SECONDARY 600 VOLT CABLES

Similar documents
ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

CONDUCTOR WESTERN UNITED ELECTRIC SUPPLY

ACSR BARE ALUMINUM OVERHEAD CONDUCTOR RATED STRENGTH LBS 240 LB COIL FT AMPS (1) PARTRIDGE / , ,795

Multiplex Overhead Aluminum Service Cable Specification ICEA Standard S General Cable Specification Sheet #AC-0004 and #AC-0006

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

ELE CTR IC UT ILI TY

High Voltage Copper, Smooth Aluminum Shield/Sheath

TC-RHH/RHW-2 USE-2 Copper

Primary, Secondary, Post-Secondary Education Facilities

Medium Voltage Cable. marmonutility.com

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

Electric Utility ENERGY PRODUCTS FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

MC or MV-105 Copper, TR-XLPE Insulated

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

STABILOY BRAND FeeDeR SOLuTIONS

Category # 1 - Overhead, Primary, & Secondary Conductors

MC, THHN/THWN-2 Copper

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES


Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

MEDIUM VOLTAGE

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

SB ELECTRICAL WIRE

NEC 2014 Code Changes

DLO. Mining Cable. Mining Cable. 2 kv

Section 11 Mining Cable

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

RENEWABLE ENERGY. Alcan cable solutions

ATHLETIC STADIUMS AND SPORTS ARENAS

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Outdoor Power Transmission & Distribution

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

HOSPITAL AND HEALTHCARE

Mecklenburg County Common Code Defects

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Type P Drilmar 125-XE Signal & Instrumentation

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

Type P Drilmar 125-XE Signal & Instrumentation

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Additional Information TRADE NAME PERIWINKLE; STRANDING 7 (PHASE), 6/1 (NEUTRAL); WEIGHT 272 LB PER 1000 FT

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

Medium Voltage Power Cables

Quintas & Quintas Group

Electrical Design/Build Guide

ANSI/NEMA WC ICEA No. S Portable and Power Feeder Cables for Use in Mines and Similar Applications

Type MMV-WP Medium Voltage Wind Power Cable

Easier! Faster! Safer!

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

TRANSMISSION SYSTEMS

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

Power & Control Cables. U o. /U 0.6/1 kv - IEC

SECTION 300 OVERHEAD SERVICE

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

CAAI-S 0,6/1 kv with Public Lighting

KALAS ENTERTAINMENT CABLE

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

Volume 2 Charts, Formulas, and Other Useful Information

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Open-Style Power Distribution Blocks

N2XY IEC XLPE PVC 0.6/1kV Cable

TUNNELING POWER CABLES

Electronic Instrumentation

Medium Voltage Cables for PermaLife Nuclear Utility Applications

DUCT-O-BAR HD Series Conductor Systems 500, 1000 & 1500 Ampere Sizes

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Power & Control Cables

Connector Installation Guide Compression and Mechanical Connectors

Transmission & Distribution Glossary of Electrical Terms

Generator Fire Safety: Generator assemblies should be located outside the building.

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

Airfield Ground Lighting

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

Automotive Cables. The Global Cable Solutions Company

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

General Specifications for Lighthouse Power Pedestal

Spring Test 10 due 05/11/2013

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

SINGLE PHASE WIRING SPECIFICATIONS

Transcription:

ALUMINUM UNDERGROUND SECONDARY 600 VOLT CABLES Black Crosslinked Polyethylene (XLPE) with and without TRISTRIPE grounded in service wired to innovate TM

Alcan Aluminum Underground Secondary 600 Volt Cables: Alcan Cable s Underground Secondary 600 Volt Cables provide outstanding performance and reliability. Alcan provides a full range of underground 600 volt cables available as single conductor or with one, two or three phase conductors and a neutral twisted together, with no overall cover. The neutral conductor is equal in size to, or two sizes smaller than the phase conductors. Product Application and Features: Designed for use in electric distribution circuits not exceeding 600 volts phase to phase and may be directly buried or installed in ducts. May be used in wet or dry locations at conductor temperatures not exceeding 90 C for normal operation, 130 C for emergency overloads and 250 C under short circuit conditions. Meets or exceeds industry requirements per ASTM B-231. To ensure exceptional product quality, Alcan underground 600 volt cable meets or exceeds requirements of ICEA S-105-692. Product Construction: Alcan Underground Secondary 600 Volt Cables are constructed of: Hard drawn Class B stranded compressed 1350 aluminum conductors. Three quarter hard (H26)1350 aluminum per ASTM B609 is available upon request. Black crosslinked polyethylene insulation on the phase conductors. TRISTRIPE cable features a neutral conductor that is insulated with black, weather resistant crosslinked polyethylene with three continuous extruded yellow polyethylene stripes located 120 apart. The identification stripes are weather resistant. In multiplexed cable assemblies, the phase conductors and neutral are twisted together with a left-hand lay not greater than 60 times the outside diameter of one phase conductor. Product Markings: Each conductor will display the following surface markings: Alcan (Plant of Manufacture), conductor size, AL 600V 90 C XLPE (Year of Manufacture). The center aluminum wire in each stranded conductor is indent printed Alcan (Plant of Manufacture) (Year of Manufacture). Sequential footage markings are printed every two feet on one phase conductor to ensure length measurement accuracy. USE-2 per U.L. 854 available upon request.

UNDERGROUND SECONDARY 600 VOLT CABLES Single Aluminum Conductor Size Insulation O.D. LBS./1000 FT. Directly Package Code Word Mils Inches Aluminum Total Buried (Ft.) PRINCETON/XLP 6 60 0.298 25 44 108 2000 MERCER/XLP 4 60 0.345 39 63 140 2000 CLEMSON/XLP 2 60 0.403 62 92 180 2000 KENYON/XLP 1 80 0.473 78 121 203 1000 HARVARD/XLP 1/0 80 0.512 99 146 231 1000 YALE/XLP 2/0 80 0.555 125 177 263 1000 TUFTS/XLP 3/0 80 0.603 157 215 299 1000 BELOIT/XLP 4/0 80 0.658 198 263 338 1000 HOFSTRA/XLP 250 95 0.732 234 314 368 1000 GONZAGA/XLP 300 95 0.784 281 367 407 1000 RUTGERS/XLP 350 95 0.831 328 420 444 1000 DARTMOUTH/XLP 400 95 0.875 376 476 475 1000 EMORY/XLP 500 95 0.956 469 577 540 1000 DUKE/XLP 600 110 1.060 562 697 595 1000 FURMAN/XLP 700 110 1.127 656 804 645 1000 SEWANEE/XLP 750 110 1.159 703 853 667 1000 FORDHAM/XLP 1000 110 1.304 937 1108 800 1000 Duplexed Aluminum Conductor Black Neutral TRISTRIPE Size Insulation Mils O.D. LBS./1000 FT. Directly Package Code Word Phase Neutral Phase Neutral Inches Aluminum Total Buried (Ft.) CLAFLIN/XLP/EYS 6 6 60 60 0.596 49 89 112 2000 DELGADO/XLP/EYS 4 4 60 60 0.690 79 127 146 2000 EVERETT/XLP/EYS 2 2 60 60 0.806 125 185 187 2000 * Ampacities are based on 90 C conductor temperature, 20 C ambient RHO-90 earth, for cables buried 36 deep, only the phase conductors carrying current, 100% load factor. DO NOT USE THESE FIGURES FOR NEC APPLICATIONS. This catalog is intended to provide introductory technical data to aid the correct selection of wire and cable for permanent installation. Wire and cable products supplied by Alcan comply with the codes, standards and product specifications as indicated in this catalog. Weights and measurements are subject to manufacturing tolerances and product design changes. Consequently, Alcan does not accept responsibility for costs incurred by a purchaser as a result of weights and measurements not conforming exactly to those indicated.

Triplexed Aluminum Conductor Black Neutral TRISTRIPE Size Insulation Mils O.D. LBS./1000 FT. Directly Package Code Word Phase Neutral Phase Neutral Inches Aluminum Total Buried (Ft.) ERSKINE/XLP/EYS 6 6 60 60 0.642 74 133 100 1000 VASSAR/XLP/EYS 4 4 60 60 0.742 118 191 130 1000 STEPHENS/XLP/EYS 2 4 60 60 0.830 164 248 168 1000 RAMAPO/XLP/EYS 2 2 60 60 0.867 187 277 168 1000 BRENAU/XLP/EYS 1/0 2 80 60 1.039 261 385 219 1000 BERGEN/XLP/EYS 1/0 1/0 80 80 1.103 298 439 219 1000 CONVERSE/XLP/EYS 2/0 1 80 80 1.144 330 476 249 1000 HUNTER/XLP/EYS 2/0 2/0 80 80 1.196 376 533 249 1000 HOLLINS/XLP/EYS 3/0 1/0 80 80 1.241 415 578 284 1000 ROCKLAND/XLP/EYS 3/0 3/0 80 80 1.299 474 647 284 1000 SWEETBRIAR/XLP/EYS 4/0 2/0 80 80 1.352 524 705 322 1000 MONMOUTH/XLP/EYS 4/0 4/0 80 80 1.418 598 792 322 1000 PRATT/XLP/EYS 250 3/0 95 80 1.497 629 847 356 1000 WESLEYAN/XLP/EYS 350 4/0 95 80 1.687 859 1109 431 1000 NEWARK/XLP/EYS 350 350 95 95 1.791 984 1267 431 1000 RIDER/XLP/EYS 500 350 95 95 1.978 1271 1583 525 1000 WESTCHESTER/XLP/EYS 500 500 95 95 2.060 1412 1740 525 1000 FAIRFIELD/XLP/EYS 750 500 110 95 2.371 1884 2294 615 1000 Quadruplexed Aluminum Conductor Black Neutral TRISTRIPE Size Insulation Mils O.D. LBS./1000 FT. Directly Package Code Word Phase Neutral Phase Neutral Inches Aluminum Total Buried (Ft.) TULSA/XLP/EYS 4 4 60 60 0.833 157 254 119 1000 DYKE/XLP/EYS 2 4 60 60 0.938 227 341 153 1000 WITTENBERG/XLP/EYS 2 2 60 60 0.973 250 370 153 1000 NOTRE DAME/XLP/EYS 1/0 2 80 60 1.176 361 532 198 1000 PURDUE/XLP/EYS 1/0 1/0 80 80 1.236 397 586 198 1000 SYRACUSE/XLP/EYS 2/0 1 80 80 1.293 455 654 226 1000 LAFAYETTE/XLP/EYS 2/0 2/0 80 80 1.340 502 710 226 1000 SWARTHMORE/XLP/EYS 3/0 1/0 80 80 1.404 574 794 257 1000 DAVIDSON/XLP/EYS 3/0 3/0 80 80 1.456 632 863 257 1000 WAKE FOREST/XLP/EYS 4/0 2/0 80 80 1.530 724 969 291 1000 EARLHAM/XLP/EYS 4/0 4/0 80 80 1.589 798 1056 291 1000 RUST/XLP/EYS 250 3/0 95 80 1.695 865 1162 319 1000 SLIPPERY ROCK/XLP/EYS 350 4/0 95 80 1.910 1181 1531 385 1000 NIAGARA/XLP/EYS 350 350 95 95 2.006 1318 1690 385 1000 WOFFORD/XLP/EYS 500 350 95 95 2.237 1742 2163 467 1000 * Ampacities are based on 90 C conductor temperature, 20 C ambient RHO-90 earth, for cables buried 36 deep, only the phase conductors carrying current, 100% load factor. DO NOT USE THESE FIGURES FOR NEC APPLICATIONS.

RESISTANCE INDUCTIVE REACTANCE Code Word Phase Neutral 25 C 50 C 75 C X1 ERSKINE 6 6 0.6725 0.7392 0.8059 0.0337 VASSAR 4 4 0.4227 0.4645 0.5064 0.0335 STEPHENS 2 4 0.2655 0.2929 0.3182 0.0319 RAMAPO 2 2 0.2655 0.2929 0.3182 0.0315 BRENAU 1/0 2 0.1671 0.1837 0.2002 0.0301 BERGEN 1/0 1/0 0.1671 0.1837 0.2002 0.0301 CONVERSE 2/0 1/0 0.1326 0.1456 0.1587 0.0293 HUNTER 2/0 2/0 0.1326 0.1456 0.1587 0.0293 HOLLINS 3/0 1/0 0.1053 0.1157 0.1259 0.0286 ROCKLAND 3/0 3/0 0.1053 0.1157 0.1259 0.0286 SWEETBRIAR 4/0 2/0 0.0835 0.0917 0.1000 0.0279 MONMOUTH 4/0 4/0 0.0835 0.0917 0.1000 0.0279 PRATT 250 3/0 0.0706 0.0777 0.0847 0.0284 WESLEYAN 350 4/0 0.0506 0.0557 0.0606 0.0275 NEWARK 350 350 0.0506 0.0557 0.0606 0.0275 RIDER 500 350 0.0356 0.0390 0.0426 0.0266 WESTCHESTER 500 500 0.0356 0.0390 0 0426 0.0266 FAIRFIELD 750 500 0.0251 0.0263 0.0286 0.0264 RHO = 90, phase spacing is phase conductor outside diameter. Impedance Data POSITIVE SEQUENCE POSITIVE SEQUENCE RESISTANCE INDUCTIVE REACTANCE Code Word Phase Neutral 25 C 50 C 75 C X1 TULSA 4 4 0.4227 0.4645 0.5064 0.0335 DYKE 2 4 0.2655 0.2929 0.3182 0.0319 WITTENBERG 2 2 0.2655 0.2929 0.3182 0.0315 NOTRE DAME 1/0 2 0.1671 0.1837 0.2002 0.0301 PURDUE 1/0 1/0 0.1671 0.1837 0.2002 0.0301 SYRACUSE 2/0 1 0.1326 0.1456 0.1587 0.0293 LAFAYETTE 2/0 2/0 0.1326 0.1456 0.1587 0.0293 SWARTHMORE 3/0 1/0 0.1053 0.1157 0.1259 0.0286 DAVIDSON 3/0 3/0 0.1053 0.1157 0.1259 0.0286 WAKE FOREST 4/0 2/0 0.0835 0.0917 0.1000 0.0280 EARLHAM 4/0 4/0 0.0835 0.0917 0.1000 0.0280 RUST 250 3/0 0.0706 0.0777 0.0847 0.0284 SLIPPERY ROCK 350 4/0 0.0506 0.0557 0.0606 0.0275 NIAGARA 350 350 0.0506 0.0577 0.0606 0.0275 WOFFORD 500 350 0.0356 0.0390 0.0426 0.0267 WINDHAM 750 500 0.0251 0.0263 0.0286 0.0264 RHO = 90, phase spacing is phase conductor outside diameter. UNDERGROUND SECONDARY 600 VOLT CABLES Triplex Aluminum Conductor Impedance Data Quadruplex Aluminum Conductor

Alcan Cable operates throughout North America in the U.S. as a division of Alcan Products Corporation, and in Canada as a division of Alcan, Inc. Alcan Cable has its own research and development facilities and is backed by the technology and laboratories of the Alcan Group. We re proud of our long history of providing new and innovative aluminum solutions to the many customers we serve. ALCAN CABLE Division of Alcan Products Corporation Three Ravinia Drive, Suite 1600 Atlanta, GA 30346-2133 770-394-9886 fax 770-677-2609 www.cable.alcan.com UT0001 (11/03)