ANALYSIS OF POWER EFFICIENCY OF A DIRECT-DRIVEN LOCALLY FABRICATED PERMANENT MAGNET AC GENERATOR FOR SMALL-SCALE WIND POWER APPLICATIONS IN TANZANIA

Similar documents
CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

DOUBLE STATOR WINDING INDUCTION GENERATOR FOR RENEWABLE ENERGY CONVERSION SYSTEMS

Renewable Energy Systems 13

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

A Linear Magnetic-geared Free-piston Generator for Range-extended Electric Vehicles

CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

Department of Electrical and Computer Engineering

Dynamic Behaviour of Asynchronous Generator In Stand-Alone Mode Under Load Perturbation Using MATLAB/SIMULINK

Rotor Position Detection of CPPM Belt Starter Generator with Trapezoidal Back EMF using Six Hall Sensors

Induction Generator: Excitation & Voltage Regulation

Lab Electrical Power Engineering I

Laboratory Experiments for Enhanced Learning of Electromechanical Devices

Converteam: St. Mouty, A. Mirzaïan FEMTO-ST: A. Berthon, D. Depernet, Ch. Espanet, F. Gustin

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1

ESO 210 Introduction to Electrical Engineering

Performance Analysis of Dual Stator Induction Motor

2014 ELECTRICAL TECHNOLOGY

Torque Analysis of Magnetic Spur Gear with Different Configurations

Forced vibration frequency response for a permanent magnetic planetary gear

Advance Electronic Load Controller for Micro Hydro Power Plant

A Comprehensive Study on Speed Control of DC Motor with Field and Armature Control R.Soundara Rajan Dy. General Manager, Bharat Dynamics Limited

LECTURE 19 WIND POWER SYSTEMS. ECE 371 Sustainable Energy Systems

Efficiency Increment on 0.35 mm and 0.50 mm Thicknesses of Non-oriented Steel Sheets for 0.5 Hp Induction Motor

Lesson 16: Asynchronous Generators/Induction Generators

The Wound-Rotor Induction Motor Part I

Statcom Operation for Wind Power Generator with Improved Transient Stability

Lecture 20: Stator Control - Stator Voltage and Frequency Control

Abstract- A system designed for use as an integrated starter- alternator unit in an automobile is presented in this paper. The

Page 1. Design meeting 18/03/2008. By Mohamed KOUJILI

Design of Low Speed Axial Flux Permanent Magnet Generators for Marine Current Application. Sanjida Moury. Supervised by Dr.

Armature Reaction and Saturation Effect

DESIGN OF AXIAL FLUX BRUSHLESS DC MOTOR BASED ON 3D FINITE ELEMENT METHOD FOR UNMANNED ELECTRIC VEHICLE APPLICATIONS

IMPACT OF SKIN EFFECT FOR THE DESIGN OF A SQUIRREL CAGE INDUCTION MOTOR ON ITS STARTING PERFORMANCES

CHAPTER 5 ANALYSIS OF COGGING TORQUE

A starting method of ship electric propulsion permanent magnet synchronous motor

Asynchronous slip-ring motor synchronized with permanent magnets

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

Universal computer aided design for electrical machines

Asian Journal on Energy and Environment ISSN Available online at

Permanent Magnet Machines for Distributed Generation: A Review

Transient Analysis of Offset Stator Double Sided Short Rotor Linear Induction Motor Accelerator

Design and Analysis of Radial Flux Permanent Magnet Brushless DC Motor for Gearless Elevators

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1001 SPECIAL ELECTRICAL MACHINES

Dev Bhoomi Institute Of Technology LABORATORY Department of Electrical And Electronics Engg. Electro-mechanical Energy Conversion II

Real And Reactive Power Saving In Three Phase Induction Machine Using Star-Delta Switching Schemes

Figure1: Kone EcoDisc electric elevator drive [2]

Chapter 5. Design of Control Mechanism of Variable Suspension System. 5.1: Introduction: Objective of the Mechanism:

Models: PMG A and PMG P

A SIMPLIFIED METHOD FOR ENERGIZING THE SOLENOID COIL BASED ON ELECTROMAGNETIC RELAYS

Principles of Doubly-Fed Induction Generators (DFIG)

CHAPTER 5 ACTIVE AND REACTIVE POWER CONTROL OF DOUBLY FED INDUCTION GENERATOR WITH BACK TO BACK CONVERTER USING DIRECT POWER CONTROL

Laboratory Tests, Modeling and the Study of a Small Doubly-Fed Induction Generator (DFIG) in Autonomous and Grid-Connected Scenarios

DHANALAKSHMI COLLEGE OF ENGINEERING MANIMANGALAM. TAMBARAM, CHENNAI B.E. ELECTRICAL AND ELECTRONICS ENGINEERING

Mechatronics Chapter 10 Actuators 10-3

St.MARTIN S ENGINEERING COLLEGE Dhulapally, Secunderabad

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

UNIT 2. INTRODUCTION TO DC GENERATOR (Part 1) OBJECTIVES. General Objective

Optimization of Three-stage Electromagnetic Coil Launcher

This chapter gives details of the design, development, and characterization of the

Research on the Structure of Linear Oscillation Motor and the Corresponding Applications on Piston Type Refrigeration Compressor

Analysis of the Effect of Electric and Magnetic Loadings on the Design Parameters of an Induction Motor and Its Performance Using Matlab/Simulink

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M]

UNIT-1 Drive Characteristics

Study on the Servo Drive of PM-LSM to Be Used in Parallel Synchronous Drive

Low Speed Wind Turbines. Current Applications and Technology Development

A Comparative Study of Constant Speed and Variable Speed Wind Energy Conversion Systems

Fachpraktikum Elektrische Maschinen. Theory of Induction Machines

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Unit III-Three Phase Induction Motor:

Transient analysis of a new outer-rotor permanent-magnet brushless DC drive using circuit-field-torque coupled timestepping finite-element method

Anupam *1, Prof. S.U Kulkarni 2 1 ABSTRACT I. INTRODUCTION II. MODELLING OF WIND SPEED

Regulation: R16 Course & Branch: B.Tech EEE

Wind Turbine Emulation Experiment

International Journal of Advance Research in Engineering, Science & Technology

International Journal of Advanced Engineering Research and Studies E-ISSN

14 Single- Phase A.C. Motors I

International Journal of Computer Engineering and Applications, Volume XII, Special Issue, March 18, ISSN

Closed Loop Control of Separately Excited DC Motor

Modelling and Simulation of DFIG with Fault Rid Through Protection

Lab 1: DC Motors Tuesday, Feb 8 / Wednesday, Feb 9

Application of linear magnetic gears for pseudo-direct-drive oceanic wave energy harvesting

Using energy storage for modeling a stand-alone wind turbine system

CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR

A Practical Guide to Free Energy Devices

CHAPTER 2 SELECTION OF MOTORS FOR ELECTRIC VEHICLE PROPULSION

Iowa State University Electrical and Computer Engineering. E E 452. Electric Machines and Power Electronic Drives

Dynamic Response Analysis of Small Wind Energy Conversion Systems (WECS) Operating With Torque Control versus Speed Control

PERFORMANCE ANALYSIS OF BLDC MOTOR SPEED CONTROL USING PI CONTROLLER

ELECTRICAL MACHINES-II LABORATORY MANUAL

Permanent Magnet DC Motor Operating as a Generator

Design, Development and Testing of 3-phase Permanent Magnet Machines and their Converters

SHRI ANGALAMMAN COLLEGE OF ENGINEERING AND TECHNOLOGY (An ISO 9001:2008 Certified Institution) SIRUGANOOR, TIRUCHIRAPPALLI

Permanent Magnet DC Motor

Modeling and Simulation of A Bldc Motor By Using Matlab/Simulation Tool

Modeling the Neuro-Fuzzy Control with the Dynamic Model of the Permanent Magnet DC Motor

QUESTION BANK SPECIAL ELECTRICAL MACHINES

Transcription:

R. A. Msuya, et al. ANALYSIS OF POWER EFFICIENCY OF A DIRECT-DRIVEN LOCALLY FABRICATED PERMANENT MAGNET AC GENERATOR FOR SMALL-SCALE WIND POWER APPLICATIONS IN TANZANIA R.A. Msuya 1, R.R.M. Kainkwa 1, M.I. Mgwatu 2 1 Departrment of Physics, College of Natural and Applied Sciences, University of Dar es Salaam, Tanzania 2 Department of Mechanical and Industrial Engineering, College of Engineering and Technology, University of Dar es Salaam, Tanzania ABSTRACT The use of direct-driven permanent magnet alternating current (AC) generators offers the opportunity to reduced costs and increased system efficiency. This type of generator could be the best alternative for rural population whom are not connected to the national grid. To improve the design and efficiency of locally fabricated generators, it is imperative to characterize both their mechanical and electrical parameters. This paper presents the analysis of power efficiency of the synchronous permanent AC generator locally fabricated in Tanzania. In this case, load resistance and rotational speed are characterized using designed experiment. The output current and voltage of the generator were recorded simultaneously in each step change of load resistance and rotational speed. The output power and efficiency were then determined analytically. The results show that there is a linear relationship between voltage and rotational speed of the generator with and without load resistance. The results further indicated that out power is not linearly related to rotational speed. The generator s power efficiency was found to be about 55% against both the output voltage and rotational speed. Keywords: Wind power efficiency, permanent magnet ac generator, experimental design. INTRODUCTION Wind turbine generators as electrical machines are usually divided into three major groups known as direct current (DC) machines, asynchronous alternative current (AC) machines and synchronous AC machines. Currently, DC machines are not widely used due to high maintenance costs associated with them. In most cases, the load winding of AC generators consists of three phases (Hansen at el., 2001). In this paper, discussion and analysis will involve permanent magnet AC wind generator, three phase machine with an outer stator carrying the main (primary) winding. The rotor is arranged inside the stator with permanent magnet, and the air gap separating the inner part of the stator and outer rotor surfaces. The interacting magnetic field crossing the air gap is in radial direction couples stator and rotor. The major characteristics of a permanent magnet generator (PMG) is that the magnetization in the windings is provided by a permanent magnet pole system on the rotor, instead of taking excitation current from the armature winding terminals as in other types of generators like Induction Generator (IG). This means that the mode of operation is synchronous, as opposed to asynchronous. Therefore, the output frequency of PMG 84 Tanzania Journal of Engineering and Technology, (TJET) Vol. 4 (No. 2), December, 2013

Analysis of Power Efficiency of Direct-Driven Locally Fabricated Permanent Magnet AC Generator for Small-scale Power Application in Tanzania bears a constant relationship to the shaft speed. Almost all electrical power generated by three-phase a.c. generators are synchronized with the utility to the end user. A three-phase generator in most cases are smaller, less expensive, and more efficient as compared to singlephase generator of the same power. This shows the importance of using three phase generator whenever possible (Johnson, 2006). The main advantage of permanent magnet synchronous generators over other generators is due to the fact that it does not require any external excitation current, which translates in a significant decrease in rotor losses. Furthermore, permanent magnet machines have high torque than other type of generator of same size and can be designed in many different configurations. This type of wind generators is mostly used in small scale wind harvesting system using permanent magnet synchronous generators. The type of generator considered in this study is the direct driven PMG three phase AC machine with maximum power of 1000 W. Typical sizes that are manufactured in industries of this type of generators range between 250 W and 2 kw. Small scale wind turbine generator system in most cases operates in low wind speed efficiently from 3.5 m/s. This system is a variable-speed as wind speed varies with time. The extractable wind power, P e, is described by equation (1) (Johnson, 2006): 1 Pe ρ 3 AV C p (1) 2 where ρ is the density of air, V is wind speed available to the rotor, A is the cross sectional area of rotor and C p is the efficiency of the wind turbine. The theoretical maximum value of C p is 0.59, but the practical limit is 0.5, attaining C p above 0.4 is considered good (Stiebler, 2008 and Vongmanee, 2009). The maximum power that can be extracted by a Wind Energy Conversion System (WECS) is 59.3% of the total available wind power (Johnson, 2006). Practical values range between 25% and 30%. This is due to wind speed variation, type of WECS and the type of applied resistive load. The power in the wind is converted to mechanical power which is transmitted to the generator through a mechanical transmission power, P i, which is then converted to electricity with an electrical power P o. The generator s power output efficiency η can be expressed as: Po η 100% (2) P i A generator that is directly connected to the rotor is better especially in small scale wind turbines where electronic systems are rarely used. Some of the benefit associated with this fact is lower nacelle weight, less noise and vibrations, low power loss and less service required at the nacelle. The PM generator that was used in this study has eight pole pairs with 1 kw power output (private communication with Matia (2012), the native technician who fabricated the generator). METHODS AND MATERIALS The synchronous permanent a.c. generator locally fabricated in Tanzania was characterized and analyzed using both experimental and analytical methods. The generator was designed with the following technical characteristics: (a) Rated power: 1 kw, (b) Maximum rated rotor speed 200 rpm, (c) Rated speed 8 m/s, (d) Maximum power: 1.5 kw, (e) Output voltage : 12-64 V, (f) Cut in wind speed 3.5 m/s, and Tanzania Journal of Engineering and Technology, (TJET) Vol. 4 (No. 2), December, 2013 85

R. A. Msuya, et al. (g) Cut out wind speed 30 m/s. Two factors namely rotational speed (rpm) and load resistance (Ohm) were identified for the experiments. Each factor has nine levels resulting into a total of 81 experiments conducted in set combinations. The values of rotational speed and load resistance shown in Table 1 were recorded through experimental trials, which aimed at determining their operational ranges. The trials were done repeatedly for error minimization and to have the precise ranges of rotational speed and load resistance. Table 1: Factors Rotational Speed (rpm) Load Resistance (Ohm) Design of experiment based on rotational speed and load resistance Factor levels 1 2 3 4 5 6 7 8 9 79.9 116 144.2 183.3 223 261 274 340 371.4 17.9 18.2 18.6 19 19.5 19.8 20.2 20.5 21.1 The experimental set-up was as shown in Figure 1(a) and Figure 1(b). The thyristor converter supplied the power to the DC machine which was a prime mover. The rotational speed of the DC machine was measured by hand held tachometer (S), which is also noted as (9) in Figure 1(a). This was done through reflecting tape (7) attached to coupling (10) as shown in the Figure 1(a) and Figure 1(b). The rotational speeds were recorded after varying the load resistance from 17.9 to 21.1 Ohms in nine steps. The variation of load resistances was carefully monitored for the safety of the generator. As observed in the figures, the fixed resistive load (1) was valued 16 Ohms and attached in each phase of the generator separately as the generator has three phase. Each phase was attached also separately to the variable resistance (2) which was set to vary from 1.9 to 5.1 Ohms. Hence, each phase was varied from 17.9 to 21.1 Ohms equally. The output current was recorded through power meter (3) and the values of voltage per phase were recorded through voltmeter (4). At the same time readings for the frequency were taken using multimeter (4) and oscilloscope (5). On the other hand, the reading of the voltage and current of the DC machine (8) were simultaneously taken in each step change of rotational speed and variable resistance. The locally fabricated generator is indicated by number (6). The experiment started by running the generator with no load. The variation of the rotational speed was done while taking the readings of output voltage of generator and at the same time the value of the DC voltage and current was recorded in the thyristor converter. At this stage of experiment, the values of phase resistances were measured for both generators and the internal resistance of the DC machine. The experiment was conducted again with load, while varying the resistance in the nine steps for each stage of rotational speed. The speed was also varied in nine stages, while taking the readings of output voltage and current for the generator. The input values of DC voltage and current was also recorded. The electric circuit representation of the experimental set up and mode of data recording is shown in Figure 2. From the data recorded during the experiment the following parameters of the generators were realized: (i) Generator output power, (ii) Mechanical input power from the DC machine, and (iii) Generator efficiency. 86 Tanzania Journal of Engineering and Technology, (TJET) Vol. 4 (No. 2), December, 2013

Analysis of Power Efficiency of Direct-Driven Locally Fabricated Permanent Magnet AC Generator for Small-scale Power Application in Tanzania The arrangement of the AC generator, DC machine and thyristor converter is shown in Figure 3 while the equivalent circuit of the DC Machine is shown in Figure 4. The equivalent circuit was employed in the analysis of the AC generator. All sets of experimental tests were conducted at the Department of Electrical Power Engineering, Chalmers University of Technology in Sweden. The data collected was analysed using Matlab and Origin Pro software packages. Figure 1(a): Pictorial representation of the laboratory experimental set-up Figure 1(b): Schematic experimental set-up of AC generator Tanzania Journal of Engineering and Technology, (TJET) Vol. 4 (No. 2), December, 2013 87

R. A. Msuya, et al. Figure 2: Circuit diagram of generator test Figure 3: Alignment of AC generator, DC machine and Thyristor converter Figure 4: Equivalent circuit of the DC Machine THEORETICAL CONCEPTS Data which were measured in the DC machine included armature current (I a ), armature voltage (V a ), revolution per minute (ω) and internal resistance of DC machine (R dc ). Equation (3) was used for estimation of armature voltage (V a ) (Henneberger, 2005; Mohamed, 2000): V a I R E (3) a dc bac where Ebac is back emf produced by the DC Machine. 88 Tanzania Journal of Engineering and Technology, (TJET) Vol. 4 (No. 2), December, 2013

Analysis of Power Efficiency of Direct-Driven Locally Fabricated Permanent Magnet AC Generator for Small-scale Power Application in Tanzania But back emf can also be expressed as: E bac ωkφ (4) where Kφ is a DC machine constant. The value of R dc which is a DC Machine Resistance was directly measured by multi-meter. By substituting Equation (4) into Equation (3), V a, can be represented by equation (5). V a I R ωkφ (5) a dc By making DC machine constant Kφ the subject, equation (6) was obtained. Va I ardc Kφ (6) ω The Torque T e can then be calculated using equation (7). T Kφ (7) e I a The mechanical input power (P i ) to generator can be calculated using equation 8. P T e (8) i Equation (9) was obtained by substituting T e from Equation (7) into equation (8). P K I (9) i a For the standard procedures the value of ω should be divided by 60 to have rad/sec (i.e. ω/60 rad/sec). For the AC generator, electrical output power can be obtain from equation (10). P V I (10) o o o But for delta connections, line voltage (V L ) is equal to phase voltage (V ph ) so that: VL V ph (11) The line current (I L ) is equal to I ph 3 which can thus be expressed as: I 3 (12) L I ph Substituting Equations (11) and (12) in Equation (10), electrical power output can be calculated using equation (13). P V I 3 (13) out ph ph Based on the derived theoretical concepts, the efficiency can now be calculated by substituting Equations (9) and (13) in Equation (2). RESULTS AND DISCUSSION The characteristic curve of voltage against rotational speed for the AC generator with no load resistance is shown in Figure 5. The graph shows that there is a linear relationship between the two variables. The maximum output voltage was about 65 V, a value that was obtained at the rotational speed of about 350 rpm. As depicted in Figure 6, the same linear relationship was obtained when a load resistance was applied to the generator. The maximum voltage was about 40 V, a value that was observed at the rotational speed of about 300 rpm. The characteristic graph of output power against rotational speed is shown in Figure 7 for load resistances 21.9, 19.5 and 17.9. The graph shows that output power is not linearly related to rotational speed. The graph indicates that the maximum output power was 80 W, the value that was attained at the rotational speed of about 300 rpm. The efficiency of the generator as a function of voltage and rotational speed are respectively depicted in Figure 8 and Figure 9. It is indicated in Figure 8 that the efficiency of the generator is about 55% against voltage. As noted in the figure, this value is more or less similar for all the resistances used in the experiment. The figure further shows that the efficiency of the machine decreases as the resistance increases. At a voltage of about 10V, the efficiency reaches the maximum. Figure 9 on the other hand Tanzania Journal of Engineering and Technology, (TJET) Vol. 4 (No. 2), December, 2013 89

R. A. Msuya, et al. shows that the efficiency against rotational speed has similar trend of that against voltage in Figure 8. In similar manner, the efficiency as a function of rotational speed tends to decrease as resistance increases. The maximum efficiency is attained at the rotational speed of about 80 rpm. 70 V1-2 V2-3 V3-1 60 50 Voltage (V) 40 30 20 10 50 100 150 200 250 300 350 Speed (Rpm) Figure 5: Measured voltage against rotational speed with no load 45 40 R=21.1 R=19.5 R=17.9 35 30 Voltage (V) 25 20 15 10 5 50 100 150 200 250 300 Speed (Rpm) Figure 6: Measured Voltage against rotational speed with load resistance 90 Tanzania Journal of Engineering and Technology, (TJET) Vol. 4 (No. 2), December, 2013

Analysis of Power Efficiency of Direct-Driven Locally Fabricated Permanent Magnet AC Generator for Small-scale Power Application in Tanzania Figure 7: Output power against rotational speed with variable load resistance 60 Efficiency (%) 50 40 30 20 10 R=17.9 R=18.2 R=18.6 R=19.0 R=19.5 R=19.8 R=20.2 R=20.5 R=21.1 5 10 15 20 25 30 35 40 45 Voltage (V) Figure 8: Efficiency against voltage with variable resistance Tanzania Journal of Engineering and Technology, (TJET) Vol. 4 (No. 2), December, 2013 91

R. A. Msuya, et al. 60 R=17.9 R=19.8 R=21.1 50 Efficiency (%) 40 30 20 10 50 100 150 200 250 300 Speed (Rpm) Figure 9: Efficiency against rotational speed with variable resistance CONCLUSIONS This study has highlighted the experimental design for the analysis of power efficiency of the synchronous permanent AC generator locally fabricated in Tanzania. The main idea was to determine the power efficiency of the generator in respect to voltage and rotational speed at varying load resistance. The locally fabricated generator was mounted on the test rig and tested. To accomplish the study, the experiments were designed to characterise the combinations of load resistance and rotational speed each in nine levels of these two variables. The results show that there is a linear relationship between voltage and rotational speed of the generator with and without the existence of load resistance. The results further indicate that there is no linear relationship between output power and rotational speed. The power efficiency of the local generator is about 55% against the output voltage as well as the rotational speed. This efficiency seems to be low and as such necessary efforts should be devoted to improve it. It is also recommended that the actual field test be conducted to confirm the system performance in the real environment. ACKNOWLEDGMENT The authors wish to thank the Sida Renewable Energy Programme of the University of Dar es Salaam for funding this research. The authors would also like to thank Mr. Joseph Matia for providing the fabricated wind turbine generator used in the experimental study. Many thanks are directed to Dr. S.G.J. Ehnberg of the Department of Electric Power Engineering, Chalmers University of Technology in Sweden for his sincere assistance in developing the experimental set-up in the laboratory. REFERENCES Hansen, L. Helle, F. Blaabjerg, E. Ritchie, S. Munk- Nielsen, H. Bindner, P. Sørensen and B. Bak-Jensen Risø, (2001). Conceptual survey of Generators and Power Electronics for Wind Turbines, L.H. National Laboratory, Roskilde, Denmark. Henneberger, G. (2005). Electrical Machines I, Basics, Design, Function, 92 Tanzania Journal of Engineering and Technology, (TJET) Vol. 4 (No. 2), December, 2013

Analysis of Power Efficiency of Direct-Driven Locally Fabricated Permanent Magnet AC Generator for Small-scale Power Application in Tanzania Operation based on a Lecture at Aachen University. Johnson, L.G. (2006). Wind Energy Systems: Electronic edition. Mohamedi, A. (2000). Fundamentals of Electric Drives. Cole Publishing Company USA. Stiebler, M. (2008). Wind Energy Systems for Electric Power Generation. Inst. of Energy and Automation Technology Einsteinufer 11, D-10587 Berlin Germany. Vongmanee, V. (2009). Emulator of Wind Turbine Generator Using Dual Inverter Controlled Squirrel Cage Induction Motor. University of the Thai Chamber of Commerce, Bangkok, Thailand. Tanzania Journal of Engineering and Technology, (TJET) Vol. 4 (No. 2), December, 2013 93