Choose for Your Instrument. GC Supplies - Agilent Instrument Quick Pick Guide

Similar documents
Choose for Your Instrument. GC Supplies - Bruker (Varian) Instrument Quick Pick Guide

GC Supplies - Varian/Bruker Instrument Quick Pick Guide

AZ Chrom s.r.o.

Choose for Your Instrument

Setting up SilFlow for BackFlush in your GC

Sample preparation Methods Analysis. Biodiesel Analysis guide.

Biodiesel Analysis Toolkit

AZ Chrom s.r.o.

Best Selling 30 % OFF* GC Accessories. Expires: September 27, 2013

Selecting The Appropriate INLET LINER

Agilent 6890 Gas Chromatograph

6890 Installing ¼ Glass Columns

CrossLab. Supplies for PerkinElmer GC Systems. to work for you non-agilent GCs. Put Agilent innovation and quality. Agilent. Quick Reference Guide

1310 Inlets. 1 of 36. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

CrossLab. Supplies for Thermo Scientific GC Systems. work for you non-agilent GCs. Put Agilent innovation and quality to. Agilent

GC Injector Liners. Bruker Varian Agilent (HP) Perkin Elmer Finnigan. Phone: Page 4

GC Accessories. Solutions Guide. Liners Ferrules Cool-Lock Nut. Septa Vials Gold Seals

Microsep Low-Bleed PTFE-Lined Septa. XLB Septa

Copyright 2004 Alltech Associates, Inc.UNP. brochure #487K. accessories

Jaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Agilent GCs. Genuine Restek Replacement Parts. More Parts & Accessories for More GC Systems. Innovative Chromatography Products

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Technical Procedure for Gas Chromatography (GC-FID)

Phenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals

trace samples >2µL 4.0mm 6.5mm x 78.5mm accommodates more polar solvents and lower MW solvents 5.0mm 6.5mm x 78.5mm 2.0mm 6.5mm x 78.

GCMS-QP2010 Series. Consumables. Shimadzu Gas Chromatograph/Mass Spectrometer

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Genuine Restek Replacement Parts For Agilent 5890 GCs

CP-3800 GAS CHROMATOGRAPH

Analysis of Petroleum Fractions by ASTM D2887

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard

Thermo Scientific. TRACE GC Ultra. Gas Chromatograph Spare Parts Catalog. PN , Revision October 2011

GC Inlet Maintenance:

Agilent Multimode Inlet for Gas Chromatography

Agilent 7820A Gas Chromatograph

Using the PSD for Backflushing on the Agilent 8890 GC System

GC Inlets. An Overview. Simon Jones GC Applications Engineer

Installing the 6850 Direct Valve Column Connector Kit

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

PORTAFOLIO DE CROMATOGRAFÍA LABINS

Chromatography. Research Supplies. 2014/2015 Catalog

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA

Agilent 1290 Infinity Autosampler

Swagelok.

Shimadzu GCs. Genuine Restek Replacement Parts

Techniques for Improving the Reproducibility of GC Analysis

Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

For more information about Agilent Technologies services please visit our web site using the following URL

GC AND GC/MS. Your Essential Resource for Columns & Supplies

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust

CHROMATOGRAPHY TIME IN CONVENTIONAL GAS THE FASTEST INJECTION-TO-INJECTION CLARUS 680 GAS CHROMATOGRAPH NEW

260 Solvent Vapor Exit Accessory

Introducing Restek s most inert liner The Sky Inlet Liner! Chromatography Products.

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust

Quick Reference Guide. Supplies for Waters HPLC Systems

Set Your Sights on Superior Performance

Practical Steps in GC Troubleshooting

Agilent 7693A Automated Liquid Sampler

Thermo Scientific GCs

CHROMATOGRAPHY. SYKAM S 6000 Valve Series

Method Development for Capillary GC Systems. Slide 1

Hot Injection Adapter Kit - Installation Guide

Set Your Sights on Superior Performance

Agilent 7693A Automated Liquid Sampler

GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

Agilent SD-1 Purification System ml/min

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

GLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913

High-Performing Restek PAL SPME Fibers

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Application Note. Abstract. Authors. Environmental Analysis

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

Nickel Catalyst Tube Accessory 19205A

MET-Biodiesel Capillary GC Columns

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Typical Gas Chromatographic System

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Instrument Supplies. Instrument Supplies from the specialists in chromatography 233

Liquid Chromatography LC Consumables SSI-LC

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

The next level of True Blue Performance

SGE. Hamilton. Precision. Norm-Ject. NewERA SYRINGE PUMPS. Sampling glass microliter. Plastic Syringes. Stainless Steel. glass microliter.

Agilent 6850 Series II Network GC System G2630A Performance Specifications

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

Proof of Long-Term, Leak-Free Performance for a Novel Self-tightening GC Column Nut

Agilent Valve Kit G4231A/B/C and G4232B/C/D

S 1125 HPLC Pump System

Agilent G3348B Flame Photometric Detector

Analysis of Glycerin and Glycerides in Biodiesel (B100) Using ASTM D6584 and EN Application. Author. Abstract. Introduction

Agilent G3510A/G3511A Multimode Inlet

GC AND GC/MS. Your Essential Resource for Columns & Supplies

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Agilent Multimode Inlet

Performing ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software

Transcription:

Choose for Your Instrument GC Supplies - Agilent Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings and Sealing Rings SilTite FingerTite Ferrules Ferrules

Your chromatography analysis does not end with the selection of the GC column. The combination of components selected for your instrument also make an important contribution to successful separations. SGE brings technology and chromatography expertise to improve your chromatography. SGE Supplies for Sample Preparation, Sample Introduction, and Separation SAMPLE INTRODUCTION - Syringes Our involvement in all areas of chromatography provides us with a unique understanding of your requirements enabling us to optimize syringe design for sample introduction. All our syringes, both manual and autosampler, incorporate SGE s Diamond Syringe Technology offering significantly improved levels of durability, clarity and accuracy. SGE has a comprehensive range of syringe options including plunger protection, removable or fixed needles, a range of needle gauge and length options as well as needle-tip style alternatives. SAMPLE INTRODUCTION - Septa The role of septa for GC analysis is key as many chromatographic problems are caused as a result of inappropriate septa material or inappropriate handling of the septa. Desired septa attributes: Reliably seal against the carrier gas pressure in the inlet. Capable of being pierced and resealed time after time. Capable of being pierced by the syringe needle without pieces of the septa being deposited in the GC inlet system. Must not contaminate or bleed material into the chromatographic system. SAMPLE INTRODUCTION GC Inlet Liners The GC Inlet liner is where the sample is introduced and vaporized into the gaseous phase. The design of the liner is crucial, as is liner deactivation, to ensure reproducible and accurate chromatography. SEPARATION - GC Connections (ferrules and fittings) SGE manufactures an array of connection types for GC use. Poorly defined or selected connections can lead to an increase in dead volume, leaks from cycled temperatures and mismatched tubing sizes.

Instrument Quick Pick for Agilent Technologies Autosampler Syringes All needles are 42 mm long with a cone point. Agilent 7673, 7683, 7693A & 6850 ALS Volume Needle Gauge (OD mm) Syringe Code Syringe Part No. Pack Size Spare Needle Part No. Pack Size Spare Plunger Part No. Fixed Tapered Needle 5 µl 23-26s (0.63/0.47) 5F-AG-0.63/0.47C 001821 1 10 µl 23-26s (0.63/0.47) 10F-AG-0.63/0.47C 002821 1 10 µl Gas Tight 23-26s (0.63/0.47) 10F-AG-GT-0.63/0.47C 002826 1 031808 2 Fixed Straight Needle 5 µl 26 (0.47) 5F-AG-0.47C 001800 1 5 µl(m) 23 (0.63) 5F-AG-0.63C 001810 1 10 µl 26 (0.47) 10F-AG-0.47C 002800 1 10 µl(m) 23 (0.63) 10F-AG-0.63C 002810 1 10 µl(m) Gas Tight 23 (0.63) 10F-AG-GT-0.63C 002812 1 031808 2 Removable Tapered Needle 0.5 µl 23-26s (0.63/0.47) 0.5BR-AG-0.63/0.47C 000415 1 033730 1* 10 µl Gas Tight 23-26s (0.63/0.47) 10R-AG-GT-0.63/0.47C 002829 1 037730 2 031809 2 Removable Straight Needle 0.5 µl 26 (0.47) 0.5BR-AG-0.47C 000400 1 033708 1* 0.5 µl (M) 23 (0.63) 0.5BR-AG-0.63C 000410 1 033715 1* 1 µl 23 (0.63) 1BR-AG-0.63C 000610 1 034715 1* 10 µl 26 (0.47) 10R-AG-0.47C 002805 1 037715 2 10 µl (M) 23 (0.63) 10R-AG-0.63C 002815 1 037717 2 (M) Suitable for use with the Merlin Microseal Injector. * Denotes Spare Needle and Plunger kit. Pack Size Septa SGE has a number of different septa materials: GP = For non-demanding routine applications. EC = Combines significantly longer injection life, low bleed and low injection port adhesion. MN = Premium septa for autosamplers, up to 400 injection per septum. HT = Bleed and temperature optimized, combined with outstanding mechanical properties. Type Material Durability Resealing Solvent Resistance Tear Resistance Maximum Temperature GP Silicone Good Good Excellent Good 200 C EC High Temperature Silicone Excellent Excellent Excellent Excellent 400 C MN High Temperature Silicone Excellent Excellent Excellent Excellent 400 C HT BTO Silicone Excellent Excellent Excellent Excellent 400 C Diameter (mm) Material Pack Size Part No. For Agilent 7620, 5790, 5880, 5890 5 GP 50 041820 5 MN 50 041850 For Agilent 5700, 5800, 5900 9.5 GP 50 0418240 9.5 EC 25 041901 9.5 HT 50 041897 For Agilent 7890, 6890,5890, 5880, 4890, 6850 11 GP 50 041826 11 EC 25 041902 11 MN 50 041856 11 HT 25 041898 For Agilent 5750, 710, 720, 810, 7610 12.5 GP 48 041828 12.5 HT 24 0418992 12.5 EC 24 041906

Inlet Liners Description and Geometry Sketch OD (mm) ID (mm) For Agilent 5890, 6850, 6890, 7890 and HP4890 Length (mm) Split / Splitless FocusLiner Split / Splitless Tapered FocusLiner Split / Splitless FAST FocusLiner 6.3 2.3 78.5 Split / Splitless Tapered FAST FocusLiner 6.3 2.3 78.5 Pack Size Part No. 5 092002 25 092219 5 092003 25 092011 5 092005 25 092008 5 092111 25 092115 ConnecTite Liner Standard ConnecTite Liner Top Hole ConnecTite Liner Bottom Hole Split, Straight-through Liner Split, with Quartz Wool Split / Splitless with Single Taper Split / Splitless with Single Taper (Quartz Wool) Split / Splitless with Double Taper Direct, Straight-through Liner Split / Splitless Quartz, Straight-through Liner Splitless with Recessed Gooseneck Split / Splitless Recessed Gooseneck (Quartz Wool) 5 092324 5 092325 5 092326 5 092007 25 092222 5 092001 25 092220 5 092017 25 092229 5 092019 25 092218 5 092018 25 092230 5 092016 6.3 1.2 78.5 25 092224 6.1 2 78.5 5 092004 6.3 2 78.5 5 092013 5 092010 25 092223 O-rings and Sealing Rings Description Usage Pack Size Part No. Viton O-ring Graphite Sealing Ring Graphite Sealing Ring Can be used at temperatures up to 300 C. Suitable for liners with OD of 6.3 mm. Can be used at temperatures up to 450 C. Suitable for all inlet liners above except 092004 and 09200401. Can be used at temperatures up to 450 C. Suitable for use with liners 092004 and 09200401. 10 0726532 10 0726005 10 0726006

SilTite FingerTite Ferrules Description Pack Size Part No. SilTite Fingertite Agilent INJ / FID Starter Kit * 073610 SilTite Fingertite Agilent INJ / MS Starter Kit * 073612 SilTite Fingertite Ferrule 0.4 mm Replacement Items 10 073630 SilTite Fingertite Ferrule 0.5 mm Replacement Items 10 073631 SilTite Fingertite Blanking Ferrule Replacement Items 2 073633 SilTite Fingertite Female Nut Replacement Items 5 073636 SilTite Fingertite Agilent INJ Base Seal Replacement Items 2 073640 SilTite Fingertite Starter Kit 0.4 # 0736100 SilTite Fingertite Agilent Capillary Adaptor 1 0736101 SilTite Fingertite Agilent MS Adaptor 1 0736102 SilTite Fingertite Agilent FID Detector 1 0736103 SilTite Fingertite Agilent Injector 1 0736104 SilTite Fingertite Starter Kit 0.5 # 0736105 * Each starter kit includes all the parts necessary to convert one GC system (one injector and one detector) to the SilTite FingerTite system suitable for installing 0.1 0.25 mm ID capillary columns. In addition there are five SilTite FingerTite nuts, one packet (ten ferrules) of 0.4 mm ID SilTite FingerTite ferrules and a ferrule install tool which allows you to seat the ferrule in the correct position on the capillary column. # 0.4 and 0.5 Starter Kits include ten ferrules for either 0.1-0.25 mm ID capillary columns (0.4) or 0.32 mm ID capillary columns (0.5) plus five SilTite FingerTite nuts and the ferrule install tool. Ferrules Instrument Column ID Ferrule ID Pack Size Part No. 15% Graphite / 85% Vespel Ferrules 0.1-0.25 mm 0.4 mm 10 073109 0.32 mm 0.5 mm 10 073111 For Injectors & Detectors at atmospheric pressure e.g. FID 0.53 mm 0.8 mm 10 073113 for 1/8" OD Packed Columns 1/8" 10 072669 for 1/4" OD Packed Columns 1/4" 10 072667 0.1-0.25 mm 0.4 mm 10 072663 For GC-MS Interface Connection 0.32 mm 0.5 mm 10 072654 0.53 mm 0.8 mm 10 072655 100% Graphite Ferrules 0.1-0.32 mm 0.5 mm 10 072635 Injectors & Detectors at atmospheric 0.45-0.53 mm 0.8 mm 10 072636 pressure e.g. FID (Not for GC-MS) for 1/8" OD Packed Columns 1/8" 10 072602 for 1/4" OD Packed Columns 1/4" 10 072601 SilTite Metal Ferrules 0.1-0.25 mm 0.4 mm 10* 073200 For GC-MS Interface Connection (Starter Kit) 0.32 mm 0.5 mm 10* 073201 0.53 mm 0.8 mm 10* 073202 0.1-0.25 mm 0.4 mm 10 # 073270 For Split / Splitless Injectors (Starter Kit) 0.32 mm 0.5 mm 10 # 073271 0.45-0.53 mm 0.8 mm 10 # 073272 1/32" 0.81 mm 10 # 073273 Replacement SilTite Metal Ferrules 0.1-0.25 mm 0.4 mm 10 073220 For All Connections 0.32 mm 0.5 mm 10 073221 0.53 mm 0.8 mm 10 073222 1/32" 0.81 mm 10 073219 Replacement SilTite Nuts For GC-MS Interface Connection _ 5 073224 For Split / Splitless Injector _ 5 073226 Replacement SilTite Base Seals For Split / Splitless Injector _ 2 073400 _ 10 073401 * Includes ten ferrules, two SilTite nuts. # Includes ten ferrules, two SilTite nuts and two SilTite Inlet Base Seals.

SGE's involvement in gas chromatography includes the support we give to our customers. Technical Support Contact us at techsupport@sge.com for technical support information. Our Website www.sge.com is a detailed source for information on chromatography, applications and SGE products. It also profiles the latest posters and materials developed by our technical experts based around the world. SGE Product Selection Guide Our product selection guide can be accessed at www.sge.com/selectionguide BR-0371-C_RevE SGE Analytical Science Pty Ltd 07/2013 AUSTRALIA AND PACIFIC REGION SGE Analytical Science Pty Ltd Toll Free: 1800 800 167 Tel: +61 (0) 3 9837 4200 Fax: +61 (0) 3 9874 5672 Email: support@sge.com JAPAN SGE Japan Inc Tel: +81 (0) 45 222 2885 Fax: +81 (0) 45 222 2887 Email: japan@sge.com EUROPE SGE Europe Ltd Tel: +44 (0) 1908 568 844 Fax: +44 (0) 1908 566 790 Tel France: +33 (0) 1 69 29 80 90 Tel Germany: +49 (0) 6155 / 60746 0 Email: europe@sge.com UNITED STATES OF AMERICA SGE Inc Toll Free: 800 945 6154 Tel: 512 837 7190 Fax: 512 836 9159 Email: usa@sge.com