CPG.0 Single busbar gas-insulated cubicles

Similar documents
CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

cpg.0 y cpg.1 Reliable innovation. Personal solutions. Families of single and double busbar GIS-type cubicles

cpg.0 Reliable innovation. Personal solutions. Family of GIS metal-enclosed switchgear assemblies

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

CGM.3 Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv

cpg.0 & cpg.1 Reliable innovation. Personal solutions. Single and double busbar panel type GIS system

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

cpg.0 GIS-type medium-voltage switchgear with full insulation in SF 6 gas, up to 40.5 kv in accordance with IEC Standards

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Modular medium-voltage switchgear. NorMax

NXPLUS C Single busbar. Maintenance-free for lifetime

PIX-H Metal-clad switchgear up to 17.5kV

MESG 12 / 17.5 / 24 / 36 KV

Air-insulated switchgear UniGear type ZS1

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

CBGS-0. Medium voltage distribution

Unified requirements for systems with voltages above 1 kv up to 15 kv

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

ZX-Family Gas-insulated medium voltage switchgear

B kv Gas-insulated Substations

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Gas Insulated Metal-clad Switchgear, HMGS!

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Benefits, typical uses

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

B kv T&D GAS INSULATED SWITCHGEAR

ga / gae630 Reliable innovation. Personal solutions. Fully gas-insulated compact (RMU) and modular system

ZX2 Gas-insulated medium voltage switchgear

Metal Clad Switchgears

8DJ. Maintenance-free for lifetime

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

cgm.3 Reliable innovation. Personal solutions. Modular, compact system (RMU) with full gas insulation

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

cgm.3 system Fully SF6 gas insulated medium voltage switchgear up to 40.5 kv in accordance with IEC Standards

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

CGMCOSMOS-2LV. MEDIUM-VOLTAGE SF 6 GAS-INSULATED RING MAIN UNIT UP TO 12 kv LIB

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

Switchgear Type 8DJH 36 for Secondary

Product catalogue. ABB AS, Power Products Division SF 6. -insulated Ring Main Unit, SafeRing 36 and -insulated Compact Switchgear SafePlus 36

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

the safe, reliable, and efficient choice for MV switchgear

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

DPX moulded case circuit breakers

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

36kV Gas Insulated Medium Voltage Switchgear

with Vacuum Circuit Breaker HAF

EMPAC Metal enclosed capacitor bank for wind applications

Xiria the smart solution

SF 6. -insulated Ring Main Unit, SafeRing 36 and -insulated Compact Switchgear SafePlus kv ABB

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

cgm.3 2 ry Distribution Switchgear

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

GMA. Medium-voltage switchgear

Vacuum Circuit Breaker

PT Guna Era Manufaktura. Catalogue GAE TPS \ Medium Voltage Switchgear 12kV - 24kV \ M GAE TPS. Medium Voltage Switchgear 12kV - 24kV

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB

Content. Uniswitch. 1. Design philosophy Applications Switchgear construction Cubicle types... 9

CP Automatic capacitor bank

TGI Vacuum Circuit-Breaker Air isolator Earthing switch

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

CM5-03. Medium voltage air insulated arc proof metal clad Switchgears MINIVER/C

ZX2.2 Gas-insulated medium voltage switchgear

Medium voltage vacuum circuit breaker. E-VAC series

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS up to 40.5 kv, Gas-Insulated

3TM Vacuum Contactors

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Xiria the smart solution

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker

voltage switchgear ZX ABB ZX Family 1

Transcription:

MV Switchgear Primary Distribution CPG.0 Single busbar gas-insulated cubicles Up to 36 kv CPG System

The quality of products designed, manufactured and installed by Ormazabal is underpinned by the implementation and certification of a quality management system, based on the international standard ISO 9001:2000. Our commitment to the environment is reaffirmed with the implementation and certification of an environmental management system as laid down in international standard ISO 14001. In view of the constant evolution in standards and design, the characteristics of the elements contained in this catalogue are subject to change without prior notification. These characteristics, as well as the availability of components, are subject to confirmation by Ormazabal s Technical - Commercial Department.

Contents Primary Distribution MV Switchgear Introduction 2 Applications 2 Standards 2 Main Characteristics 3 Internal arc 4 Safety 5 Reliability 5 Types of Cubicle 6 Switching and Breaking Components 11 Protection, Metering, Control and Indication: 13 ekorsys family Interlocks 15 Installation 16 4

Primary Distribution MV Switchgear Introduction The CPG.0 range in Ormazabal s CPG system consists of a set of SF6 gas-insulated (GIS type) modular cubicles for configuring different primary distribution electrical diagrams in Medium Voltage networks up to 36 kv. Types of functional unit: Circuit-breaker CPG.0-V Busbar coupling CPG.0-C Disconnector CPG.0-S Fuse protection CPG.0-F The installation of components which enable it to withstand internal arcs in all its Medium Voltage compartments, combined with its advanced design which provides total protection against external environmental substances, make CPG.0 cubicles the ideal solution for use in substations whether for utility companies or private companies, providing safe, reliable distribution. The final quality of the supplied product is guaranteed by use of an automated manufacturing process, in which routine tests are performed across the various phases of the assembly procedure. Applications Designed for use in a wide range of installations, both public and private, its main applications include the following: Utilities Primary distribution substations Switching substations Mobile substations Industrial sector Cement industry Chemical and petrochemical industry Mining industry Iron and steel industry Automobile industry Textile industry Food industry Large infrastructures Wind farms Airports Railways Standards IEC 62271-001 Common specifications for high-voltage switchgear and controlgear standards. IEC 62271-200 Alternating current metal-enclosed switchgear and controlgear for rated voltages above 1 kv and up to and including 52 kv. IEC 62271-100 High voltage alternating current circuit-breakers. IEC 62271-102 Alternating current disconnectors and earthing switches. IEC 62271-105 High voltage alternating current switch-fuse combinations. Power stations Substation. 2 2

Main Characteristics CPG.0 cubicles are divided into separate compartments: A B Switch compartment. Busbar compartment. B D C Cable compartment. D Control compartment. A E E Operator interface. Their structure consists of a metal frame, whose mechanical rigidity ensures the non-deformity of the assembly in the expected service conditions. The frame, together with the rest of the cubicle s non-live metal parts, is connected to the general earthing busbar and thus contributes to the safety of the installation. The cubicles are interconnected by means of a busbar, installed in the upper part of the cubicles, in a compartment outside the switch compartment. C The switch compartment, which is sealed for life, houses the switching and breaking switchgear, with SF 6 gas as the insulating medium. Built of stainless steel, it has been designed and tested to withstand an internal arc up to 25 ka/1 s. The gases generated as a consequence of an internal arc are cooled and can be channelled through a relief duct located at the back. Depending on its functionality, it may contain the following components: Disconnector and earthing switch. Vacuum circuit-breaker. Fuse holders (CPG.0-F model). It can be connected to the busbar and the medium voltage cables respectively by means of bushings at the top and bottom. The gas pressure is tested by means of a temperaturecompensated pressure gauge, with a potential-free contact, allowing it to be used as a remote alarm or blocking/trip for the cubicle. The function of the busbar compartment, located in the upper part of the cubicle, is to house the busbar (electrical connection between the MV cubicles). Each of the phases which make up the busbar incorporates solid and shielded insulation, earthed by means of the compartment s specific earthing bar. Due to this singlephase layout, the cubicle is extremely reliable in terms of continuity of service. Thanks to the implementation of phase segregation by means of earthed metal plates, it can withstand an internal arc of 25 ka/1s. As an option, toroidal current transformers and/or plug-in voltage transformers can be installed in this compartment, without needing metering cubicles. 3 3

Primary Distribution MV Switchgear The cable compartment, which provides front access for the medium voltage cables, is located at the bottom of the cubicle, and has a cover which is interlocked with the earthing system. External cone bushings are used to install the toroidal current transformers. This compartment can be supplied ready to withstand an internal arc on the terminals of 25 ka/1 s, in line with the criteria of standard IEC 62271-200. As an option, the base can house the following components: Up to 4 reinforced shielded connection terminals (screw-in) per phase. Cable ties for the medium voltage cables. Earthing bars. Toroidal current transformers. Plug-in voltage transformers. Surge arresters. All the elements making up the enclosure are earthed by means of a conductor consisting of a copper strip designed to withstand the rated short-time current, allowing the MV cables and their corresponding terminals to be inserted or removed without the need to dismantle it. The control compartment, placed at the top of the cubicle and separate from the medium voltage area, is ready for installation of the metering equipment and protection relays, and contains the terminal block with the control signals already identified. Connections with the operator interface are via connectors, which makes the assembly more flexible, allowing the control compartment to be assembled and connected on site in a simple direct way. Cable compartment The operator interface, located in the middle, also includes the mimic diagram customised for each type of cubicle, and access for manual operation of: the disconnector driving mechanism, circuit-breaker, spring loading, etc. and the indicators. Operator interface Control compartment Internal arc Both as a whole and for its various compartments, the installation of different components allows the cubicle to withstand an internal arc of 25 ka/1 s, complying with the 5 criteria of Appendix A of standard IEC 62271 200 (class IAC-AFL). 4 4

Safety Protected against harsh environmental conditions (dust, pollution, humidity, salinity, etc.), protected against indirect contacts and long service life provided by its gas insulation, with the making and breaking components housed in separate stainless steel tanks, totally sealed for life. Internal arc withstand, accredited by means of tests conducted in accordance with the criteria of standard IEC 62271200 (IAC-AFL 25 ka 1 s). IP rating: IP65 for the tank, and IP3X for the cubicle assembly Temperature-compensated monitoring of the gas pressure inside the tank, including a potential-free contact. Presence/absence of voltage indicator, with permanent indication (multi-led) and optional contacts for remote display and/or creating electromagnetic interlocks. Power circuit fully insulated, including the cable terminals, all of which are screened, earthed and installed inside a metal enclosure. Ergonomic design, secure access to the control and signalling area, located outside the switch compartment. Safe, simple operation. Internal safety locks as standard, which prevent incorrect operations being performed. additional safety locks. Reliability Testing, including routine tests of all equipment in the factory. Sealed assembly: installation and assembly on site, without gas handling. Circuit-breaker with vacuum breaking technology, compact and with excellent reliability, certified in accordance with standard IEC 62271-100, including extended electrical endurance (class E2) with rapid reclosing cycle, and hence maintenance-free during its whole service life. Visual indication of the switchgear position in the mimic diagram. No maintenance on the live parts of the cubicles, increasing availability and continuity of service. Ease and reliability of connecting the control and signalling circuits via connectors. Loss of service continuity category: in accordance with IEC 62271-200: LSC2B. 5 5

Primary Distribution MV Switchgear Types of Cubicle CPG.0-V (Circuit-Breaker Cubicle) CPG.0-S (Disconnector Cubicle) CPG.0-F (Fused Protection Cubicle) CPG.0-C (Busbar Cubicle) TECHNICAL CHARACTERISTICS 24 kv 36 kv Rated current [A] General busbar Up to 1600 Up to 1600 Outgoing lines Up to 1600* Up to 1250* Lightning impulse [kv] Between phases and phase-to-earth 125 170 Isolating distance 145 195 Power frequency 1 min [kv] Between phases and phase-to-earth 50 70 Isolating distances 60 80 Rated short-circuit breaking current [ka] 25 25 Short-circuit making capacity (peak) [ka] 63 63 Rated short-time current [ka 1/3 s] 25 25 Internal arc withstand [ka 1 s] 25 25 Combined switch-fuse breaking capacity [ka] 25 25 Frequency [Hz] 50/60 50/60 IP rating IP3X IP3X (*) For fused protection cubicle = 200 A 6 6

CPG.0-V Circuit-breaker cubicle Includes a circuit-breaker with vacuum breaking technology and a three-position disconnector in series with it. Both components are located inside the three-position switch compartment. Applications: Main transformer protection. Feeder protection. Busbar coupling protection. Capacitor bank protection. Auxiliary service transformer protection. ELECTRICAL CHARACTERISTICS Rated voltage 24/36 kv Rated busbar current 1250/1600 A Rated outgoing line current 630/1250/1600* A Short-circuit current (1/3 s) 25 ka SF 6 control pressure gauge, with a potential-free contact Busbar Current transformers Voltage transformers Three-position disconnector Motor driving mechanism (disconnector) Interlocks** Vacuum circuit-breaker Motor driving mechanism Tripping coil 2nd tripping coil Closing coil Undervoltage coil Open/close push-button blocking Voltage presence detector Auxiliary contact Cable compartment Maximum no. of cables per phase 4 Toroidal current transformers Plug-in voltage transformers (*) Valid up to 24 kv. (**) See Interlocks section. PHYSICAL CHARACTERISTICS Height [mm] Width [mm] Depth [mm] Weight [kg] 2125/2425 # 600 1365 <750 ( # ) Depending on size of the control compartment. 7 7

Primary Distribution MV Switchgear CPG.0-S Disconnector cubicle Incorporates a three-position disconnector without load breaking capacity. Applications: Feeder/transformer disconnection. Busbar coupling riser. Busbar voltage metering. ELECTRICAL CHARACTERISTICS Rated voltage 24/36 kv Rated busbar current 1250/1600 A Rated outgoing line current 630/1250/1600* A Short-circuit current (1/3 s) 25 ka SF 6 control pressure gauge, with a potential-free contact Busbar Current transformers Voltage transformers Three-position disconnector Motor driving mechanism (disconnector) Interlocks** Voltage presence detector Auxiliary contact Cable compartment Maximum no. of cables per phase 4 Toroidal current transformers Plug-in voltage transformers (*) Valid up to 24 kv. (**) See Interlocks section. PHYSICAL CHARACTERISTICS Height [mm] Width [mm] Depth [mm] Weight [kg] 2125/2425 # 600 1365 <550 ( # ) Depending on size of the control compartment. 8 8

CPG.0-F Fused protection cubicle Equipped with a three-position switch-disconnector (closed/ open/earthing), also including fuse protection. The fuses are housed inside sealed fuse holders; these are housed inside the switch compartment, and enhance its insulation level. As an option, the three-pole opening switch via combined fuse blow action, can be motorised. Applications: Auxiliary service transformer protection. ELECTRICAL CHARACTERISTICS Rated voltage Rated busbar current Rated outgoing line current Short-circuit current (1/3 s) Switch-fuse combination breaking capacity. SF 6 control pressure gauge, with a potential-free contact Busbar Current transformers Voltage transformers Three-position disconnector Motor driving mechanism (disconnector) Interlocks* Fuses combined with the switch-disconnector Voltage presence detector Auxiliary contact 24/36 kv 1250/1600 A 200 A 25 ka 25 ka (*) See Interlocks section. PHYSICAL CHARACTERISTICS Height [mm] Width [mm] Depth [mm] Weight [kg] 2125/2425 # 600 1403 <550 ( # ) Depending on size of the control compartment. 9 9

Primary Distribution MV Switchgear CPG.0-C Busbar coupling cubicle Includes a vacuum circuit-breaker and two three-position disconnectors in series with it, one upstream and the other downstream of the circuit-breaker. These components are located inside the switch compartments. Applications: Busbar longitudinal coupling. ELECTRICAL CHARACTERISTICS Rated voltage Rated busbar current Rated outgoing line current Short-circuit current (1/3 s) SF 6 control pressure gauge, with a potential-free contact Busbar Current transformers Voltage transformers Three-position disconnector Motor driving mechanism (disconnector) Interlocks** Vacuum circuit-breaker Motor driving mechanism Tripping coil 2nd tripping coil Closing coil Undervoltage coil Open/close push-button blocking Cable compartment Lower busbar Toroidal current transformers 24/36 kv 1250/1600 A 1250/1600* A 25 ka (*) Valid up to 24 kv. (**) See Interlocks section.. PHYSICAL CHARACTERISTICS Height [mm] Width [mm] Depth [mm] Weight [kg] 2125/2425 # 1200 1365 <1300 ( # ) Depending on size of the control compartment. 10 10

Switching and Breaking Components DISCONNECTOR AND EARTHING SWITCH Disconnector Mechanical endurance Earthing switch Making capacity Electrical endurance Rated current Short-time current 24/36 kv M0 (1000 Operations) 63kA (50Hz) /65 ka (60Hz) E0* 630/1250/1600** A 25 ka - 1/3 s Features: 3 positions (closed - open - earthing). Actuation and independent levers for operations: Closed - open (Motor driving mechanism option). Open - earthing. (*) The earthing switch does not in itself have any making capacity, since this has been transferred to the circuit-breaker. The electrical endurance of the whole earthing circuit is E2 (5 short-circuit making operations) (**) Valid up to 24 kv. CIRCUIT-BREAKER 24 kv 36 kv Breaking capacity Short-circuit (asymmetry) 25 ka 25 ka DC 34% 38% No-load cable current 31,5 A 50 A Capacitor bank 400 A 400 A Electrical endurance E2 E2 Reclosing sequence O-0,3 -CO-15 -CO O-0,3 -CO-15 -CO Mechanical endurance Rated current M2 (10000 operations) 630/1250/1600 A M2 (10000 operations) 630/1250 A Short-time current 25 ka - 1/3 s 25 ka - 1/3 s Opening time <45 ms <45 ms Features: Vacuum circuit-breaker. Manual operation via push-button (padlockable). Motor driving mechanism 125 Vdc Spring loading time <15 seconds. Coils operative in the 125 Vdc range: 1 shunt trip opening coil. 2nd coil optional. 1 closing coil. 1 undervoltage coil (optional) Note: For other values, please consult Ormazabal s Technical - Commercial Department 11 11

Primary Distribution MV Switchgear SWITCH-DISCONNECTOR (Combined with fuses) 24 kv 36 kv Switch Rated current 200 A 200 A Main switch making capacity 63 ka 63 ka Switch category E3 E3 Electrical endurance 100 100 Electrical endurance (s-c making ops) 5 5 Electrical endurance (manual) M1 (1000) M1 (1000) Earthing switch Making capacity 7,5 ka 7,5 ka Disconnector category E2 E2 Electrical endurance (s-c making ops) 5 5 25 ka - 1/3s 25 ka - 1/3s Short-time current* 3 ka - 3s (earthing) 3 ka - 3s (earthing) Combined switch-fuse breaking capacity 25 ka 25 ka Transfer current >820 A >820 A (*) Fuse-limited. Features: 3 positions (closed - open - earthing). Actuation and independent levers for operations: Closed - open. Open - earthing. Switch driving mechanism: Latched manual (BR) with tripping coil at 125 Vdc. Option: Switch-disconnector motorisation at 125 Vdc. 12 12

Protection, Metering, Control and Indication: ekorsys family This family groups together a set of units which, when integrated in CPG.0 cubicles, provide protection, metering, control and indication functions in Medium Voltage electrical distribution networks: FEATURES OF THE ekorrps UNIT ekorrps Substation Protection Unit specially designed for vital applications in the field of Primary Distribution. Its incorporation in CPG.0 cubicles endows them with the necessary characteristics for inclusion in Integrated Control systems. Protection Control Event log Overcurrent 50/51-50 N/51 N Switch status and control Fault report Sensitive neutral 50 Ns/51 Ns Disconnector status and control Oscillograph Directional overcurrent 67/67 n Switch monitoring Chronology Overvoltage 59 Local panel Self-monitoring Undervoltage 27 Metering Cold load Frequency 81 From 30 electrical parameters Fault impedance/distance Unbalance 46-47 including voltage, current, Automation Reclosing 79 power and energy. Communications IEC 870-5-103 IEC 61650 ModBus RTU DNP3.0. PROCOME ekorrpg General Protection Unit designed to protect against overcurrent in electrical installations with Conventional Control. It is specially designed to protect a wide range of power ratings. FEATURES OF THE ekorrpg UNIT Protection Control Overcurrent 50/51-50 N/51 N Switch monitoring Sensitive neutral 50 Ns/51 Ns Fault report Reclosing 79 Self-monitoring Communications ModBus RTU PROCOME ekorivds Each cubicle has a voltage presence/absence detector with permanent light indication and, as an option, a free auxiliary contact for remote display of the corresponding indication. The indicator, with fixed installation, has been designed in accordance with standard IEC 61243-5 and VDE 0682 Part 415. 13 13

Primary Distribution MV Switchgear Current transformers Transformers developed by Ormazabal whose main characteristics are: Toroidal type. Encapsulated. Installed outside the switch compartment, upstream of the MV connectors. Capable of withstanding all environmental conditions. Ease of assembly and error-free during installation (earths). Installation: Busbar compartment. Cable compartment. ELECTRICAL CHARACTERISTICS Insulation level Rated withstand alternating voltage Rated frequency Continuous thermal current Insulation class 0,72 kv 3 kv / 1 min 50/60 Hz 1,2 Ir E RATIO Primary 150* A 600* A 200 A 800 A 250 A 1.000 A 300* A 1.200 A 400 A 500 A 1.600 A Secondary 1 A 5 A METERING PROTECTION CL 0,2 CL 0,5 5P10 5P20 (*) Main ratios. Note: Rated burden in accordance with current ratings. Voltage transformers Features: Plug-in type. Single-phase. Insulated. Shielded. Inductive operation. Installed outside the switch compartment. Capable of withstanding all environmental conditions. Anti-explosive. Installation: Busbar compartment. Cable compartment. ELECTRICAL CHARACTERISTICS Rated voltage 3,6 36 kv Continuous voltage factor. 1,2 Un Rated voltage factor Ur/8 hrs 1,9 Voltage in the secondary 100/ 3 V - 110/ 3 V - 100/3 V - 110/3 V Burden 25-50 VA Accuracy class 0,2-0,5-1 (metering) 3P - 6P (protection) Note: Characteristics can be configured according to the type of installation 14 14

Interlocks The disconnector, circuit-breaker and earthing switch are interlocked in accordance with section 5.11 of standard IEC 62271-200. The disconnector lever can only be inserted if the circuit-breaker is open. The circuit-breaker can only be operated if the disconnector/earthing switch actuating lever has been removed. Also, all electrical operations are overridden if the disconnector lever is located in the actuator shaft. The circuit-breaker can only be connected in the end positions of the disconnector/earthing switch. In the earthing position, electrical commands to open the circuit-breaker are overridden. Access to the fuse compartment is locked by the earthing switch. The cable compartment is only accessible with the earthing switch closed. As an option: Earthing switch electromagnetic interlock. Lockable interlocks: -- Earthing switch closed. -- Earthing switch open. -- Disconnector open 15 15

Primary Distribution MV Switchgear Installation Characteristics Reduced size, therefore taking up less space, due to its careful design and the use of SF 6 gas as insulating medium. Modularity and extensibility on both sides, ensuring an installation process which is quick and economical, in a smaller space, without gas handling on site, since it is not necessary to move adjacent cubicles in order to remove a cubicle in the middle. Reduced dimensions of the cubicle room, due to its front access and its design without withdrawable switchgear, and not requiring operational clearance at the back. Optimisation of installation costs and civil engineering works due to the smaller dimensions and limited need for operating space. Easy housing of voltage transformers and toroidal current transformers. Civil Engineering works The minimum recommended distances [mm] for correct installation, once installed in its final position, are: >600*** >100* Connection between Cubicles The connection between cubicles is external to the switch compartment and is via busbars with solid and shielded insulation, designed to allow a functional unit to be uninstalled without needing to move adjacent units and without gas handling. The copper busbars are designed to withstand a continuous rated current of 1250/1600 A, and also the thermal and dynamic forces of the rated short-time current (25 ka/1/3 s). >100*** >500 ** 750 (*) Not needed with pressure relief duct. (**) Operation: >1000 // Removal: >1500 (***) In accordance with Appendix A of standard IEC 62271-220 For other dimensions, please consult Ormazabal s Technical - Commercial Department 16 16

TECHNICAL - COMMERCIAL DEPARTMENT Tel.: +34 94 431 87 31 Fax: +34 94 431 87 32 www.ormazabal.com Transformer Substations x Prefabricated Transformer Substations up to 36 kv x MV Applications for Renewable Energies up to 36 kv Medium Voltage Secondary Distribution Switchgear x CGM.3 System x CGMCOSMOS System x Medium Voltage Primary Distribution Switchgear x CPG System x CPA-AMC System Protection, Control, Automation and Remote Control Distribution Transformers Low Voltage Switchgear CA 110 GB 0905