Fiber Optic Splice Module

Similar documents
Opticom Rack Mount Fiber Enclosures

PanView iq (PViQ) Fiber Tray

8400 Series Fiber Distribution System

Fiber Connector Shelf (CCS)

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

Environmental Distribution Center (EDC-06P-NH)

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

FIBER CONNECTOR SAFETY WARNINGS

Fiber optic splice closure

Instructions for Use - Opt-X 1000i Enclosure

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

Fiber Splice Panel Rack Mount User Manual

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

Universal Splice Tray Installation Instructions

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

COYOTE STP (Service Termination Point)

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

Patching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable

COYOTE STP (Service Termination Point)

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

FL2000 Termination/Splice Panels User Manual

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

CORNING. CamSplice User Guide 2. TOOLS AN MATERIALS 1. GENERAL 3. LOADING CAMSPUCE INTO TOOL

INSTALLATION INSTRUCTIONS

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction

OFS Fitel LST1U-072/7 and LSTLW Instruction Sheet (LaserWave) Fiber Optic Comcode: Termination Shelf Installation

Z22C-** Preconfigured Network Zone System

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

NEMA-Rated Fiber Optic Wallmount Enclosure. Protects your fiber cabling in a damp environment.

LightLink Fiber Optic Splice Trays

Splice Only Sub Assembly. Follow all local safety regulations related to optical fibre plant elements

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

Multilink s Family of Wall Mount Enclosures

12-Inch Hybrid Fiber Access Terminal Installation Instructions

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

PLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

INSTALLATION INSTRUCTIONS

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

19 1HU Splicing and Front Patching Shelf

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

English. 1 of 5. Parts Supplied:

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

Part No. PAFULAxxx. Figure 2

WOC-364 Installation Instructions Ranger XP Heater System

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)

GENUINE PARTS INSTALLATION INSTRUCTIONS

3M Fiber Dome Closure FDC 10

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

Features: Use the selection chart below to choose the Splice Case and splice tray organizer which meet the requirements for your application.

Genesis 2 Measuring System

FOSC-400A4 INSTALLATION INSTRUCTION

2013 Road King CVO FLHRSE5 Detachable Fairing w/ Garmin Zumo 665 Installation Instructions

Replacing the T320 Cooling System Components. Replacing a T320 Fan Tray. Removing a T320 Front Fan Tray

Section 3 FIBERLIGN Closure Series

Network Zone System. Part Numbers: Z22N-****** Z22R-****

Universal Network Zone System Part Numbers: Z23U-****

INSTALLATION INSTRUCTIONS

BUDI-S-SP. Building distributor. Introduction. Seals. Kit content. Accessories. TC-957-IP Rev A, Feb Wrap around cable seals

Network Zone System Part Numbers: Z23N-***** Z23R-****

Vector Measuring System PARTS MANUAL

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

INSTALL INSTRUCTIONS DC C-EV. Installation Instructions: DC C-EV.

Installation instructions, accessories. Body kit

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

Fibre Optic. Page Fibre Optic Splice Trays 6-9 Fibre Optic Internal Wall Boxes 10 Fibre Optic Splice Closures Closure Accessories 21

No. Tool Vendor P/N. Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL.

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

COYOTE Terminal Dome Closure 6.5" x 22"

REVISION DESCRIPTION:

E90 AVIN Non-iDrive Head Unit Install with Logic 7 Integration

Three Function Remote Control System with Alarm (Model RCA-3)

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

PHASE 3 POWERSPORTS AUDIO KIT MAVERICK X3 CAN-AM. pg 3 Disassembly, Wire and Amplifier Plate Installation. pg 11 Dash Kit Installation

OPTICAL FIBER CLOSURE

FOSC-100 B/H FOSC-100 B2/H

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

DIN RAIL FIBER ENCLOSURE

TRUSCAN MEASURING SYSTEM

TESLA MODEL S REAR UNDER SPOILER & DIFFUSER SYSTEM

INSTALLATION INSTRUCTIONS

BEND LIMITING TUBING AND ACCESSORIES

GENUINE PARTS INSTALLATION INSTRUCTIONS

SWING DOOR SOFT ENCLOSURE (part# 16733)

Transcription:

.COM 2016 O 24 Fiber Optice Splice Module in open position INSTALLATION INSTRUCTIONS Fiber Optic Splice Module Part Numbers: FHD-FOSMF, FHD-FOSMM 12 Fiber Optice Splice Module in open position Contents: CAUTION: Fiber optic cable is sensitive to excessive pulling, bending and crushing forces. Consult the manufacturer s cable specification sheet for the specific cable in use. WARNING: UNMATED CONNECTORS MAY EMIT INVISIBLE LASER RADIATION. DO NOT LOOK DIRECTLY INTO THE END OF THE CONNECTOR. DO NOT INSPECT WITH MAGNIFYING DEVICES. MAINTAIN CAP ON UNMATED CONNECTORS. Care should be taken when opening and closing fully loaded drawer in order to protect fiber components. ASSEMBLY VIEW (24 Fiber Optice Splice Module Shown) Figure 1 Page 1 of 6

.COM 2016 INSTALLATION INSTRUCTIONS 12 Fiber Optice Splice Module Figure 2 Page 2 of 6

.COM 2016 INSTALLATION INSTRUCTIONS Typical cable routing for 12 Fiber Optice Splice Module or 24 Fiber Optice Splice Module Route sub-unit tube(s) through retention bridge as shown. Route 900µm buffered fiber from the trunk cable and splice to pigtail. Use enough cable length, approximately 1.2m (47") to ensure one complete loop of individual fibers around FHD-FOSM slack spools. Pigtails leading to FAPs should be a minimum of 1m (39.4"). Figure 3 Figure 4 Page 3 of 6

.COM 2016 INSTALLATION INSTRUCTIONS FHD-1UFCE and FHD-2UFCE Fiber Optic Splice Module Installation If 4 or 8 FHD-FOSMs are to be installed in the FHD-1UFCE or FHD-2UFCE, side latches on top module must be broken off to close the enclosure drawer. shown. Once mounted, fully seat fasteners to secure. Figure 5 Fully extend drawer to ensure proper amount of slack is used. Finish splicing in each FHD-FOSM before adding/stacking subsequent FHD-FOSMs. (cables omitted for clarity) Figure 5A Page 4 of 6

.COM 2016 INSTALLATION INSTRUCTIONS FHD-4UFCE Fiber Optic Splice Module Installation Place FHD-FOSM holder over M4 studs on sliding tray,secure with M4*8 hex nut. Remaining FHD-FOSMs are stacked on top of each other and snap in place after termination of lower tray. shown. Once mounted, fully seat to secure FAPs. Fully extend tray to ensure proper amount of slack is used. Finish splicing in each FHD-FOSM before adding/stacking subsequent FHD-FOSMs. (cables omitted for clarity). Figure 6 Page 5 of 6

.COM 2016 INSTALLATION INSTRUCTIONS FHD-2UFRME and FHD-4UFRME-N Fiber Optic Splice Module Installation Place first FHD-FOSM over M4 studs on sliding tray, and secure with M4*8 hex nut. Remaining FHD-FOSMs are stacked on top of each other and snap in place after termination of lower tray. shown. Once mounted, fully seat to secure FAPs. Figure 7 FHD-1UFMT-N and FHD-2UFMT Fiber Optic Splice Module Installation To remove top cover (not shown), remove screw at rear of enclosure, slide cover back and off. Utilizing double stick tape on underside, place first FHD-FOSM into tray. Remaining FOSMs are stacked on top of each other and snap in place after termination of lower tray. Figure 8 If 4 FHD-FOSMs are to be installed in the FHD-1UFMT-N, side latches on top module must be broken off to close enclosure drawer. shown. Once mounted, fully seat to secure FAPs. Page 6 of 6