Electromotoric Actuators. for zone valves VVI46.., VXI46.., VVS46.. and VXS46..

Similar documents
Electromotoric Actuators

2-Port and 3-Port Zone Valves, PN 16 / 20

2-Port and 3-Port Zone Valves & Actuators, PN16

2-Port and 3-Port Zone Valves, PN16

Electromotoric Actuators

Electrical Actuators

Electromotoric Actuators

2-Port and 3-Port Zone Valves PN 16

Electromotoric Actuators

Electromotoric actuators

Electromotoric Actuators

Electromotoric actuators

Electric actuators for small valves

Electromotoric Actuators

2-Port and 3-Port Zone Valves PN 16

Butterfly valves PN 16

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Electro-hydraulic actuators for valves

Butterfly valves PN 16

3-port seat valves, external thread, PN16

2-position electric actuators with Ball valves VBZ ½...11/4

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

Three-port slipper valves PN10, female-threaded

Butterfly valves PN6, PN10, PN16

3-Port Seat Valves with Male Thread, PN 16

Actuators for small valves

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

3-Port Seat Valves with Male Thread, PN 16

2-port and 3-port valves with T-bypass PN 16

2-port ball valves with flanged connection, PN25

2-port and 3-port terminal unit valves PN16

Actuators for air dampers and control valves of oil burners

3-port seat valves PN16 with flanged connection

3-port seat valves PN16 with flanged connection

Actuators for air dampers and control valves of oil burners

SQL35.00 SQL85.00 SQK angle of rotation

3-Port Seat Valves with Flange, PN 6

3-Port Seat Valves with Flange, PN 10

MF /MS Series

3-port seat valves PN10 with flanged connection

Modulating control valves with magnetic actuator PN 16

Actuators for air dampers and control valves of oil burners

3-port seat valves PN6 with flanged connection

Air damper actuators

Butterfly valves, PN6, PN10, PN16

Modulating control valves with magnetic actuators, PN 16

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

3-port seat valves PN40 with flanged connection

2-port and 3-port ball valves PN 40

2-Port Seat Valves with Flange, PN 25

2-port seat valves PN16 with flanged connection

Open/close ball valves 2-port and changeover ball valves 3-port, PN40

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

V4043 and V4044 Motorized Valves

Power consumption In operation At rest For wire sizing

GDB..3..1A GLB..3..1A

MXG MXF Modulating control valves PN 16 with magnetic actuators. Building Technologies HVAC Products

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

Two-port and three-port small valves PN16, ANSI Class 250

Zone Valves and Parts (Honeywell)

Air damper actuators

Electrothermal actuators

Actuators for Fire Protection Dampers

Electro-hydraulic actuators for valves

Differential Pressure Sensors

2-port seat valves PN25 with flanged connection

SAX Electronic Valve Actuator

ACVATIX MiniCombiValves (MCV)

SAV Electronic Valve Actuator

Butterfly valves PN6, PN10, PN16

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing

Cooling water Chilled water Low temperature hot water C Water with anti-freeze (max. 50%vol.)

Actuators. Building Technologies Division

Actuators for Fire and Smoke Protection Dampers

Operating instruction Refrigerant Valves PS45

Modulating Control Valve PN 16 with Magnetic Actuator

Temperature Controller (Heat Pumps)

Modulating control valves with magnetic actuators, PN 16

2-Port Seat Valves with Flange, PN 25

Modulating control valve PN16 with magnetic actuator

Differential Pressure Sensors

Actuators for Air and Gas Dampers

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position)

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

Actuators for Fire and Smoke Protection Dampers

VLF45... Hot Air Valves. Building Technologies Division

Modulating control valve with magnetic actuator PN16

Gas Pressure Governors

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

Electro-hydraulic actuators for valves

Rotary actuators for ball valves

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

VPI45..Q with pressure test points. Combi valves, PN 25

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

Differential Pressure Sensors

Modulating control valves with magnetic actuator PN 16

Transcription:

4 863AP Electromotoric Actuators for zone valves VVI46.., VXI46.., VVS46.. and VXS46.. SFA21.. SFA11U SFA71 SFA21.. AC 230 V operating voltage, 2-position control signal SFA11U AC 110 V operating voltage, 2-position control signal SFA71 AC 24 V operating voltage, 2-position control signal Positioning force 200 Spring return Manual adjustment For direct mounting with union nut (no tools required) Visual position indication Auxiliary switch, type ASC2.1/18 (optional) U approved for plenum installation Use The SFA21.., SFA11U and SFA71 actuators are used in conjunction with zone valves V..I46.. und V..S46.., primarily in heating, ventilation, air conditioning and refrigeration systems for water-based control of low-temperature hot water and cooling water. CE14863AP 24.09.2008 For Asia-Pacific market only Building Technologies HVAC Products

Type summary Type Operating voltage Positioning time Positioning signal SFA21 AC 230 V SFA21U 1) 10 s 2-position SFA11U 1) AC 110 V SFA71 AC 24 V 1) Actuators with type suffix U are U approved Accessories Type Description Switching point Switching capacity Connecting cable ASC2.1/18 Auxiliary switch at approx. 50 % stroke AC 250 V / 3(2) A 1.8 m Ordering When ordering please specify the quantity, product name and type code. Example 2 electric actuators, type SFA11U and 2 auxiliary switches, type ASC2.1/18 Delivery Actuators, valves and accessories are supplied separately. Equipment combinations Zone valves P 16 Type Valve type k vs [m 3 /h] P-class D Data sheet VVI46.. 2-port valves, internal thread Rp VVS46.. 2-port valves, solder connection VXI46.. 1) 3-port valves, internal thread Rp 2.0 5.0 P 16 / 20 15 25 4842.. VXS46.. 3-port valves, solder connection 1) 3-port valve with tight bypass order separately: VXI46.25T with SFA.. electromotoric actuator, for details see datasheet 4842 k vs = ominal flow rate of cold water (5 30 C) through the fully open valve (H 100 ) by a differential pressure of 100 kpa (1 bar) Thermostats Type RAA RAB RCC RDX RDF RDE RDD RCU Compatible thermostats for SFA21.., SFA11U and SFA71 RAA10; RAA20; RAB30..; RAA40 RAB10; RAB10.1; RAB20; RAB20.1; RAB30; RAB30.1; RAB40.1 RCC10; RCC20; RCC20.1; RCC30 RDX42.2 RDF10; RDF10.1; RDF10.2; RDF20; RDF30, RDF110, RDF210 RDE10; RDE10.1; RDE20.1 RDD10; RDD10.1 RCU10; RCU10.1 Technical design / mechanical design The electric actuator requires an on/off controller (thermostat) to control the valve. If the temperature of the medium deviates from the setpoint, the controller output signal causes the actuator to drive the valve open. When the temperature of the medium reaches the setpoint, the control signal is cut off and the valve closes again. The valve is opened electrically by the actuator and closed by spring force. It incorporates a synchronous motor, a gear mechanism and a return spring. The electric motor is overload-resistant and anti-locking, so that continuous operation is possible. The maximum stroke is limited mechanically. The closing motion, by contrast, includes an overrun for the gear mechanism. This protects the gear mechanism from mechanical shock and increases service life. 2/6 Building Technologies Electromotoric Actuators CE14863AP

Accessories Auxiliary switch ASC2.1/18 The optional auxiliary switch can be fitted to the actuator with two screws. It switches at a stroke of approx. 50 %. 01468 0 50 % : 1 2 closed 1 4 open 50 % 1 : 1 2 open 1 4 closed See «Technical data» for further information on the auxiliary switch. Engineering notes Electrical connection Caution The admissible temperatures (see «Technical data») must be observed. The actuator may be operated only with alternating current (see «Technical data»). For safety and protection reasons connect the actuator with a suitable cable conduit, e.g. Phase cut and pulse-duration-modulated signals are not suitable. Recommended number of opening/closing operations: approx. 50 per day, with 200 heating or cooling days Mounting notes Mounting instructions 74 319 0407 0 are enclosed with the packaging. Orientation 85 85 4863Z01 Commissioning notes Check the wiring. Check the functioning of the actuator and of the auxiliary switch, if fitted. Manual adjustment The valve can be opened manually by use of a lever on the actuator. When the valve is approximately 90% open the lever locks into position. When electrical operation is resumed, the locking mechanism is released automatically. Open the valve manually Releasing the lever manually 4867Z08 a 4867Z09 4867Z10 b Rotate lever The lever is locked into position at a valve opening of approx. 90% Rotate lever as far as the mechanical stop, and release Building Technologies Electromotoric Actuators CE14863AP 3/6

Maintenance The actuators require no maintenance. Caution They cannot be repaired. In the event of a fault, the actuator can be replaced without removing the valve. The operating voltage must be switched off during this process. Disposal The device includes electrical components and must not be disposed of as domestic waste. egislation may demand special handling of certain components, or it may be sensible from an ecological point of view. Current local legislation must be observed. Warranty The technical data given for these applications is valid only when the valves are used with the actuators described under «Equipment combinations». The use of these actuators with third-party valves invalidates any warranty offered by Siemens Switzerland td / HVAC Products. 4/6 Building Technologies Electromotoric Actuators CE14863AP

Technical data Power supply Operating voltage Voltage tolerance SFA21 SFA21U SFA11U SFA71 AC 230 V ± 15 % AC 110 V 15 / +25 % AC 24 V ± 20 % Frequency 50 Hz 60 Hz 50 / 60 Hz Power consumption Primary fuse 12 VA external Control Positioning signal 2-position 1) Operating data Parallel operation of several actuators permitted 2) Opening / closing operations Position with de-energized actuator 2-port valve (VVI46.., VVS46..) 3-port valve (VXI46.., VXS46..) Positioning time (opening / closing) Positioning force ominal stroke Admissible temperature of medium in the connected valve recommended number: approx. 10'000 / year (equivalent to approx. 50 / day) A AB closed AB A closed 10 s 200 2.5 mm +1 110 C Manual adjustment 0 90 % Housing protection Upright to 85 horizontal, do not suspend Mounting location IP30 EMA 1 (interior only) Conformity U cu (Canadian Standard) U 873 cu C22.2 o. 24-93 Mounting Fixing on valve plastic union nut M30 x 1.5 Orientation upright to 85 horizontal, do not suspend Dimensions / weight Dimensions refer to «Dimensions» Weight without auxiliary switch with auxiliary switch 0.585 kg 0.692 kg Materials Base plate die-cast aluminium Housing PBT Housing colors Base and cover light gray RA7035 ever, union nut pigeon blue RA5014 Auxiliary switch (optional) Switching type changeover contact Switching point Switching capacity Connecting cable at approx. 50 % stroke AC 250 V, 3 A resistive, 2 A inductive 3-core, 1.8 mm 18 AW (0.96 mm 2 ) 1) 2) 3) Phase cut and pulse-duration-modulated (PDM) signals are not suitable. Consider controller s power output. Standard is only met when the actuator is connected with a suitable cable conduit. eneral ambient conditions Operation E 60721-3-3 Transport E 60721-3-2 Storage E 60721-3-2 Environmental conditions Class 3K3 Class 2K3 Class 2K3 Temperature +1 +50 C 25 +70 C 25 +70 C Humidity 5 85 % r. h. < 95 % r. h. < 95 % r. h. Building Technologies Electromotoric Actuators CE14863AP 5/6

Connecting cable SFA21, SFA21U actuator SFA11U actuator 4863Z13 blue brown yellow/green System neutral System potential AC 230 V Earth 4863Z14 white black yellow/green System neutral System potential AC 110 V Earth 4863Z08 black 0 red System neutral System potential AC 24 V ASC2.1/18 auxiliary switch 4863Z12 4 2 1 black / pink black / blue black / red 0 50 % : 1 2 50 % 1 : 1 4 Connection diagrams (AC 230/110 V) external 1 / 11 4863A03 SP (AC 24 V) S 1 / 11 0 external 4863A02 1 controller (thermostat) actuator with zone valve system potential AC 230/110 V system neutral control signal OPE controller contact Earth connection 0 1 controller (thermostat) actuator with zone valve system potential AC 24 V (SP) system neutral (S) control signal OPE controller contact Dimensions Dimensions in mm Actuator without auxiliary switch SFA21.., SFA11U, SFA71 80 79.7 58 112 4863M01 Actuator with auxiliary switch SFA21.., SFA11U, SFA71 with ASC2.1/18 106 79.7 58 0 1 112 4863M02 6/6 2008 Siemens Switzerland td Subject to alteration Building Technologies Electromotoric Actuators CE14863AP