stated otherwise on the individual pages of this catalog, we reserve the right to include modifications, especially regarding the stated values, dimensions and weights. Drawings are not binding. All product designations used are trademarks or product names of Siemens AG or other suppliers. If not stated otherwise, all dimensions in this catalog are giveninmm. Responsible for Technical contents: Christoph Maul Siemens AG, Dept. PTD M PPM Erlangen General editing: Gabriele Pollok Siemens AG, Dept. PTD CC M Erlangen Siemens HA 45. 007 5
Siemens AG Power Transmission and Distribution Medium Voltage Division Postfach 40 90 Erlangen Germany www.siemens.com medium-voltage-switchgear For questions concerning Power Transmission and Distribution: You can contact our Customer Support Center 4 hours a day, 65 days a year. Tel.: +49 80/54 70 00 Fax: +49 80/54 4 7 (Calls charged: e.g. 4 ct/min.) E-mail: support.energy@siemens.com www.siemens.com/energy-support Subject to change without notice Order No.: E00-K445-A-A9-7600 Printed in Germany Dispo 606 KG 06.07 6.0 6 En 0 60/800 The information in this document contains general descriptions of the technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract.