Via Michelangelo Buonarroti, 52/B Cologno M.se (Mi) USER S MANUAL

Similar documents
X-RAY FILM VIEWER FOR MAMMOGRAPHY HIGH LIGHT INTENSITY

LED Twister II. User manual UK Version 1.0

USER MANUAL LUX-LD30W LED MOVING HEAD

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

USER MANUAL PAR56 LED PAR CANS

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

ORIGINAL INSTRUCTIONS

Triple Output Power Supply

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Megohmmeter Test Probe

Model 1672, 1673 Triple Output Power Supply

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

6 x 10 Belt Disc Sander

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Non-Contact Phase Rotation Tester

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13

Fiber Optic Illuminator. Model 21AC Model 21DC

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

1 2 3a 3b THREADING CARD 9 10 ABC Office

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Mod: KLD6-12/35XLAS-N

PHASE ROTATION INDICATOR with OPEN PHASE CHECKER

EXCOUNT-I. User s manual

HLS Watt Halogen Illuminator Service Manual

Alternating Current Revolution per minute Protective Earth Ground. Protected from dripping water Fuse Attention, Consult Accompanying Document

28W WORK LAMP Model: CTL28 Part No:

Actuators for air dampers and control valves of oil burners

Switching DC Power Supply

INSTRUCTIONS FOR USE. Operation and Maintenance manual. Light Industrial Compressor. Hi-Tech Diagnostics Service

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

AMCON AUTOMATIC CHART PROJECTOR USER S MANUAL EQ-6002

Uninterruptible power supply Supply MEg101.4

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

BM kv Digital Insulation Tester USER MANUAL

Operatingmanual. Mehrsprachige Anleitung unter Multilingual manuals at. pro BENNING TRITEST BENNING BENNING BENNING.

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

Installation Instructions Central Battery Units

Operating Instruction for Downlights

DSP led gaming monitor USER MANUAL

SPECIFICATION FOR APPROVAL

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

OPERATING AND MAINTENANCE INSTRUCTIONS HYDRAULIC ELECTRICAL PUMPS HAM (Manual control) HAE (Electrical control)

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

MP V 8A Electronic Smart Charger. Instruction and Information Manual

OPERATING MANUAL CMP-200

PIL0478 ISSUE 01/ 07/16

Corded and Cordless LED Worklight

UView Mini Transilluminator

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

VOLT POT 1K R220. OPEN FOR 60 Hz STAB A.V.R. R220. Installation and maintenance

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

UNIVERSAL HEADLAMP BEAM SETTER

Magnetic Torpedo Laser Level with Base Model No Instruction Manual

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

Operating instructions SEARCHLIGHT SW300/ SW300A

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

Non-Contact Phase Rotation Tester

18V CORDLESS DRILL MODEL NO: CON18LiC

Triple Output High Resolution Power Supply. User Manual

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

2-Year Limited Warranty. See the Users Manual for the full warranty.

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

PET UNIT DOSE TABLE INSTALLATION MANUAL FN: Rev A 1/18

Mini Multimeter with Non-Contact Voltage Detector (NCV)

USE AND INSTALLATION HANDBOOK

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

Table of Contents. Classifications.. 5. Installation.,12. Focusing..14. Operating Instructions..15. Charts Description Maintenance...

Model 1693, 1694 Switching DC Power Supply

ECO Spot 2500 User Manual

Mini Hi-Fi System *MFL * SIMPLE MANUAL

ECO Spot 2500 User Manual

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

UV-cabinet DNA/RNA UVC/T-M-AR

3. Operating instructions: Minor 200

02OWNER S MANUAL 06 TROUBLESHOOTING 08LIMITED WARRANTY

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

3 PHASE TESTER & MOTOR ROTATION TESTER

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

SZ2-ILA INSTRUCTIONS TRANSMITTED ILLUMINATION ATTACHMENT SZ-ADD SZ-POL-2 SZH-CLJ. Optional Modules

CONTENTS 1. SIGN ANALYSIS 2. SECURITY EQUIPMENT SELECTION CRITERIA 3. PRODUCT INTRODUCTION 4. GENERAL RULES 5. CONNECTION OF SECURITY EQUIPMENT

Product Overview. Key Features. (ship.unit) PARATHOM MR ,5 W 2700 K 210 GU mm 50 mm 32 g

INFRESCO-S-4kW X20034 Issue: 7

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

UV Transilluminator Dual Wavelength (Large)

Autoranging Multimeter

DC POWER SUPPLY ALIMENTATION C.C.

System 3 ZB1PS Device Chassis. Operator s Manual

18V CORDLESS COMBI DRILL MODEL NO: CON18NI

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

Compact LED profile with zoom

FL B. Halogen light generator for Fibre optic lighting systems

Transcription:

Via Michelangelo Buonarroti, 52/B - 20093 Cologno M.se (Mi) USER S MANUAL LEDS FILM VIEWER FOR INDUSTRIAL RADIOLOGY CODE M-CB-20 DIM. CM 10 x 24 SUMMARY 1 Introduction...1 2 Symbols...2 3 Intended use...3 4 Precautions...3 5 Specifications...3 6 Nameplate and focus laser radiation...4 7 Safety test...4 8 Tool tips...5 9 Package contents...6 10 Specifications of use...6 11 Maintenance...6 13 Measures in case of failure...6 14 Accessories...6 15 Disposal...7 This manual is an integral part of the device, in case of transfer of the instrument must be attached to it.

1 Introduction Thank you for purchasing this product. The operating instructions are an integral part of this film viewer. Contain important safety information on the use and disposal. In the case of the sale of the device to third parties, together with all related documentation. Keep the purchase invoice for the product traceability and warranty period 2 Symbols Symbol Description WARNING: read this manual carefully LASER RADIATION DO NOT STARE INTO BEAM CLASS 2 LASER RADIATION Laser radiation, do not stand near of the beam. Device class 2. The device has a maximum luminance of 90,000 cd /sqm Do not open the cabinet. WARNING possibility of electrocution CAUTION: This device should only be used indoors Do not dispose into the environment. Managing the disposal under current legislation 0, I On switch: 0: off, I: on The sun with a few rays is low luminance. The one with many rays is high luminance. The arrow indicates the direction of rotation to increase the luminance.

3 Intended use The X-ray film viewer for industrial radiology code M-CB-20 Dim. cm 10 x 24 high luminance has been designed, manufactured and tested in compliance with applicable regulations. Is dedicated to the analysis of industrial radiography, high density (about 3.9 D) and should be used by individuals who are knowledgeable and trained. The X-ray film viewer is constituted by a casing of sheet metal coated with Platen opal material that has the function of spreading evenly the light coming from the plates illuminating diode LED. Is possible to adjust the luminance and control the switching by foot pedal placed on the floor or bench. The introduction of the LEDs in this category of viewers has allowed to reduce considerably the dispersion of energy in the form of heat and therefore increase the efficiency of 5 times, making negligible the temperature problems present in models with halogen lamps. The duration of the lighting elements is greater than 30,000 hours, virtually boundless. The quality of the light remains excellent for the entire duration of the LEDs. Maintenance costs are drastically reduced. 4 Precautions Note: The power connector is considered as the means of disconnection device: do not place the product in a way that is difficult to disconnect the power connector. The protection provided by the device may be compromised if used in a manner not specified by the manufacturer Before you install, connect, and use the film viewer, read the following carefully and follow these simple rules: Use the device only if you are entitled Keep the device completely away from water or other liquids Protect the power cord from sharp edges and hot surfaces Check before use that power cables, pedal and plug are intact Be sure to connect the negatoscope in earthed power efficient Do not use power supplies inadequate Do not look without eye protection, especially at close range, the luminance of this negatoscope (90,000 cd / sqm). This equipment is considered a Class 2 laser product Always keep the document table clean In case of scratches on the platen glass replaced in order to avoid errors of observation Do not defeat the dissipation of heat from the housing blocking the ventilation openings Use indoors only negatoscope If an inspection and / or replacement make sure that the film viewer is not too hot. Do not use the negatoscope in the presence of gas In case of scrapping To disperse the device or its parts Isolate the negatoscope before making any type of intervention, disconnect the device from the mains Use, in the event of replacement, fuses with the same characteristics 5 Specifications Technical characteristics of the industrial X-ray film viewer code M-CB-20 Dim. cm 10 x 24

Characteristics UM Securities Rated voltage V 230 Maximum power W 77 Frequency Hz 50 fuses I 5X20 T 400 ma L 250 Class of insulation I Laser product class 2 maximum luminance Cd/mq 90.000 Noise less than dba 85 Temperature range of use C 10 40 Relative humidity Max Rh 80% altitude M 2000 color Temperature K 6000 External Dimensions (H x W x D) cm 21 x 38 x 19,5 Size reading area cm 10 x 24 Cable length pedal cm 265 Length of supply cable cm 185 Weight kg 6.5 Degree of protection IP 20 Color Ral 5012 relative humidity RH 80 % Reference standard See Declaration of Conformity 6 Nameplate and focus laser radiation Cablas S.r.l. www.cablas.com Code M-CB-20 Dim. cm 10X24 Serial Number: 90.000 cd/sqm max 230V 50Hz 78 W F1, F2, 5x20 T 400 ma L 250 V LASER RADIATION DO NOT STARE INTO BEAM CLASS 2 LASER RADIATION 7 Safety test Each such product is made a proof of earth continuity between the ground terminal and accessible metal parts a dielectric strength test by applying AC voltage of 1390 V rms between power supply terminals (phase and neutral) and all accessible parts for at least 2 s.

8 Tool tips 2 Light box 5 Indicator light 8 Nameplate 9 Attention: laser radiation 3 Luminance aduste: increase in a clockwise direction 10 Reading mask 4 Switch 1 Pedal power light box 6 Fuse holder 7 Connector connection power cable Informations and note 1 can be used by hand or foot 2 observe floor covered with film to prevent damage to your eyes 3 always start with minimum luminance (potentiometer fully counter-clockwise) 4 Turn off the equipment after work 5 shows the lamp connection to network 6 in replacement use fuses with the same characteristics 7 Disconnect the power cord in case of maintenance 8 nameplate 9 attention to laser light 10 masks of reading to adapt the reading area of the film

9 Contents of the pack The product is packed in a cardboard box containing: Power cord User and maintenance 2 Spare fuses 5x20 T 400 ma L 250 V 2 Masks reading 10 Specification use Place the negatoscope so that it is convenient to use The negatoscope is designed to analyze radiographs industriai high optical density (about 3.9 D) and should be used: by staff trained and informed in place suitable internal. connected to the mains at 230 V ac with earth. placed on stable surface with appropriate height for operator sitting or standing. The foot switch can be used on the ground (with stand) or next to the film viewer. Warning! The maximum luminance of the device is very high (90,000 cd / sqm): do not look directly at the light table on: Class 2 laser product The platen should always be thoroughly cleaned (damp cloth) and free of scratches Insert the film to be analyzed to minimum luminance (regulator full scale anticlockwise) and increase it later, gradually until it reaches the value suitable for reading. 11 Maintenance Note: The power connector is considered as the means of disconnection device: do not place the product in a way that is difficult to disconnect the power connector. The protection provided by the device may be compromised if used in a manner not specified by the manufacturer Periodically check the condition of the table, the power cables, pedal and plug. Any replacement must be performed by qualified personnel. Any unauthorized intervention will void the warranty. For cleaning, use only a slightly damp cloth on the outside after being disconnected from the mains. NOTE: Periodically check the luminance reference tool 12 Product traceability On the nameplate of each negatoscope there is the serial number that uniquely identifies the object. This number should be quoted in any kind of request, together with the place and date of installation 13 Measures in case of failure Do not open the equipment absolutely For this device is intended by the operator only the intervention of replacing fuses. In case of failure, before calling for service, check the following: The wall outlet that is connected to the unit is powered The indicator light remains off even when the power is turned on, the pedal is pressed and the dimmer switch is rotated clockwise (maximum intensity). In this case, check, after disconnecting the unit from the mains, fuses and possibly replace them with fuses of the same characteristic. 14 Accessories Reading mask

15 Disposal Give the film viewer to licensed waste according to local regulations