Direct Contact Desuperheaters

Similar documents
Direct Contact Desuperheaters

VAD Variable Area Desuperheaters

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER

IBV Series C-LF2 Carbon Steel Inverted Bucket Vertical Steam Trap

FLOW TEK VALVES & CONTROL S INC

YARWAY NARVIK VEN-TEMP DESUPERHEATER MODEL 25

DESUPERHEATER (SERIES 800)

Yarway Narvik Ven-Temp Desuperheater Model 25

DP163, DP163G and DP163Y Pilot Operated Pressure Reducing Valves with Stainless Steel Bodies

SV80H Safety and Relief Valves

Fig B34 Carbon Steel 'T' Type or Basket Type Strainers

GVK Series (Steam-to-Steam) Clean Steam Generators

CE43 1" (DN25) to 4" (DN100) Carbon Steel Cage Design, Two Port Control Valves

SPIRA-TROL Two-port Control Valves ASME Standard KEA, KFA and KLA ½" to 8"

MFP14, MFP14S and MFP14SS Automatic Pumps

FT47 SG Iron Ball Float Steam Traps (DN15 to DN50)

Pilot Operated Pressure Reducing Valves with Stainless Steel Bodies

PV4 and PV6 Piston Valves

DP143, DP143G and DP143H. Pilot Operated Pressure Reducing Valves with Cast Steel Bodies

Pilot Operated Pressure Surplussing Valve with Cast Steel Body

SCA Series Steel Inverted Bucket Steam Traps

VELOCITY CONTROL TECHNOLOGY DESUPERHEATERS

Standard Duty A.T.S.A. - Temp Desuperheater Model 24 / 34

SDP143 Pilot Operated Pressure Surplussing Valve with Cast Steel Body

flow measurement solutions RIM10 series rotor insertion flowmeters

* Contact your sales representative for compliance to NACE MR or later requirements.

DP143, DP143G and DP143H. Pilot Operated Pressure Reducing Valves with Cast Steel Bodies

Fisher DFA Variable Geometry Desuperheater

LESLIE DESUPERHEATERS SIZES 1/2" 16" ANSI Class 150 to 2500

Standard Duty SLN - Temp Desuperheater Model: 50 / 60

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

M21Hi ISO Reduced Bore Ball Valve DN15 to DN150 Flanged PN40

YARWAY NARVIK MODEL 60/70 STANDARD DUTY SLN-TEMP DESUPERHEATER

Crosby Series 800 and 900 OMNI-TRIM Pressure Relief Valves. Flow Control

SAMSON 3281 & Steam Converting Valves SMART IN FLOW CONTROL

YARWAY NARVIK MODEL 33/43 STANDARD DUTY QUE-TEMP DESUPERHEATER

Yarway Narvik Desuperheater Model 18/54 and 28/64 Heavy Duty

M21Fi ISO Reduced Bore Firesafe API607 Ball Valve DN15 to DN150 Flanged PN40

PRESSURE REDUCING AND DESUPERHEATING STATIONS SERIES

10000 SERIES. Steam Desuperheater With Spray Nozzles

SEMPELL TURBINE BYPASS VALVE MODEL 115 CHP

YARWAY NARVIK STANDARD DUTY A.T.-TEMP DESUPERHEATER MODEL 38/48

Standard Duty Que - Temp Desuperheater Model: 33 / 43

m-csg Ultra-compact Clean Steam Generation System

* Contact your sales representative for compliance to NACE MR or later requirements.

DVG/AF Variable Geometry Desuperheater

M21Ti ISO Reduced Bore Ball Valve for the Tobacco Industry DN15 to DN150 Flanged PN40

394C. Series 6400/6600. Safety Valves for Power Boiler Service

DEP7 SG Iron Excess Pressure Valve

Heavy Duty Que - Temp Desuperheater Model: 13 / 23

SVL488 Stainless Steel Safety Valve for Clean Service Applications

Horizontal Pre-Piped Bladder Tanks with Proportioner

MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 APRIL 2004

DCV1, DCV2 and DCV3 Disc Check Valves Installation and Maintenance Instructions

Vertical Pre-Piped Bladder Tanks with Proportioner

The Pivotrol Pump Patented Selection and Sizing

MA-III & MA-IIIU MECHANICAL ATOMIZING DESUPERHEATER

M21Fi ISO Ball Valve DN15 to DN150

Yarway Que - Temp Desuperheater Standard-/heavy Duty Installation and maintenance Instructions

ABV21i and ABV40i Air Actuated Boiler Blowdown Valves

Datasheet MATRE Foam Inductors. Datasheet for MATRE Foam Inductors. 1 Contents

MSC-125 and MSC-160 Manifolds for Steam Distribution and Condensate Collection.

DP27, DP27E, DP27G, DP27R and DP27Y Pilot Operated Pressure Reducing Valves with SG Iron Bodies

Kunkle Bailey 756 safety relief valve

MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 SEPTEMBER 2001

Fisher DMA, DMA/AF, and DMA/AF HTC Mechanically Atomized Desuperheaters

S and SF Series Cast Iron Inverted Bucket Steam Traps

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

SERIES DESUPERHEATERS

MAHLE Automatic Filter Series R8-30W

SPIRA-TROL 1/2" to 4" ANSI Two-port KEA, KFA and KLA Control Valves

SERIES MULTIPLE NOZZLE DESUPERHEATERS

SV73 Cast Iron Safety Valve

Rosemount 1195 Integral Orifice Primary Element

MNSD-V & MNSD-U. Multiple Nozzle Spray Desuperheater

M10Si ISO Ball Valve DN¼" to DN2½"

BCV Blowdown Control Valves DN15 to DN50 (½" to 2")

ORIFICE PLATES, FLANGES FLOW NOZZLES, VENTURI TUBES AND ACCESSORIES

Hopkinsons CONTENTS SCHEDULE OF SHELL BOILER MOUNTINGS. Hopkinsons. Safety Valves 5. Boiler Stop Valves 17. Feed Check Valves 18. Blowdown Valves 20

Pamphlet M0000. Three-in-One Pressure Regulator, Separator, and Steam Trap COSPECTR PRESSURE REDUCING VALVES

Standard Duty A.T.-Temp Desuperheater for cryogenic processes

SPIRA-TROL 1/2" to 4" ANSI Two-port LEA, LFA and LLA Control Valves

APPLICATIONS IN PALM OIL MILL - CONTROL VALVE - DESUPERHEATER -PRDS -FLOWMETER -GAUGES

Model MTB-ASME Vertical Pre-Piped Bladder Tanks

Series 240 Type and Type Pneumatic Control Valves Type 3347 Hygienic Angle Valve

AEL6 Series Smart Electric Actuators for ½" to 4" Control Valves

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Spiratec ST14, ST16 and ST17 Sensor Chambers and Sensors

Series DK. Type DKV. Desuperheaters to control the Temperature of Superheated Steam (or Gas)

Model MTB-ASME Horizontal Pre-Piped Bladder Tanks

Yarway Narvik Model 37 and 47 Cryogenic injector

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Yarway Hy-Drop Throttling valve

SV418 Series Bronze Safety Valves ASME Section VIII - NB Certified for Air, Gas, Steam, and Liquid

DRV7 and DRV7G SG Iron Pressure Reducing Valves

YARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000

LCMass Series Mass Flow Sensor

PF6 Stainless Steel Piston Actuated On/ Off Valves

PF6 Stainless Steel Piston Actuated On/Off Valves

Best Under Pressure 3500 EBV. Safety Valve Oct 2008-CO

Transcription:

Control Description Spirax Sarco direct contact desuperheaters reduce the temperature of superheated steam to produce steam temperatures approaching saturation temperature to cool the superheated steam, water is entrained and flashed into vapor by absorbing heat from the steam. Typical applications: - To reduce the temperature of steam discharged from turbine by-pass systems on power plants for heat exchangers and dump stations. - To improve heat transfer of indirect contact heat exchangers - shell and tube, plate type, and reactor heating jackets. - To reduce the temperature of steam on direct contact applications - food cooking kettles, in-line steam heaters, tobacco drying plant and paper mills. Send us your requirements using our Desuperheater Enquiry Form available from our website. Features: - Low cost simple, robust design. - moving parts to wear. - Minimal steam pressure drop. - Flexible design options. Standards and approvals Spirax Sarco desuperheaters are available built to ASME B 31.3 design code. Also available are ASME III Division 1. This product fully complies with the requirements of the European Pressure Equipment Directive 97 / 23 / EC and carries the mark when so required. Welding is in accordance with ASME IX. Connections (EN 1092 or ASME B16.5) are sized to suit the process conditions. Standard ASTM materials of construction include: Carbon steel, Stainless steel, and Chrome molybdenum steel. Certification (included as standard): 1. Desuperheater general arrangement drawing. 2. Installation, operation and maintenance instructions. 3. Hydrostatic test certificate. 4. Letter of conformity. The following certificates / documents can be supplied at an additional cost. 5. Material certificates to EN 10204 3.1 with a corresponding material location diagram. 6. NDT reports. Pressure / temperature limits Spirax Sarco desuperheaters are custom products, individually designed to meet user defined process conditions. Mechanical design pressure and mechanical design temperature limitations are stated on the desuperheater data sheet available from our online sizing software. These limits are also stated on the product nameplate. Pressure / temperature ratings for these products will be in accordance with ASME B16.5-1996 or EN 1092-1:2007 as appropriate. 166 Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification.

Available types Control Spray type desuperheaters A simple type of in-line desuperheater with cooling water injected into the centre of the unit via an atomizing nozzle sprayed in the direction of the steam flow. Spirax Sarco spray type desuperheaters are available in two options:- 1. Spray nozzle desuperheater (SND) The assembly is designed for mounting on a suitable flanged branch on the steam pipework. A thermal sleeve installed downstream of the unit is recommended. Steam flow Applications: - Relatively constant load handling duties. - Retrofitting a desuperheater to an existing steam line. - Large steam lines where an STD could be cost prohibitive. Simple spray nozzle type desuperheater and flange rating <700 F (<374 C) 700-800 F (374-425 C) 795-1058 F (375-570 C) ASME 150, ASME 300, ASME 600, ASME 900, ASME 1500 + PN16, PN25, PN40, PN63 and PN100 Slip-on ASME 150, ASME 300, ASME 600, ASME 900, ASME 1500 + PN16, PN25, PN40, PN63 and PN100 Weld neck ASME 150, ASME 300, ASME 600, ASME 900, ASME 1500 Weld neck (Slip-on N/A) Materials Component up to and including 800 F (425 C) above 800 F (425 C) up to and including 1058 F (570 C) Pipe ASTM A106 Grade B ASTM A335 P11 Flanges ASTM A105N ASTM A182 F11 Spray nozzle ASTM A182 F316L ASTM A182 F11 zzle holder ASTM A350 LF2N ASTM A182 F11 Spirax Sarco, Inc., 1150 rthpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 167

Control 2. Spray type desuperheater (STD) A complete Desuperheater ready for installation, including spray nozzle, nozzle housing, thermal sleeve and flanged shell. Cooling water Spray nozzle assembly Thermal sleeve Superheated steam Desuperheated steam Applications: - Relatively constant load handling duties. - Dumping steam application. - Control of downstream temperature not critical. and flange rating <700 F (<374 C) ASME 150, ASME 300, ASME 600 + PN16, PN25, PN40 Slip-on (Weld neck optional) 700-977 F ASME 150, ASME 300, ASME 600 + PN16, PN25, PN40 Weld neck (Slip-on N/A) (374-525 C) 705-1058 F ASME 150, ASME 300, ASME 600, ASME 900, ASME 1500 Weld neck (Slip-on N/A) (375-570 C) Materials Component up to and including 800 F (425 C) above 800 F (425 C) up to and including 1058 F (570 C) Shell ASTM A106 Grade B ASTM A335 P11 Water branch ASTM A106 Grade B ASTM A335 P11 Flanges ASTM A105N ASTM A182 F11 Spray nozzle ASTM A182 F316L ASTM A182 F11 zzle holder ASTM A350 LF2N ASTM A182 F11 Thermal sleeve ASTM A312 TP316L ASTM A335 P11 Spirax Sarco, Inc., 1150 rthpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 168

Venturi type desuperheaters (VTD) The venturi principle is used to create regions of high velocity and turbulence which produces intimate contact between the steam and cooling water. Control Cooling water Internal diffuser Main diffuser Internal nozzle Steam flow Gaskets Application - Suitable for most general plant applications, except where high turndowns on cooling water are required. - Flow turndowns between 3:1 and 10:1 depending on conditions. and flange rating < 7 0 0 F (<374 C) 700-977 F (374-525 C) 705-1058 F (375-570 C) ASME 150, ASME 300, ASME 600 + PN16, PN25, PN40 Slip-on (Weld neck optional) ASME 150, ASME 300, ASME 600 + PN16, PN25, PN40 Weld neck (Slip-on N/A) ASME 300, ASME 600, ASME 900, ASME 1500 + PN10, PN16, PN25, PN40, PN63 and PN100 Weld neck (Slip-on N/A) Materials Component Shell Water branch Flanges up to and including 800 F (425 C) Sizes 1 to 2: ASTM A350 LF2N Size 3 and above: ASTM A106 Grade B Sizes 1 to 2: ASTM A350 LF2N Size 3 and above: ASTM A106 Grade B Sizes 1 to 2: ASTM A350 LF2N Size 3 and above: ASTM A105N above 800 F (425 C) up to and including 1058 F (570 C) Sizes 1 to 2: ASTM A182 F11 Size 3 and above: ASTM A335 P11 Sizes 1 to 2: ASTM A182 F11 Size 3 and above: ASTM A335 P11 ASTM A182 F11 zzle ASTM A182 F316L ASTM A182 F11 Internal diffuser Sizes 1 to 2: t applicable Sizes 1 to 2: t applicable Size 3 and above: ASTM A182 F316L Size 3 and above: ASTM A182 F11 Internal housing Sizes 1 to 2: t applicable Sizes 1 to 2: t applicable Size 3 and above: ASTM A350 LF2N Size 3 and above: ASTM A182 F11 Sizes 1 to 4: ASTM A350 LF2N Sizes 1 to 4: ASTM A182 F11 Main diffuser Sizes 6 and 8: ASTM A240 / ASTM A312 316L Sizes 6 and above: ASTM A387 Gr11 Size 10: BS EN 10130:2006 DC01 Size 12 and above: ASTM A516 Gr70 Internal seals Soft copper Soft copper Spirax Sarco, Inc., 1150 rthpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 169

Control Steam atomizing desuperheaters (SAD) A high pressure auxiliary steam supply is used to atomize the incoming water within the diffuser of the unit. The auxiliary steam pressure needs to be at least 1.5 times the desuperheater inlet pressure with a minimum pressure of 45 psig (3 bar g). Atomizing steam Internal nozzle Cooling water Internal diffuser Steam flow Steam flow Gaskets Application - High turndown applications where auxiliary steam is available, eg ;combined pressure reducing/desuperheating stations. and flange rating <700 F (<374 C) ASME 150, ASME 300, ASME 600 + PN16, PN25, PN40 Slip-on (Weld neck optional) 700-977 F ASME 150, ASME 300, ASME 600 + PN16, PN25, PN40 Weld neck (Slip-on N/A) (374-525 C) Materials Component up to and including 800 F (425 C) above 800 F (425 C) up to and including 1058 F (570 C) Shell ASTM A106 Grade B ASTM A335 P11 Atomising steam ASTM A106 Grade B ASTM A335 P11 branch Water branch ASTM A106 Grade B ASTM A335 P11 Flanges ASTM A105N ASTM A182 F11 zzle ASTM A182 F316L ASTM A182 F11 Diffuser ASTM A182 F316L ASTM A182 F11 Internal housing ASTM A350 LF2N ASTM A182 F11 Internal seals Soft copper Soft copper Spirax Sarco, Inc., 1150 rthpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 170

Sizing and selection There are a number of factors which must be considered in determining the best type of desuperheater for the job. Such factors are:- 1. Residual superheat. 2. Turndown. 3. Accuracy of final temperature. 4. Available pressure drop. 5. Cooling water pressure. 6. Auxiliary higher pressure steam available for atomizing. 7. Cost. With so many factors, it is not an easy task to develop a decision tree to aid selection, but the charts below have been developed to assist engineers in desuperheater selection. Please read this first chart in conjunction with the note at the bottom of the page. Control Desuperheater selection chart Turndown 1:1 2:1 3:1 4:1 5:1 7:1 10:1 20:1 50:1 (Steam Flow) Spray type desuperheater (STD) Spray nozzle type desuperheater (SND) Approach to saturation Tsat +9 F(+5 C) 'Cost effective option for turndown duties' Minimum water pressure: Steam 8 psi (+0.5 bar) Max. W.P: Steam +65 psi (+4.5 bar) Tsat +9 F(+5 C) Max. W.P: Steam +115 psi (+8 bar) Tsat +12 F (+7 C) Max. W.P: St +180 psi (+12.5 bar) Venturi type desuperheater (VTD) Tsat 'Our most popular desuperheater, ideal for most duties' +5 F (+3 C) Minimum water pressure: Steam +1.5 psi (+0.1 bar) Max. W.P: Steam +15 psi (+0.9 bar) Tsat +5 F (+3 C) Max. W.P: Steam +35 psi (+2.5 bar) Tsat +9 F(+5 C) Max. W.P: St +70 psi (+4.9 bar) Vertical installations only Tsat +12 F (+7 C) Max. W.P: St +145 psi (+10 bar) Steam atomizing type desuperheater (SAD) 'Special desuperheater for high turndown duties' Required water pressure: Same as steam pressure Atomizing steam required at 1.5 x Desuperheater inlet steam pressure or 45 psi (3 bar g) minimum SAD Tsat +5 F (+3 C) (with Tsat +5 F (+3 C) recycle) te: For VTD s, turndowns above 7:1 must not be offered until design checks have been made by Spirax Sarco. Spirax Sarco, Inc., 1150 rthpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 171

Control Which desuperheater is right for my application? This is a general guide and does not represent every option available. Please contact us if you have any queries regarding selection for your specific application. Start Are process parameters relatively fixed? Turndown < 2:1 SND or STD Is residual superheat? > 165 F (> 75 C) Is turndown? < 4:1 VTD or SAD without recycle Is turndown? < 5:1 Is application part of a pressure reducing station? Is turndown? < 50:1 Is it a vertical installation? Is application part of a pressure reducing station? Is auxillary steam available as an atomizing source? SAD without recycle Is auxillary steam available as an atomizing source? SAD with recycle Consider a number of appropriate units in parallel Sizing and selection software It is necessary to use our online sizing and selection software so that the desuperheater can be correctly specified and ordered. The software will generate a desuperheater data sheet and general assembly detail drawing of the resulting product. Please refer to TI-P475-06-US 'Desuperheater Online Programme Sizing Guidance' for further information. Spirax Sarco, Inc., 1150 rthpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 172

Safety information, installation and maintenance For full details see the Installation and Maintenance Instruction that are supplied with the product. Installation note may be installed either horizontally or vertically with the steam flowing upwards. Spirax Sarco strongly advizes against installations in which the steam flow is vertically downwards. In the case of a horizontal installation the cooling water connection (and the atomizing steam connection on a steam atomizing desuperheater) should ideally point downwards, as this gives the best orientation for drainage of fluids in a shutdown situation. Other orientations are acceptable for satisfactory operation, but drainage is not as effective. In a vertical installation we recommend that, the cooling water pipework (and atomizing steam pipework, if applicable) should be brought to the Desuperheater from below the corresponding connections on the desuperheater. This will provide the best layout for drainage of fluids on shutdown. Control Desuperheating and pressure reducing stations Spirax Sarco can provide complete desuperheating and pressure reducing stations including control valves, temperature sensors, pressure transmitters, instrumentation and pipework, all mounted on a support skid. Pressure regulating control valve Pressure controller Steam supply Desuperheater TS PT Temperature regulating control valve Cooling water Temperature controller Combined desuperheating and pressure reducing station for venturi and spray type desuperheaters Spirax Sarco, Inc., 1150 rthpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 173

Control Sizes Spirax Sarco desuperheaters are specified by their nominal inlet and outlet size in inches. For example a 3" (80 mm) connection is referred to as Size 3, a 10" (250 mm) would be Size 10. Dimensions and weights Please refer to the general assembly detail drawing generated by the sizing and selection software for details of specific desuperheaters. Selection guide Example Desuperheater type STD, SND, VTD and SAD VTD Steam inlet / outlet size, inches (mm) ¾" - 18" (20 mm - 450 mm) 3" (080) Shell / pipe material Steam end connections CS - Carbon steel A106 Grade B. For VTD sizes 1 to 2, CS = A350 LF2N material CM - Chrome molybdenum A182 F11 ASME 150, ASME 300, ASME 600, ASME 900, ASME 1500 PN16, PN25, PN40, PN63 and PN100 CS ASME 600 How to order 1 off Spirax Sarco Size 3 desuperheater model VTD080CS having ASME 600 RF slip-on flanged connections. (Attach the desuperheater Data Sheet with your order). Spare parts For units with fixed internals, spare parts are not available. Spare parts and internal diffuser removal tools are available for units fitted with removable internals. For guidance ; For VTD units 2" or smaller the internals are fixed For VTD units 12" or larger the internals are fixed For VTD units between 3" and 10" the internals are removable All STD units have fixed cooling water branch and nozzle Removable STD internals available as an 'optional extra' All SAD units have removable internals Please quote the equipment model number and serial number from the nameplate when requesting parts. Spirax Sarco, Inc., 1150 rthpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 174