Drop Feeder Control. Part Number Introduction. Setting the Control. Time Clock operation. Manual Operation

Similar documents
Drop Feeder Control. Part Number Introduction. Setting the Control. Time Clock operation. Manual Operation

150 lb. Hopper Assembly

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

Feed Scale Installation & Operator s Instruction Manual

150 lb. Hopper Assembly

Model ATF End Control with Sensor Plus

Model 90 Twin Control Unit

Curtain Timer Control

Potentiometer Thrust Plate Kit (50421) Installation & Operator s Instruction Manual

ULTRAFLO Dead End Fill System. Installation Manual installation wiring diagrams parts list

Feeder Strap Winch. Part Number 54812

Extension Hopper Installation & Operator s Instruction Manual for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

48" and 52" Hyflo TM Un-Assembled Fans Assembly Manual

30Deg.Two Motor Tandem

Extension Boot System

Swivel Top Linear-Lift Installation & Operator s Instruction Manual

Two Motor Tandem. Installation Instructions. for Model 108 F LEX-AUGER Feed Delivery Systems

MODEL C2 Plus and MODEL G Plus Feeding System Operators Manual

36" Galvanized Direct Drive Hyflo Fan Installation and Operators Instruction Manual. Fan and Framing Dimensions

36" Hyflo Retrofit Kit Installation & Operator s Instruction Manual

Strap Winch Installation and Operators Instruction Manual

ANDCO Eagle Actuator Instruction Manual

Two Motor Tandem. Installation Instructions. for Model 108 F LEX-AUGER Feed Delivery Systems. Model 108 Two Motor Tandem Installation Instruction

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

P Original Series Cargo Van Lift Mounting Instructions Fullsize Ford Van present. Preparing the Gate

Volume III (December 1995 to January 2007)

PARTS LIST, COUNTER CONVECTION STEAMERS MODELS SN-3E, SN-4E, SN-5E PARTS LIST COUNTER CONVECTION STEAMERS BLODGETT MODELS: SN-3E SN-4E

48" and 52" Hyflo Fans Installation and Operators Instruction Manual

Strap Winch Installation and Operators Instruction Manual

Fuel supply system, servicing (vehicles with front wheel drive and 1.8 ltr. turbo or 2.8 ltr. engine)

48" Vanguard Slant Wall and Cone Belt Drive Fans Installation & Operator s Instruction Manual

Installation and Operation Manual

Optimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version

Installation Instructions Electric Heaters 5 20 kw

When done, these instructions and warranty information must be given to the consumer.

36" Hyflo Retrofit Kit Installation & Operator s Instruction Manual

3143 Production Drive Fairfeild, Ohio Model HA Installation and Service Manual

Lincolnweld AC-1000 POWER SOURCE

AQT-275 SERIES SERVICE MANUAL CONTROL VALVES

INSTALLATION MANUAL APPLICATION:

PRO REMOTE Series CAPACITANCE PROBE

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

MULTIFLO. Installation and Operators Manual

Water to Water Geothermal Heat Pump 3-Phase Models Both 208 & 480

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, Heavy Duty Safety Switches

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

CRD610 Automatic Fitting Inserter

Pressure Makeup Jockey Pump Controller

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET

Allura. Widespread Lavatory Faucet SLW-4712 Installation and Service Instructions. Quick Install Guide Allura Widespread Lavatory Faucet, SLW-4712

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, w Neutral, Visible-Blade, Heavy Duty Safety Switches

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

PART NO CP-DOOR FRONT PANEL WINDOW PART NO CP-DOOR FRONT PANEL SECOND WINDOW PART NO CP-DOOR LOCK PART NO. 5026

ASSEMBLY INSTRUCTION MANUAL

HS593 Feed Line Control Unit 230V Single Phase

AIR INTAKE EMERGENCY SHUT-OFF VALVE PH2 C50204 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS.

Installation Instructions Electric Heaters 5 20 kw

SUSSMAN 'ES, HU and MBA' SERIES PARTS LIST EFFECTIVE: 7/24/2017

Turbo-House Air Inlet Installation & Operator s Instruction Manual

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

CABINET REEL OPERATING INSTRUCTIONS

Grout Pump Automatic & Manual Troubleshooting Gas Wiring Diagram

Installation Instructions

MODEL ELC-12/40-CVM-D BATTERY CHARGER

MCO HALF SIZE MODELS (electric) MCO-E-5 FROM 2000 AND UP

Door Restrictor Assembly. Model R2

TC2000. This control box is typically located in the cab of the truck and the cable runs back to the auxiliary plug at the front of the trailer.

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

CRD600 Automatic Fitting Inserter

IN-VEHICLE REPAIR. Timing Drive Components. Removal. 3. Position the crankshaft keyway at the 12 o clock position.

INSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs.

INSTALLATION INSTRUCTIONS PERFORMANCE AT THE WHEELS KIT W125

MODEL 10LH SPECIFICATION

IMPORTANT INFORMATION

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

ASSEMBLY & OPERATION INSTRUCTION MANUAL

PCU-200 Laboratory Viscometer

5. Refer to GTR Workshop Manual, section: and disconnect battery ground cable.

Cleaning Flooded Gear

Operation Manual For KITZ B Series Pneumatic Valve Actuators

CATALOG OF REPLACEMENT PARTS

A Series 1-4 Pole Rotary Switches

R00DV. May 25, Dear Blue Bird Owner:


Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

IN-VEHICLE REPAIR. Timing Drive Components. Removal. 3. Position the crankshaft keyway at the 12 o clock position.

VANGUARD Series 36" Slant Wall and Cone Direct Drive Fans Installation & Operator s Instruction Manual

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Swivel Top Linear-Lift

AA4006 Speed Sensitive Trip Unit. User Manual

Remote Temperature Controller for Heated Mold Shoes, using a RTD/Digital Display, # C (version pre-2009).

Combine Cover Manual

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

Transcription:

Part Number 28999 Introduction The 28999 Drop Feeder Control is designed to be used with a Chore-Time Drop Feeding System and Chore- Time Flex-Auger System. The control will automatically open the Drop Feeders, close the Drop Feeders, and start the fill system. The system may also be operated manually. The components of the control are housed in a dust proof, water tight box. Liquid tight connectors must be used when wiring into the control. The cover must be latched in closed position unless switches or time clock is being adjusted. Wire the Drop Feeder Control, according to the appropriate wiring diagram. Setting the Control Unlatch and open front cover. MA922-7D Time Clock operation Set the desired feeding time(s) on clock by sliding out sufficient tabs to allow for auger run time. Slide out one additional tab for drop cycle (time required to open drops and close drops). Each tab represents 15 minutes. See Time Clock Features and Operation on page 5 for clock setting information. The lower toggle switch should be in the TIME CLOCK OPERATION position. The upper toggle switch should be in the OFF position. How it Operates When the switch on the time clock is activated by the tabs, all drops will open at the same time. The drops will automatically begin closing 15 seconds to 5 minutes after the clock is activated. This delay is adjustable inside the control panel. In multiple lift applications the #1 lift will completely close, then #2, etc. until all drops have closed. At that time the fill system contactor and AUGER ENABLED Pilot Light will become energized and the fill system auger(s) will refill the drop boxes. The switch in the Drop Feeder Control Unit will stop the fill system(s). The fill system contactor and AUGER ENABLED Pilot Light will remain energized until the tabs no longer activate the Time Clock Switch. CAUTION: Only use the number of time clock tabs needed to fill the system plus one extra tab. Manual Operation Set the lower toggle switch to the MANUAL OPERATION position. The Time Clock is now disabled and the drops may be opened or closed using the upper toggle switch. The upper toggle switch should be in the OFF position when not in use. June 2005 Chore-Time Equipment a Division of CTB Inc. P.O. Box 2000 Milford, Indiana 46542-2000 U.S.A. Phone (574) 658-4101 Fax (877) 730-8825 E-Mail: poultry@choretime.com Internet: http//www.choretime.com

2526-286 L1 L2 WH BLK ORG L1 L2 Drop Feeder Control How it Operates Set the upper toggle switch to the OPEN DROPS position and the drops will open. Set the upper toggle switch to the CLOSE DROPS AND FILL position, and the drops will close. When the balls are fully seated the fill system contactor and AUGER ENABLED Pilot Light will become energized. The switch in the Drop Feeder Control Unit will stop the fill system. Close the cover and secure latch to keep moisture and contamination from entering box and voiding warranty. Drop Feeder Control Internal Wiring Diagram (Feed-Fill) GREEN 230V 1PH SUPPLY TO 230V 1PH POWER PACK 230V 1PH TO FILL CONTACTOR GREEN MA922-3 10/95 2

Internal Wiring Changes for converting a standard 28999 Drop Feeder Control Panel to a Feed-Delay Fill style control In this mode of operation the drops will be full of feed at feeding. The refilling will be delayed to a preset time of choice. After the balls have been lifted to allow feeding, the ball will remain in the up position until time to refill the feed boxes. The control will need to be wired as shown to run as a delay fill system, See Figure 1. STEP 3 STEP 1 DISCONNECT WIRE HERE DISCONNECT WIRE HERE STEP 4 CONNECT WIRE HERE STEP 5 DISCONNECT WIRE AT BOTH ENDS AND DISCARD L1 L2 WH BLK ORG L1 L2 230V 1 PH SUPPLY TO 230 V 1 PH POWER PACK 230 V 1 PH TO FILL CONTACTOR STEP 2 CONNECT WIRE HERE MA922-6 10/95 Figure 1. Standard Control converted Instructions for setting the time clock, See Figure 2. Push in all the tabs between the selected feed time and fill time. With the time clock set this way it will delay filling of the boxes. 3

2526-286 L1 L2 WH BLK ORG L1 L2 Drop Feeder Control Drop Feeder Control Internal Wiring Diagram (Feed-Delay Fill) GREEN 230V 1PH SUPPLY TO 230V 1PH POWER PACK 230V 1PH TO FILL CONTACTOR GREEN MA922-8 10/95 4

Time Clock Features and Operation The outside edge of the clock face is a series of tabs. Use a finger nail of small screw driver to push tabs out. Each white tab on the time clock is equivalent to 15 minutes. Turn the white minute hand clockwise until the real time (actual time of day) is lined up with white arrow on inner clock face. Do not turn the hand counter-clockwise! This will strip out the nylon gears and void your warranty. Also, never adjust the time clock by turning the outer dial. Time of Day (AM & PM Format) Pull tabs as required for feeding cycle (1hr. shown) When adjusting, turn minute hand clockwise only. Figure 2. Setting Time Clock Drop Feeder Control (with Single Linear Actuator) Wiring Diagram 5

Drop Feeder Control (with Multiple Linear Actuators) Wiring Diagram 6

Drop Feeder Control (with One Linear-Lift ) Wiring Diagram 7

Drop Feeder Control (with Two Linear-Lifts ) Wiring Diagram 8

Drop Feeder Control (with One MULTI-LIFT and One Tower Switch) Wiring Diagram 9

Drop Feeder Control Two MULTI-LIFT /Two Tower Switches Wiring Diagram 10

Drop Feeder Control Parts Listing (Part No. 28999) Item Description Part No. 1 Pilot Light 7044 2 Control Box 28821 3 Push Nut Retainer 29879 4 10-32 Ground Screw 4968 5 #10 External Lock Washer 305 6 Corner Bracket 29013-1 7 Sheet Edge Insert 29878 8 Time Delay Relay (230 V) 29890 9 Fuse Block 7588 10 5 amp Normal Blow Fuse 7001 11 Mounting Plate 28689 12 Copper Lug 28822 13 Terminal Block 7270 14 ---- ---- 15 Strapping 29014-2 16 Mounting Adapter 25480 17 Time Clock 26795 18 Front Panel 28685 19 Toggle Switch 20135 20 Toggle Switch 29727 11

Made to work. SM Built to last. Contact your nearby Chore-Time distributor or representative for additional parts and information. CTB Inc. P.O. Box 2000 Milford, Indiana 46542-2000 U.S.A. Phone (574) 658-4101 Fax (877) 730-8825 E-mail: poultry@choretime.com Internet: http//www.choretime.com Printed in the U.S.A.