Catapult 1000 Series Instruction Manual

Similar documents
Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Valor 2000 Series Instruction Manual

Defender 3000 Series Base Instruction Manual

Ohaus ES Series Bench Scale

Navigator TM Series Balances Instruction Manual

Compact Scales. Software Revision V1.25 & above

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

SPC Series. Digital Scale. Operation Manual

Washdo. wn Scale Base

Scout TM Series Balances - SKX Instruction Manual

SSP-Series Portable Balances Operation Manual

Scout Series Balances - SPX Instruction Manual

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

Adam Equipment LHS SERIES. (P.N , Revision A March 2012)

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

SHS/SHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version S1.1/SA1.1

DC 5000 Series Crane Scale Instruction Manual

Adam Equipment. CB Balance. (P.N Revision B1, Apr 2014)

HARVARD TRIP BALANCE Series 1400 and 1500 Instruction Manual

Quick Guide. brite Advanced Retail scale

Adam Equipment CPW COMPACT SCALE

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

LHS/LHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version L1.1/LA1.1

User s Manual Chase on the Case Cruiser

Adam Equipment MIW-20 BABY SCALE. ADAM EQUIPMENT CO. LTD. p.n. 4295, Rev. B, March 2004

Model DS7060 Handrail Scale. User Manual

User s Manual Pups to the Rescue Driver

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

Model 594KL Digital Chair Scale

HS SERIES ELECTRONIC HANGING SCALE CONTENTS OPERATION MANUAL 1. OPERATING PRECAUTIONS 2. KEYBOARD LAYOUT AND DESCRIPTION 3. INSTRUCTIONS FOR USE

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

This manual covers the following model:

Price Computing Scale D Series Operation Manual

Powerware Vdc Extended Battery Cabinet User s Guide.

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

Thermistor Thermometer MODEL NO

ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL

SCALIX MULTIPURPOSE SCALES SCALIX COMPACT SCALE FKS-600 FKS-6000 INSTRUCTION MANUAL

Please read and understand all precautions prior to use.

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

i3000s/i2000 Flex AC Current Probe

IAQ-CALC TM Indoor Air Quality Meter

GRAVITY MEASUREMENT, INC.

User Manual Pocket Pro, Pro + ph

2800 OPERATING INSTRUCTIONS

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Barnant Company (Type J) (Type K) (Type T)

Go! Go! Smart Friends

Crane Scale. NC Series OWNER S MANUAL

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

NCSA 20plus Service Manual

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

Switching DC Power Supply

362 Clamp Meter. Users Manual

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

OWNER S MANUAL Please read and understand all precautions prior to use.

Balanzas de la gama Scout TM SJX Series Manual de Instrucciones

Indoor Air Quality Meter

IAQ-CALC TM Indoor Air Quality Meter

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

OPERATING INSTRUCTIONS

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

BATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL

DSP led gaming monitor USER MANUAL

User s Guide. EZ-Bar Livestock Scale WEIGH BARS AND DIGITAL INDICATOR. WB-40 Weigh Bars TS-700 WB Digital Indicator. Guide version 1.

User s Manual. Deluxe Car Carrier TM VTech Printed in China

Operator s Manual TC-253A. Temperature Converter

User s Manual. Carina s Mini Golf & Check-Up Table VTech Printed in China US

Price Computing Scale DS Series Operation Manual

MODEL PS-4 DIGITAL PORTION SCALE

MQ4C-24/6485 WIRELESS INDOOR/OUTDOOR QUAD-COPTER

SERVICE MANUAL Valor 1000 Scales

Operating instructions Platform/floor scales

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

Patient Lift Scale Indicator Owner s Manual

Auto-Off & Power Hold Function

User Guide. Digital Shipping Scale S150

Go to to register your product and find more information.

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

User s Manual. 3-in-1 Launch & Play Raceway TM VTech Printed in China

Digital Clock model 75100C

WARRIOR SERIES USER MANUAL

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

HIGH VOLTAGE PROVING UNIT

i400s Calibration Information Introduction

pro user guide 940H Student Microphone 940C Microphone Charger

PEDIATRIC SCALE. Models 459-CH, 8432-CH and 8432-CHKGEU Owner s Manual

PORT-A-WEIGH CRANE SCALES

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

712 RTD Calibrator. Instruction Sheet. Introduction

Transcription:

TM Catapult 1000 Series Instruction Manual

Catapult 1000 Series Scales EN-1 1. INTRODUCTION This manual contains installation, operation and maintenance instructions for the TM Catapult 1000 Series Scales. Please read the manual completely before using the scale. 1.1 Safety Precautions Please follow these safety precautions: Verify that the AC Adapter input voltage matches the local AC power supply. Do not immerse the scale in water or other liquids. Do not operate the scale in hostile environments. Do not drop loads on the platform. Do not place the scale upside down on the pan. Service should only be performed by authorized personnel Disconnect the scale from the power supply when cleaning 1.2 Controls Figure 1-1. Controls.

EN-2 Catapult 1000 Series Scales TABLE 1-1. CONTROL FUNCTIONS. Button Primary Function (Short Press) Secondary Function (Long Press) ON/ZERO Turns scale ON. If scale is On: Sets zero. Simulates a tare operation. Off Turns scale off. UNITS Changes the weighing unit. Enters Dynamic Weighing Mode. Initiates countdown in Dynamic Weighing mode. Cal Initiates calibration process. 1.2 Display Window 1.2.1 Large 7-Segment Numeric Characters: Weight (mass) values are shown using 4 digits including negative sign and decimal places. Prompts for calibration and possible error conditions are also shown using these digits. 1.2.2 Stable Reading Indication: A * will appear in the lower left corner of the display to indicate when the reading is stable. 1.2.3 Weighing Unit Indication: The weighing unit selected appears on the right side of the display 1.2.3 Dynamic Weighing Mode Indication: A will flash next to the selected unit during this mode. 1.2.3 Low Battery Indication: The battery symbol on the left side of the display indicates a low battery condition. When first displayed, approximately 12 hours of operation remain. When the battery is fully depleted, the scale will momentarily display Lo bat and shut off.

Catapult 1000 Series Scales EN-3 2. INSTALLATION 2.1 Package Contents Scale Power Adapter Instruction Manual Warranty Card 2.2 Location Use the scale on a firm, steady surface. Avoid locations with excessive air current, vibrations, heat sources, or rapid temperature changes. 2.3 Power 2.3.1 AC Power The AC adapter (included) may be used to power the scale when battery power is not available. Connect the AC adapter plug to the input jack. Then plug the AC adapter into a properly grounded power outlet. Figure 2-1. Power Connection.

EN-4 Catapult 1000 Series Scales 2.3.2 Battery Installation (Optional) Open the battery cover on the bottom of the scale and install three C size (LR14) alkaline or rechargeable batteries into the compartment. Orient the batteries as shown on the inside of the compartment. Close the battery cover. NOTE: Batteries are not included. Figure 2-2. Battery Installation. CAUTION: Do not dispose of used batteries in domestic waste. Follow the proper disposal or recycling requirements in accordance with local laws and regulations. 3. OPERATION 3.1 Turning Scale On/Off To turn the scale on, press the ON/ZERO Off button. The scale performs a display test, momentarily displays the model/software version, and then enters the active weighing mode. To turn the scale off, press and hold ON/ZERO Off button until OFF is displayed. 3.2 Zero Operation By pressing the ON/ZERO Off button, the scale display returns to zero. When adding additional mass, the ON/ZERO Off Button may be used repeatedly until the full capacity of the scale is reached. When a container is used, the ON/ZERO Off button may be used to simulate a Tare function. Additional mass may then be added as a

Catapult 1000 Series Scales EN-5 NET weight. When removing both the sample and container from the scale, a negative value may be displayed. Zero the scale again before subsequent usage. NOTE: The ON/ZERO Off button will perform a true zero setting function when displayed values are within +2% of full capacity. Above 2%, the range is limited to full capacity by subtraction. 3.3 Changing Units of Measure Press the UNITS Cal button to display the next available measuring unit. 3.4 Auto Shut-Off To extend battery life, the scale will automatically turn off after approximately four minutes of inactivity. This feature is only active during battery operation. 3.5 Dynamic Weighing With the platform empty, short press the UNITS Cal button to cycle through the units. Dynamic mode is active when the indicator is flashing. Place a mass on the platform. The scale will show -A-. NOTE: If using a container, press ON/ZERO Off to tare the weight and return to zero. With a mass on the platform or container, a short press of UNITS Cal will start the averaging countdown from 5 seconds. The averaged weight is then displayed. The indicator stops flashing when the process is complete. The display will hold until a button is pressed. To repeat the process press UNITS Cal with a mass on the platform or container. To Exit, remove the mass from the platform or container and press UNITS Cal.

EN-6 Catapult 1000 Series Scales 4. CALIBRATION For best results, calibrate the scale at regular intervals. (Calibration weights are not supplied with the scale.) CAUTION USE EXTREME CARE WHEN HANDLING CALIBRATION WEIGHTS AS THEY ARE VERY HEAVY. IMPROPER LIFTING METHODS OR MISUSE OF CALIBRATION WEIGHTS MAY RESULT IN PERSONAL INJURY. MULTIPLE WEIGHTS MAY BE USED TO EQUAL THE REQUIRED CALIBRATION WEIGHT NOTE: Ensure the appropriate calibration masses are available before beginning calibration (see Table 4-1). Ensure that the scale is level and stable during the entire calibration process. Calibration is unavailable in Dynamic Weighing Mode. Allow the scale to warm up for at least 2 minutes after stabilizing to room temperature. To abort calibration, press UNITS Cal, or power off the scale. TABLE 4-1. CALIBRATION WEIGHTS. Model Calibration weight (kg/lb) C11P9 9 / 20 C11P20 20 / 40 C11P75 50 / 100 4.1 Span Calibration Span Calibration uses two points to adjust the scale. The first point is the zero value where there is no weight on the scale. The second point is the Span value where a calibration mass is placed on the scale. To select the weighing unit to be used for calibration, press the UNITS Cal button until the correct unit is displayed. Press and hold the UNITS Cal button until CAL is displayed.

Catapult 1000 Series Scales EN-7 With the platform empty, press the ON/ZERO Off button to capture the scale zero. The display will show -C-. After the zero is captured, the required span calibration weight in the selected unit is displayed. Place the calibration weight on the platform and press ON/ZERO Off button. The display will again show -C-. After span capture, the display will return to the normal weighing mode. NOTE: The message CAL E will appear if an incorrect calibration weight was applied. Repeat the procedure using the correct calibration weight. 4.2 Calibration Locking By use of an internal switch, the calibration function may be locked (disabled), and unauthorized recalibration prevented. With the scale powered off, remove the cover under the indicator by unscrewing the two screws at the bottom. Slide the switch on the PCB (marked SW3) to the position marked CAL LOCK. Reassemble the cover. If required, place tamper evident sealing labels over the screw holes or over the housing edges. If later recalibration is required, the cover will need to be reopened and the lock switch returned to the original position. NOTE: When the lock switch is set to the CAL LOCK position, the power-on zero range is reduced to 10% of full capacity.

EN-8 Catapult 1000 Series Scales 5. MAINTENANCE Caution: before cleaning, turn off the scale, and remove the AC adapter. 5.1 Cleaning The housing may be cleaned with a cloth dampened with a mild detergent if necessary. Do not use solvents, chemicals, alcohol, ammonia or abrasives to clean the housing or control panels. 5.2 Troubleshooting The following table lists common problems and possible causes and remedies. If the problem persists, contact Ohaus or your authorized dealer. TABLE 5.1. TROUBLESHOOTING. Symptom Possible Cause(s) Remedy Scale will not turn on No power to scale Battery power used up Verify connections and voltage. Verify battery polarity Poor accuracy Unable to calibrate Scale displays Lo bat Scale displays Lo Line Scale displays E Improper calibration. Unstable environment CAL LOCK set to ON Unstable environment Incorrect calibration mass Battery is discharged Low Line voltage Weight on pan exceeds capacity Perform calibration. Move scale to suitable location Set CAL LOCK to OFF (see section 4.2) Move the scale to suitable location Use correct calibration mass Connect power or change the batteries Verify source voltage Remove weight from the pan Scale displays CALE Incorrect Calbiration weight on pan Scale displays UnSt Scale is unstable at power up. Use correct calibration weight Relocate scale to a more stable environment

Catapult 1000 Series Scales EN-9 5.3 Service Information If the troubleshooting section does not resolve or describe your problem, contact your authorized Ohaus service agent. For service assistance or technical support in the United States call toll-free 1-800-526-0659 between 8.00 AM and 5:00 PM EST. An Ohaus product service specialist will be available to provide assistance. Outside the USA, please visit our web site, www.ohaus.com to locate the Ohaus office nearest you. 6. TECHNICAL DATA The technical data is valid under the following ambient conditions: Ambient temperature: 5 C to 40 C / 41 to 104 F Relative humidity: 10% to 80% relative humidity, non-condensing 6.1 Specifications TABLE 6-1. SPECIFICATIONS. Model C11P9 C11P20 C11P75 Capacity x Readability 9 kg x 0.005 kg 20 kg x 0.01 kg 75 kg x 0.05 kg 20 lb x 0.01 lb 44 lb x 0.02 lb 165 lb x 0.1 lb Weighing Units kg, lb Modes Simple Weighing, Dynamic Weighing Keypad 2-button mechanical keys Calibration Weights 9 kg / 20 lb 20 kg / 40 lb 50 kg / 100 lb Display 4-digit 7-segment, 20mm / 0.8 in characters Display Indicators Stability, weighing unit, dynamic weighing, battery status Tare range To capacity by subtraction Stabilization Time 3 seconds Maximum Overload 150% Operating temperature/humidity range 5 to 40 C / 41 to 104 F at 10% to 80% relative humidity, non-condensing Power Requirements 9-12 VDC 100mA AC Adapter (supplied) 3 C Alkaline or rechargeable batteries (LR14) optional Auto Shut-Off 4 minutes no activity (battery operation only) Typical Battery life 300 hours Scale Dimensions (mm / in) 316 x 316 x 60/ 12.4 x 12.4 x 2.36

EN-10 Catapult 1000 Series Scales 6.2. Drawings and Dimensions Figure 6-1. Catapult 1000 Series Overall Dimensions.

Catapult 1000 Series Scales EN-11 6.3. Compliance Compliance to the following standards is indicated by the corresponding mark on the product. Mark Standard This product conforms to the EMC directive 2004/108/EC and the Low Voltage Directive 2006/95/EC. The complete declaration of Conformity is available from Ohaus Corporation AS/NZS4251.1 Emission; AS/NZS4252.1 Immunity Disposal In conformance with the European Directive 2002/96 EC on Waste Electrical and Electronic Equipment (WEEE) this device may not be disposed of in domestic waste. This also applies to countries outside the EU, per their specific requirements. Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment. If you have any questions, please contact the responsible authority or the distributor from which you purchased this device. Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. Thank you for your contribution to environmental protection.

EN-12 Catapult 1000 Series Scales FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Industry Canada Note This Class B digital apparatus complies with Canadian ICES-003. ISO 9001 Registration In 1994, Ohaus Corporation, USA, was awarded a certificate of registration to ISO 9001 by Bureau Veritus Quality International (BVQI), confirming that the Ohaus quality management system is compliant with the ISO 9001 standard s requirements. On May 15, 2003, Ohaus Corporation, USA, was re-registered to the ISO 9001:2000 standard. LIMITED WARRANTY Ohaus products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period. During the warranty period Ohaus will repair, or, at its option, replace any component(s) that proves to be defective at no charge, provided that the product is returned, freight prepaid, to Ohaus. This warranty does not apply if the product has been damaged by accident or misuse, exposed to radioactive or corrosive materials, has foreign material penetrating to the inside of the product, or as a result of service or modification by other than Ohaus. In lieu of a properly returned warranty registration card, the warranty period shall begin on the date of shipment to the authorized dealer. No other express or implied warranty is given by Ohaus Corporation. Ohaus Corporation shall not be liable for any consequential damages. As warranty legislation differs from state to state and country to country, please contact Ohaus or your local Ohaus dealer for further details.

Ohaus Corporation 19A Chapin Road P.O. Box 2033 Pine Brook, NJ 07058-2033, USA Tel: (973) 377-9000 Fax: (973) 944-7177 With offices worldwide / Con oficinas alrededor del mundo / Avec des bureaux dans le monde entier / Weltweite Geshäftsstellen / Con uffici in tutto il mondo. www.ohaus.com *80250426* P/N 80250426 B 2008 Ohaus Corporation, all rights reserved / todos los derechos reservados / tous droits réservés / Alle Rechte vorbehalten / tutti i diritti riservati. Printed in China / Impreso en la China / Imprimé en Chine / Gedruckt in China / Stampato in Cina