Daikin Steam Coils. Installation and Maintenance Manual IM 901. Types HI-F5, HI-F8, & E-F5. Group: Applied Air. Part Number: IM 901

Similar documents
Fluid Coil Installation, Operation and Maintenance

Nomenclature. Nomenclature Distributing coil types

Steam Coils. Connections. Vents & Drains. Standard on all coils

Standard Service / Installation / Operation Manual Type W & P Water / Glycol Heat Transfer Coils

VIFB Coil Technical Guide

Complete HVAC Capability

Tech Brief - Steam Coil Considerations. Tech Brief: Coils Series. Steam Coil Designs

INSTALLATION MANUAL TBH/TBV BELT DRIVE BLOWER-COIL UNITS HORIZONTAL. Redefine your comfort zone.

CUSTOMER S MANUAL. Coil models FV,FK,FH,FC,FD,FP,FS TV,TK,TC,TD

Generator and Motor Coolers

Owner s Information Manual

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

Geo-Prime Tank. Table of Contents. Installation, Operation & Maintenance Instructions AFCG1PT Revision: 7/3/14. Replacing a Pump 12

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

MODEL CJ-95 CoilJet Portable HVAC Coil Cleaning System

Design Factors for Steam Coils

Geo-Prime Tank U.S. Patent Number 8,544,282

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

FABER BURNER ROUTINE MAINTENANCE

Fluid Coils. Desaturation Coils. Hot Water Coils

Manufacturer Kakogawa, Japan DC5S

Installation Manual DIAPHRAGM WELL TANK

NECO Pumping Systems

McQuay MDM Air Handling Unit CMDM

Suzuki Samurai Coated Stainless Steel Braided Brake Lines (SKU# SB-BL) Installation Instructions

Secondary Coolant 301

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

OPERATION & MAINTENANCE INSTRUCTION MANUAL

Fluid Coils. Desaturation Coils. Hot Water Coils

Owner s Manual GLASSLINED PUMP TANK

INSTRUCTION MANUAL AND PARTS LIST FOR 3E CANNED MOTOR PUMPS

MSC Manifolds - DIN for Steam Distribution and Condensate Collection Installation and Maintenance Instructions

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

Installation Instructions

Installation Instructions

Air-Cooled Screw Compressor Chiller

PRESSURIZED DIATOMACEOUS EARTH FILTER SYSTEM

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

General Installation Instructions for Valves and Gates

INSTALLATION INSTRUCTIONS

BAC / BHC Product Specifications

Swing Piston Compressors and Vacuum Pumps

GL Ludemann Y-Strainers

M-3025CB-AV Fuel Pump

INSTRUCTION AND REPAIR MANUAL MODELS 341A, 342A AND 344A 6

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

Installation, Operation, and Maintenance Manual

J-1 RELAY VALVE, Part No J-1 RELAY VALVE PORTION, Part No

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

COLDFUSION. Operator s Manual

Instructions for Installing and Operating Clark Reliance EA100 Series Levalarm

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

Addendum. Remote Air-Cooled Condenser

Free Float Air Trap G8

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

INSTALLATION GUIDE CR SERIES - DEDICATED HORIZONTAL COIL ! WARNING. 1. Safety Instruction. 2. Inspection. 3. Installation Preparation

TYPE E Main Valve Sizes 3 /8 through 12

Installation Instructions

1/2" AIR DRIVEN DIAPHRAGM PUMP

High Lift Flange Weld/Test Plug (3/4"-8") - Technical Specifications

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

UAHT BRAKE CYLINDERS. operation & maintenance instruction , S.12 NOVEMBER, Supersedes issue dated November, 1986

Model DF233 Control Valve

SUNC3000 / Item #40885

Butterfly valves Figure 56 Installation & Maintenance Instructions

Operation and Maintenance Manual. for Fiberglass Tanks

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

CALIPER BRAKE INSTALLATION AND MAINTENANCE MANUAL

Operating and installation instructions

Crispin Valves Operating Guide. Crispin

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

Installation, Operation, and Maintenance Manual

Installation & Design Maintenance for ILBP System

WARCO CHEMAG SERIES GH FILTERS

Toyota Tundra Sequoia Differential Drop Kit by Low Range Off-Road (SKU# LR-TUNDDK)

WARNING. Before the exhaust silencer is fitted to the pump, the pump must be secured as describe in the pump manual. WARNING

This information covers the proper procedure for replacing the Volvo D16F engine in a VT or VNL chassis.

Designed to provide maximum service life with minimum maintenance.

Two Stage Rotary Vane Vacuum Pumps Operation and Maintenance Manual

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

SECTION TWO MOUNTING INSTRUCTIONS

SECTION AXIAL HVAC FANS

Installation and Maintenance Manual CEMLINE CORPORATION

Climas y Proyectos Leyco, S.A. de C.V.

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

Valveworks USA Operation and Maintenance Booklet Model FC

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12)

OPERATION INSTRUCTIONS

Suspension System RS66102B

Transcription:

Installation and Maintenance Manual IM 901 Daikin Steam Coils Group: Applied Air Part Number: IM 901 Date: February 2008 Types HI-F5, HI-F8, & E-F5 2008 Daikin Applied

Contents Introduction... 3 General Information... 3 Hazard Identification Information... 3 Receiving Instructions... 3 Coil Types... 3 Distributing... 3 Single Tube... 3 Nomenclature... 4 Installation... 5 Mounting... 5 Installation... 5 Operation and Maintenance... 8 Operation... 8 General... 8 Maintenance... 8 General... 8

Introduction Introduction General Information These are general guidelines for the installation, operation and maintenance of Daikin steam heating. They may have to be tailored to meet the specific requirements of any one job. An experienced installation company or fully trained personnel should perform the installation and maintenance of any coil. Hazard Identification Information DANGER Dangers indicate a hazardous situation which will result in death or serious injury if not avoided. WARNING Warnings indicate potentially hazardous situations, which can result in property damage, severe personal injury, or death if not avoided. CAUTION Cautions indicate potentially hazardous situations, which can result in personal injury or equipment damage if not avoided. Receiving Instructions 1 Coils should be inspected for shipping damage upon receipt. The freight bill should also be checked against items received for complete delivery. 2 Damaged and/or missing items should be noted on the carrier's freight bill and signed by the driver. 3 Coils are factory tested at 315 psig (minimum air pressure) while submersed in water. 4 For additional assistance, contact your local Daikin sales representative. Coil Types Distributing Daikin models JA, RA and DA jet-tube steam distributing coils (Figure 1) are excellent for any general purpose heating application. With the superior freeze resistance provided by the tube-with-in-a-tube construction, it is ideal for low temperature preheating and special process applications. The construction features inner tubes with directional orifices to aid in steam distribution and condensate removal. Model JA offers same-end supply and return connections. Model RA offers opposite-end supply and return connections. Model DA offers dual-supply opposite-end connections for long coils that see sub-freezing air temperatures. Models GA, TA and LA utilize cupro-nickel, carbon steel and stainless steel tubing for high-pressure construction. Single Tube Daikin model SA steam coils (Figure 1) are designed for general purpose heating. The construction features a single tube design with opposite-end supply and return connections. A perforated baffle located directly behind the supply connection insures proper steam distribution. Model HA utilizes cupro-nickel, carbon steel and stainless steel tubing for high-pressure construction. Figure 1: Coil Types 5R 5T 5J 5G 5S 5H Daikin IM 901 3

Introduction Nomenclature 5 SA 12 01 C 24.00 x 110.00 Tube O.D. 8=1" 5=5/8" Coil Type 5SA: single tube, opposite end connection 5JA, 8JA: distributing tube, same end connection 5DA, 8DA: distributing tube, dual supply, opposite end connection 8RA: distributing tube, opposite end connection 5HA: high-pressure construction single tube, opposite end connection 5GA, 8GA: high-pressure construction distributing tube, same end connection 5LA, 8LA: high-pressure construction dual supply, opposite end connection 8TA: high-pressure construction distributing tube, opposite end connection 5SB: single tube, 3" center to center opposite end connection Finned Length (inches) Finned Heigth (inches) Fin Design A - flat (AI, Cu) B - corrugated (AI, Cu) C - sine wave (AI, Cu) F - flat (SS, CS) G - corrugated (SS, CU) H - sine wave (SS, CU) Rows Deep Fins Per Inch 4 Daikin IM 901

Installation Installation Mounting Steam coils must be properly mounted for condensate removal. This will aid in preventing destructive water hammer, keeping coils from freezing and preventing corrosive elements from collecting in the tubes. Case-pitched coils (Figure 2) should be installed level. Daikin models SA, SB, HA, JA, GA, DA, LA, RA and TA come standard pitched in the casing. Coils that are un-pitched (Figure 3) must be installed with the tubes pitched towards the return connection. A minimum pitch of 1/8 per foot of coil length is required (pitch has been exaggerated in Figure 3). Coils with opposite end connections (RA, TA, SA, & HA) should be furnished with an expansion joint or provisions made for expansion on opposite connection end. Figure 2: Case Pitched Installation WARNING Steam, even at low pressure, can cause serious bodily injury that may result in death. Be sure the system is off or the components are isolated before beginning work.. CAUTION Sharp edges on sheet metal and fasteners can cause personal injury. This equipment must be installed, operated, and serviced only by an experienced installation company and fully trained personnel. Protective equipment such as safety glasses, steel toe boots and gloves are recommended during the installation and routine maintenance of the coil. CAUTION Failure to properly install the coil can result in irreparable damage to the coil as well as other components in the system. Figure 3: Case Unpitched If you are unsure about any portion of the installation, contact your local steam specialist for assistance. 1 Carefully remove the coil from the shipping package to avoid damage to the finned surface area. Damaged fins can be straightened using an appropriate fin comb. 2 Daikin recommends cleaning the coil with a commercially available coil cleaner prior to installation. Refer to Operation and Maintenance on page 8 for cleaning recommendations. Note: Vacuum breakers and air vents should be piped to a drain or other suitable location where discharged steam cannot lead to personal injury. 3 Mount coil properly to provide positive condensate drainage. Refer to Mounting on this page. 4 Proper clearance should be maintained between the coil and other structures such as the fan, filter racks, transition areas, etc. 5 Utilize vacuum breakers on each coil. Steam traps require a positive pressure differential to force the condensate through the valve seat. If the coil's pressure drops below atmospheric, the pressure differential across the valve will be negative and the condensate will not drain. This condition can lead to serious damage or failure of the coil due to freezing, water hammer and corrosion. Refer to Figure 4 and Figure 5 for recommended placement. Daikin IM 901 5

Installation Figure 4: Low Pressure Steam Coil Piping Diagram SYMBOLS FOR PIPING ARRANGEMENTS LOW PRESSURE (TO 25 PSI) *5JA or 8JA coil installed with tubes vertical. The coil supply piping must be dripped ahead of the coil on an installation of this type. *5SA coil installed for vertical airflow. Installer must pitch coil toward the return connection on vertical airflow installations. For horizontal airflow installation, the required pitch is built into the casing. * NOTE: Rating data is ARI certified only for the standard ARI coil orientation; i.e., horizontal tubes, vertical coil face and horizontal airflow. 5JA or 8JA coil installed in series. Note that each coil must have a separate control valve and trap. 8RA and 5SA coils banked three high by three deep. Individual trapping of each coil as shown is preferred. Note that it is necessary to provide a separate control valve for each bank in the direction of airflow. *5SA coils installed with tubes vertical. Diagram shows single trap; however, it is always preferable to trap each coil individually. * NOTE: Rating data is ARI certified only for standard ARI coil orientation; i.e., horizontal tubes, vertical coil face and horizontal airflow. 6 Daikin IM 901

Installation Figure 5: High Pressure Steam Coil Piping Diagram SYMBOLS FOR PIPING ARRANGEMENTS HIGH PRESSURE (OVER 25 PSI) 5GA or 8GA coils. Note the addition of a vacuum breaker to permit the coil to drain during shutdown. 8TA or 5HA coils. Condensate is lifted to overhead return main. 6 Trap each coil separately. Differences in pressure from coil to coil can result in the backing-up of condensate that will result in poor coil performance and possible damage. 7 Provide an air vent for each coil at its highest location. Non-condensable gasses present in the steam will collect in a coil and reduce its capacity. Therefore, it is necessary to provide a means for the removal of these gasses. Also, these gasses can diffuse into the condensate forming biproducts, which can lead to severe corrosion. 8 Steam supply lines need to be drained of condensate. This can be accomplished by the use of drip legs. This ensures that high quality steam enters the coil. 9 Condensate return piping should be the same size as the coil's return connection from the coil outlet to the steam trap. 10 Once installed, the coil should be pressurized to 100 psig with dry nitrogen or other suitable gas. The coil should be left pressurized for a minimum of 10 minutes. If the coil holds the pressure, the hook-up can be considered leak free. If the pressure drops by 5 psig or less, re-pressurize the coil and wait another 10 minutes. If the pressure drops again, there are more than likely one or more small leaks, which should be located and repaired. Pressure losses greater than 5 psig would indicate a larger leak, which should be isolated and repaired. Be sure to check valves and fittings as potential sites for leakage or bleed. If the coil itself is found to be leaking, contact your local Daikin representative. Note: Unauthorized repair to the coil may void the coil's warranty (see Daikin's warranty policy on back cover). 11 All field brazing and welding should be performed using high quality materials and an inert gas purge (such as nitrogen) to reduce oxidation of the internal surface of the coil. 12 All field piping must be self-supporting. System piping should be flexible enough to allow for thermal expansion and contraction of the coil. The use of flexible connections and/or swing joints is recommended. 13 The coil along with the control valve and trap should be isolated by manual valves to allow for servicing. Daikin IM 901 7

Operation and Maintenance and Maintenance Operation General 1 Proper air distribution is vital to coil performance. Airflow anywhere on the coil face should not vary by more than 20%. 2 Air velocities should be maintained within Daikin's recommended values of between 200 and 1500 fpm. 3 Operating pressures must be at or below the maximum operating pressure for that coil at the steam temperature. Operating pressure maximum is 150 psig @ 300 F for low pressure steam coils and 350 psig @ 450 F for high pressure steam coils. Maintenance General DANGER Follow the manufacturer s guidelines for lockout/tagout and disconnect all power to the unit before performing maintenance. Contact with high voltage power will cause electrical shock, resulting in severe personal injury or death. WARNING Moving parts, high pressure, and/or high temperature fluids can cause serious personal injury. 1 Filters should be inspected on a regular basis and changed as needed. Clean filters help maintain maximum coil performance and service life. 2 Periodic inspection of the coil for signs of corrosion and/or leaks is recommended. Repair and replacement of the coil and the connecting piping, valves, etc., should be performed as needed by a qualified individual. 3 Should the coil surface need cleaning, caution should be exercised in selecting the cleaning solution as well as the cleaning equipment. Improper selection can result in damage to the coil and/or health hazards. 4 Suggested cleaning instructions: a When handling strong chemicals, be sure to wear chemical impervious gloves, apron and splash goggles. b Acti-Brite (AB-1) is the recommended cleaning solution. Contact your local Daikin Parts Distributor. CAUTION Carefully read and follow the manufacturer's recommendations before using any cleaning fluid. c Determine required dilution for the specific application. It is recommended to start with a dilution ratio of 10:1 and increase concentration until the desired results are achieved. d As with mixing all acids, place the desired amount of water into the tank and then add the chemicals. e Turn off fans and allow hot coils to cool before applying. f Using plain water, wet both the coil as well as the area surrounding the equipment. Wetting the coil with water aids in product penetration and performance. g Apply properly diluted product to coil surface. whenever possible, apply solution from the outlet side of the coil. Allow solution to remain on surface, normally 5-10 minutes. Do not allow solution to dry on the coil. Note: Note; In extreme cases, application may have to be repeated to achieve desired results. h If foaming does not occur, check for extreme grease buildup which will slow cleaning process. Foaming may not occur if coil is coated or painted. i Rinse coils, tools and surrounding area thoroughly after the coil cleaning. j Clean the coil from the leaving airside so that foreign material will be washed out of the coil rather than pushed further in. 5 Internal coil maintenance consists of preventing scale and corrosion. This is accomplished through aggressive boiler water treatment, removal of dissolved oxygen and the removal of non-condensable gasses such as carbon dioxide. Note: Boiler water treatment is beyond the scope of this manual. Contact your local water treatment specialist for assistance in establishing a proper boiler-water treatment program. 8 Daikin IM 901

Daikin Training and Development Now that you have made an investment in modern, efficient Daikin equipment, its care should be a high priority. For training information on all Daikin HVAC products, please visit us at www.daikinapplied.com and click on training, or call 540-248-9646 and ask for the Training Department. Warranty All Daikin equipment is sold pursuant to its standard terms and conditions of sale, including Limited Product Warranty. Consult your local Daikin Representative for warranty details. Refer to Form 933-43285Y. To find your local Daikin Representative, go to www.daikinapplied.com. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.daikinapplied.com. 2008 Daikin Applied www.daikinapplied.com 800-432-1342