Care and use guide. Contents. page

Similar documents
Care and use guide Guía de uso y cuidado Guide d utilisation et d entretien.

Care and use guide. Contents. page

Care and use guide. Contents. page

Power. On Your Terms.

10 Year Limited Warranty

COM-100 EC / TDS / TEMPERATURE METER

Installation / Operation Instructions Sunnex ORION Series Exam Lights

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Care and Use Guide. Bluelab PeriPod M3. Bluelab PeriPod L3. 6 months for pumps and tubes

SOARER TT BLOW-OFF VALVE ADAPTOR INSTRUCTIONS

PVI 60KW, PVI 82KW, PVI 95KW

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

This manual covers the following model:

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Warranty Information North America

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Thermaltake Warranty / Support Information

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

To assemble your equipment read entire manual and follow all instructions.

Model FM2642 Wall Mount. Full Motion Television Wall Mount

Grape Solar STAR Series Connection Guide Copyright 2012, Grape Solar, Inc. All Rights Reserved

RANGE HOODS USER INSTRUCTIONS

HOW TO INSTALL YOUR BOV

HOW TO INSTALL YOUR BOV

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING


FREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

SUPRA JZA80 TWIN TURBO BLOW-OFF VALVE ADAPTOR INSTRUCTIONS

PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON.

Instant Wine Aerator USER MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

SYSTEM CONTROL KIT. Model: CK-41F. Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances.

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

Premium Pond Pump 330 Gallons Per Hour

Digital Clock model 75100C

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Cabling for power, control, and video must be run to the installation site before the mount is installed.

NEW GEN OWNER S MANUAL

PowerFLEX Module Limited Warranty Program

Owner s Installation Guide

30100 Module Installation Guide L

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

Premium Waterfall Pump 1200 Gallons Per Hour

Installation Power Management Unit Battery Cables and Battery Harness

LT-EL138 LED Flashlight

Series 2100 Operating Instructions

Fitting Instruction for EZI-GRIP Bike Rack

ELECTRONIC FIREPLACE DAMPER

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

Thermometer models / 00831A

2060F / 2062F / 2064F

CONTENTS. Introduction. Thank you for purchasing the AlcoSense Precision+ breathalyser.

15100 Module Installation Guide Mercedes EPA07 w/dpf

ASSEMBLY / OPERATION INSTRUCTIONS. Low Profile Motorcycle Dolly

Natural Fiber Planter Fountain

Intelligent Electronic Safe

ValveSentry USER S MANUAL REVISED 8/6/16 IMPORTANT! PLEASE READ CAREFULLY AND SAVE

Submersible Waterfall Pump 1200 Gallons Per Hour

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

IAQ-CALC TM Indoor Air Quality Meter

WARNING. Instructions for Guidelights and Chargers. How SnapPower Products Work

PRO JACK 4500 ROLLING BRIDGE JACK 4,500 POUND CAPACITY. PARTS MANUAL P/n NRJ450BK

Container Fountain Kit with LED Light

Toro Sprayer Calibration Tool

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

Submersible Pond Pump with UV 800 Gallons Per Hour

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

User s Manual Chase on the Case Cruiser

Read and follow all instructions. Safety can only be ensured if the walker is assembled and operated according to these instructions.


Vertabelo Academy. Terms of Service PLEASE READ ALL OF THE FOLLOWING TERMS OF SERVICE BEFORE USING THIS WEBSITE A. General Terms

CU6703 Module Installation Guide

Wireless Thermometer model 00380

20250 Module Installation Guide

Franklin Fueling Systems

AD-7 THERMAL INDICATING AMMETER

Window Thermometer models / / 00423

11 GALLON PORTABLE AIR TANK

Submersible Waterfall Pump 1250 Gallons Per Hour

User Guide IGD Series

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

Nature s Generator Power Panel

Accessory ACCESSORY User Manual

SANTA CRUZ BICYCLES MY18 Hightower Suspension Setup

Assembly Instructions

Model P-40 & Model P-25 POWER PUSHER

Slimline Duals Installation Instructions Harley-Davidson Touring Models 2009-Current

Installation Guide. Marine Filter SURT023M SURT024M

Cummins N14 Celect & Celect Plus Engine Module. For Agricultural Applications Only. Part # 31200

Female Plug. connecting to Fuel Quantity

II DISTRIBUTION & SUBSTATION TYPE C

PASSENGER AND LIGHT TRUCK TIRE LIMITED WARRANTY AND ADJUSTMENT POLICY

Transcription:

Care and use guide Contents page Features 2 To operate 2 Cleaning and maintenance 3 Battery replacement 3 Troubleshooting guide 4 Technical specifications 4 Information about the scales available on the Bluelab Truncheon Nutrient Meter 5 Bluelab measurement conversion chart 6 Bluelab limited warranty 7 Contact details 8

English Features Blueglow light display Provided with EC, CF and ppm scales Fully guaranteed for 5 years (with proof of purchase) 1.0 To operate No calibration required Fully waterproof Auto turn on/off function Using the Bluelab Truncheon Nutrient Meter to measure nutrient conductivity involves placing the probe sensor head in the solution, followed by measuring and reading conductivity values on the stem scale indicator light. Figure 1 shows the Bluelab Truncheon Nutrient Meter (Truncheon Meter). Figure 1. Bluelab Truncheon Nutrient Meter Stem Scale Probe Value indicator light 1 Measure conductivity Place probe into nutrient solution and take reading as indicated by the flashing lights. Note: If the lights are dancing between two values, the reading is between those two values eg. lights dancing between 6 and 8 indicates a reading of 7. Note: For very cold or very hot temperatures it will take 1-2 minutes for the probe to reach solution temperature. To help decrease time taken to reach the solution temperature, place the probe in an area where there is a strong movement of solution, or stir solution with the probe. 2 Obtain another reading To take another reading, simply place back in solution. 3 Clean probe We recommend the probe be cleaned once every two weeks according to the Cleaning and Maintenance instructions. This can vary depending on frequency of use. 2

English 2.0 Cleaning and maintenance Cleaning the Truncheon Meter probe frequently ensures accurate readings. Clean the probe with a liquid scourer cream used in home bathrooms and kitchens such as Jif, Liquid Vim, Soft Scrub, Cif, or Viss. Never use scented varieties of cleaner as they affect the probe functions. 1 Remove shroud Twist the shroud 90 degrees and then remove the shroud. Twist Remove 2 3 4 Clean probe face Place one or two drops of unscented liquid scourer, such as Jif, Liquid Vim, Soft Scrub, Cif, or Viss on the probe face. Rub probe face with your finger or Bluelab Chamois firmly and vigorously to clean. Rinse probe Rinse off all traces of cleaner under running water using the same finger or other side of Bluelab Chamois. Check that the water forms a film on the probe face with no beads of water. If beading is present repeat the cleaning process. Replace shroud 3.0 Battery replacement The Truncheon Meter is powered with 3 x AA type standard or alkaline batteries. Do not use rechargeable batteries. Do not mix brands of batteries. Do not mix old with new. Do not put upside down. Follow these steps to replace the batteries. 1 Remove old batteries Unfasten battery cap and tip out old batteries. 2 3 Check for corrosion Batteries that have been inside the unit for a long length of time may corrode. Check battery contacts and batteries for any sign of corrosion. Contacts should be cleaned first if corrosion is found before proceeding to step 3. Fit new batteries Insert the new batteries positive (+) end down into the body. 3 4 Replace battery cap Refasten battery cap. There must be no space left between the cap and body to ensure the unit remains 100% waterproof.

4.0 Troubleshooting guide Trouble Correction English Truncheon Meter turns off before reading taken. Take out of solution for 3-5 seconds. Dip in solution again and take reading. Truncheon Meter not lighting when dipped in solution. Clean the probe. If this is unsuccessful, replace batteries. Do not use rechargeable batteries. Truncheon Meter gives low readings. Clean the probe. Ensure unscented cleaner is used eg. plain Jif, Soft Scrub, Liquid Vim, Cif or Viss. 5.0 Technical specifications Range 2 36 CF 140 2520 ppm (EC x 700) 0.2 3.6 EC 100 1800 ppm (EC x 500) Resolution 1 CF, 0.1 EC, 70 ppm (700), 50 ppm (500) Accuracy ± 0.1 EC, ± 1 CF, ± 50 ppm (1385 ppm at 500 ppm), ± 70 ppm (1939 ppm at 700 ppm) Temperature compensation Automatic Operating temperature 0-50 C, 32-122 F Calibration Factory calibrated Limitation of Liability 4 Under no circumstances shall Bluelab Corporation Limited be liable for any claims, losses, costs and damages of any nature whatsoever (including any consequential loss) that result from the use of, or the inability to use, these instructions.

Information about the scales available on the Bluelab Truncheon Nutrient Meter CF and EC English CF and EC are measures of electrically charged nutrient ions in a solution. Pure water will not conduct electricity. Water usually conducts electricity because it is full of impurities, in our case, electrically charged nutrient ions. The two black dots on the end of a nutrient probe are called electrodes. When these are placed in a solution, an electrical current passes from one electrode, through the water to the other electrode and counts the number of electrically charged ions present. This represents the units measured - EC or CF. ppm measures parts per million There are many different scales used for different industries around the world and for many different reasons! Did you even know there are more than two scales? The most widely used scales in Hydroponics are the 500 scale, 650 scale and the 700 scale. What s the difference? The ppm 500 scale is based on measuring the KCl or potassium chloride content of a solution. The ppm 700 is based on measuring the NaCl or sodium chloride content of a solution. Individual nutrient ions have different electrical effects! The true ppm of a solution can only be determined by a chemical analysis. ppm cannot be accurately measured by a CF or EC meter. They are present on Bluelab products as a conversion guide only. The conversion is as follows; 2.4 EC x 500 = 1200 ppm (500 scale) or 1200 ppm / 500 = 2.4 EC 2.4 EC x 700 = 1680 ppm (700 scale) or 1680 ppm / 700 = 2.4 EC If you are wanting to measure your solution in ppm, you will need to know the following: What ppm scale is your meter using? Which calibration standard should you use for your meter? What ppm scale is your nutrient referring to? 5

English 6 Bluelab Measurement Conversion Chart ms/cm 2 Millisiemen per cm 2 EC CF ppm 500 TDS ppm 700 0.1 0.1 1 50 70 0.2 0.2 2 100 140 0.3 0.3 3 150 210 0.4 0.4 4 200 280 0.5 0.5 5 250 350 0.6 0.6 6 300 420 0.7 0.7 7 350 490 0.8 0.8 8 400 560 0.9 0.9 9 450 630 1.0 1.0 10 500 700 1.1 1.1 11 550 770 1.2 1.2 12 600 840 1.3 1.3 13 650 910 1.4 1.4 14 700 980 1.5 1.5 15 750 1050 1.6 1.6 16 800 1120 1.7 1.7 17 850 1190 1.8 1.8 18 900 1260 1.9 1.9 19 950 1330 2.0 2.0 20 1000 1400 2.1 2.1 21 1050 1470 2.2 2.2 22 1100 1540 2.3 2.3 23 1150 1610 2.4 2.4 24 1200 1680 2.5 2.5 25 1250 1750 2.6 2.6 26 1300 1820 2.7 2.7 27 1350 1890 2.8 2.8 28 1400 1960 2.9 2.9 29 1450 2030 3.0 3.0 30 1500 2100 3.1 3.1 31 1550 2170 3.2 3.2 32 1600 2240 3.3 3.3 33 1650 2310 3.4 3.4 34 1700 2380 3.5 3.5 35 1750 2450 3.6 3.6 36 1800 2520

Bluelab limited warranty Bluelab Corporation Limited (Bluelab) provides a warranty on its products (Bluelab Truncheon Nutrient Meter ) under the following terms and conditions: English 7 How Long Does Coverage Last? Bluelab warrants the Bluelab Truncheon Nutrient Meter (Product) for a period of 60-months from date of purchase by original purchaser or consumer. Proof of purchase, to Bluelab s sole satisfaction, is required for the warranty to be effective (store sales receipt for Product showing model number, payment and date of purchase). This warranty is non-transferable and terminates if the original purchaser/consumer sells or transfers the Product a third party. What is Covered? Bluelab warrants the Product against defects in material and workmanship when used in a normal manner, in accordance with Bluelab instruction manuals. If Bluelab is provided with valid proof of purchase (as defined above) and determines the Product is defective, Bluelab may, in its sole discretion either (a) repair the Product with new or refurbished parts, or (b) replace the Product with a new or refurbished Product. Any part or Product that is replaced by Bluelab shall become its property. Further, if a replacement part or Product is no longer available or is no longer being manufactured, Bluelab may at its sole discretion replace it with a functionally-equivalent replacement part or product, as an accommodation in full satisfaction of the warranty. What is NOT covered? This warranty does not apply to equipment, component or part that was not manufactured or sold by Bluelab, and shall be void if any such item is installed on a Product. Further, this warranty does not apply to replacement of items subject to normal use, wear and tear and expressly excludes: Cosmetic damage such as stains, scratches and dents Damage due to accident, improper use, negligence, neglect and careless operation or handling of Product not in accordance with Bluelab instruction manuals, or failure to maintain or care for Product as recommended by Bluelab Damage caused by use of parts not assembled/installed as per Bluelab instructions Damage caused by use of parts or accessories not produced or recommended by Bluelab Damage due to transportation or shipment of Product Product repaired or altered by parties other than Bluelab or its authorised agents Product with defaced, missing or illegible serial numbers Products not purchased from Bluelab or a Bluelab -authorised distributor or reseller. How Do You Get Service? To begin a warranty claim you must return the Product to the point of purchase with valid proof of purchase (as defined above). In California, you can also return the Product to any Bluelab-authorised distributor or reseller, with valid proof of purchase. Limitation of Liability & Acknowledgments TO THE MAXIMUM EXTENT PERMITTED BY LAW, THIS WARRANTY AND THE REMEDIES SET OUT ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, GUARANTEES AND REMEDIES (ORAL OR WRITTEN, EXPRESS OR IMPLIED). EXCEPT AS PROVIDED IN THIS WARRANTY AND TO THE MAXIMUM EXTENT PERMITTED BY LAW, BLUELAB IS NOT RESPONSIBLE FOR SPECIAL, INCIDENTIAL OR CONSEQUENTIAL LOSS OR DAMAGES, OR ANY OTHER LOSS OR DAMAGES RESULTING FROM SALE OR USE OF THE PRODUCT, OR BREACH OF WARRANTY, HOWEVER CAUSED, INCLUDING DAMAGES FOR LOST PROFITS, PERSONAL INJURY OR PROPERTY DAMAGE. IT IS UNDERSTOOD AND AGREED BY CONSUMER UPON PURCHASE OF A PRODUCT THAT, EXCEPT AS STATED IN THIS WARRANTY, BLUELAB IS NOT MAKING AND HAS NOT MADE ANY EXPRESS OR IMPLIED WARRANTY OR OTHER REPRESENTATION REGARDING THE PRODUCT, AND DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW. ANY WARRANTIES WHICH ARE IMPOSED BY LAW AND CANNOT BE DISCLAIMED ARE HEREBY LIMITED IN DURATION TO THE PERIOD AND REMEDIES PROVIDED IN THIS WARRANTY. SOME JURISDICTIONS (STATES OR COUNTRIES) DO NOT ALLOW EXCLUSION OR LIMITATION FOR INCIDENTIAL OR CONSEQUENTIAL DAMAGES, OR LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT BE APPLICABLE. IF ANY PROVISION OF THIS WARRANTY IS JUDGED TO BE ILLEGAL, INVALID OR UNENFORCEABLE, THE REMAINING PROVISIONS OF THE WARRANTY SHALL REMAIN IN FULL FORCE AND EFFECT. Governing Law; Authority This warranty is governed by the laws of the state of country where Product is purchased, without regard to its choice of law principles. Except as allowed by law, Bluelab does not limit or exclude other rights a consumer may have with regard to the Product. No Bluelab distributor, employee or agent is authorised to modify, extend or otherwise change the terms of this warranty. Register your guarantee online at bluelab.com

guarantee. The Bluelab Truncheon Nutrient Meter comes with a 5 year limited written guarantee. Proof of purchase required. lets talk. If you need assistance or advice - we re here to help you. North America Ph: 909 599 1940 NZ Ph: +64 7 578 0849 Fax: +64 7 578 0847 Email: support@bluelab.com get online. Looking for specifications or technical advice? Visit us online at bluelab.com or facebook.com/getbluelab post. Bluelab Corporation Limited 8 Whiore Avenue, Tauriko Business Estate Tauranga 3110, New Zealand Instruction Manual English TRUNV2_V02_190916 Copyright 2011, all rights reserved, Bluelab Corporation Limited