Medium-Voltage Switchgear and Switches

Similar documents
CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

ga-gae630 2 ry Distribution Switchgear

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

ga / gae630 Reliable innovation. Personal solutions. Fully gas-insulated compact (RMU) and modular system

CPG.0 Single busbar gas-insulated cubicles

Metal Clad Switchgears

MESG 12 / 17.5 / 24 / 36 KV

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

ZX-Family Gas-insulated medium voltage switchgear

NXPLUS C Single busbar. Maintenance-free for lifetime

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Unitole UP kv Primary substations Motor control centres

Unitole UP kv Primary substations Motor control centres

CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

Power IT Air Insulated Cubicle Uniswitch

Extensible Unit - VCE2a

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

UniSec licensed by ABB, produced by Metix WHERE ENERGY LIVES COMPLETE SOLUTIONS

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Schedules 1 to 4, Lot B: Extension of the Lessos Substation

UniGear. Technical Guide

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

ZX-Family Gas-insulated medium voltage switchgear

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Gas Insulated Metal-clad Switchgear, HMGS!

MCset 4-24 kv Withdrawable SF6 circuit breaker

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

PIX-H Metal-clad switchgear up to 17.5kV

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

cpg.0 y cpg.1 Reliable innovation. Personal solutions. Families of single and double busbar GIS-type cubicles

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

36kV Gas Insulated Medium Voltage Switchgear

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

CBGS-0. Medium voltage distribution

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Air-insulated switchgear UniGear type ZS1

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

cpg.0 Reliable innovation. Personal solutions. Family of GIS metal-enclosed switchgear assemblies

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Metal Clad VCBs ~ Mk1

PT Guna Era Manufaktura. Catalogue GAE TPS \ Medium Voltage Switchgear 12kV - 24kV \ M GAE TPS. Medium Voltage Switchgear 12kV - 24kV

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

SF 6 -insulated, extensible circuit-breaker panel Type GAE630-1LSF(G)-/6/ for accessible switchgear rooms for rated voltages of up to 24 kv

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

I B D Q I B D Q O I B D Q O

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

Modular medium-voltage switchgear. NorMax

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

SPEN, Rasmus Larsson, High Voltage Breakers Innovative breaker solutions Substation design

with Vacuum Circuit Breaker HAF

ZX2.2 Gas-insulated medium voltage switchgear

Air-insulated medium-voltage secondary distribution switchgear

Key features. DESIGNS: - Conservator type - Hermetically sealed

8DJ. Maintenance-free for lifetime

ZX2 Gas-insulated medium voltage switchgear

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group May 15, 2013 Slide 1

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

SOUTH AFRICAN NATIONAL STANDARD

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

MCset 17.5 kv. Civil engineering guide April Medium Voltage Distribution

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

TECHNICAL SPECIFICATIONS OF PCC PANEL

Ed rev.0 CATALOGUE SWITCHGEAR 2015

Metal Clad Air Insulated Switchgear

the safe, reliable, and efficient choice for MV switchgear

Content. Uniswitch. 1. Design philosophy Applications Switchgear construction Cubicle types... 9

Switchgear Delta H2000 Medium voltage switchgear for primary distribution

W 12 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. DRIESCHER - Air-Insulated Medium-Voltage Switchgears

PIX High. Medium-voltage switchgear. Air-insulated switchgear kv ( 50 ka) Assembly - Operation - Maintenance Technical Manual

EMPAC Metal enclosed capacitor bank for wind applications

AIR INsULATeD switchgear >> PIX. up to 24 kv. Air-insulated switchgear with vacuum circuit-breaker. system configuration.

Cable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples.

BETA Low-Voltage Circuit Protection

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

Benefits, typical uses

Medium-Voltage Switchgear

COMPACT SUBSTATION GUIDE

with Vacuum Circuit Breaker HAF

132/11 kv, 25 MVA MOBILE SUBSTATION

cpg.0 & cpg.1 Reliable innovation. Personal solutions. Single and double busbar panel type GIS system

Transcription:

edium-voltage Switchgear and Switches G edium-voltage Switchgear up to 6 kv, 2.500A Product overview Switchgear for primary distribution level type CPG.0, CPG.1, AC Switchgear for secondary distribution level type GA, GAE, EA

Overview of switchgear Power generation level / High-voltage distribution network G Primary distribution level Secondary distribution level G 2

Types of switchgear: CPG.1 up to 6 kv; 1.5 ka; A see page 4 Types of switchgear: CPG.0 up to 6 kv; 25 ka; 1 A see page 4 AC up to 17.5 kv; 1.5 ka; A see page 6 Types of switchgear: GA up to 24 kv, 20(25) ka; 60 A see page 12 GAE up to 24 kv, 16/20 ka; 60/1250 A (can be freely combined) see page 8 EA up to 24 kv, 16/20 ka, 60 A see page 7

Switchgear for primary distribution level SF 6 -insulated, extensible panels with double busbar system Type: CPG.1* for rated voltages of up to 6 kv, 1.5 ka, busbar rated current up to A V2 Circuit-breaker cubicle F2 Fuse protection cubicle S2 Disconnector cubicle CL Busbar sectionaliser cubicle CT Busbar riser cubicle C2 Busbar coupling cubicle 1200 1200 * Please enquire about availability 4

Switchgear for primary distribution level Air-insulated, extensible panels Type: AC for rated voltages of up to 17.5 kv, 1.5 ka, busbar rated current up to A L Circuit-breaker panel LG Bus sectionaliser circuit-breaker panel 650 / 900 650 / 900 K Load-break switch panel 650 T Load-break switch panel with HRC fuse base 650 1 etering panel 1; sectionaliser 5 etering panel 5, with outgoing cables 650 / 900 650 / 900 6 etering panel 6 busbar voltage measurement 650 HG Bus sectionaliser riser panel H Bus riser panel with cable connection 650 / 900 650 / 900 E Busbar earthing panel S Contactor panel 650 650 * Height with discharge duct 2900 mm 5

Switchgear for primary distribution level SF 6 -insulated, extensible panels with single busbar system Type: CPG.1* for rated voltages of up to 6 kv, 1.5 ka, busbar rated current up to A V1 Circuit-breaker cubicle F1 Fuse protection cubicle S1 Disconnector cubicle C1 Busbar coupling cubicle 1200 *) Please enquire about availability SF 6 -insulated, extensible panels Type: CPG.0 for rated voltages of up to 6 kv, 25 ka, busbar rated current up to 1 A V Circuit-breaker cubicle F Fuse protection cubicle S Disconnector cubicle 2100 1) 2100 1) 2100 1) C Busbar coupling cubicle 1200 2100 1) 1) Height 2400 mm with high relay box 6

Switchgear for secondary distribution level SF 6 -insulated, extensible panels Type: GAE1250 for rated voltages of up to 24 kv, 16/20 ka, busbar rated current up to 1250 A -1LSV-/6/ Circuit-breaker outgoing panel -1LSVG-/6/ Bus sectionaliser circuit-breaker panel 825-1HT-/6 Busbar riser panel with disconnector -1AT-/6/ Cable riser panel with isolating switch 825 825 825-1LSF-/6/ Circuit-breaker outgoing panel -1K-/4/; -1K-/6/ Cable panel with load-break switch 400 / -1TS-/4/ Transformer outgoing panel with fused load-break switch -1E-/4/ Busbar earthing panel 400 400-11-/12.5/ etering panel 1250 795 7

Switchgear for secondary distribution level SF 6 -insulated, extensible panels Type: GAE60 for rated voltages of up to 24 kv, 16/20 ka, busbar rated current up to 60 A -1A1-// Cable connection panel -1K-//; -1K-/4/ Cable panel -1KG-// Bus sectionaliser load-break switch panel 50 20 / 400 640-1TS-/4/ Transformer outgoing panel -1LSF-/5/ ; -1LSF-/6/ Circuit-breaker panel -1LSFG-/5/; -1LSFG-/6/ Bus sectionaliser circuit-breaker panel 400 500 / 500 / * * * * 765 765-1LSV-/5/ Outgoing panel -1LSVG-/5/ Bus sectionaliser panel -1H1-// Bus riser panel in conjunction with -1KG- or -1LSFG- panel 500 500 50-1H2-/1/ Bus riser panel in conjunction with -1LSVG- panel 825 * Overall height depends on relay box 8

Switchgear for secondary distribution level SF 6 -insulated, extensible panels Type: GAE60 for rated voltages of up to 24 kv, 16/20 ka, busbar rated current up to 60 A -2K-/8/ Two cable panels -K-/10/ Three cable panels -2TS-/8/ Two transformer outgoing panels 800 980 800 2K 1TS-/10/Two cable panels, one transformer outgoing panel 980 9

Switchgear for secondary distribution level SF 6 -insulated metering panels Type: GAE60 for rated voltages of up to 24 kv, 16/20 ka, busbar rated current up to 60 A -11-/9/ etering panel for use behind a bus sectionaliser panel (1G or 1LSG) -12-/9/ etering panel for measuring with the busbar * * * * -1-/4/ etering panel for voltage measuring of busbar 400-14-/9/ etering panel with cable connection in incoming and outgoing * * * * -15-/9/ etering panel with cable connection in the incoming and busbar outgoing -16-/9/ etering panel for voltage measuring of busbar * * * * * Overall height depends on relay box 10

Switchgear for secondary distribution level SF 6 -insulated Ring ain Units Type: GA Standard (overall height = mm) for rated voltages of up to 24 kv, 20 (25) ka, busbar rated current up to 60 A 1TS 1A1 One transformer outgoing panel, one connection panel with 1 set of connection bushings 800 1TS 1A12 One transformer outgoing panel, one connection panel with 2 sets of connection bushings 80 2K 1TS Two cable panels, one transformer outgoing panel K Three cable panels 989 989 2K 1LSF Two cable panels, one outgoing panel with circuit-breaker K 1TS Three cable panels, one transformer outgoing panel 989 189 * * 765 2K 2TS Two cable panels, two transformer outgoing panels 4K Four cable panels 189 189 *Overall height depends on relay box 11

Switchgear for secondary distribution level SF 6 -insulated Ring ain Units Type: GA-C Standard (overall height = 1050 mm) for rated voltages of up to 24 kv, 20 ka, busbar rated current up to 60 A 1TS 1A1 One transformer outgoing panel, one connection panel with 1 set of connection bushings 800 1050 1TS 1A12 One transformer outgoing panel, one connection panel with 2 sets of connection bushings 80 1050 2K 1TS Two cable connection panels, one transformer panel K Three cable connection panels 989 1050 989 1050 2K 1LSF Two cable panels, one outgoing panel with circuit-breaker K 1TS Three cable panels, one transformer outgoing panel 989 189 1050* 150* 1650* 1050 765 2K 2TS Two cable panels, two transformer outgoing panels 4K Four cable panels 189 189 1050 1050 * Overall height depends on relay box 12

Switchgear for secondary distribution level Air insulated, extensible panels Type: EA for rated voltages of up to 24 kv, 16/20 ka, busbar rated current up to 60 A ZA Ring cable panel TA Transformer outgoing panel GA Bus sectionaliser load-break switch panel 550 / 750 550 / 750 550 / 750 * 75 * 75 * 75 LS Circuit-breaker outgoing panel LSG Bus sectionaliser circuit-breaker panel 750 / 900 750 / 900 1 etering panel within the bus sectionaliser * 975 / 1125 * 975 / 1125 * 75 2 etering panel within the busbar 4 etering panel with cable connections 5 etering panel with cable connection 1) * 75 * 75 * 75 5Ü etering panel within the bus sectionaliser 2) 6 etering panel for voltage measuring of the busbar * * 75 75 * with deflection shields 2100 mm / with arc fault absorbers 225mm 1) and busbar outgoing 2) with cable connection 1

Notes 14

Ormazabal Anlagentechnik GmbH Am Neuerhof 1 D-47804 Krefeld Tel.: +49 (0) 2151 7151 0 Fax: +49 (0) 2151 7151 8 oder 75 e-mail: anlagentechnik@ormazabal.de SF 6 -insulated switchgear Type GA Type GAE Type CPG.0 Type CPG.1 Air-insulated switchgear Type EA Type AC Air-insulated switches Type NVL Type KL(F), T, DES Subject to alteration CA 507 GB 0702