Ducting & Ventilation Components

Similar documents
Replacement Tubes for Gillian Gas Detection Pumps

Colorimetric Gas Detector Tube System US Dollar Price List

Completing Your Fume Removal System

Fume Hood Exhaust Blowers. HEPA & Carbon Filtration. Ducting & Exhaust. Fume Scrubbers HEMCO. Manifolds. ISO Certified Company

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials

FILTRATION SYSTEMS CARBOX PHARMACEUTICAL HOODS ACTIVATED CHARCOAL FILTERS

Protector Demonstration Hoods

Blower Specifications

P17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A

Ventilated Balance Enclosures

APOVAC R Vacuum Systems

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

Air Boss M-Series Media & Adsorption Air Cleaner

Dräger CMS. Dräger CMS: Highly accurate and easy to use. Dräger CMS Chip: Miniaturised Dräger-Tubes.

Beverage Grade Carbon Dioxide

ENVIRO UNIT CES SERIES

Dräger CMS Chip Measurement System

This convenient system is made entirely of inert parts: glass, Baseline drift

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy

EXPLOSION-PROOF MOTORS SINGLE PHASE

SECTION HVAC AIR CLEANING DEVICES

PRECISE. Glove Boxes

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

The Industrial Choice. Model TFBD. Model FBD FIBERGLASS AXIAL FLOW FANS. Model FDP / FRV / FBD / TFBD / VTFBD

HD and HDL Single-Stage Non-Lube Gas Compressors

EZ-View. Flow Meters ISO CERTIFIED 9001


VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

forward curved inline duct blowers

LABORATORY FUME HOODS OF 5

Issue One. Chemical Compatibility Guide

VANEAXIAL & TUBEAXIAL FANS

Custom Shipyard and Military Facility Products

Application Data Sheet. Chemical Compatibility Chart. IND-AS EN-01 (May, 2014) Metals Plastics Seals KEY. Good. Fair. Ethylene Propylene.

HSNO Class Flammable Liquids

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

How to Use the Chemical Compatibility Chart. Vials and Closures >> Chemical Compatibility Chart

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

FASTER ChemFAST. Laboratory Fume Cupboards PROTECTION, SAFETY, RELIABILITY. AND MORE.

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

Non-contractual document. Any reproduction, in whole or in part, by whatsoever process, is only permitted with Gazdetect approval.

Operating Manual MAC-21 VFD

Air Boss CA3000C & CA6000C. Installation Operation Maintenance Manual. Cartridge Air Cleaners

Protector Airo Filtered Fume Hoods

Corrosion Control for Control Rooms & Process Control Environments AIRBORNE PARTICULATE AND GASEOUS CONTAMINANT SOLUTIONS

Application & Installation Guide. Crankcase Ventilation Systems LEBW

Professional Chemical Analyzer Service / BigDipper TechnoChem Institute, Beijing China. Hand held Single Gas Analyzer H-BD5gas

Operating Manual PFB-2500

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

Filtration efficiency: 99% or more HEPO2element

P17 combined units LIMOGES Cedex Telephone : Fax : Cat. No.(s) : 566 XX XX XX XX

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

HYPRA Prisinter 16/32/63 A

Industrial Mini Vent Sets

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

Precise Glove Boxes & XPert Weigh Boxes

Filtration efficiency: 99% or more

2520- EC Motor Speed Controller

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

Vogt Valves The Connection Bulletin for Fugitive Emissions A Leakage Viewpoint CB 12

Tank Truck Product Integrity Protection Guidelines 4 th Edition, Revision 1 August 27, Normal Alpha Olefins Polyalphaolefins

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

TUBULAR CENTRIFUGAL INLINE FANS

Selection of DODGE E-Z KLEEN Polymer and Stainless Steel Housed Ball Bearings. P = (X x F R ) + (Y x F A ) F A C o

Pressure switch FF 4 Approval acc. to ATEX EN For mining and chemistry

Safety Products brochure 11 Int INDEX. Exhaust Filters 2. Air Inlet Valve 5. GL45 Caps 6. DIN50 Caps 8. GL38 Caps 10. DIN60 Caps 11.

Dust Collectors and Fume Exhausters

Small on price, big on boot

3.5 Exposure Control Measures

Defining Innovation. backward curved FANs

Clean Air Products Straight Thru Standard Profile Single Door Air Shower Purchase Specification

Solvent Recovery - Solvent Recycling - Solvent Distillation

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

EXHAUST FANS CUD & CUB UPBLAST FANS

Magnetic Drive Gear Pumps

Presented by: Richard M. Cestone, PE, CHMM Senior Project Engineer Remington & Vernick Engineers For New Jersey Water Environment Association

Softening point by Ring & Ball. Density and relative density of liquids by Hubbart pycnometer

Antek Gas Chromatography Products: A Guided Tour Through Industry

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

Accessories Standard Service Fixture Kits

Section J Air Control Nozzles

Model ND-2 Specification

ANALYTICAL RESULTS. PWS ID/Name: ROCKHOUSE MOUNTAIN - CONWAY Report Date: 03/29/2016

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Global Finishing Solutions Table of Contents

Indoor Air Quality Solutions for Machining Applications MistBuster source collection and MX-Series centralized filtration

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

Safety Products brochure 11 Int INDEX. Exhaust Filters 2. Air Inlet Valve 5. GL45 Caps 6. DIN50 Caps 8. GL38 Caps 10. DIN60 Caps 11.

Strength, resilience, rigidity - these are all attributes needed to combat arduous and aggressive conditions. Tufflite has them all.

EF 8 EF 9. Company name Idemitsu Nippon Oil Cosmo Oil Showa Shell Sekiyu TonenGeneral Sekiyu Japan Energy

CRYSTAL-AIRE. concealed commercial air cleaners

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Protector XStream Laboratory Hoods

Transcription:

Ducting & Ventilation Components 111 Powell Road Independence, MO 64056 visit www.hemcocorp.com Phone: 816-796-2900 Fax : 816-796-3333 E-Mail : info@hemcocorp.com

Exhaust Blowers are constructed of chemical resistant epoxy-coated steel. They feature adjustable-pitch sheaves for field/balancing, weather cover and adjustable discharge. 115/230 volt, 60hz, single-phase motor is designed to the specific ventilation application requirement. For 50Hz requirements add 50 suffix to blower model number. Exhaust Blowers Inlet Outlet 1/2" Static Pressure 3/4" Static Pressure 1" Static Pressure 1 1/2" Static Pressure Item CFM Dia. Size HP Catalog # HP Catalog # HP Catalog # HP Catalog # 1 296 8 7/8" 10 1/8" x 4 1/8" 1/4 # 51701 1/4 # 51702 1/4 # 51703 1/4 # 51704 2 474 8 7/8" 10 1/8" x 4 1/8" 1/4 # 51705 1/4 # 51706 1/4 # 51707 1/2 # 51708 3 652 8 7/8" 10 1/8" x 6 3/8" 1/2 # 51709 1/2 # 51710 1/2 # 51711 1/2 # 51712 4 800 8 7/8" 10 1/8" x 6 3/8" 1/2 # 51713 1/2 # 51714 1/2 # 51715 3/4 # 51716 5 914 9 7/8" 11 1/2" x 8 1/4" 1/2 # 51717 1/2 # 51718 - - - - 6 1044 9 7/8" 11 1/2" x 8 1/4" 1/2 # 51719 1/2 # 51720 3/4 # 51721 - - 7 1175 9 7/8" 11 1/2" x 8 1/4" 1/2 # 51722 1/2 # 51723 3/4 # 51724 - - 8 1240 9 7/8" 11 1/2" x 8 1/4" 1/2 # 51725 1/2 # 51726 3/4 # 51727 3/4 # 51728 9 1240 11 7/8" 13 3/8" x 8 1/4" 1/3 # 51729 1/2 # 51730 - - - - 10 1506 11 7/8" 13 3/8" x 8 1/4" 1/2 # 51731 1/2 # 51732 3/4 # 51733 - - 11 1771 11 7/8" 13 3/8" x 8 1/4" 1/2 # 51734 3/4 # 51735 3/4 # 51736 1 # 51737 12 2037 11 7/8" 13 3/8" x 8 1/4" 1 # 51738 1 1/2 # 51739 1 1/2 # 51740 1 1/2 # 51741 Hood Ventilation - Page 2

Explosion Proof Exhaust Blowers are also constructed of chemical resistant epoxy-coated steel and equipped with a coated nonsparking aluminum impellar wheel and include adjustable pitch sheaves for field balancing and weather cover and adjustable discharge. The motor is a 115/230 volt, hazardous location designated motor and is designed to the specific ventilation requirement. For 50Hz requirements add 50 suffix to blower model number. Explosion Proof Blowers Inlet Outlet 1/2" Static Pressure 3/4" Static Pressure 1" Static Pressure 1 1/2" Static Pressure Item CFM Dia. Size HP Catalog # HP Catalog # HP Catalog # HP Catalog # 1 296 8 7/8" 10 1/8" x 4 1/8" 1/4 # 51801 1/4 # 51802 1/4 # 51803 1/4 # 51804 2 474 8 7/8" 10 1/8" x 4 1/8" 1/4 # 51805 1/4 # 51806 1/4 # 51807 1/2 # 51808 3 652 8 7/8" 10 1/8" x 6 3/8" 1/2 # 51809 1/2 # 51810 1/2 # 51811 1/2 # 51812 4 800 8 7/8" 10 1/8" x 6 3/8" 1/2 # 51813 1/2 # 51814 1/2 # 51815 3/4 # 51816 5 914 9 7/8" 11 1/2" x 8 1/4" 1/2 # 51817 1/2 # 51818 - - - - 6 1044 9 7/8" 11 1/2" x 8 1/4" 1/2 # 51819 1/2 # 51820 3/4 # 51821 - - 7 1175 9 7/8" 11 1/2" x 8 1/4" 1/2 # 51822 1/2 # 51823 3/4 # 51824 - - 8 1240 9 7/8" 11 1/2" x 8 1/4" 1/2 # 51825 1/2 # 51826 3/4 # 51827 3/4 # 51828 9 1240 11 7/8" 13 3/8" x 8 1/4" 1/3 # 51829 1/2 # 51830 - - - - 10 1506 11 7/8" 13 3/8" x 8 1/4" 1/2 # 51831 1/2 # 51832 3/4 # 51833 - - 11 1771 11 7/8" 13 3/8" x 8 1/4" 1/2 # 51834 3/4 # 51835 3/4 # 51836 1 # 51837 12 2037 11 7/8" 13 3/8" x 8 1/4" 1 # 51838 1 1/2 # 51839 1 1/2 # 51840 1 1/2 # 51841 Blower Outlet Transition needed for blower Item above Item Catalog # 1 # 82250 2 # 82251 3 # 82252 4, 5, 6, 7, and 8 # 82253 9, 10, 11, and 12 # 82254 Hood Ventilation - Page 3

Perchloric Acid Exhaust Blowers are constructed of halar-coated steal and feature v-belt adjustable sheave drive, TEFC motor, nonsparking wheel, wash down nozzle, drain outlet, inlet and outlet flanges, and weather cover. Note blowers below are sized for 100 FPM. Perchloric Acid Exhaust System Blowers Item Hood Size CFM required for 100 FPM Static Pressure HP Catalog # 1 48" 800 1" 1/2 # 51395 2 60" 1000 1" 1/2 # 51396 3 72" 1200 1" 3/4 # 51397 Optional stainless steel stack outlet with wash down nozzles 6' high Cat. # 51399 Hood Ventilation - Page 4

Clean-Aire Filtration Systems HEMCO Clean-Aire Filtration Systems are specifically designed to remove particulate and/or fumes from the exhaust air stream of a laboratory UniFlow fume hood. The filter systems effectively clean the air of contaminants prior to discharging into the atmosphere to meet EPA regulations. Also, in some cases, depending on the contaminant, the exhaust can re-circulate back to the lab. HEMCO filtration systems are offered as a Clean-Aire Pak or Clean-Aire Bag-in Bag-out Filter Pak. A HEPA filter is provided to collect particulate, a carbon filter is provided to adsorb fumes and odors, or a combination of the two filters can be assembled as one module. Clean-Aire HEPA Filter Pak The HEPA Filter Pak is designed to collect airborne particulate from the exhaust. The filter pak housing is constructed with a convenient latched/hinged access door for filter change out. Inlet and outlet plenums with duct connection collars are installed. Note: 1. The HEPA filter is not included with the housing. Please select HEPA filter below. 2. We recommend a minihelic or magnehelic gage to monitor the airflow differential across the filter. The static pressure indicated would alert when to change the filter. The gages can be hood or filter mounted. 3. We recommend ordering a back-up replacement filter. Item Product Description CFM Dimensions Duct Size (diameter) Catalog Number 1. Clean-Aire HEPA Filter Pak 250-650 26 x 15 x 35 ½ 4, 6 # 50188 2. Clean-Aire HEPA Filter Pak 650-1200 26 x 26 x 35 ½ 8, 10, 12 # 50189 3. HEPA Filters 550 24 x 12 x 12 # 50094 4. HEPA Filters 1100 24 x 24 x 12 # 50095 5. Prefilter 6 per carton 500 24 x 12 x 2 # 52000 6. Prefilter 6 per carton 1000 24 x 24 x 2 # 52001 Hood Ventilation - Page 5

Clean-Aire HEPA Filter Bag In Bag Out System Filter housing is fabricated of type-304 stainless steel and includes (1) HEPA-99.99% efficient at 0.3 microns and larger, (1) 24 x 24 x 2 30% pleated prefilter, and 1 bag. Bag In-Bag Out filters are designed to meet air filtration requirements to handle hazardous particulate materials. The housing incorporates a ribbed bagging ring around the side access door over which a specially designed plastic bag is attached. Filters are then installed and changed through the bag to reduce the risk of exposure to personnel. Note: 1. The HEPA filter is not included with the housing. Please select HEPA filter below. 2. We recommend a minihelic or magnehelic gage to monitor the airflow differential across the filter. The static pressure indicated would alert when to change the filter. The gages can be hood or filter mounted. 3. We recommend ordering a back-up replacement filter. Item Product Description CFM Dimensions Catalog Number 1. Clean-Aire HEPA Filter Bag In Bag Out System 1000 26 x 26 x 35 ½ # 51189 2. HEPA Filter 1000 24 x 12 x 12 # 50094 3. Prefilter - 6 per carton 1000 24 x 12 x 2 # 52000 4. Replacement Bags - 2 per carton # 51999-H Hood Ventilation - Page 6

Minihelic Gauge Gauge monitors the pressure differential across the HEPA filter, Gauge conveniently mounts on the fume hood or on the filter housing. Measure range is from 0 to 2.0 wg Gauge is 3 dia. with 5% accuracy Cat. # 51300 Minihelic gauge #51300 Magnehelic Gauge Gauge measures static pressure across the HEPA filter. Can mount on the fume hood or the filter housing. Range of measurement is from 0 to 2 wg. Gauge is 5 dia with 2% accuracy. Cat. # 51301 Magnehelic gauge #51301 Hood Ventilation - Page 7

Clean-Aire Carbon Filter Pak The Carbon Filter Pak is engineered to remove undesirable fumes and odors from a Uniflow fume hood exhaust system. The filter pak housing is constructed with a convenient latched/hinged access door for filter change out. Inlet and outlet plenums with duct connection collars are installed. Note: 1. The carbon filter is not included with the housing. Please review the adjacent contaminant chart and select the appropriate carbon filter. 2. We recommend that the sampling kit below to check if there has been break through in the carbon filter. 3. We recommend ordering a back-up replacement filter. Item Product Description CFM Dimensions Duct Size (diameter) Catalog Number 1. Carbon Filter Pak 250-650 26 x 15 x 35 ½ 4, 6 # 50297 2. Carbon Filter Pak 650-1200 26 x 26 x 35 ½ 8, 10, 12 # 50298 3. Carbon Filters 500 # 52100 4. Carbon Filters 1100 # 52101 5. Prefilter 6 per carton 500 24 x 12 x 2 # 52000 6. Prefilter 6 per carton 1000 24 x 24 x 2 # 52001 Hood Ventilation - Page 8

Clean-Aire Carbon Filter Bag In Bag Out System Filter housing is fabricated of type-304 stainless steel and includes (1) Carbon Filter Absorber, (1) 24 x 24 x 2 30% pleated prefilter and (1) bag. Bag In-Bag Out filters are designed to meet air filtration requirements to handle hazardous fumes and vapors. The housing incorporates a ribbed bagging ring around the side access door over which a specially designed plastic bag is attached. Filters are then installed and changed through the bag to reduce the risk of exposure to personnel. Note: 1. The carbon filter is not included with the housing. Please review the adjacent contaminant chart and select the appropriate carbon filter. 2. We recommend that the sampling kit below to check if there has been break through in the carbon filter. 3. We recommend ordering a back-up replacement filter. View the Contaminant Chart for carbon type(s). Catalog Item Product Description CFM Dimensions Number 1. Clean-Aire Carbon Filter Bag In Bag Out System 1000 26 x 26 x 35 ½ # 51198 2. HEPA Filters 1000 # 53101 3. Prefilter 6 per carton 1000 # 50001 4. Replacement Bags - 2 per carton # 51999-C Hood Ventilation - Page 9

Air Monitor Sampling Kit Kit allows you to sample from a carbon filter system to determine if there has been contaminant break through. The air monitor system includes a non-sparking gas sampling pump, instruction sheet, rubber tube holder with filter, lubricant, piston gasket and handy carrying case. Detector tubes are not included. Air Monitor Sampling Kit - Cat. # 89300 Ordering Detector Tubes for Kit, download Detector Tubes List Hood Ventilation - Page 10

Fume & Vapor Clean Aire Scrubbers Scrubber systems offer high efficiency and minimal maintenance on meeting pollution control requirements. Clean Aire Scrubber Provides excellent air pollution control for water soluble fumes and odors by moving contaminated air through a filter pack media exposing over forty square feet of surface per cubic foot. Contaminant is collected on filter media surface and rinsed off with water. Excess water is then mechanically removed and cleaned air is released. When conditions require, chemical additives can increase absorptive capacity of the scrubber. Unit includes integral re-circulation tank and pump which significantly reduces water consumption and related waste disposal costs. Fan is not included, must be sized to meet exhaust requirements. Chick here for HEMCO s Plan-A-Scrubber Remote Recirculation Tank & Pump can be supplied for installations where the scrubber is located outdoors and the possibility of freezing exists. ph Control Package Allows precise control over effluent quality and provides neutralization of contaminants. The ph control system consists of a weather-tight, corrosion-proof enclosure containing an analyzer, pre-wired chemical feed pump, weather-protected terminal block, clear PVC face plate and external chemicalfeed connection. Enclosure can be mounted on any vertical surface. A heavy-duty industrial probe with a 10 ft. lead wire is supplied, along with two 10 ft. lengths of vinyl tubing to connect the feed pump. Hood Ventilation - Page 11

Ducting & Ventilation Components 111 Powell Road Independence, MO 64056 visit www.hemcocorp.com Phone: 816-796-2900 Fax : 816-796-3333 E-Mail : info@hemcocorp.com Ducting & Ventilation Components Page 1

Ducting & Ventilation Components Page 2

Ducting Diameters and Ventilation Components for HEMCO fume hoods Item Product Description 1.* FLEXIBLE DUCTING excellent for chemical fume exhausting made of thermo plastic rubber reinforced with steel helix wire. 12 lengths. Each length includes two stainless-steel strap clamps. 2. PVC RIGID DUCTING chemical resistant and durable schedule 40 PVC. 10 lengths with straight ends. 3. PVC COUPLING required to connect to PVC rigid ducting sections. Duct Diameter with Catalog Number 4 6 8 10 12 # 80051 # 80052 # 80053 # 80054 # 80055 # 82004 # 82006 # 82009 # 82011 # 82013 # 82147 # 82149 # 82153 # 82157 # 82159 4. PVC 90 ELBOW connects with PVC rigid ducting. # 82060 # 82061 # 82063 # 82066 # 82068 5.* PVC 45 ELBOW connects with PVC rigid ducting. # 82082 # 82083 # 82085 # 82087 # 82089. 6.* PVC 45 WYE Lateral for joining common duct work in multiple hood designs. Branch diameter may be sized equal to 2 to 4 smaller than main diameter. Connects to PVC rigid ducting. 7.* PVC TEE for manifold exhaust systems. Connects to PVC rigid ducting. # 82216 # 82218 # 82226 # 82229 # 82233 # 82034 # 82036 # 82038 # 82040 # 82044 Ducting & Ventilation Components Page 3

Ducting Diameters and Ventilation Components for HEMCO fume hoods Item Product Description 8. PVC BALANCING DAMPER modifies CFM for single or multiple hood arrangements. Connects to PVC rigid ducting. 9. PVC RAIN SKIRT slips over straight pipe on roof to slope water away from cutout. Duct Diameter with Catalog Number 4 6 8 10 12 # 82450 # 82452 # 82454 # 82456 # 82458 # 82328 # 82330 # 82332 # 82334 # 82336 10. PVC VENT OUTLET for horizontal venting through wall or window. Angled end prevents rain from entering. Male connection to PVC rigid or flex ducting. 11. ZERO PRESSURE WEATHER CAP discharges fumes vertically away from roof. Self-draining. Minimal static pressure loss. Connects to PVC rigid ducting. 12.* CONDENSATION RING collects condensed vapors in ducting and channels them to a drain outlet. Connects to PVC rigid ducting. 13.* WASH RING suited for use in perchloric acid duct systems. Features a wide angle spray nozzle and supply water connector. Connects to PVC rigid ducting. # 80074 # 80076 # 80077 # 80078 # 80079 # 82350 # 82352 # 82354 # 82356 # 82358 # 82590 # 82591 # 82580 # 82581 Ducting & Ventilation Components Page 4

Ducting Diameters and Ventilation Components for HEMCO fume hoods 14. REDUCER transition Catalog Number A X B (inches) ducting to smaller duct # 82613 6 X 4 diameter sizes and # 82615 8 X 6 connects to PVC rigid # 82617 10 X 8 ducting. Size to blower. # 82619 10 X 12 # 82620 14 X 12 # 82621 16 X 14 Duct Diameter with Catalog Number Item Product Description 4 6 8 10 12 15. BLOWER OUTLET TRANSITION # 82250 # 82251 # 82252 # 82253 # 82254 * Not shown on Typical Fume Hood Exhaust Installation Diagram Ducting & Ventilation Components Page 5

Detector Tubes for Air Monitor Sampling Kit Catalog #89300 Gas/Vapor Measuring Range (ppm) TLV (ppm) Catalog Number Acetic Acid.125-25 10 # 89301 Acetone 50-12,000 500 # 89302 Acetylene.05-4.0% - # 89303 Acid Gases 1-80 - # 89304 Acrylonitrile* 0.1-18 2 # 89305 Amines 1-280 - # 89306 Ammonia 0.2-32% 25 # 89307 Ammonia 0.5-78 25 # 89308 Ammonia 2.5-200 25 # 89309 Ammonia 0.05-3.52% 25 # 89310 Ammonia 10-1000 25 # 89311 Arsine 0.04-10.05 # 89312 Benzene in Aromatics* 1-100 0.5 # 89313 Benzene* 0.125-60 0.5 # 89314 Carbon Dioxide 10-100% 5000 # 89315 Carbon Dioxide 100-4000 5000 # 89316 Carbon Dioxide 300-5000 5000 # 89317 Carbon Dioxide 2.5-40% 5000 # 89318 Carbon Dioxide 0.5-20% 5000 # 89319 Carbon Dioxide 0.13-6% 5000 # 89320 Carbon Monoxide 5-50 25 # 89321 Carbon Monoxide 0.1-10% 25 # 89322 Carbon Monoxide 8-1000 25 # 89323 Carbon Monoxide 1-30 25 # 89324 Chlorine 0.25-10% 0.5 # 89325 Chlorine 25-1000 0.5 # 89326 Chlorine 0.1-16 0.5 # 89327 Chlorine 0.025-2 0.5 # 89328 Chloroform* 0.5-27 10 # 89329 Dimethyl Formamide 0.8-90 10 # 89330 *= 5 Indicating Tubes, 5 Pre Tubes **=9 Indicating Tubes C=TLV Ceiling Limit Order 1

Gas/Vapor Detector Tubes for Air Monitor Sampling Kit Catalog #89300 Measuring Range (ppm) TLV (ppm) Catalog Number Ethyl Alcohol 50-2000 1000 # 89331 Ethylene Glycol 10-100mg/m³ C100mg/m³ # 89332 Formaldehyde 0.1-40 C0.3 # 89333 Formaldehyde 0.05-1 C0.3 # 89334 Gasoline 30-2000 300 # 89335 n-hexane 10-1200 50 # 89336 Hydrazine 0.05-2 0.01 # 89337 Hydrocarbons High Class 100-3000 - # 89338 Hydrocarbons Low Class** 0.05-2.4% - # 89339 Hydrocarbons Petro Distillates 0.5-28mg/L - # 89340 Hydrogen 0.5-2% - # 89341 Hydrogen Chloride 0.2-40 C5 # 89342 Hydrogen Chloride 10-1000 C5 # 89343 Hydrogen Cyanide.36-120 C4.7 # 89344 Hydrogen Fluoride 0.25-100 C3 # 89345 Hydrogen Peroxide 0.5-10 1 # 89346 Hydrogen Sulfide 0.1-4% 10 # 89347 Hydrogen Sulfide 0.25-100 10 # 89348 Hydrogen Sulfide 10-4000 10 # 89349 Hydrogen Sulfide 1-240 10 # 89350 Hydrogen Sulfide 12.5-500 10 # 89351 Isopropyl Alcohol 25-800 400 # 89352 Mercury Vapor 0.05-13.2mg/m³.025mg/m³ # 89353 Methyl Alcohol 20-1000 200 # 89354 Methyl Bromide 2.5-200 1 # 89355 Methyl Bromide 1-36 1 # 89356 Methyl Chloroform* 7-660 350 # 89357 Methylene Chloride* 10-150 50 # 89358 *= 5 Indicating Tubes, 5 Pre Tubes **=9 Indicating Tubes C=TLV Ceiling Limit Order 2

Detector Tubes for Air Monitor Sampling Kit Catalog #89300 Gas/Vapor Measuring Range (ppm) TLV (ppm) Catalog Number Methyl Ethyl Ketone 0.02-6% 200 # 89359 Nitric Acid.1-40 2 # 89360 Nitric Oxides* 2.5-200 25 # 89361 Nitrogen Dioxide 0.5-125 3 # 89362 Oxygen 3-24% - # 89363 Ozone 0.025-3 C0.05 # 89364 Ozone 4-400 C0.05 # 89365 Perchloroethylene 1-70 25 # 89366 Phosphine 0.05-9.8 0.3 # 89367 Stoddard Solvent 50-8000mg/m³ 100 # 89368 Styrene 10-1500 20 # 89369 Styrene 2-100 20 # 89370 Sulfur Dioxide 1.25-200 2 # 89371 Sulfur Dioxide 0.05-10 2 # 89372 Sulfur Dioxide 20-3600 2 # 89373 Sulfuric Acid 1-5mg/m³ 1mg/m³ # 89374 Tetrahydrofuran 20-800 200 # 89375 Toluene 5-600 50 # 89376 Toluene 1-100 50 # 89377 Trichloroethylene 2-250 50 # 89378 Vinyl Chloride 0.25-70 1 # 89379 Water Vapor 0.5-32mg/L - # 89380 Xylene 5-625 100 # 89381 *= 5 Indicating Tubes, 5 Pre Tubes **=9 Indicating Tubes C=TLV Ceiling Limit Order 3