w w w. i n d e l a c. c o m T O R Q U E S F R O M 100 L B - IN ( 1 1 N M ) T O 2 7, L B - IN ( N M )

Similar documents
Electric Actuators Maximum in-lbs

Electric Actuators Maximum in-lbs

E Series Electric Actuators

12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

A Compact and Reliable Quarter-Turn Electric Actuator

Series Village Lane Easley, SC Ph: (864) Fax: (864) Worm and Spur Gear Electric Actuators

TorqPlus TM Electric Valve Actuators and Controls

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

PNEUMATIC ACTUATORS. Linear acting

Electric Actuator Installation, Operation & Maintenance Manual

Linear Valve Electric Actuator

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

Actuated Valves. Product Information

LIMIT SWITCHES & POSITION INDICATION

EIM CONTROLS HQ-SERIES QUARTER TURN ELECTRIC ACTUATORS

TOP-QUALITY PNEUMATIC ACTUATOR

Electric Modulating Actuator Installation, Operation & Maintenance Manual

DMC mA Positioner

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

QUARTER-TURN ELECTRIC ACTUATORS

Electric Actuator Options & Accessories

Electric Actuator EQ Series

Actuated Valves PRICING

Z-Tech Severe Chemical Service Valves We Put Control Where You Need It.

Automation Selection Guide

POSITION TRANSMITTERS

Series 10 Actuator. Installation, Operation and Maintenance Manual

COMPLETE LISTING OF OPTIONS. Toggles, Lights

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

Q u a r t e r T u r n E l e c t r i c A c t u a t o r s

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

ivp PROGRAM FNW Ball Valves

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

Installation, Operation and Maintenance Manual

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

Position Transmitters. Instruction Manual. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

RCEL005 / RCEL

Quarter Master Chief Series 92 Actuator

MAQ Series Electric Actuator

Electric Actuator Accessories. Timer Board 115 VAC Input Suffix A (For EVR, EVS & EVT actuators)

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Morin series S actuator

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

Series Electric Actuators

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

SAFE & SECURE ACTUATOR PRODUCT MANUAL

Installation and Operating Manual

Quarter turn actuators Index

SERIES 1000 ELECTRIC ACTUATORS

LF Series Spring Return Direct Coupled Actuator

Models UP1/2/3/4/5/6/7 Universal pneumatic rotary actuators. Measurement made easy. High performance actuators for precision damper control

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

Pneumatic/Electric Actuators. Catalog 4123 August 2004

How to Select the RE Industrial Actuator Part Number

RCEL005 / RCEL

Eclipse Servo Motor Brake Flange Mounted, Spring Engaged, Air Released Split Hub, Clamp Collar Sizes 2, 3, 4, and 5 ECLIPSE PRODUCTS

3D TRASAR Automation - Boiler Blowdown Equipment

CONTROLS INC. Position Indicators. Valve Positioners

Valve Position Monitors

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

2000 Series Geared Rotary Limit Switches

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Pneumatic Actuators. 1. DIE CAST ALUMINUM END CAPS: standard polyester powder coated

SERIES 1000 ELECTRIC ACTUATORS

brands you trust. CRANE - Automation Actuators and Instrumentation

VALVES WITH SA ELECTRIC ACTUATOR

Integrated Control modules

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Customized ELECTRO-HYDRAULIC CONTROL SYSTEM

TOP-QUALITY PNEUMATIC ACTUATOR

Versatile and Powerful

Actuators & Positioners Models UP1/2/3/4/5/6/7. Universal Pneumatic Rotary Actuators

ECON ELECTRIC ACTUATOR Fig ELA60 Ex

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

SERIES 12 SUB-FHP RIGHT ANGLE DC GEARMOTORS

Quarter Master Series 94 Actuator

D-Series Rack & Pinion Pneumatic Actuators

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

AE Installation Operation & Maintenance Instructions

Automation Capabilities

Heavy-Duty Pneumatic Actuator. IS & IC Series

Installation, Operation & Maintenance Manual

Quantum Rotary Control Monitors Weatherproof IEC

Agent :

VALVES WITH NA ELECTRIC ACTUATOR

Biffi Morin S series actuators

Installation Instructions

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

HQ Series ¼ Turn Electric Actuator

Pneumatic Actuator Accessories. Discrete, NEMA 4, Four-Way Air/Air Suffix A2 (For PAD3 & PKD2 actuators)

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

VALVE ACCESSORIES & CONTROLS V200 POSITIONER A POSITIONER THAT OFFERS IT ALL IN ONE COMPACT, SIMPLE, HOUSING

Transcription:

T O R Q U E S F R O M 100 L B - IN ( 1 1 N M ) T O 2 7, 3 0 0 L B - IN ( 3 0 8 4 N M ) - Indelac Educational Content - PDF Product Catalog - PDF Wiring Diagrams w w w. i n d e l a c. c o m - Field Installation Instructional Videos - Coupons & Much Much More! QUICK AND EASY PAYMENTS USING VISA, MASTER AND AMERICAN EXPRESS CARDS NOW OFFERING NET 30 DAYS AND 1% LATE FEE ON INTERNATIONAL TRANSACTIONS

fter more then twenty five years of servicing the compact quarter turn valve & damper automation industry ICI is still family owned and American made. Here at Indelac, we proudly maintain the goals that inspired the companies beginnings. Mission Statement: ICI s mission is to manufacture a high quality electric actuator at a reasonable cost in a timely fashion. Quality Policy: Our quality policy is to manufacture electric actuators that our customers recognize to be of high quality at a price that is fair and reasonable. The companies management team is committed to conformance to corporate quality policy and to act as leaders in our efforts to meet our quality goals. Quality Objectives: Indelac is committed to continual quality improvement of all operating systems, products and services with our ultimate goal being zero defects and total customer satisfaction. These goals will be implemented through: - Total Quality Management (TQM) - Advanced Employee Training (AET) - Individual Responsibility (IR) - Advancements in Designs, Production Control and Manufacturing Technology (ADPCMT). These operational standards, specifications, rejection parameters, certifications, testing and inspection procedures will be our guidelines to manufacture our products. OFFICIAL WEBSITE EN ESPAÑOL: CHECK OUT OUR NEW VIDEO SERIES INSIDE AN ACTUATOR - PRODUCT TEST VIDEOS - FIELD INSTALLATION VIDEOS - 15 MIN. STEP BY STEP INSTALLS SIGN UP FOR INDELAC S E-NEWSLETTERS & STAY CURRENT - MONTHLY COUPON UPDATES - NEW PRODUCT RELEASES FIND HELPFUL PRODUCT INFORMATION - PDF PRODUCT CATALOG - PDF WIRING DIAGRAMS - PDF DRAWINGS - MOUNTING DIMENSIONS

2 Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90 115Vac & 230Vac 3.0 seconds/90 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard 115Vac & 230Vac 75% 12Vdc, 24Vdc & 24Vac Motor Permanent split capacitor 115Vac/1ph/50-6Hz standard With thermal over load protection L. R. Current 0.55 amps 115Vac, 0.38 amps 230Vac, 2.9 amps 12Vdc, 2.4 amps 24Vdc Enclosure NEMA 4 standard, CSA certified Coating Thermally bonded polyester powder Fasteners Captive, Output ISO 5211 F03, F04 or F03/04 Over Ride Brake Position Ind. Weight Lubrication Installation Temp. Range Switches 5.75.433 45 4.13 Manual, not declutching Not available on DC voltage Friction, standard Visual indicator Wired for light indication 6 Lbs. Permanent Universal -40 F. to 150 F. Heater & thermostat required 0 F. & below SPDT snap action 16amp ½ HP 125, 250Vac, 0.5amp 125Vdc 2.39 4,.207 DIA HOLES,.563 DP. 1/4-20 TAP,.44 DP. 2.121 B.C. 4,.149 DIA HOLES.563 DP. 10-24 TAP,.44 DP. 1.653 B.C. ALLOW 2-1/2" ((63.5) FOR COVER REMOVAL POSITION INDICATOR OPEN.25 (6.35) REMOVE DOME TO ACCESS MANUAL OVER RIDE R Series F04 Mounting Pad MANUAL OVER RIDE 4.72 (120) 1.31 (33.3) 4.13 (104.9).39 (9.9) 2.87 (73) 1.47 (37.3) 5.75 (146.1).35 (9) 45 1, 1/2-14 NPT CONDUIT ENTRY 2.39 (60.7) 4, 1/4-20 TAP,.44 (11.2) DP. 1.9685 (50) B.C. 4, 10-24 TAP,.44 (11.2) DP. 1.4173 (36) B.C. OPTIONAL CONDUIT ENTRY

3 Torque Cycle time Duty Cycle Motor 100 Lb-In (11.30 Nm) 2.5 seconds/90 115Vac 25% standard 115Vac Permanent split capacitor 115Vac/1ph/50-6Hz standard with thermal over load protection L. R. Current 0.55 amps 115Vac 0.38 amps 230Vac 2.9 amps 12Vdc 2.4 amps 24Vdc Enclosure Output Position Ind. Lubrication Weight Installation Temp. Range NEMA 7 not certified, Class I group C&D, Class II group E, F & G Div. 1&2 Specifications ISO 5211 F03 Visual indicator Wired for light indication Permanent 8 Lbs. Universal -40 F. to 140 F. Heater & thermostat required 0 F. & below.89 (22.6) ALLOW 2-1/2" (63.5) FOR COVER REMOVAL OPEN POSITION INDICATOR.25 (6.4) REMOVE DOME TO ACCESS MANUAL OVER RIDE MANUAL OVER RIDE OPTIONAL CONDUIT ENTRY 4.95 (125.7) 1.34 (34) 6.06 (153.9) 5.25 (133.4).433 (11) 1, 1/2-14 NPT CONDUIT ENTRY 45 4, 1/4-20 TAP,.44 (11.2) DP. 1.9685 (50)B.C. 2.88 (73.2) 4, 10-24 TAP,.44 DP. 1.4173 (36) B.C. 2.0 (50.8)

4 Torque 200 Lb-In (22.6 Nm) & 300 Lb-In (33.9 Nm) Cycle time 5 seconds/90 115Vac & 230Vac 10 seconds/90 with 75% duty cycle 9.0 seconds/90 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard 115Vac & 230Vac 75% optional 75% 12Vdc, 24V dc & 24Vac Motor Permanent split capacitor 115Vac/1ph/50-60Hz standard With thermal over load protection L. R. Current 200 Lb-In 0.75 (22.6 Nm) amps 115Vac 300 Lb-In 0.99 (33.9 Nm) amps 115Vac 0.38 amps 230Vac 4.2 amps 12Vdc 3.2 amps 24Vdc Enclosure NEMA 4 standard CSA certified (CSA file #LR79567) Coating Thermally bonded polyester powder Fasteners Captive, Output ISO 5211 F05 Mounting Pad ISO 5211 F03, F05 & F07 Over Ride Manual, not declutching Declutching manual over ride optional DC voltage & 75% Duty Cycle must be declutching Brake Friction, standard Position Ind. Visual indicator Wired for light indication Weight 10 Lbs. Lubrication Permanent Installation Universal Temp. Range -40 F. to 150 F. Heater & thermostat required 0 F. & below Switches SPDT snap action 16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc TO MANUALLY OVER RIDE REMOVE BEACON AND ROTATE SHAFT WITH 3/8'' (9.53) WRENCH POSITION INDICATOR ALLOW 3" (76.2) FOR COVER REMOVAL.91 (23.1) OPEN 5.39 (136.9).63 (16) 1.75 (45.45) 6.88 (174.8) 2.43 (61.8).55 (14) 1.0 (25.4) 45 OPTIONAL CONDUIT ENTRY 2.0 (50.8) 1/2 NPT CONDUIT ENTRY 4.25 (108) 2.88 (73.2) 4, 10-24 TAP,.44 (11.2) DP. 1.4173 (36) B.C. 4, 1/4-20 TAP, 0.44 (11.2) DP. 1.969 (50) BC DIMENSIONS (mm) 4, 5/16-18 TAP,.5 (12.7) DP. 2.756" (70) BC.

5 Torque Cycle time Duty Cycle Motor 200 Lb-In (22.6 Nm) & 300 Lb-In (33.9 Nm) 5 seconds/90 115Vac & 230Vac 10 seconds/90 with 75% duty cycle 9.0 seconds/90 12Vdc, 24Vdc & 24Vac 25% standard 115Vac & 230Vac 75% optional 75% 12Vdc, 24Vdc & 24Vac Permanent split capacitor 115Vac/1ph/50-60Hz standard With thermal over load protection L. R. Current 200 Lb-In 0.75 (22.6 Nm) amps 115Vac 300 Lb-In 0.99 (33.9 Nm) amps 115Vac 0.38 amps 230Vac 4.2 amps 12Vdc, 3.2 amps 24Vdc Enclosure Coating NEMA 4 standard Thermally bonded polyester powder Fasteners Output Mounting Pad Over Ride Brake Position Ind. Weight Lubrication Installation Temp. Range Switches Captive, ISO 5211 F05 ISO 5211 F03, F05 & F07 Optional Friction, standard Visual indicator optional Wired for light indication 14 Lbs. Permanent Universal -40 F. to 150 F. Heater & thermostat required 0 F. & below SPDT snap action 16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc NOTE: 24Vac motors are 24Vdc motors rectified for use with 24Vac voltage. ALLOW 3" (76.2) FOR COVER REMOVAL 6.88 (174.8) 3.1 (78.7) 2.11 (53.6).63 (16) 7.34 (186.4) 4.75 (120.7).55 (14) 45.0 4.75 (120.7) 1/2-14 NPT CONDUIT ENTRY 4, 5/16-18 TAP.5 (12.7) DP. ON 2.756 (70) BC 4, 10-24 TAP,.44 (11.2) DP. 1.4173 B.C. 4, 1/4-20 TAP.44 (11.2) DP ON 1.968 BC DIMENSIONS (mm)

6 Torque Cycle time Duty Cycle Motor 200 Lb-In (23Nm) & 300 Lb-In (34Nm) 5 seconds/90 115Vac & 230Vac 10 seconds/90 with 75% duty cycle 9.0 seconds/90 12Vdc, 24Vdc & 24Vac 25% standard 115Vac & 230Vac 75% optional, 75% 12Vdc, 24Vdc & 24Vac Permanent split capacitor 115Vac/1ph/50-60Hz standard with thermal over load protection L. R. Current 200 Lb-In (22.6 Nm) 0.75 amps 115Vac 300 Lb-In (33.9 Nm) 0.99 amps 115Vac 0.38 amps 230Vac, 4.2 amps 12Vdc, 3.2 amps 24Vdc Enclosure Coating Fasteners Output Mounting Pad Over Ride NEMA 7 standard, C, US certified by CSA Thermally bonded polyester powder ISO 5211 F05, ISO 5211 F03, F05 & F07 Available as an option only (not standard) Manual, not declutching Declutching manual over ride optional DC voltage must be declutching Brake Position Ind. Weight Lubrication Installation Temp. Range Switches Friction, standard Visual indicator, Wired for light indication 16 Lbs. Permanent Universal -40 F. to 150 F. Heater & thermostat required 0 F. & below SPDT snap action 16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc ALLOW 4" (101.6) FOR COVER REMOVAL DIMENSIONS (mm) 1/2 N.P.T. CONDUIT ENTRY 6.39 (162.3) 1.39 (35.3).63 (16) 2.31 (58.7) 8.53 (216.7) 9.41 (239).55 (14) STAR 8.66 (220) 3.13 (79.5) 3.2 (81.3) 7.78 (197.6) 4, 1/4-20 TAP.44 (11.2) DP. 1.969 (50) B.C. POSITION INDICATOR.38 (9.65) OPEN 1.28 (32.5) 1.28 (32.5) 2.48 (63).5 (12.7) OPTION #1 ROTATE THROUGH GEARS OPTION #3 DECLUTCHING WITH PUSH KNOB OPTION #2 DECLUTCHING WITH HAND WHEEL OPTIONAL MANUAL OVER RIDE AND POSITION INDICATOR.5 (12.7).5 (12.7)

7 Torque Cycle time Duty Cycle Motor 400 Lb-In (45.2 Nm) model MS 675 Lb-In (76.3 Nm) model MR 1000 Lb-In (113 Nm) model ML 1500 Lb-In (169 Nm) model MH MS 10 seconds/90 115, 230Vac & 12Vdc MS 20 seconds/90 75% duty, 24Vdc & 24Vac MR & ML 15 seconds/90 115, 230Vac & 12Vdc MR & ML 30 seconds/90 75% duty, 24Vdc & 24Vac MH 30 seconds/90 115, 230Vac & 12Vdc MH 70 seconds/90 75% duty, 24Vdc & 24Vac 25% standard 115Vac & 230Vac 75% optional 75% 12Vdc, 24Vdc & 24Vac Permanent split capacitor 115Vac/1ph/50-60Hz standard With thermal over load protection L. R. Current 115Vac MS & MR= 0.75 amps 115Vac ML & MH= 0.99 amps 230Vac MS, MR, ML & MH=0.38 amps 12Vdc 4.2 amps 24Vdc 3.2 amps Enclosure Coating Fasteners NEMA 4 standard, CSA and C, US certified Thermally bonded polyester powder Output Mounting Pad Over Ride Brake Position Ind. Weight Lubrication Installation Temp. Range Switches ISO 5211 F07 ISO 5211 F07 Manual, declutching Friction, standard Visual indicator Wired for light indication 18 Lbs. Permanent Universal -40 F. to 150 F. Heater & thermostat required 0 F. & below SPDT snap action 16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc ALLOW 4'' (101.6) FOR COVER REMOVAL MANUAL OVER RIDE PUSH AND ROTATE TO ENGAGE, PUSH A SECOND TIME TO DECLUTCH VISUAL POSITION INDICATOR OPEN 9.03 (229.4) 7.09 (180.1) 1.76 (44.7) B 2.81 (71.4) A.63 (16).67 (17) 1/2" NPT CONDUIT ENTRY C 4, 5/16-18 TAP.4 (10.2) DEEP 2.756 (70) B.C. A 4, 3/8-16 TAP.56 (14.2) DEEP 4.015 (102) B.C. MH ONLY Model A B C ML - MS 7.0 (177.8) 2.38 (60.5) 2.63 (66.8) MH 8.5 (215.9) 3.13 (79.5) 3.38 (85.9) DIMENSIONS IN INCHES DIMENSIONS (mm)

8 Torque Cycle time Duty Cycle Motor 400 Lb-In (45.2 Nm) model MS 675 Lb-In (76.3 Nm) model MR 1000 Lb-In (113 Nm) model ML 1500 Lb-In (169 Nm) model MH MS 10 seconds/90 115, 230Vac & 12Vdc MS 20 seconds/90 75% duty, 24Vdc & 24Vac MR & ML 15 seconds/90 115, 230Vac & 12Vdc MR & ML 30 seconds/90 75% duty, 24Vdc & 24Vac MH 30 seconds/90 115, 230Vac & 12Vdc MH 70 seconds/90 75% duty, 24Vdc & 24Vac 25% standard 115Vac & 230Vac 75% optional 75% 12Vdc, 24Vdc & 24Vac Permanent split capacitor 115Vac/1ph/50-60Hz standard With thermal over load protection L. R. Current 115Vac MS & MR= 0.75 amps 115Vac ML & MH= 0.99 amps 230Vac MS, MR, ML & MH=0.38 amps 12Vdc 4.2 amps 24Vdc 3.2 amps ALLOW 4'' (102) FOR COVER REMOVAL MANUAL OVER RIDE PUSH AND ROTATE TO ENGAGE, PUSH A SECOND TIME TO DECLUTCH R.25 (8) Enclosure Coating Fasteners Output Mounting Pad Over Ride Brake Position Ind. Weight Lubrication Installation Temp. Range Switches 2.2 (56) NEMA 7 standard, C, US certified by CSA Thermally bonded polyester powder ISO 5211 F07 ISO 5211 F07 Manual, declutching Friction, standard Visual indicator Wired for light indication 20 Lbs. Permanent Universal -40 F. to 150 F. Heater & thermostat required 0 F. & below SPDT snap action 16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc VISUAL POSITION INDICATOR OPEN 9.0 (229) 7.1 (180) 1.76 (44.7).63 (16).667 (17) 3.13 (80) 8.50 (216) 2.81 (71) 1/2" NPT CONDUIT ENTRY OPTIONAL ADDITIONAL 1/2" NPT CONDUIT ENTRY 3.38 (86) 8.5 (216) 4, 3/8-16 TAP.56 (14) DP. 4.015 (102) B.C. 4, 5/16-18 TAP.4 (10) DP. 2.756 (70) B.C. DIMENSIONS (mm)

9 Torque Cycle time Duty Cycle Motor LA 2000 Lb-In (226 Nm) LX 3840 Lb-In (434 Nm) LA 12 seconds/90 LX 14 seconds/90 Continuous Permanent split capacitor 115Vac/1ph/50-60Hz standard With thermal over load protection L. R. Current 115Vac LA= 1.50 amps (FL=0.98 amps) 115Vac LX= 2.90 amps 230Vac LA=.80 amps 230Vac LX=1.50 amp 12Vdc LA=4.93 amps 12Vdc LX=6.83 amps Enclosure NEMA 4 standard, C, US certified by CSA NEMA 7 optional, C, US certified by CSA Coating Fasteners Output Mounting Pad Over Ride Brake Position Ind. Weight Lubrication Installation Temp. Range Switches Thermally bonded polyester powder ISO 5211 F07 Male double D shaft with 4.242 BC Manual, declutching Power Off, optional Visual indicator Wired for light indication 40 Lbs. Permanent Universal -40 F. to 150 F. Heater & thermostat required 0 F. & below SPDT snap action 16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc ALLOW 6'' (152) TO REMOVE COVER MANUAL OVER RIDE HAND WHEEL POSITION INDICATOR OPEN 9.96 (253).31 (8) 2.5 (63.5) ACROSS FLATS.875 (22.23) 1.12 DIA. (28.5) 3.0 (76) 10 (254) 3.75 1.29 (95) (32.5) 1.19 (30) 3/4-14 NPT CONDUIT ENTRY 4, 5/16 DRILL 13/16 (21) DP. 3/8-16 TAP 5/8 (16) DP. 4.015 (102) B.C. 10 (254) 3.75 (95) 4, 5/16 DRILL 13/16 (21) DP. 5/16-18 TAP 5/8 (16) DP. 2.756 (70) B.C. 6.88 Ø 7 (178) (175) HAND WHEEL 45 45

10 Torque Cycle time Duty Cycle Motor Model 5K=5000 Lb-In (565 Nm) Model 7K=7020 Lb-In (793 Nm) Model 12K=11520 Lb-In (1302 Nm) Model 14K=14040 Lb-In (1586 Nm) Model 5K=38 seconds/90 Model 7K=38 seconds/90 Model 12K=43 seconds/90 Model 14K=68 seconds/90 30 Minutes Permanent split capacitor 115Vac/1ph/50-60Hz standard With thermal over load protection L. R. Current 115Vac 5K=2.9 amps, 7K=4.1 amps 12K & 14K=7.1 amps 230Vac 5K= 1.5 amps, 7K=2.3 am 12K & 14K=3.8 amps 12Vdc 5K=4.93 amps, 7K=6.83 amps 24Vdc 5K= amps, 7K= amps Enclosure Coating Mounting Pad Over Ride Brake Position Ind. Weight Lubrication Installation Temp. Range Switches NEMA 4 standard NEMA 7 optional Thermally bonded polyester powder Fasteners Male double D shaft 300 series stainless steel Manual, declutching Power Off, optional Visual indicator Wired for light indication 110 Lbs. Permanent Universal -40 F. to 150 F. Heater & thermostat required 0 F. & below SPDT snap action 16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc ALLOW 7" FOR COVER REMOVAL POSITION INDICATOR 3/4-14 NPT CONDUIT ENTRY DECLUTCHING MANUAL OVER RIDE OPEN 3.8 2.2 (96.5) (56) OPTIONAL CONDUIT ENTRY 13.5 (343) 16 (406) 4.63 (118) A 5.3 (135).13 (3.3) B C DIA. 13.5 (343) 4, 3/8-16 TAP,.63 (16) DP., 4.242 (107.7) B.C. 5.44 (138) 45 4, 5/8-11 TAP, 3/4 (19) DP., 5.5118 (140) B.C. 12.9(328) MODEL A B C 5K 1.19.875 1.13 (30) (22.2) (28) Ø 7.3 (185) 14.0 (356) 7K, 12K & 14K 1.60 1.42 2.38 (41.6) (36.1) (60.5) DEMINSIONS (mm)

11 Torque 27300 Lb-In (3084 Nm) Cycle time 136 seconds/90 Duty Cycle 30 minutes Motor Permanent split capacitor 115Vac/1ph/50-60Hz standard with thermal over load protection L. R. Current 115vAC = 7.1 amps 230vAC = 3.8 amps Enclosure NEMA 4 standard NEMA 7 optional Coating Fasteners Mounting Pad Over Ride Brake Position Ind. Weight Lubrication Installation Temp. Range MODEL 27K Switches Thermally bonded polyester powder coating 2.375 Bore Manual, declutching Power Off, optional Visual indicator Wired for light indication 170 Lbs. Permanent Universal -40 F. to 150 F. Heater & thermostat required 0 F & below SPDT snap action 16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc 3.75 (95.3) ALLOW 7" (177.8) FOR COVER REMOVAL 2.19 (55.6) 3/4-14 NPT CONDUIT ENTRY OPTIONAL CONDUIT ENTRY DECLUTCHING MANUAL OVER RIDE 13.52 (343.4) 16 (406.4) 4.62 (117.3) 1.457 (37.01) 2.375 +.005/-.000 (60.33) BORE 27.15 (689.6) Ø 7.50 (190.5) 8.0 (203.2) O P E N 22.5 45 CLOSE 5.31 (134.9) 5.15 (130.8).625 (15.9) KEYWAY BOTTOM VIEW MOUNTING DIMENSIONS 18.81 (477.8) 13.5 (342.9) 8, 5/8-11 TAPPED HOLES, 1 (25.4) DP. 8.06 (204.7) 6.06 (153.9) 12.88 (327.2)

12 Torque 200 Lb-In (22.6 Nm) Cycle time 10 seconds/90 115 or 230Vac Duty Cycle 5% standard 115Vac or 230Vac Motor Permanent split capacitor 115Vac/1ph/50-60Hz standard With thermal over load protection L. R. Current 115Vac = 0.75 amps 230Vac = 0.38 amps Enclosure NEMA 4 standard NEMA 7 optional Coating Thermally bonded polyester powder Fasteners Output ISO 5211 F07 Mounting Pad ISO 5211 F07 Brake Power on, standard Position Ind. Visual indicator Weight 24 Lbs. Lubrication Permanent Installation Universal Temp. Range -40 F. to 150 F. Heater & thermostat required 0 F. & below Switches SPDT snap action 16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc ICI s model ES2 electric spring return actuator is a light duty actuator designed for fail-safe applications. It is recommended for applications requiring system protection from unforeseen power failures. This actuator is not recommended for applications requiring several open/close cycles per day. ALLOW 4'' (101.6) FOR COVER REMOVAL ALLOW 4 FOR COVER REMOVAL VISUAL POSITION INDICATOR VISUAL POSITION INDICATOR OPEN 7.1 (180) 1.76 (44.7) MECHANICAL STOP MECHANICAL STOP FAIL CLOSED FAIL CLOSE 3.13 (80) 2.81 (71) 8.5 (216).63 (16) ADDITIONAL 1/2" NPT CONDUIT ENTRY OPTIONAL ADDITIONAL 1/2 NPT CONDUIT ENTRY 1/2".667 (17) CONDUIT ENTRY 1/2 NPT CONDUIT ENTRY 8.5 (216) 3.38 (86) 4, 3/8-16 TAP.56 DP. 4.015 B.C. 4, 3/8-16 TAP.56 DP. 4.015 (102) B.C. 4, 5/16-18 TAP.40 DP. 2.756 B.C. 4, 5/16-18 TAP.4 DP. 2.756 (70) B.C. DIMENSIONS (mm)

13 Torque Cycle time Duty Cycle Motor AS4 400 Lb-In (45.2 Nm) AS6 600 Lb-In (67.8 Nm) AS10 1000 Lb-In (113 Nm) 12 seconds/90 115 or 230Vac 25% standard 115Vac or 230Vac Permanent split capacitor 115Vac/1ph/50-60Hz standard With thermal over load protection L. R. Current 115Vac = 2.91 amps 230Vac = 2.40 amps Enclosure NEMA 4 standard NEMA 7 optional Coating Thermally bonded polyester powder Fasteners Output AS4 & AS6 ISO 5211 F07 = 0.66 Male AS10 = 1.0 Male Mounting Pad ISO 5211 F07 Brake Weight Lubrication Installation Temp. Range Switches Power on, standard AS4 & AS6 = 68 Lbs. AS10 = 78 Lbs. Permanent Universal -40 F. to 150 F. Heater & thermostat required 0 F. & below SPDT snap action 16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc ICI s models AS4, AS6 & AS10 electric spring return actuators are heavy duty actuators designed for fail-safe applications. They are recommended for applications requiring system protection from unforeseen power failures. These actuators are recommended for applications requiring approximately 25 open/close cycles per day.

14 Thrust 200 to 1900 Lbs. (22.6 to 214.7 Nm) Stroke ½ 3 Cycle time 3 IPM Duty Cycle 75% standard 115Vac Motor Permanent split capacitor 115Vac/1ph/50-60Hz standard With thermal over load protection L. R. Current Model 12-2=0.58 amps 115Vac Model 12-5=0.75 amps 115Vac Model 12-10=1.0 amps 115Vac Model 12-19=1.5 amps 115Vac Enclosure NEMA 4 standard Coating Thermally bonded polyester powder Fasteners Captive, Output ISO 5211 F05 Mounting Pad ISO 5211 F05 Brake Friction, standard Power Off (optional) Position Ind. Wired for light indication Weight 16 Lbs. (as shown) Lubrication Permanent Installation Universal Temp. Range -40 F. to 140 F. Heater & thermostat required 0 F. & below Limit Switches SPDT snap action (optional on 4-20mA control) 16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc Potentiometer Linear (optional) Positioner Analog 4-20mA (optional) ALLOW 4" (101.6) FOR COVER REMOVAL TWO POSITION SPRING RETURN SERIES 12 LINEAR ACTUATOR 1'' STROKE SHOWN TWO POSITION SERIES 12 LINEAR ACTUATOR 1'' STROKE SHOWN 21.0 (533.4) 16.5 (419.1) 1/2 N.P.T. CONDUIT ENTRY TYP. 4.0 (101.6) 4.0 (101.6) 1.13 (28.7) 1.13 (28.7) 1.0 (25.4) STROKE 3.13 (79.5) 8.66 (220).998 (25.35) 1.0 (25.4) STROKE.998 (25.35) 1/2-20 TAP 3/4 DP. 7.78 (197.6) 45.0 4, 1/4-20 TAP.44 (11.2) DP. 2.756 (70) B.C. 3.2 (81.28) 2.5 (63.5) 5.5 (127)

15 Thrust Cycle time Duty Cycle Motor 165 Lbs. 9.6 IPM 75% duty cycle Permanent split capacitor 115Vac/1ph/50-60Hz standard With thermal over load protection 12 & 24Vdc available L. R. Current 0.58 amps 115Vac Enclosure NEMA type 4, 4X, 9 & 7 for Class I, Groups C & D, Class II, Groups E, F & G, Division 1 & 2 Hazardous Location. Coating Thermally bonded polyester powder Fasteners Captive, Output Drive Position Ind. 4-20mA optional Weight 20 Lbs. Lubrication Permanent Installation Universal Temp. Range -40 F. to 140 F. Heater & thermostat required 0 F. & below Limit Switches SPDT snap action (optional on 4-20mA control) 16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc Potentiometer Linear Positioner Digital high performance 4-20mA MANUAL OVER RIDE ACCESS NUT 2, 1/2-14 NPT CONDUIT ENTRIES.32 (8.13mm) 7.68 (195.1mm) 9.58 ( 243.3mm) OPTIONAL MANUAL OVER RIDE CRANK HELD IN PLACE BY CLIP 3.33 (8.5mm) Ø 1.3 (33mm).49 1.25(31.8mm) (12.5mm).75 (19.1mm) 1/4-20 UNC-2A 1.0 STROKE (25.4mm) 1 3/4-12 UN-2A THREAD.37 ACROSS FLATS (9.4mm) SOFT STOP FEATURE TO PROTECT VALVE SEAT 2.66 (67.6mm) 5.32 (135.1mm) ICI's linear CV series Control Valve actuators are equipped with high resolution control boards, two 1/2'' NPT conduit entries, soft stop and end of position limit switches. (mm) Dimensions in milimeters 2.87 (72.9mm)

16 (0 to 46 C). Fail-Safe Watts Actuator Series Wire Gage Size 12 10 8 6 4 R 40ft 65ft 75ft 90ft 115ft 300 S, SD, MS & MR 30ft 50ft 60ft 75ft 95ft SX & SDX 25ft 45ft 55ft 70ft 85ft ML & MH 25ft 45ft 55ft 70ft 85ft LA - - 35ft 50ft 65ft 700 LX & 5K - - 30ft 45ft 60ft 7K - - 10ft 25ft 40ft 1000 12K & 14K - - 10ft 25ft 40ft *The above distances should be considered as maximums

17 Indelac s control panels are designed to provide dependable operation as well as meet NEMA 4 specifications. While ICI offers a number of standard control panels we also design special controls for various applications. If your needs do not fall within the realm of our standard control panels please call or email your specifications for design consideration.

18 SERIES SERIES OPTIONS R SD S M L K ES2 AS OPTION R SD S M L K ES2 AS Enclosure NEMA Type 4X Speed Control 12Vdc Type 4 NEMA Type 6 24Vdc Standard NEMA Type 7 24Vac NEMA Type 4 & 7 115Vac Motor 115Vac Ext'ed Duty 230Vac Voltage 24Vac 115Vac 24Vdc Timer 12Vdc Standard 12Vdc 24Vdc 208Vac/1ph/60Hz 24Vac 230Vac/1Ph/60Hz 115Vac 230Vac/3Ph 230Vac 380Vac3Ph/50Hz Multi-Position, Three Position 460Vac/3Ph Vac Four Position Coating Epoxy Coating Multi-Position, Three Position Anodize Vdc Four Position Auxiliary One Position Diamond Switches Two Indicator ICI Dome Three Light Indication Four 4-20mA Transmitter Proximity Limit Three Position 3 3 3 3 3 Switches Two Auxiliary Power Supply 115Vac or 230Vac Declutching NEME Type 4 1 1 1 Two Conduit NEMA Type 4 Man-O-Ride NEME Type 7 Entries NEMA Type 7 Brake, 12Vdc Mechanical Stop Power On 24Vdc Breather 24Vac Heater 115Vac 1 1 Heater & Stat. 230Vac 1 1 Torque Sensor Brake, 12Vdc Multi-Turn Power Off 24Vdc Reversing DC Voltage 24Vac Contactor 3 Ph. Motors 115Vac Transformer 230Vac 2 Wire Control 12Vdc Potentiometer 1K, Single Turn 24Vdc 1K, Single Turn, Dual 24Vac 1K, 3:1 Ratio 115Vac 1K, 0 to 135 ohm 230Vac 1K, Ten Turn Remote Local 5K, Single Turn Control Positioner 12Vdc & 24Vdc 2 24Vac 1. Standard equipment 115Vac 2 2. Assembled in SD enclosure 230Vac 2 3. Third party vendor 115Vac High Resolution 0-135 ohm

19 Torque (T) is any force about a given axis that produces rotation as a moment. The magnitude of the moment is the product of the force (F) and the perpendicular distance (D) from the line of action of the force to the axis, T=F x D. Simply put torque is generated by a twisting force which produces rotation about an axis. Ft Lb 12 = In Lb Ft Lb 1. 36 = Nm In Lb. 113 = Nm TORQUE CONVERSIONS Ft-Lb In-Lbs. Nm 1 12 1.36 5 60 6.80 10 120 13.60 20 240 27.20 40 480 54.40 80 960 108.80 100 1200 136.00 200 2400 272.00 400 4800 544.00 600 7200 816.00 800 9600 1088.00 1000 12000 1360.00 Duty cycle is the ratio of actuator on time to off time and is used to determine the proper actuator for a specific application. It is also used to determine an acceptable operating time so that the thermal over load in the motor is not exceeded during valve or damper automation. Actuator inefficiencies cause the motor temperature to rise and at a critical temperature the thermal over load is activated and the actuator is shut down. The actuator is inoperative (undesirable in most applications) for a period of time allowing the motor to cool and the thermal over load to reset. Duty Cycle = DC, On Time = ON and Off Time = OFF DC = (ON/ON + OFF) x 100 For example: ICI s standard model SD has a 5 second cycle time and is rated at 25% duty cycle. This means that the off time must be at least 15 seconds, hence: ON = 5, OFF = 15 DC = (5/5+15) x 100 DC = (5/20) x 100 DC = 0.25 x 100 DC = 25% Model SD with an extended duty motor has a 10 second cycle time and is rated at 75% duty cycle. This means that the off time must be at least 3.333 seconds, hence: ON = 10, OFF = 13.333 DC = (10/10+3.333) x 100 DC = (10/13.333) x 100 DC = 0.75 x 100 DC = 75% This formula can be used to determine the off time of an actuator if the cycle time and duty cycle are known. OFF = (ON/DC)-ON

20 The powder coating used on all ICI electric actuators must: 1. Be Corvel Royal Blue #20-5005 or equivalent. 2. Be TGIC Polyester 3. Have excellent gloss pretension. 4. Provide excellent adhesion. 5. Provide good edge coverage and chip resistance. 6. Provide excellent exterior durability and resistance to the suns UV rays. 7. Provide good salt spray protection. 8. Provide flexibility and hardness to assure protection against high impact. 9. Offer a high degree of resistance to corrosion. 10. Offer a high degree of protection against chemicals and solvents. Hardness Flexibility Overbake Stability Exterior Durability Corrosion Protection Chemical/Solvent Resistance Ease of Application Epoxy Hybrid Aromatic Urethane Aliphatic Urethane TGIC Polyester Polyester Wrinkle Non-TGIC Polyester *The binder is the all important solid material that forms the bulk of the powder coating. The above graphic representation gives the relative properties of some common powder binder types. Not Good Fair Good Very Good Best Model 12Vdc 24Vdc 24Vac 115V-1Ph 230V-1Ph 230V-3Ph 460V-3Ph FL LR FL LR FL LR FL LR FL LR FL LR FL LR R 0.6 2.9 0.4 2.4 0.4 2.4 0.55 0.38 N/A N/A N/A N/A SR 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A SX 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A SD 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A SDX 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A MR 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A MS 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A ML 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A MH 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A LA 6.9 48 3.7 25 3.7 25 0.98 1.5 1.03 2.4 N/A N/A N/A N/A LX 6.9 48 3.7 25 3.7 25 1.09 2.9 1.03 2.4 N/A N/A N/A N/A 5K 6.9 48 3.7 25 3.7 25 1.09 2.9 1.03 2.4 1.26 4.3 0.5 1.9 7K 6.9 48 3.7 25 3.7 25 2.8 7.1 1.03 2.4 1.26 4.3 0.5 1.9 12K 2.8 7.1 1.03 2.4 1.26 4.3 0.5 1.9 14K 2.8 7.1 1.03 2.4 1.26 4.3 0.5 1.9 27K Note: 24Vac units are 24Vdc motors rectified for 24Vac use. FL=Full 2.8 Load Current, 7.1 LR=Lock 1.03 Rotor 2.4 Current 1.26 4.3 0.5 1.9

21 ICI manufactures compact quarter turn electric actuators. The word compact defines the torque range below 10,000 lb-in (1130 Nm). While we do offer larger torque actuators and different style actuators like multi-turn actuators (actuators rotating more than 360 degrees) and linear actuators (actuators drive that move axially instead of rotary) our niche is in the compact quarter turn market. ICI actuators are used for on-off service (valve operated to full open/close position to start or stop flow) as well as modulating service (valve positioned to throttle or regulate flow). In the electric actuator world a limit switch is the device that controls the end position of the actuator, the actuator limits. This term is often confused with a limit switch that is used on pneumatic actuators to transmit valve position. When using electric actuators the pneumatic limit switch option is known of as auxiliary switches, extra limit switches or auxiliary limit switches. Contrary to pneumatic actuators where the limit switch is mounted externally with an electric actuator the auxiliary limit switches are installed inside the actuator enclosure. Actuator limits for compact quarter turn electric actuators are normally 0 (closed) and 90 (open) degrees. ICI electric actuators are equipped with manual over rides. A manual over ride allows the user to rotate the valve manually in the event of a power failure. Our 400 lb-in (45.2 Nm) actuators and larger are equipped with declutching manual over rides. Declutching manual over rides disengage from the gear train enabling the user to turn the valve with greater ease. ICI also manufactures a line of electric fail-safe devices which are battery back up systems that invert 12Vdc battery power to 115Vac square sine wave power upon unexpected loss of main supply power allowing standard actuators to operate valves open or close in an emergency. Flange Type Female Drive Bolt Circle F03 9mm (.354" Sq.) 36mm (1.417" Sq.) F04 11mm (.433" Sq.) 42mm (1.654" Sq.) F03/F04 (Flange Not ISO) 9mm (.354" Sq.) 42mm (1.654" Sq.) F05 14mm (.551" Sq.) 50mm (1.969" Sq.) F07 17mm (.669" Sq.) 70mm (2.756" Sq.) F10 22mm (.866" Sq.) 102mm (4.016" Sq.) F12 27mm (1.063" Sq.) 125mm (4.921" Sq.) F14 36mm (1.417" Sq.) 140mm (5.512" Sq.) F16 46mm (1.811" Sq.) 165mm (6.496" Sq.) F25 55mm (2.165" Sq.) 254mm (10.000" Sq.) F30 75mm (2.953" Sq.) 298mm (11.732" Sq.) * The a dimensions above were taken from the International Standard ISO 5211 First edition 2001-02-15 and are only a small representation of the information available in International Standard ISO 5211. = 5 32 9 = 9 5 + 32 IP Code Min. NEMA Rating IP65 4,4X IP67 6 IP68 6P TYPE 1 TYPE 4 TYPE 4X TYPE 6 TYPE 7 TYPE 9 General purpose intended for indoor use to prevent accidental contact with enclosed equipment. Water and dust tight intended for indoor or outdoor use to protect enclosed equipment from splashing water, seeping of, falling or hose directed water and severe external condensation, they are sleet proof. Water and dust tight with same provisions as Type 4 enclosure but also are corrosion resistant. Water and dust tight sleet resistant intended for indoor or outdoor use where occasional submersion may be encountered with a static head of no more then 6 feet for no longer then 30 minutes. Class I, Division 1 and 2, Groups A, B, C or D intended for indoor hazardous locations. Division 1: Hazardous vapors are present. Division 2: Hazardous contained but may not be present. Groups A, B, C & D classifies different gases and vapors. Class II, Division 1 and 2, Groups E, F or G intended for indoor hazardous locations. Division 1: Air suspended dust. Division 2: Surface accumulated non-air suspended. Groups E, F & G classifies different dust types.

ORDERING INFORMATION WHEN ORDERING PLEASE SPECIFY THE FOLLOWING: 1. QUANTITY REQUIRED 2. MODEL NUMBER OR ACTUATOR SERIES 3. ENCLOSURE RATING NEMA TYPE 4 NEMA TYPE 4X NEMA TYPE 7 NEMA TYPE 4, 7 & 9 4. ELECTRICAL REQUIREMENTS VOLTAGE HERTZ PHASE 5. OUTPUT TORQUE ALLOW 25% SAFETY FACTOR 6. OPTIONAL EQUIPMENT REQUIRED OPTIONS ARE AVAILABLE FOR MOST APPLICATIONS, 7. DESIRED SHIP DATE IF YOU HAVE QUESTIONS REGARDING THE APPLICATION PLEASE CONTACT OUR SALES SPECIALIST. IF WE KNOW YOUR SCHEDULE WE WILL TRY TO MEET IT, IF WE DO NOT THE ORDER WILL DEFAULT TO OUR SCHEDULE. RECOMMENDED SPARE PARTS 1. One set of limit switches. 2. Capacitors for R through M Series. 3. Potentiometer for modulating actuators. ICI SALES TEAM US SALES DEBBIE VOGES EXT: 100 DVOGES@INDELAC.COM INTERNATIONAL SALES MATT ROBINSON EXT: 109 MROBINSON@INDELAC.COM CUSTOMER SERVICE BOB KRAMER EXT: 108 RKRAMER@INDELAC.COM GENERAL CONTACT PHONE 1-8 5 9-727- 7890 TOLL FREE PHONE 1-8 0 0-662- 9424 FAX 1-8 5 9-727- 4070 ADDRESS 6810 POWERLINE DR. FLORENCE KY, 41042 USA VISIT US ONLINE! w w w. i n d e l a c. c o m